Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.855 Gibson Ave.0070-2020-BCHO (9)
LARGE SPAN SINGLE LIGHT SKYMAX STANDARD SIZES CUSTOM SIZES AVAILABLE Outside Curb Dim 58" x 58" 49¼ " x 72½ " 49¼ " x 92½ " Model No. GSM6060 GSM5276 GSM5296 Daylight Area (glass) 53¾ " x 53¾ " 45" x 68¼ " 45" x 88¼ " Daylight Sq. Ft. (glass) 20.06 21.32 27.58 For all rectangular units, specify dimension parallel to roof ridge first (for example, model GSM5276 would be either GSM5276 or GSM7652). Minimum 3½" curb height required. Not for vertical applications. *Dependent on use of lighting controls and other factors. Contact Wasco for more information. FIXED MODEL GSM Minimum of ¼ " in 12" Roof Pitch FINISH OPTIONS A baked enamel finish is standard on all models. We also offer anodized and high-performance designer color finishes; our most popular colors are shown below, approximated by printing inks. Copper cladding is also available. Quaker Bronze Black Copper Clad Bone White Aged CopperColonial White Interstate Green Sandstone Hartford Green Colonial Grey Brick Red STANDARD Double the Square Footage of Standard Flat Glass Skylights with the Same Thermal Efficiency Wasco’s dramatic new SkyMax doubles the square footage of our standard size flat glass unit skylights – without loss of thermal efficiency – at a fraction of the cost of structural skylights. SkyMax’s one piece extruded vinyl curb incorporates a condensation channel, eliminating the need for weep holes. This, combined with high-end glazing options, maximizes its thermal performance. • Single Light Up to 32 Square Feet—Ten Feet at Longest Dimension • Meets Most Local Energy Codes and Can Meet IECC in All Climate Zones* Twice the Light, Half the Cost e vinyl frame is structurally reinforced with aluminum. e elimination of weep holes increases thermal performance. The SkyMax’s vinyl frame is structurally reinforced with aluminum, allowing large single light spans of up to 32 square feet – as much as ten feet at the longest dimension – for breathtaking daylighting. wascoskylights.com SINGLE LIGHT UP TO32 SQ FT MADE IN USA 800-388-0293 csm@wascoproducts.com www.wascoskylights.com Eastern Facility: 85 Spencer Drive, Unit A, Wells, ME 04090 Western Facility: Reno, NV L559 4-17 12/23/2020 1° - 60° 1/4:12 – 20:12 VELUX SKYMAX installation instructions V4532-0519 Tools Needed Herramientas necesarias Installation instructions Instrucciones de instalaciónInstrucciones de instalación GSM 12/23/2020 VELUX America LLC 85 Spencer Drive, Unit A • Wells, ME 04090 Tel 1-800-888-3589 • wascoskylights.com • veluxusa.com V4532-0519 ©2018 VELUX Group ®VELUX, VELUX logo are registered trademarks 2 Safety Considerations While SkyMax skylights are designed to support the weight of snow, ice and the force of normal winds, they are not designed to withstand the weight of people. If human safety is a consideration, skylights should be protected by railings, grids, or screens. • Use suction cups when handling skylight. • Heavy object: Team lift required Every installation is unique and VELUX cannot control the conditions and the quality of the work that is done. VELUX assumes no responsibility for improper installation or noncompliance with all applicable building codes. Curb construction details a) Cut rough opening through roof deck. b) Frame under opening to match inside of skylight curb. Use double rafters and headers if necessary. c) Build curb from 2x4, 2x6, etc. Nail to roof deck. d) Shingle up to low side of curb. Detalles de construcción del guardaguas a) Corte una abertura no terminada a través del tejado. b) Enmarque bajo la abertura para que coincida en el interior del borde del tragaluz. Utilice cabezales y vigas dobles en caso necesario. c) Cimiente el borde a partir de 2x4, 2x6, etc. Clávelo al tejado. d) Cubra con tejas desde el lado superior al inferior del borde. 1 a Aspectos de Seguridad Aunque los tragaluces SkyMax han sido diseñados para soportar el peso de la nieve y el hielo, así como la fuerza de vientos normales, no están diseñados para soportar el peso de personas. Si la seguridad de las personas es motivo de consideración, los tragaluces deberán estar protegidos por barandillas, rejillas o mallas. • Use ventosas cuando levante. • Objeto pesado: se requiere elevación del equipo. Cada instalación es diferente y VELUX no puede controlar las condiciones ni la calidad del trabajo realizado. VELUX no asume ninguna responsabilidad por la instalación incorrecta o el incumplimiento de los códigos de construcción vigentes. b c d 12/23/2020 VELUX America LLC 85 Spencer Drive, Unit A • Wells, ME 04090 Tel 1-800-888-3589 • wascoskylights.com • veluxusa.com V4532-0519 ©2018 VELUX Group ®VELUX, VELUX logo are registered trademarks 3 Important Notes • Head flange width should be increased to 12" or more for roof pitches less than 5 in 12 • O.C. – Outside dimension of curb width • C.H. – Curb height • Dimensions are in inches • All bends are 90° Notas Importantes • La anchura de la ceja de cabecera debe aumentar a 12 o más si la pendiente del techo es menor que 5” (127 mm) por cada 12” (305 mm) • O.C. = Dimensión exterior de la anchura del borde • C.H. = Altura del borde • Las dimensiones se presentan en pulgadas • Todas las curvaturas son de 90° Flashing Construction Details Detalles de construcción del guardaguas Flashing Materials Thickness Copper 16 OZ Aluminum 0.040" Stainless Steel 26 GA Galvanized Steel 24 GA Materiales del Guardaguas Grosor Cobre 16 OZ Aluminio 0.040" Acero Inoxidable 26 GA Acero Galvanizado 24 GA Side Flashing Detail Detalle del guardaguas lateral Weld, braze or solder for a water-tight joint. Suelde, cobresuelde o estañosuelde para obtener una unión impermeable. Weld, braze or solder for a water-tight joint. Suelde, cobresuelde o estañosuelde para obtener una unión impermeable. 1 3 2 Bend up | Curve hacia arriba Bend down | Curve hacia abajo Cut in 1"Cut in 1" 7" 1 1"1" 7" 6" (12") O.C.+ 16" C.H.+ 1"O.C. O.C. + 2" 1 8" 8" 16" (20") C.H.+ 1" 2 – Bend up 3 – Bend down 2 3 2 – Curve hacia arriba 3 – Curve hacia abajo Head and sill detail Detalle del cabezal y el alféizar 8" 12" C.H.+ 1" Bend | Curve 4 4 2 12/23/2020 VELUX America LLC 85 Spencer Drive, Unit A • Wells, ME 04090 Tel 1-800-888-3589 • wascoskylights.com • veluxusa.com V4532-0519 ©2018 VELUX Group ®VELUX, VELUX logo are registered trademarks 4 Flashing the wood curb a) Install sill piece over shingles at bottom. Trim corners and bend over wooden curb. b) One side piece installed with each course of shingles and nailed to curb. Quantity varies with shingle exposure and length of unit. Bend over curb when installed. c) Step flash slides. Align flashing with bottom edge of shingle above it. d) Install head flashing. Trim corners and bend over wood curb. Guardaguas del borde de madera a) Instale la pieza fija sobre las tejas de la parte inferior. Recorte las esquinas y curve sobre el borde de madera. b) Una pieza lateral instalada con cada hilera de tejas y clavada para que se curve. La cantidad varía con la exposición de las tejas y la longitud de la unidad. Cúrvelo sobre el borde una vez instalado. c) El guardaguas por etapas se desliza. Alinee el guardaguas con el borde inferior de la teja que se encuentra sobre el mismo. d) Instale el guardaguas de la cabecera. Recorte las esquinas y cúrvelo sobre el borde de madera. Installing the unit e) Apply a bead of sealant around the top of the curb. f) Place unit on curb and attach with screws or nails using pre-drilled mounting holes. Instalación de la unidad e) Aplique un reborde de sellador alrededor de la parte superior del borde. f) Sitúe la unidad en el borde y únala con tornillos o clavos utilizando los orificios de montaje ya taladrados. 3 4 a b c d e f e f Cross section Sección transversal 12/23/2020 VELUX America, Inc. SkyMax Curb Mount (GSM) 08620 UNIT SKYLIGHTS 1 SECTION 08620 SKYMAX MODEL (GSM) GLASS GLAZED UNIT SKYLIGHT PART 1-GENERAL 1.1 SUMMARY A. This section includes the following: 1. Curb-mounted insulating glass glazed unit skylights. a. Model GSM with 1 1/16” insulating glass B. Related Sections: The following sections contain requirements that relate to this section: 1. Division Six Section “Rough Carpentry” for wood curbs and nailers. 2. Division Seven Section “Roof Accessories” for curbs, roof hatches, and smoke vents. 3. Division Seven Section “Flashing and Sheet Metal” for metal flashing for skylights. C. Refer to roofing system sections for roofing accessories to be built into the roofing system to accommodate work of this section. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide unit skylights capable of withstanding loads as defined by the local codes having jurisdiction where units are to be installed without failure. B. Units shall be tested to compliance with AAMA\WDMA\CSA\101\I.S.2\A440 as required by the International Building Code. C. Provide units tested to AAMA\WDMA\CSA\101\I.S.2\A440 with the following rating: SKG-PG80 1803 x 1803 (71 x 71). 1.3 SUBMITTALS A. Product Data Sheet: For each type of skylight specified, include details of construction and installation, relative to applicable roofing materials. B. Samples for Selection: Manufacturer’s color charts showing a full range of colors available for each type of skylight glazing and aluminum finish. 1.4 WARRANTY A. General: Warranties specified in this section shall not deprive the Owner of other rights the Owner may have under other provisions of the Contract Documents and shall be in addition to and run concurrent with other warranties made by the Contractor under requirements of the Contract Documents. B. Skylight Warranty: Provide written warranty signed by manufacturer, agreeing to repair or replace work that exhibits defects in materials or workmanship and guaranteeing weather-tight and leak-free performance. “Defects” is defined as uncontrolled leakage of water and abnormal aging or deterioration. 1. Warranty Period: 2 years from date of Substantial Completion. 12/23/2020 VELUX America, Inc. SkyMax Curb Mount (GSM) 08620 UNIT SKYLIGHTS 2 C. Glass Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work that has or develops defects in the insulating glass. “Defects” is defined as seal failure or delamination. 1. Warranty Period for Insulating Glass: 5 years from date of Substantial Completion. D. Finish Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work with finish defects. “Defects” is defined as peeling, chipping, chalking, fading, abnormal aging or deterioration, and failure to perform as required. (EDIT AS REQUIRED) 1. Warranty Period for Anodized Finish: 1 year from date of Substantial Completion. 2. Warranty Period for Powder Coat Finish: 5 years from date of Substantial Completion. 3. Warranty Period for Kynar 500 Finish: 5 years from date of Substantial Completion. (10 and 20 years available if specified) PART 2- PRODUCTS 2.1 MANUFACTURERS A. Manufacturers: Subject to compliance with requirements, provide products by VELUX America Inc., Greenwood, SC 29648; www.VELUXusa.com; (800) 878-3589, specifcations@VELUXusa.com. B. Substitutions: Manufactures shall not be considered without prior approval in writing no later than ten (10) calendar days prior to bid. Substitute manufacturers must have been in the custom skylight business for not less than a period of 15 years and must submit to the Architect the following: 1. List of similar projects successfully completed within the last five years. 2. Proof of financial capability. 3. Complete details of proposed skylight. 4. Complete specifications for Architect’s review. 2.2 MATERIALS A. Curb Frame: Bright white high performance PVC with Bronze cap stock and minimum effective external wall thickness of 0.060 inch (1.5mm). Provide integral condensation gutter system with corners fully welded for waterproof quality. B. Retainer Frame: Extruded aluminum alloy 6063-T5 (min). ASTM B 221 (ASTM B 221 M) with minimum effective thickness of 0.060 inch (1.5 mm). 1. Curbs: Minimum 1 ½” wide field built or pre-fabricated curb (By Others) C. Thermal Break: Fabricate skylight units with thermal chambered PVC frame. D. Fasteners: Same metal as metals being fastened, or nonmagnetic stainless steel or other non- corrosive metal as recommended by manufacturer. 2.3 INSULATING GLASS SKYLIGHT UNITS A. General: Factory-assembled, curb-mounted unit consisting of insulating glass, gasketing, and inner frame designed to mount on separate curb. 1. Products: Provide Model GSM meeting the requirements of this section. B. Curb: Minimum 1 ½” wide field built or pre-fabricated (By Others). C. Condensation Control: Fabricate skylight units with integral internal gutters to collect condensation. D. Thermal Break: Fabricate skylight units with thermal chambered PVC. E. Shape and Size: As indicated by model number. Custom sizes available, not to exceed 32 SF. F. Insulating Glass: 1 1/16” IG comprised of a ¼” tempered SB70XL on #2 surface, 3/8” air, and an inner pane of clear heat strengthened laminated glass. G. Optional 1 1/16” insulating glass available. Contact manufacturer. 12/23/2020 VELUX America, Inc. SkyMax Curb Mount (GSM) 08620 UNIT SKYLIGHTS 3 2.4 FABRICATION A. Framing Components: As follows: 1. Factory fit and assemble components. 2. Fabricate components that, when assembled, will have accurately fitted joints with ends coped or mitered to produce hairline joints free of burrs and distortion. 3. Fabricate components to accommodate expansion, contraction, and field adjustment, and to provide for minimum clearance and shimming at skylight perimeter. 4. Fabricate components to ensure that glazing is thermally and physically isolated from framing members. 5. Fit and secure PVC frame joints by thermal welding. 6. Fit and secure aluminum retainer joints with corner keys. 2.5 ALUMINUM FINISHES (EDIT AS REQUIRED) A. General: Comply with NAAMM “Metal Finishes Manual” recommendations for application and designations of finishes. B. Finish designations prefixed by AA conform to the system for designations of aluminum finishes established by the Aluminum Association. 1. Mill Finish: Manufacturer’s standard mill finish. 2. Clear-Anodized Finish, Class I: AA-C22A41 complying with AAMA 611. 3. Clear-Anodized Finish, Class II: AA-C22A31 complying with AAMA 611. 4. Color –Anodized Finish Class I: AA-C22A42/A44 complying with AAMA 611. Color:______________ 5. Kynar Fluoropolymer Two-Coat System: (70% PVDF) complying with AAMA 2605. Color:______________ (3coat and 4 coat available) 6. Powder Coat High-Performance Architectural Coating: comply with AAMA 2604. Color:______________ PART 3- EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with installer present, for compliance with requirements for installation tolerances and other conditions affecting skylight performance. 1. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Comply with manufacturer’s written instructions for protecting, handling, and installing skylight components. B. Coordinate with installation of roof deck and other substrates to receive skylight units. C. Coordinate with installation of vapor barriers, roof insulation, roofing, and flashing as required to assure that each element of the work performs properly and that combined elements are waterproof and weather tight. Anchor units securely to supporting structural substrates, adequate to withstand lateral and thermal stresses ass well as inward and outward loading pressures. D. Counter Flashing: Where counter flashing is required as component of the skylight, install to provide an adequate waterproof overlap with roofing or roof flashing (as counter flashing). Seal with thick bead of mastic sealant, except where overlap is indicated to be left open for ventilation. 3.3 CLEANING AND PROTECTION A. Clean exposed metal and glass surfaces according to manufacturer’s instructions during installation. Touch up damaged metal coatings. B. Final cleaning by others. END OF SECTION 12/23/2020 Date: Customer: Project: Location: Attention: ID #Notes Outboard: 5439 1/4" PPG Solarban® 70XL Low-E #2 a Air Space: 2 3/8" Spacer, (Argon Filled) Inboard: 40001 7/16" Clear Laminate d Outer Ply: 3/16" Clear Interlayer: 0.060" Clear PVB Inner Ply: 3/16" Clear Nominal Thickness:1.026 Inches f Performance Properties COG Results*Units Transmittance Visible Light 63 % Solar Energy 23 % Ultraviolet <1 % Reflectance Visible Light (Exterior)12 % Visible Light (Interior)13 % Solar Energy (Exterior)52 % Thermal Winter Nighttime U-factor/U-Value 0.24 Btu/hr-ft2-oF Summer Daytime U-factor/U-Value 0.24 Btu/hr-ft2-oF Shading Coefficient 0.31 - Solar Heat Gain Coefficient 0.27 - Relative Heat Gain 66 Btu/hr-ft2 Light to Solar Gain 2.33 - Notes:a) NFRC certified spectral data file b) Data generated by Oldcastle BuildingEnvelope™ c) Average solar data d) Simulated with LBNL Optics 5.1 e) Vendor supplied spectral data file f) Please reference ASTM C1036 and C1172 for allowable glass thickness variations May 23, 2014 Wasco Products *Vertically Glazed Center Of Glass (COG) Results Calculated Using LBNL Window 5.2 Software. LAMINATED INSULATING GLASS UNIT PERFORMANCE DATA Wells, ME Jeff Binette 12/23/2020