HomeMy WebLinkAboutFile Documents.208 E Main St.0195.2019 (3).ARBKScale:
ISSUE
A 2.0
6/30/20Plotted On:LO
W
E
R
L
E
V
E
L
F
L
O
O
R
P
L
A
N
ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS
I N D I C AT E D B Y T H E S E D R A W I N G S A N D
SPECIFICATIONS ARE THE PROPERTY AND
COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC.
AND SHALL NEITHER BE USED ON ANY OTHER WORK
NOR BE USED BY ANY OTHER PERSON FOR ANY USE
WHATSOEVER WITHOUT WRITTEN PERMISSION.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS AND SHALL BE VERIFIED
AT THE SITE. ANY DIMENSIONAL DISCREPANCY
SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL HAVE
BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
AS NOTED
DATE
SCHEMATIC DESIGN03/11/17
"S
A
L
O
N
T
U
L
L
I
O
"
20
8
E
.
M
A
N
S
T
R
E
E
T
AS
P
E
N
C
O
,
8
1
6
1
1
04/03/17 PERMIT SUBMITTAL
11/07/17 COMMENTS 1
08/20/18 COMMENTS 2
08/16/19 CHANGE ORDER 2
06/22/19 CHANGE ORDER 3
1 1
B
B
2 2
C
C
A
A
D
D
16 x 10 3/4" x 7 1/2"
1 2 3 4 5 6 7 8 9 10 11 12
13
14
15
16
E
E
F
F
3
A5.1
3
A5.1
01
A4.2
3 3
UP
UP
BEDROOM 1
002
HALLBEDROOM 2
004
BATH 1
003
TREATMENT
ROOM
008
SPA
HALL
007
WINDOW
WELL
SIDE SETBACK LINEWINDOW WELL
ENTRY ABOVE
STORAGE
T.O. SLAB
90'-0"
T.O. SLAB
91'-2 5/8"
FR
O
N
T
S
E
T
B
A
C
K
L
I
N
E
PR
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
CRAWL SPACE
UNDERNEATH HISTORIC
RESOURCE
009
T.O. SLAB
91'-2 5/8"
SHOWER
WC
CLOSET
005
CLOSET
WC
SH
O
W
E
R
BATH 2
006
007TV
(ON
S
W
I
N
G
A
R
M
)
W-3
A7.2
W-3
A7.2
CLOSET
TREATMENT
ROOM
MECHANICAL
ROOM
(COMMERCIAL)
010
T.O. SLAB
91'-2 5/8"
MECHANICAL
ROOM
(RESIDENTIAL)
007
04(E)F
C010
C0
1
1
C0
1
3
01(E)F
03
(
E
)
F
02
(
E
)
F
00
5
00
1
006
00
3
004
00
2
C012
C0
1
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
85'-8 3/4"
19'-9"16'-8"10'-3 3/4"
26
'
-
1
3
/
4
"
12
'
-
1
1
1
/
4
"
8"3 1/2"12'-2"3 1/2"8"8'-5 1/2"8"3 1/2"8'-3"
19'-3"
11
1
/
2
"
10
"
11'-11"
3'
-
3
1
/
2
"
1
1
/
4
"
14
'
-
1
1
/
4
"
5'
-
1
1
3
/
4
"
5
1
/
2
"
3'
-
1
/
2
"
6"
10'-4 1/2"6"5'-4"
13
'
-
2
1
/
2
"
11
'
-
2
1
/
2
"
5
1
/
2
"
10
'
-
1
0
1
/
2
"
21'-1 1/4"5 1/2"
3 1/2"6'-3 1/2"3 1/2"11'-6 1/2"
7"
25
'
-
2
1
/
4
"
8"
3
1
/
2
"
11
'
-
8
3
/
4
"
5
1
/
2
"
3'
-
4
1
/
2
"
3
1
/
2
"
7'
-
5
"
3
1
/
2
"
8"
10'-3 3/4"16'-8"
8"8"3 1/2"2"
8"
3'
-
1
3
/
4
"
8"
3
1
/
2
"
6'
-
1
1
/
2
"
5'-2 1/2"8"3 1/2"2'-3 1/2"
6"52'-6 3/4"8"
6'3 1/2"5'-10 1/2"
4'
-
1
0
1
/
2
"
3
1
/
2
"
3'
-
3
/
4
"
3'
-
1
1
/
2
"
6'
-
1
/
2
"
3
1
/
2
"
2'
-
3
1
/
4
"
3 1/2"
4'-7 3/4"3 1/2"7'-9 1/4"3 1/2"3'-10 1/2"
3
1
/
2
"
2'
-
1
"
3
1
/
2
"
9'
-
1
1
1
/
4
"
5
1
/
2
"
11
'
-
1
"
5 1/2"
3 1/2"
2'-11"1/2"2'-11"6'-10"3 1/2"
3'
-
2
"
26'-10"12'-1 3/4"
4'
-
6
"
1'
-
1
1
"
5
1
/
2
"
7'
-
3
1
/
4
"
2'
-
7
1
/
2
"
3'
-
4
"
3
1
/
2
"
9'-9 3/4"3 1/2"6'-4"5 1/2"
3'
-
3
"
3
1
/
2
"
7'
-
8
"
6"8"
12
'
-
1
"
6'
-
1
1
3
/
4
"
11
'
-
3
1
/
8
"
11
'
-
3
1
/
8
"
3
1
/
2
"
26'-8 1/2"
3 1/2"5'-6"3 1/2"5'-9"
11 1/2"
11
1
/
2
"
12
'
-
9
1
/
2
"
12
'
-
1
1
3
/
4
"
3'
-
3
1
/
4
"
10"3'-6"
2'
-
5
1
/
4
"
5'
2'
-
5
1
/
4
"
3'
-
7
1
/
4
"
3
1
/
2
"
3'
-
5
"
1
1
/
2
"
8"
5
1
/
2
"
2'-4 3/4"6'-4"2'-9"
2 HR SEPARATION
BETWEEN
TRASH
ENCLOSURE
ABOVE
NEW UNDERPINNED
FOUNDATION
UNDERNEATH HISTORIC
CABIN. PER STRUCTURAL
APPROVED
SET BACK
90 MIN. FIRE RATED DOOR.
NO ADDITIONAL PENETRATIONS
IN THE WALL SEPARATING RESIDENTIAL
AND COMMERCIAL WILL BE DONE WITHOUT
THE ISSUANCE OF A BUILDING PERMIT.
KING SIZE
BED
UP
KING BED
76"X80"
QUEEN BED
60"X80"
4
A5.1
4
A5.1
1
A5.0
1
A5.0
2
A5.0
2
A5.0
5
A5.1
5
A5.1
6
A5.2
6
A5.2
7
A5.2
7
A5.2
03
EAST
04
WEST
02
SOUTH
N
001
SCALE: 1/4" = 1'-0"
1 LOWER LEVEL PLAN
A 2.0
PLAN NOTES:
- 50 PERCET OF LIGHT BULBS TO BE HIGH
EFFICACY.
"PARTY WALL":
FIRE RATED ASSEMBLIES (WALLS AND FLOOR/
CEILING).
SEE SHEETS A7.5, A7.6, A7.7 AAND A7.8 FOR
DWELLING SEPARATION DETAILS.
not required
not required
Scale:
ISSUE
A 2.1
6/30/20Plotted On:MA
I
N
L
E
V
E
L
F
L
O
O
R
P
L
A
N
ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS
I N D I C AT E D B Y T H E S E D R A W I N G S A N D
SPECIFICATIONS ARE THE PROPERTY AND
COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC.
AND SHALL NEITHER BE USED ON ANY OTHER WORK
NOR BE USED BY ANY OTHER PERSON FOR ANY USE
WHATSOEVER WITHOUT WRITTEN PERMISSION.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS AND SHALL BE VERIFIED
AT THE SITE. ANY DIMENSIONAL DISCREPANCY
SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL HAVE
BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
AS NOTED
DATE
SCHEMATIC DESIGN03/11/17
"S
A
L
O
N
T
U
L
L
I
O
"
20
8
E
.
M
A
N
S
T
R
E
E
T
AS
P
E
N
C
O
,
8
1
6
1
1
04/03/17 PERMIT SUBMITTAL
11/07/17 COMMENTS 1
08/20/18 COMMENTS 2
08/16/19 CHANGE ORDER 2
06/22/19 CHANGE ORDER 3
1 1
B
B
2 2
C
C
A
A
D
D
16 x 10 3/4" x 7 1/2"
1 2 3 4 5 6 7 8 9 10 11 12
13
14
15
16
E
E
F
F
UP
1 2 3 4 5 6 7 8 9 10 11
12
13
14
15
16
17
10
6
C1
7
X
C1
1
4
3
A5.1
3
A5.1
8
A5.1
8
A5.1
01
A4.2
3 3
DN DN
BATH
110
SALON - SHAMPOO
ROOM
111
SALON
112
SALON
RECEPTION
113
SALON
AIRLOCK
114
SALON
112
STAIR
102
LAUNDRY/
MUD ROOM
101
MASTER
BATH
104
CONC. PAVERS
T.O. FIN. FL. (e)
102'-3 1/4"
T.O. FIN. FL. (e)
102'-7 1/4"
T.O. FIN. FL. (e)
102'-3"
C10F
SIDE SETBACK LINE
FR
O
N
T
S
E
T
B
A
C
K
L
I
N
E
PR
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
TRASH
ENCLOSURE
106
STEEL GRATE
W/ OPERABLE PANEL
OVER WINDOW WELL
1 2 3
MASTER
BEDROOM 105
4
W-
1
3
A6
.
5
W-
1
0
A7
.
3
W-
1
0
A7
.
3
W-
1
0
A7
.
3
W-
1
0
A7
.
3
W-3
A7.2
W-14
A6.5
W-14
A6.5
W-
1
4
A6
.
5
100
ENTRY
CL
O
S
E
T
CL
O
S
E
T
C0
1
3
C1
8
C1
6
C113
C11 C13C12
C112
C1
1
1
C110
C14
13
12(E)F
10
14
10
4
15F
105
103
10
A
W/DW/DW/D
03
19'-9"16'-8"
26
'
-
1
3
/
4
"
11 1/2"
16'-2 1/2"26'-8 1/2"11'-11 1/4"1'-4 1/2"
12
'
-
1
1
1
/
4
"
3'
-
3
1
/
4
"
11
1
/
2
"
5 1/2"13'-7 1/2"
12'-1 3/4"13'-3 3/4"
3'
4
1
/
4
"
3'
-
9
"
5'
-
2
1
/
2
"
4'
-
5
3
/
4
"
5'
-
6
1
/
4
"
1'
-
8
1
/
4
"
13
'
-
2
1
/
2
"
11 1/2"
4'-3"5 1/2"14'-1 1/2"
5 1/2"
3'
-
5
3
/
4
"
5
1
/
2
"
5 1/2"
7'-7 1/2"3 1/2"6'-2 1/2"
4'
-
8
"
5
1
/
2
"
7'
-
2
1
/
4
"
1'
-
6
1
/
2
"
5
1
/
2
"
11
'
-
3
1
/
2
"
5
1
/
2
"
5 1/2"8'-5 1/2"5 1/2"12'-11 1/2"5 1/2"
5'-2 1/2"5 1/2"2'-9 1/2"
11 1/2"5 1/2"13'-2"5 1/2"13'-1 1/2"3 1/2"8'-5 1/2"
5
1
/
2
"
4'
-
7
"
3
1
/
2
"
3'
-
6
1
/
2
"
5
1
/
2
"
1'
-
1
3
/
4
"
5
1
/
2
"
1'
-
9
1
/
4
"
5'
-
5
3
/
4
"
3
1
/
2
"
4'
-
1
0
3
/
4
"
2'
5'
-
2
"
26'-10"10'-3 3/4"
10'-9 1/4"
5'
-
1
3
/
4
"
5
1
/
2
"
4'
-
7
3
/
4
"
5'
-
6
"
1 1/2"6"8"
1'
-
1
/
2
"
4'
-
7
3
/
4
"
5
1
/
2
"
19'-9"16'-8"10'-3 3/4"
5 1/2"
11
1
/
2
"
12
'
-
9
1
/
2
"
12
'
-
1
1
3
/
4
"
3'
-
3
1
/
4
"
3'
-
3
1
/
4
"
2'
-
4
1
/
4
"
2'
-
6
"
2'
-
4
1
/
4
"
4
A5.1
4
A5.1
1
A5.0
1
A5.0
2
A5.0
2
A5.0
5
A5.1
5
A5.1
6
A5.2
6
A5.2
7
A5.2
7
A5.2
03
EAST
04
WEST
02
SOUTH
1
A4.3
2
A4.3
05
SOUTH-2
SLOPED
CONC. S.O.G.
SKYLIGHT ABOVE
STEEL GRATE W/
OPERABLE PANEL
OVER WINDOW WELL
2 HR SEPARATION BETWEEN
OCCUPANCIES
REPAIR AND RESTORE
PORCH WITH HPC
APPROVAL
APPROVED
SET BACK AC UNIT
(BEHIND SETBACK)
NO PENETRATIONS IN THE WALL
SEPARATING RESIDENTIAL AND
COMMERCIAL WILL BE DONE WITHOUT
THE ISSUANCE OF A BUILDING PERMIT.
THIS SECTION OF TRASH ENCLOSURE
HAS TO CANTILEVER OVER THE
FOUNDATION WALL BELOW
DOOR TO MATCH
ADJACENT
CABINETS
STAIRS:
METAL STRUCTURE
W/METAL MESH TREADS
AWNING ABOVE
ENTRY DOOR
FROSTED
GLASS
CLEAR
GLASS
BARNWOOD ON
BARN DOOR
DN
NOTE:
EXISTING MINER'S CABIN WILL REMAIN
WHERE IT IS.
CLOSET
BUILT IN BENCH
BUILT-IN CUBBIES/SHELVING
HANGING & SHELVING TALL
STORAGE
STACKED
THIS WALL
MOVED IN
5"
DNDN
N
T.O. PLY
100'-0"
103 T.O. PLY
100'-0"
(BUILT IN
TV ABOVE)
SCALE: 1/4" = 1'-0"
1 MAIN LEVEL PLAN
A 2.1
PLAN NOTES:
- 50 PERCET OF LIGHT BULBS TO BE HIGH
EFFICACY.
"PARTY WALL":
FIRE RATED ASSEMBLIES (WALLS AND FLOOR/
CEILING).
SEE SHEETS A7.5, A7.6, A7.7 AAND A7.8 FOR
DWELLING SEPARATION DETAILS.
no required
Scale:
ISSUE
A 2.2
6/30/20Plotted On:UP
P
E
R
L
E
V
E
L
F
L
O
O
R
P
L
A
N
ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS
I N D I C AT E D B Y T H E S E D R A W I N G S A N D
SPECIFICATIONS ARE THE PROPERTY AND
COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC.
AND SHALL NEITHER BE USED ON ANY OTHER WORK
NOR BE USED BY ANY OTHER PERSON FOR ANY USE
WHATSOEVER WITHOUT WRITTEN PERMISSION.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS AND SHALL BE VERIFIED
AT THE SITE. ANY DIMENSIONAL DISCREPANCY
SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL HAVE
BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
AS NOTED
DATE
SCHEMATIC DESIGN03/11/17
"S
A
L
O
N
T
U
L
L
I
O
"
20
8
E
.
M
A
N
S
T
R
E
E
T
AS
P
E
N
C
O
,
8
1
6
1
1
04/03/17 PERMIT SUBMITTAL
11/07/17 COMMENTS 1
08/20/18 COMMENTS 2
08/16/19 CHANGE ORDER 2
06/22/19 CHANGE ORDER 3
1 1
B
B
2 2
C
C
A
A
D
D
E
E
F
F
UP
1 2 3 4 5 6 7 8 9 10 11
12
13
14
15
16
17
3
A5.1
3
A5.1
01
A4.2 F
3 3
SIDE SETBACK LINE
SIDE SETBACK LINE
FR
O
N
T
S
E
T
B
A
C
K
L
I
N
E
PR
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
STAIR
201
KITCHEN
204
SKYLIGHTS
ABOVE
SIDE SETBACK LINE
RE
A
R
S
E
T
B
A
C
K
DNT.O. PLY.
111'-0"
6:
1
2
(
e
)
4:
1
2
(
e
)
POWDER
205
STAIR
206
26
A
26
26
24F 21F
22
23
22
23
29F
32
27
28
21F
20F
20
1
202
25F
S0
1
Si
l
l
1
1
/
4
"
11'-2"
1'
1
A6.1
4
A5.1
4
A5.1
1
A5.0
1
A5.0
2
A5.0
2
A5.0
5
A5.1
5
A5.1
6
A5.2
6
A5.2
7
A5.2
7
A5.2
03
EAST
04
WEST
02
SOUTH
16'-8"
26
'
-
3
1
/
2
"
13
'
-
1
"
5
1
/
2
"
13
'
-
2
1
/
2
"
46'-8 3/4"
19'-9"
4'-8 1/2"
2'
-
9
"
16'-8"10'-3 3/4"5 1/2"5 1/2"14'-1 1/2"5 1/2"
5'-11 3/4"5 1/2"7'-8 1/4"
5
1
/
2
"
7'
-
2
1
/
4
"
5
1
/
2
"
27'-10 3/4"
3'
-
5
1
/
2
"
3
1
/
2
"
3'
-
5
1
/
4
"
3 1/2"10'-6"3'-11"12'-3 1/2"
1'
-
1
1
"
7"
3'
-
6
"
5'-6"3"3'-2"
3'
-
1
0
"
3'
-
6
"
2'
1'-6"
3'
-
4
1
/
2
"
3'
-
5
3
/
4
"
12'-1 3/4"26'-10"10'-3 3/4"
7'
-
2
1
/
2
"
16'-8"10'-3 3/4"5 1/2"
11
1
/
2
"
12
'
-
9
1
/
2
"
12
'
-
1
1
3
/
4
"
3'
-
3
1
/
4
"
1
A6.3
2
A6.3
ROOF OVER
TRASH ENCLOSURE
RELOCATED EXISTING
SHED BELOW
APPROVED
SET BACK
N
DW
LIVING
202
DINING
203
SKYLIGHT BELOW
EXISTING HISTORIC RESOURCE ROOF
W-
1
0
A7
.
3
W-
1
0
A7
.
3
5
1
/
4
"
18
'
-
8
"
3
3
/
4
"
GAS RANGE
(2) 3" PVC
BOILER MULTIVENTING
SIDEWALL VENT
TERMINATION
SCALE: 1/4" = 1'-0"
1 UPPER LEVEL PLAN
A 2.2
PLAN NOTES:
- 50 PERCET OF LIGHT BULBS TO BE HIGH
EFFICACY.
"PARTY WALL":
FIRE RATED ASSEMBLIES (WALLS AND FLOOR/
CEILING).
SEE SHEETS A7.5, A7.6, A7.7 AAND A7.8 FOR
DWELLING SEPARATION DETAILS.
not required
not required
not required
Scale:
ISSUE
A 9.1
6/30/20Plotted On:FI
R
E
A
R
E
A
ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS
I N D I C AT E D B Y T H E S E D R A W I N G S A N D
SPECIFICATIONS ARE THE PROPERTY AND
COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC.
AND SHALL NEITHER BE USED ON ANY OTHER WORK
NOR BE USED BY ANY OTHER PERSON FOR ANY USE
WHATSOEVER WITHOUT WRITTEN PERMISSION.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS AND SHALL BE VERIFIED
AT THE SITE. ANY DIMENSIONAL DISCREPANCY
SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL HAVE
BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
AS NOTED
DATE
SCHEMATIC DESIGN03/11/17
"S
A
L
O
N
T
U
L
L
I
O
"
20
8
E
.
M
A
N
S
T
R
E
E
T
AS
P
E
N
C
O
,
8
1
6
1
1
04/03/17 PERMIT SUBMITTAL
11/07/17 COMMENTS 1
08/20/18 COMMENTS 2
08/16/19 CHANGE ORDER 2
06/22/19 CHANGE ORDER 3
1 1
B
2 2
CA D
16 x 10 3/4" x 7 1/2"
1 2 3 4 5 6 7 8 9 10 11 12
13
14
15
16
E F
3 3 PR
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
007
04(E)F
C010
C0
1
1
C0
1
3
01(E)F
03
(
E
)
F
02
(
E
)
F
00
5
00
1
006
00
3
004
00
2
C012
C0
1
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
N
1,155.88 sq ft
1 1
B
2 2
CA D
16 x 10 3/4" x 7 1/2"
1 2 3 4 5 6 7 8 9 10 11 12
13
14
15
16
E F
UP
1 2 3 4 5 6 7 8 9 10 11
12
13
14
15
16
17
10
6
X
C1
1
4
3 3
C10F
PR
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
100
ENTRY
CL
O
S
E
T
CL
O
S
E
T
27.31 sq ft 156.17 sq ft
C0
1
3
C113
C112
C1
1
1
C110
12(E)F
14
10
4
15F
105
103
10
1'
-
1
3
/
4
"
1'
-
6
1
/
2
"
3'
-
5
3
/
4
"
5'
-
2
"
DNDN
N
1,669.73 sq ft
1 1
B
2 2
CA D E F
UP
1 2 3 4 5 6 7 8 9 10 11
12
13
14
15
16
17
F
3 3 PR
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
26
A
26
F
26
21F
22
22
29F
32
27
21F
20F
20
1
202
25F
S0
1
Si
l
l
1
1
/
4
"
11'-2"
1'
3'
-
4
1
/
2
"
7'
-
2
1
/
2
"
N
DW602.50 sq ft
(2) 3" PVC
BOILER MULTIVENTING
SIDEWALL VENT
TERMINATION
EX
I
S
T
I
N
G
B C D
331.06 sq ft
350.25 sq ft
135.47 sq ft
21.05 sq ft
31.79 sq ft
52.77 sq ft
12.76 sq ft
7 1/4" FROM
PROPERTY LINE
(0 TO LESS THAN 3)
3'-4 1/2" FROM
PROPERTY LINE
(3 TO LESS THAN 5)
1'-4" FROM
PROPERTY LINE
(0 TO LESS THAN 3)
8'-2" FROM
PROPERTY LINE
(5 TO LESS THAN 10)
ABCD
411.19 sq ft
131.71 sq ft
5.14 sq ft
535.56 sq ft
20.25 sq ft
55.30 sq ft
55.30 sq ft
29.72 sq ft
3'-5 3/4" FROM
PROPERTY LINE
(3 TO LESS THAN 5)
4'-11" FROM
PROPERTY LINE
(3 TO LESS THAN 5)
7'-2 1/2" FROM
PROPERTY LINE
(5 TO LESS THAN 10)
SCALE: 1/8" = 1'-0"
1 LOWER LEVEL FIRE AREA
A 9.1
SCALE: 1/8" = 1'-0"
2 MAIN LEVEL FIRE AREA
A 9.1
SCALE: 1/8" = 1'-0"
3 UPPER LEVEL FIRE AREA
A 9.1
SCALE: 1/8" = 1'-0"
4 WEST ELEVATION-FIRE AREA
A 9.1
SCALE: 1/8" = 1'-0"
5 EAST ELEVATION-FIRE AREA
A 9.1
FIRE AREA CALCULATION
UPPER LEVEL: 602.50
MAIN LEVEL: 1715.30+27.31+156.17
LOWER LEVEL: 1111.94
602.50
1669.73
1155.88
TOTAL 3,428.11 SQ.FT.
0'-3'
3'-5'
5'-10'
WALL AREA
SF
WINDOWS SF
466.53
350.25 52.84
PERCENTAGE
15.0 %
DISTANCE FROM
PROPERTY LINE
0.0 0.0 %
12.76 24.1852.77
NOTE:
AREA GREATER THAN 5000 SF
REQUIRES FIRE SPRINKLERS. THIS PROJECT IS BELOW THAT AREA.
TO COMPLY WITH UNPROTECTED OPENINGS SO WINDOWS IN 3'-5'
THE WINDOW ASSEMBLIES WILL BE FIRE RATED. SEE SPECS IN
SHEET A8.2.
0'-3'
3'-5'
5'-10'
WALL AREA
SF
WINDOWS SF
0.0
542.90 34.86
PERCENTAGE
6.42 %
DISTANCE FROM
PROPERTY LINE
EAST ELEVATION
535.56 130.85 24.43 %
0.0 0.0 %
IBC TABLE 705.8:
-0' TO LESS THATN 3' : PROTECTED (P)
-3' TO LESS THAN 5': PROTECTED AND 15% ALLOWABLE AREA.
-5' TO LESS THAN 10': PROTECTED AND 25% ALLOWABLE AREA.
IBC TABLE 705.8:
-0' TO LESS THATN 3' : PROTECTED (P)
-3' TO LESS THAN 5': PROTECTED AND 15% ALLOWABLE AREA.
-5' TO LESS THAN 10': PROTECTED AND 25% ALLOWABLE AREA.