Loading...
HomeMy WebLinkAboutFile Documents.695 S Aspen St.0059-2022-BCHO (2)REVISION CHANGES REV.DESCRIPTION DATE APPROVED A AS DRAWN 3/1/2021 CR B CHANGED DIMS, ADDED SKIRT, TOP PLATES, TOP MOUNT RIGGING, TILE 6/28/2021 CR C CHANGED SIZE, MOVED JETS 3/17/2022 CR DSI Internal Use Only: Fabrication Plumbing Project Management Sales SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 1 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN IAPMOEGS ELECTRICAL 1) Electrical requirements are specified for each unit. Only a licensed qualified electrician should connect the power supply. 2) Some units require more than one supply circuit. All power supply circuits must be located in the same disconnect box. (per NEC) Disconnect box must be more than 5(five) feet away from the tub and less than 50(fifty) feet away and within sight of spa. 3) All spas require a continuous bond. All spas are shipped with a bond connection on the frame. This connection must be made in the field. 4) Never turn the power on to the spa if it is empty. The spa needs water to properly test and satisfy diagnostic computations. 5) All electrical supply to the tub must be GFCI protected. 6) Any nearby electrical outlets, windows, hand rails or metal fencing may have special bonding requirements. Consult your licensed qualified electrician. 7) The communication cables for touch pad, low voltage lighting and water level sensors must be housed in separate conduits from the power supply. Never run communication and line voltage wires together. GAS 1) Gas requirements are specified with each unit. (where applicable) 2) Gas lines must follow guidelines and code requirements for your location. 3) Ventilation and combustion air needs are different for each unit. Please take time to check all proposed heater locations with your gas company or gas fitter to insure adequate combustion air and ventilation.PLUMBING 1) Pipe materials for all pool recirculation and therapy lines to be schedule 40 PVC(ASTM D1785). PVC pipng shall be stamped with N.S.F. seal of approval. All plumbing fittings and pipe must be pressure rated. 2) Prior to connection to spa, all underground plumbing must be pressurized and maintain pressure for 24 hours minimum. 3) All plumbing stub-out locations will be labeled on drawing. Confirm location if applicable. 4) Never handle or lift tub by plumbing. It is the responsibility of the client to make sure that all products are in compliance with local codes andregulations. Certain jurisdictions may require additional testing and/or listing. It is also the responsibilityof the client to arrange and pay for any permits, permit fees, inspections and inspection fees.Consult your local governmental agencies for additional information. Diamond Spas, Inc reserves the right to change , amend and/or modify all or any part of the fabrication including but not limited to vessel and/or equipment design, layout and/or components, at any timewithout notice. Approval of this drawing is acknowledgement of this notice and is legally binding. GENERAL INSTALLATION GUIDELINES Stainless steel and copper can become hot if left in direct sunlight for extended periods of time. DSI recommends undermounting all outdoor spas. NEVER LEAVE THE SPA UN-COVERED WHILE EMPTY excessive heat can build up on the spa if it is not full of water. A solid or opaque covering will suffice. Heat damage is not covered under your warranty. NEVER LEAVE CHILDREN UNATTENDED AROUND SPA 1) Spa must sit on a smooth, flat, level concrete pad. Pad should be a minimum of 4" thick an or as per the structural engineer. 2) The area under the hot tub unit and the equipment must have a waterproof pan or membrane that goes into a drain to prevent flooding or water damage to the region below. 3) Certain applications may use plywood decking and or other material for tub support. 4) PVC and conduit requirements are specified for each tub. Make sure that all underground lines are pressure tested prior to and during back fill. 5) DSI will specify the necessary space requirements for remote location equipment rooms. Equipment rooms are to be no more than 50' from the spa unless previously discussed with DSI. The room is recommended to be at or below the same elevation of the spa. 6) DSI recommends a floor drain in the spa vault and the equipment room vault. 7) Once you have the tub placed and level, connect all water, air and communication lines. All plumbing and communication lines are clearly labeled at the stub out location spa side as well as on the equipment package. DSI recommends that you fill and test the spa at this time to verify proper connection of all water, air and communication lines. 8) Upon inspection of all plumbing and conduits, you may now build the remaining retaining vault wall. Take appropriate precaution that the lines are not disturbed during back fill. 9) It is the responsibility of the owner/user to provide clear and easy access on all sides of the spa for repair. Otherwise, all additional costs to service and repair the spa will not be incurred by DSI. Inspection ports and/or service access is very important, please take this recommendation into consideration. If you have any questions and or need design ideas please call Diamond Spas. STAINLESS STEEL CARE 1) Stainless steel is highly resistant to rust and corrosion. Stainless steel is extremely durable and with proper care and maintenance will maintain it's luster and appearance indefinitely. 2) DSI uses 316L or 304L grade stainless. Each unit has a random hand finish applied to it as all product is hand crafted, exhibiting a visible concise weld seam. 3) DSI recommends rinsing any exposed stainless steel with fresh water on a a regular basis to remove any salt air or pollution contaminate. 4) Minor build up and/or spotting is simply removed with regular care and a "Scotch-Brite" scouring pad. 5) NEVER use steel wool or steel brushes on a DSI product. These products are carbon steel and leave particles that will rust and create stains. 6) If you should notice any staining and/or discoloration on the stainless steel surface it must be removed immediately. Most discoloration and staining is removed with the "Scotch-Brite" scouring pad. After the area is cleaned rinse with fresh water and dry with a a soft cloth. 7) If you have any questions, please contact DSI at 1-800-951-7727 COPPER CARE 1) DSI uses CR110 copper sheets to fabricate all units. All products are custom fabricated and TIG welded by hand. Each product has a hand buffed finish and patina applied to it. 2) Recommended cleaning is a mild detergent and a soft cloth. Wipe after each and every use to avoid water spotting. 3) Unless otherwise specified, DSI does apply a patina and wax after fabrication. This wax does not offer a permanent seal to the copper and only aids in excessive spotting. The copper will continue to spot and react to it's envirionment. Copper is referred to as the "living metal" and in this unsealed state has excellent antimicrobial properties. The wax will need to be reapplied as a maintenance issue. How often it will have to be reapplied depends on severaly factors such as usage, type of water, etc. DSI can also leave the product in its raw copper state upon request. 4) Environment will affect the patina process. Factors such as humidity, heat and water quality will determine what color your copper will turn. 5) Copper has the ability to change many colors such as pink, brown, blue, green etc. We are unable to tell you the exact color your product will change - it simply depends on the environment the product is exposed to. 6) Although rare, the possibility does exist that a deep patina finish may cause color change to parts of the body that come into contact with the bathing surface. To reduce the chance of this occurring, simply clean the bath with a copper cleaner. 7) If you have any questions, please contact DSI at 1-800-951-7727 RESIDENTIAL DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 08/15/2022 09/29/2022 jimp INSTALLATION INSTRUCTIONS REQUIRED ON SITE AT TIME OF INSPECTION 59.00 24.00 34.50 96.00 21.50 5.00 69.50 84.00 12.00 17.00 8.00 15.96 TYP 30.00 RECOMMENDED VAULT DIMENSION TO ALLOW FOR EQUIPMENT MAINTENANCE 18.00 RECOMMENDED VAULT DIMENSION FOR FUTURE MAINTENANCE 42.00 ADEQUATE DRAINAGE IS REQUIRED IF VESSEL IS TO BE INSTALLED BELOW GRADE SPA FRAME MUST BE IN COMPLETE CONTACT WITH A FLAT AND LEVEL STRUCTURAL SURFACE. INSTALLATION SURFACE TO MAINTAIN FLATNESS OF +/- 0.125". ANY GAP LARGER THAN 0.25" BETWEEN THE FRAME AND SURFACE MUST BE SHIMMED. CONTACT DSI FOR SHIMMING INSTRUCTIONS. A TOP RIGGING ON CORNERS (TOP PLATES WILL BE SHIPPED LOOSE) SPA SHELL PREPPED FOR TILE APPLICATION. TILE PROVIDED AND INSTALLED BY OTHER. DSI RECOMMENDS LATICRETE LATAPOXY 300 TILE ADHESIVE WITH SPECTRALOCK PRO EPOXY GROUT FOR PROPER TILE ADHESION. AMERICAN OLEAN UNGLAZED COLORBODY MOSAIC TILE RECOMMENDED FOR NON-SLIP DSI IS NOT RESPONSIBLE FOR SLIPPERY TREAD SURFACES. .19 TOP PLATE DETAIL A SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 2 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN NOTES: - due to the custom nature and welding processes involved in fabrication, there may be some distortion or warpingof the flat surfaces on our products. - all inside weld seams will be visible. - spa will be insulated with a 2-part polyurethane foam. - standard foam, snap-lock cover to be supplied w/ spa. SPA DATA - SPA SURFACE AREA = 27.6 SQ. FT. - SPA CAPACITY = 341 GALLONS - SPA WATER WEIGHT = 2,849 LBS. - SPA SHELL WEIGHT = 2,225 LBS. - SPA TOTAL WEIGHT = 5,073 LBS. DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/4" TWO PLACE DECIMAL 0.25" DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 dashed line indicates extent of edge of deck and guardrail extended min. 18" above spa 08/15/2022 09/29/2022 jimp B B C C DD EE 6.00 OPERATIONAL WATER LEVEL F G H SECTION B-B 24.50 13.50 38.00 18.50 32.00 SECTION C-C SECTION D-D J SECTION E-E .50 BOND BEAM PREPARED FOR TILE DETAIL F .38 SHIM THICKNESS DETAIL G ALL SUCTIONS, JETS, AND LIGHTS SHIMMED FOR TILE .50 TILE THICKNESS DETAIL H TILE MEETS OVERHANGING TOP PLATE .50 TILE THICKNESS DETAIL J TILE MEETS UNDER RAIL SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 3 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 08/15/2022 09/29/2022 jimp 37.50 TYP PANELS ATTACHED WITH 10-32 SS FHCS SOUTH ELEVATION WEST ELEVATION 28.00 TYP 36.00 TYP 3.00 TYP 3.00 TYP EAST ELEVATION 2.00 TYP NORTH ELEVATION SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 4 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 08/15/2022 09/29/2022 jimp AUTO COVER: -KEYPAD INSTALLED REMOTELY BY OTHERS, NO MORE THAN 15 FEET FROM AUTOCOVER & WITHIN EYESIGHT -REQUIRES 115V 10 A GFCI SERVICE AT KEYPAD 11 10 98 8 11 3X 11 11 8 55 11 11 10 9 12 14 13 2 11 2X 3847 4X 6 TOPSIDE: -MOUNTED REMOTELY BY OTHERS -DSI TO PROVIDE 25FT OF CABLE -1.5" FNPT DRAIN FITTING BELOW AUTOCOVER DRIVE MOTOR -CONNECTION TO WASTEWATER BY OTHER 11 15 15 11 1515 1 NOTES: - PLUMBING: - (2x) 3" PVC - SUCTION - (1X) 2.50" PVC - JET RETURN - (1X) 2" PVC - CIRCULATION RETURN - (1x) 1" CONDUIT - COMMUNICATION AND SPA LIGHT POWER - SPA SHELL TO BE BONDED WITH MIN. 6 GA BARE COPPER CONDUCTER - SPA LIGHT POWER REQUIRES MIN. 14 GA WIRE ITEM NO.QTY.EQUIPMENT DESCRIPTION 1 1 14GA & 12GA SS SPA SHELL W/3X2X.125" SS TUBE FRAME 2 1 AUTOCOVER - COVERSTAR - CS300 AUTOMATIC ELECTRIC SAFETY COVER 3 1 AUTOCOVER - COVERSTAR - STATIC SPOOL 4 1 AUTOCOVER SPOOL 5 2 AUTOCOVER RAIL 6 1 AUTOCOVER LEADING EDGE 7 4 AUTOCOVER - LID SUPPORT 8 4 Balboa Suction - 5 Inch - #39152 Balboa - VGB rated 256gpm - 2008 ASME Certified - 5" Suction 9 2 light - Waterway - 3.5 inch - #630-6005 // 3-1/2" face - front access - RGB LED w/ preset lighting patterns - 12volt -low voltage connection to control #410117-60-0-TLA, CONN, ASSY JUMPER, DAISY-LINK, 60",OVERMOLD (Qty.2) // #701570-14-DLSO-TLA, PCBA, 14 LED, RGB, SPA LIGHT, DAISY LINK W/ STANDOFF,OVERMOLD (Qty.1) 10 2 1.5" WALL FITTING, WATERWAY PN 400-9151, 213-9341,219-9191 BLACK WALL FITTING WITH NUT, GASKET, AND DIRECTIONAL EYEBALL (BLACK) 11 12 WATERWAY MINI STORM JET PNs: 228-0379 CPVC, 916-0024, 229-7921-LS JET - WATERWAY - MINI STORM THREAD 12 1 skimmer - Waterway - front access - 510-1501 square spa skimmer - 1-1/2" S / 2" spigot - flow control with trim plate 13 1 TOPSIDE CONTROL - BALBOA - SPA TOUCH 2T SPA TOUCH 2T - #57179 14 1 AUTOCOVER - COVERSTAR - KEYPAD NUMERIC KEYPAD COVER CONTROL 15 4 5/8" STAINLESS STEEL LIFTING EYEBOLT REMOVABLE RIGGING EYEBOLT WITH 4000LB VERTICAL LIFTING CAPACITY, MCMASTER PN 33045T83 SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 5 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 08/15/2022 09/29/2022 jimp 30.00 CLEARANCE REQUIRED FOR FILTER SERVICE 1721 1920 16 182223 NOTES: - SPA REQUIRES (1X)230V 30A GFCI SERVICE @ HYDROQUIP FOR CONTROL. - SPA REQUIRES (1X)230V 50A GFCI SERVICE @ HYDROQUIP FOR HEATER. - SPA SHELL AND ALL EQUIPMENT TO BE BONDED W/ MIN. #6AWG BARE COPPER CONDUCTOR. * MUST HAVE ACCESS AROUND ENTIRE PERIMETER OF AUTOCOVER BOX FOR FUTURE SERVICE NEEDS EQUIPMENT MUST BE LOCATED IN AN ENCLOSED VENTILATED AREA, PROTECTED FROM WEATHER - 6" FREE FROM FLAMABLE MATERIALS MUST BE MAINTAINEDAROUND GAS HEATER - DIRECT AIR INTAKE DUCT KIT AND FLUE COLLAR ADAPTER PROVIDED BY DSI - REFER TO MANUFACTURER INSTRUCTIONS AND LOCAL CODES FOR AIR INTAKE AND VENT INSTALLATION - Autofill requires 1/2" fresh water line with backflow and freeze protection located at equipment - GAS HEATER CONFIGURED FOR NATURAL GAS OPERATION EQUIPMENT LOCATION: - EQUIPMENT TO BE WITH FT OF SPA WITH AN ELEVATION CHANGE OF FT - INSTALLER TO VERIFY EQUIPMENT LOCATION ITEM NO.QTY.EQUIPMENT DESCRIPTION VOLTAGE HP / Amp NOTES 16 1 filter - Waterway - 100 sq/ft cartridge - 502-9910 100 sq.ft. cartridge filter w/ 1 gpm/sq.ft. filtration rate, mechanical bypass requires 54" vertical height to service/replace cartridge filter 17 1 pump - Waterway - Executive 56 - 4hp - 372162A-13 2-speed centrifugal pump and motor, 4 h.p., 130gpm @ 60 ft.TDH, 2 1/2" suction, 2" discharge 230 volt 4 h.p.- 4.4 amp / 12 amp 230V connection to control 18 1 pump - Waterway - Executive 56 - 2hp - 3720821-13 2 speed Centrifugal pump and motor, 2 h.p., 63gpm @ 60 ft.TDH, 2-1/2" suction, 2" discharge 230 volt 2 h.p. - 8 amp/3 amp 230V connection to control 19 1 HYDROQUIP REMOTE HEATER SYSTEM 11KW, OUTDOOR RATED HYDROQUIP P/N CS8800A 240V REQUIRES (1X) 50A GFCI BREAKER AND (1X) 50A GFCI BREAKER 2" UNIONS 20 1 AQUA UV STERILIZER PN A00507 25W UV sterilizer, 20gpm max flow rate, 2" union 120/240 < 1 amp 21 1 RGB LIGHT BALLAST 701678-DLO-TLA, SPA LED CONTROL-40, 2 POS, DAISY-LINK, OVERMOLD 22 1 MODEL NO. FLOVIS FV-C 2", NFS 50 APPROVED H2FLOW FLOVIS FLOW METER PN: FV-C 23 1 3 WAY JANDY VALVE W/ MANUAL VALVE LEVER 3WAY JANDY VALVE; 2.5" OUTSIDE 2" INSIDE PN: 4717 SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 6 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 08/15/2022 09/29/2022 jimp 2.00 4.00 2.00 SLOPE 2.00 SKIRT 84.00 96.00 32.00 TYP VE L C R O FO L D SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 7 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN SHEET OF DRAWN CHECKED UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. DO NOT SCALE DRAWING MATERIAL FINISH Rotary Hand Brushed w/Tile Prep THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF DIAMOND SPAS INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF DIAMOND SPAS INC. IS PROHIBITED. 4409 Coriolis WayFrederick, CO 80504ph. 720-864-9115 1-800-951-SPASfax. 1-866-605-2358 CR 3/17/2022CS 3/17/2022 7 7 304 / 316 L STAINLESS STEEL REVISION C HYDROSPA 4176 - ASPEN HANSEN FLOATING FOAM COVER *FLOATING COVERS DO NOT MEET SAFETY BARRIER REQUIREMENTS* NOTES: *PROJECTS WILL NOT BE SCHEDULED UNTIL COVER COLOR IS SELECTED* COVER MANUFACTURER MAINTAINS A -1.0" TOLERANCE ON OVERALL COVER DIMENSIONS *IF COVER COLOR IS NOT SELECTED AT TIME OF APPROVAL DEFAULT COVER COLORS WILL BE PROVIDED* NOTES: “10” adjustable strap locations are determined by cover manufacturer unless otherwise noted by client - Includes a minimum of 8 evenly distributed straps. Spa covers must be strapped down to a flat, level surface. Locking cover strap buckles will be provided and must be installed on site for ASTM compliance. Covers that exceed 108” in length will not be warrantied by the manufacturer against sagging, puddling, buckling or breakage” *IF COVER COLOR IS NOT SELECTED AT TIME OF APPROVAL DEFAULT COVER COLORS WILL BE PROVIDED* COVER MANUFACTURER MAINTAINS A +1.0" TOLERANCE ON OVERALL COVER DIMENSIONS DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 08/15/2022 09/29/2022 jimp Diamond Spas Inc 4409 Coriolis Way Frederick, CO 80504 (720) 864-9115 Fax 866-605-2358 Drawing Approval for Fabrication Project # __________________ Project ID: _____________________________________ Design Manager: ________________________ Drawing Revision: ____________ Drawing Date: ____________________ Total Pages in Drawing Set: __________ It is the responsibility of the purchaser to make sure that all products are in compliance with local codes and regulations. Certain jurisdictions may require additional testing and/or listing. It is also the responsibility of the client to arrange and pay for any permits, permit fees, inspections and inspection fees. Consult your local government agencies for additional information. Diamond Spas Inc reserves the right to change, amend and/or modify all or any part of the fabrication including but not limited to vessel and/or equipment design, equipment layout and/or components at any time without notice. Approval of the referenced drawings is acknowledgement of this notice and is legally binding. Diamond Spas Inc will not change the overall vessel design without prior written acknowledgement from client. Insulated Foam Cover Color Choice: __________________________________ Automatic Cover Color Choice: ________________________________________ Cover Color Link: https://www.diamondspas.com/swimming-pool-spa-collection/custom-spas-hot-tubs/spa-cover-colors/ Project Primary Contact: _______________________________________________________ Phone #: _________________________________________________________________________ Email: _____________________________________________________________________________ Project Installation Address: ___________________________________________________ ___________________________________________________ Project Installer: _________________________________________________________________ Phone #: __________________________________________________________________________ Email: _____________________________________________________________________________ I, __________________________ acknowledge that I have read, understand and approve the entirety of the drawing set; as outlined in "total pages in drawing set" above, as drawn. I further acknowledge I am the owner/purchaser or are a fully authorized agent acting on behalf of the owner, have the requisite authority to bind the owner and have informed the owner of the terms and conditions outlined above. Digital acknowledgements and signatures are legally binding. Signed: ___________________________________________________ Date: _____________________________ This may not be the ship to address Not Applicable Not Applicable DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 Light Gray sbarney@hansenconst.com 4176 695A S. Aspen Street (970) 920-1558x119 Sam Barney REV C Aspen Hansen jsansone@hansenconst.com 3/17/2022 7 4/5/2022 Hansen Construction Sam Barney Grey Aspen, CO CS (970) 309-6551 08/15/2022 09/29/2022 jimp Project # __________________ Project ID: _____________________________________ Design Manager: ________________________ Drawing Revision: ____________ Drawing Date: ____________________ Construct a crawl space a person can enter to make repair, minimum 18" wide Plan to construct removable panels to gain access Plan for a method to slide, move or hoist the vessel to gain access Plan for demolition to occur or gain access Plan to hoist vessel as necessary All service and repairs require access to the outside of the vessel. The purchaser accepts the related responsibility for the method of access selected as part of the architectural design, outside of the DSI scope of work. The referenced drawings do not include access unless it is part of the metal fabrication we provide. Diamond Spas Inc recommends a minimum vault of 18" wide surrounding vessel for future maintenance. The following access methods have been reviewed and considered: NOTE: Installer should test the vessel for leaks prior to completing surrounding finishes. Diamond Spas Inc 4409 Coriolis Way Frederick, CO 80504 (720) 864-9115 Fax 866-605-2358 Access Method Acknowledgement I, __________________________ acknowledge that I have read, understand and acknowledge my responsibility regarding future maintenance access. I further acknowledge I am the owner/purchaser or are a fully authorized agent acting on behalf of the owner, have the requisite authority to bind the owner and have informed the owner of the terms and conditions outlined above. Digital acknowledgements and signatures are legally binding. Signed: ___________________________________________________ Date: _____________________________ DocuSign Envelope ID: F7ED322F-41DC-4922-B605-EC04E16BE782 REV C CS Sam Barney 4/5/2022 4176 3/17/2022 Aspen Hansen 08/15/2022 09/29/2022 jimp