Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (18).ACBKCity of Aspen LOAD FORM -- APPLICATION FOR ELECTRIC SERVICE To be submitted by Electrical Designer or Electrical Contractor Please complete the following items in this checklist: ☐ Completed all sections of this form. ☐ Attached copies of the electrical one-line drawing and power plan. ☐ Upload this application on the City of Aspen Salesforce Applicant Portal. Contact Information Name of Person Submitting Request:_________________________________________________ Date:__________________ Company Name: __________________________________________________________________________________________ Phone Number:_________________________________ Email:___________________________________________________ Customer Information Billing Information Customer Name:_____________________________________ Mailing Address:_____________________________________ ___________________________________________________ Phone #:_____________ Email:________________________ City of Aspen Permit Number: _________________________ Bill To:_____________________________________________ Mailing Address:_____________________________________ ___________________________________________________ Phone #:______________ Email:________________________ Electrical Contractor Information Company Name:________________________________________________ Contact Person:______________________________ Phone #:____________________ Fax #:____________________ Email:______________________________________________ Location Information Service Address:____________________________________________________________________ Unit #:_________________ If this is part of a multi-occupancy building, give the building’s entire address range:_______________________________________________________________ ☐ New Construction ☐ Existing Structure ☐ Addition to Existing Structure ☐ Demolition Within City Limits? ☐ Yes ☐ No Type of Building: ☐ Single Occupancy ☐ Multi-Occupancy ☐ Multi-Occupancy Core and Shell Only ☐ Multi-Occupancy Residential Request Type ☐ New service ☐ Increase Existing Service Entrance Size (with no service upgrade) ☐ Remove Existing Meter(s), service to remain ☐ Modification of Existing Tenant Space(s) ☐ Upgrade Existing Service ☐ Add New Meter to Existing Service (with no service upgrade) ☐ Remove Existing Meter(s) and Service ☐ Other__________________________________________________ Electrical Load Information New Equipment Load New Equipment Load HVAC Equip. (Tons)_____ _____ Tot. KW X-Ray Equipment _____KW Refrigeration Equip. (Tons)_____ _____ Tot. KW Washer/Dryer(s) _____KW Electric Heat _____KW Machinery #:_____HP:_____ _____ Tot. HP Water Heating _____KW Exhaust Fans #:_____HP:_____ _____ Tot. HP Lighting _____KW Pumps #:_____HP:_____ _____ Tot. HP Outlets _____KW Small Motors #:_____HP:_____ _____ Tot. HP Office Equipment _____KW Compressors #:_____HP:_____ _____ Tot. HP Kitchen Equipment _____KW Miscellaneous _____KW Computers _____KW _____KW Snow Melting Equipment _____KW _____KW Thermoplastic Injection Equip. _____KW _____KW Boiler _____KW Future Equipment _____KW Elevators _____KW (Itemize on separate sheet) Signs _____KW Total HP TOTAL: KW APPLICATION FOR ELECTRIC SERVICE Page 2 ELECTRIC VEHICLE (X5) GROUND WATER & CONDENSER PUMPS ELECTRIC VEHICLE CHARGER (X1) HEATING/COND PUMPS Service Information Existing Service Information New Service Information ☐ N/A – No Existing Service at this location ☐ N/A – Existing Service, Service Entrance will remain unchanged Service Type:______________________________________________ Transformer Number:_______________________________________ Transformer Size:_______________________________________ Kva Service Type:______________________________________________ Service:___________________________________________________ _________________________________________________________ Voltage: __________________________________________________ Voltage: __________________________________________________ Service terminates in:________________________________________ Service Entrance Size: Amps Service terminates in:________________________________________ Service Entrance Size: Amps Conductors/phase:___________ Conductor Size:_________________ Conduits: Number: Size:__________________________ Conductors/phase:___________ Conductor Size:_________________ Conduits: Number:__________ Size:__________________________ Cables: Quantity:___________ Solar: ☐ Yes ☐ No Cables: Quantity:___________ Solar: ☐ Yes ☐ No Meter Information Existing Meter Information New Meter Information N/A – No Existing Meters at this location For multi-occupancy buildings, list all meters connected to this service:___________________________________________________ _________________________________________________________ _________________________________________________________ N/A – Existing Meters, Service will remain unchanged For multi-occupancy buildings, tenant meters will only be installed for spaces being finished under this permit. Core and Shell only projects will only receive a house meter on the C&S permit. Max. Potential # of Meters at Build out: _______COM _______Res Meter Number: Size: Meter Will: Size and Number of New Meters Being Requested _____________ _______Amps ☐ Remain ☐ Be Removed Commercial Meters Residential Meters _____________ _______Amps ☐ Remain ☐ Be Removed _____________ _______Amps ☐ Remain ☐ Be Removed ______Ph ____ W____/___V ______Ph ____ W____/___V _____________ _______Amps ☐ Remain ☐ Be Removed _____________ _______Amps ☐ Remain ☐ Be Removed Number of Meters Needed: Number of Meters Needed: _____________ _______Amps ☐ Remain ☐ Be Removed ______@__________Amps ______@__________Amps _____________ _______Amps ☐ Remain ☐ Be Removed ______@__________Amps ______@__________Amps _____________ _______Amps ☐ Remain ☐ Be Removed _____________ _______Amps ☐ Remain ☐ Be Removed _____________ _______Amps ☐ Remain ☐ Be Removed ______@__________Amps ______@__________Amps ______@__________Amps ______@__________Amps ______@__________Amps ______@__________Amps CUSTOMER SIGNATURE AND ADDITIONAL INFORMATION LOAD DATA MUST BE AS COMPLETE AS POSSIBLE. COST OF CHANGES DUE TO INADEQUATE/INACCURATE INFORMATION WILL BE BORNE BY HE PROPERTY OWNER OR ELECTRICIAN. LOAD DATA FORMS WITHOUT PLANS MAY BE DELAYED AND/OR NOT PROCESSED. SITE GRADING, UTILITY, AND LANDSCAPING PLANS ARE REQUIRED WHEN PRIMARY ELECTRICAL EXTENSIONS ARE NECESSARY. NOTE: A METER WILL NOT BE INSTALLED UNTIL THE PERSON FINANCIALLY RESPONSIBLE FOR THE BILLING HAS SET UP AN ACCOUNT WITH THE CITY OF ASPEN’S UTILITY BILLING DPEARTMENT, LOCATED AT 130 S. GALENA ST., ASPEN, CO 81611, PHONE # 970.920.5030. FORM WILL NOT BE PROCESSED WITHOUT SIGNATURE. Signature of Authorized Party:________________________________________________________________ Date:_______________________ For City of Aspen Use Only City of Aspen Electric Utility Approved by (print name):____________________________________________________________ Signature of City Approver:________________________________________________________ Date:____________________ City of Aspen Electric Department - Phone: 970.920.5148 G J 3 4 20 T45P T45S 21 5 22 24 T45P T45S 25 26 27 28 7 #3/0 BLDG STEEL AND WATER ENTRY FEEDER SCHEDULEFEEDER SCHEDULE TRANSFORMER FEEDER SCHEDULE 600D 800D 1000D 1200D ELEV 45D (3#6+#10G)1"C 400D 450D 500D 350D 300D 175D 225D 250D 200D 110D 90D 125D 150D 100D 80D 60D 70D 50D (3-350KCMIL+#4G)2-1/2"C (3-500KCMIL+#3G)3"C (3-250KCMIL+#4G)2-1/2"C (3#2/0+#6G)2"C (3#4/0+#4G)2"C (3#3/0+#6G)2"C (3#1+#6G)1-1/2"C (3#2+#8G)1-1/4"C (3#1/0+#6G)1-1/2"C (3#1+#6G)1-1/2"C (3#1+#8G)1-1/2"C (3#3+#8G)1-1/4"C (3#4+#10G)1-1/4"C (3#4+#8G)1-1/4"C (3#6+#10G)1"C WIRE AND CONDUIT SIZE - 3∅, 3W 35D 40D 30D (3#8+#10G)3/4"C (3#8+#10G)3/4"C (3#10+#10G)3/4"C (3#10+#10G)3/4"C 4[(3-350KCMIL+#3/0G)3"C] 3[(3-400KCMIL+#2/0G)2-1/2"C] 3[(3-300KCMIL+#1/0G)2-1/2"C] 2[(3-250KCMIL+#2G)2-1/2"C] 2[(3-350KCMIL+#1G)2-1/2"C] 2[(3#4/0+#2G)2"C] 2[(3#3/0+#3G)2"C] 2500Y 3000Y 4000Y 800Y 1000Y 1200Y 1600Y 2000Y 11[(4-500KCMIL+500KCMIL G)4"C] 8[(4-500KCMIL+400KCMIL G)3-1/2"C] 7[(4-500KCMIL+350KCMIL G)3-1/2"C] 6[(4-400KCMIL+250KCMIL G)3"C] 5[(4-400KCMIL+#4/0G)3"C] 4[(4-350KCMIL+#3/0G)3"C] 3[(4-400KCMIL+#2/0G)3"C] 3[(4-300KCMIL+#1/0G)2-1/2"C] 175Y 350Y 400Y 450Y 500Y 600Y 300Y 225Y 250Y 200Y 110Y 125Y 150Y 100Y 90Y 80Y 60Y 70Y 50Y (4#2/0+#6G)2"C 2[(4-250KCMIL+#2G)2-1/2"C] (4-350KCMIL+#4G)3"C (4-500KCMIL+#3G)3"C 2[(4-350KCMIL+#1G)3"C] (4-250KCMIL+#4G)2-1/2"C (4#4/0+#4G)2-1/2"C 2[(4#4/0+#2G)2"C] 2[(4#3/0+#3G)2-1/2"C] (4#3/0+#6G)2"C (4#2+#8G)1-1/4"C (4#1+#6G)1-1/2"C (4#1/0+#6G)2"C (4#1+#6G)1-1/2"C (4#1+#8G)1-1/2"C (4#3+#8G)1-1/4"C (4#4+#10G)1-1/4"C (4#4+#8G)1-1/4"C (4#6+#10G)1"C WIRE AND CONDUIT SIZE - 3∅, 4W 45Y 35Y 40Y 30Y (4#6+#10G)1"C (4#8+#10G)1"C (4#8+#10G)1"C (4#10+#10G)3/4"C 1600U 5[(4-400KCMIL)3"C] + (1)4"C SPR MECH REFER TO MECHANICAL SCHEDULE WIRE AND CONDUIT SIZE - 3∅ 3[(4-400KCMIL+#3/0G)3"C] (4#1/0+#6G)2"C (3#3+#8G)1-1/4"C 2[(3#4/0+#2G)2"C] T300S T300P T45S T45P (4#2+#8G)1-1/4"C (3#6+#10G)1"C T30S T30P ELEV-R (4#4+#8G)1"C U 1 6 2 16 89 10 11 13 14 18 19 15 23 1-1/2"C 1-1/2"C 1-1/2"C 1-1/2"C 17 (4#2+#6G)1 1/4"C (4#2+#6G)1 1/4"C (4#2+#6G)1 1/4"C MSP D SP D M M MIDDLE LEVEL MAIN LEVEL ROOF BASEMENT LEVEL UPPER LEVEL CITY OF ASPEN ELECTRICAL UTILITY PADMOUNT TRANSFORMER WITH PRECAST TRANSFORMER VAULT BY EC. PER COA REQUIREMENTS 1. PROVIDE DEMAND METERS, COMPATIBLE WITH METERING SYSTEM, TO MONITOR PANEL AND EQUIPMENT AS NOTED. PROVIDE SIZE AS REQUIRED FOR METERED PANEL. COORDINATE AND VERIFY EXACT TYPE WITH OWNER PRIOR TO ORDERING. 2. REFER TO OWNER EQUIPMENT SCHEDULE ON E6.0 FOR FEEDER SIZE. 3. PROVIDE ARC FLASH ENERGY REDUCTION PER NEC 240.87. 4. PROVIDE 250KW/312KVA NATURAL GAS STANDBY GENERATOR. DERATE FOR ALTITUDE. REFER TO E7.1 FOR CALCULATIONS. 5. ELECTRICAL CONTRACTOR TO PROVIDE CONNECTION TO LINE SIDE OF EACH UPS. UPSs ARE PROVIDED BY OWNER A. LOCAL ELECTRICAL UTILITY IS COA (CITY OF ASPEN UTILITY). ELECTRICAL CONTRACTOR TO MEET COA REQUIREMENTS FOR INSTALLATION. B. GENERATOR MUST MEET OR EXCEED THE CALIFORNIA SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT REQUIREMENTS TO ACHIEVE WELL BUILDING POINT. C. PROVIDE BACKFED TYPE BREAKERS WHERE REQUIRED FOR PV SYSTEM. ONE-LINE DIAGRAM FLAG NOTES: ONE-LINE DIAGRAM GENERAL NOTES: 1 4 3 2 1 5 5 1 M PANEL LB PANEL M1 PANEL L1 PANEL M2 PANEL L2 PANEL M3 PANEL L3 PANEL SB PANEL MB PANEL SL3 PANEL SLB PANEL MBA PANEL MDFA SOLAR COLLECTOR PANEL UTILITY PRIMARY 1600U NEMA 3R OUTDOOR SERVICE ENTRY - MSD1 1600A, 480Y/277V, 3PH, 4W 1600A 3P 1600Y BASEMENT POWER AND LIGHTING ELEV 450A 3P ELEV MAIN SWITCHBOARD MSB1-1600A, 480Y/277V, 3PH, 4W ELEV CONTROLLER N G #4 UFER MAIN MECHANICAL MAIN POWER AND LIGHTING MIDDLE MECHANICAL MIDDLE POWER AND LIGHTING UPPER MECHANICAL UPPER POWER AND LIGHTING 30A 3P 400A SPACE 60A 3P 60Y 25A 30AF 400A 3P ATS 400A3P 400Y 400Y 400A3P 250A 3P 250Y BASEMENT MECHANICAL SPACES: (3) 200A3P (3) 100A3P 400Y ELEV #6 GROUND ROD 100Y 200A 3P 400A 3P 200Y 400Y 400A 3P 200A 3P 400Y 200Y LBDP, 1000A-208Y/120V, 3PH, 4W 1000A MCB T-LBDP 300 KVA 480V-120/208 T-SLB 45 KVA 480V-120/208 T300S T300P 400A 3P 400Y 400A 3P 400Y 200A 3P 200Y 100A 3P E-4 100A SPACE 100A SPACE 100A SPACE 100A SPACE FUTURE CAR CHARGER RE: E1.0 FUTURE CAR CHARGER RE: E1.0 FUTURE CAR CHARGER RE: E1.0 FUTURE CAR CHARGER RE: E1.0 GFCI 60A 3P 60Y #3/0G #6G 90A 3P 150Y BASEMENT MECHANICAL T-MDFA 45 KVA 480V-120/208 #8G 100A 90AF UPPER POWER AND LIGHTING UPS-A UPS-B 90Y 90Y 3P 70A ELEV-R 70A 100AF ELEV-R ELEV-RIO ELEV CONTROLLER 30 FAULT CURRENT CALCULATIONS Maximum Available Fault Current (IAIC) I SCA = (I AIC x M) Where M = 1 / (1+f), and f = (1.732 x L x I AIC) / (C x n x E) Po i n t Fault Location Le n g t h , f e e t Co n d u c t o r s si z e # co n d u c t o r s pe r p h a s e Cu (1) Al (2)Co n d u i t Ma g n e t i c ( 1 ) No n m a g n . ( 2 ) Vo l t a g e Ph a s e "C" Value Pr e v i o u s fa u l t v a l u e Fault value U Service Transformer Secondary Winding per CCA 20,200 1 OUTDOOR SERVICE ENTRY 10 400 5 1 2 480 3 24296 20,200 20,080 2 MSB1 50 400 5 1 2 480 3 24296 20,080 19,498 3 T-LBDP 5 "4/0" 2 1 1 480 3 15082 19,498 19,273 5 PANEL LBDP 5 400 3 1 1 208 3 20565 17,091 16,896 6 PANEL LB 15 "3/0" 1 1 1 208 3 12843 16,896 14,511 7 SOLAR COLLECTOR PANEL 60 2 1 1 1 208 3 5906 16,896 6,955 8 PANEL M1 50 "3/0" 2 1 1 208 3 12843 16,896 13,264 9 PANEL L1 50 "3/0" 2 1 1 208 3 12843 16,896 13,264 10 PANEL M2 50 "3/0" 2 1 1 208 3 12843 16,896 13,264 11 PANEL L2 50 "3/0" 2 1 1 208 3 12843 16,896 13,264 13 PANEL M3 60 "3/0" 2 1 1 208 3 12843 16,896 12,717 14 PANEL L3 60 "3/0" 2 1 1 208 3 12843 16,896 12,717 15 PANEL MB 10 250 1 1 1 480 3 16483 19,498 18,700 16 ELEV-1 GALENA 25 10 1 1 1 480 3 981 19,498 6,981 17 PANEL MBA 130 "1/0" 1 1 1 480 3 8924 17,674 9,162 18 ATS-SB 70 300 3 1 1 480 3 18176 19,498 17,883 19 PANEL SB 10 300 3 1 1 480 3 18176 17,883 17,674 20 T-SLB 5 "3/0" 1 1 1 480 3 12843 17,674 17,246 22 PANEL SLB 10 "3/0" 1 1 1 208 3 12843 3,769 3,679 23 PANEL SL3 60 300 3 1 1 208 3 18176 3,679 3,559 24 T-MDFA 25 3 1 1 1 480 3 4760 17,674 13,239 26 PANEL MDFA 5 "1/0" 1 1 1 208 3 8924 3,664 3,603 27 UPS-A 20 2 1 1 1 208 3 5906 3,603 3,270 28 UPS-B 5 2 1 1 1 208 3 5906 3,603 3,513 For Second Transformer: f = ( I SCA pri x E PRI x 1.732 x (%Z)) / (100000 x KVA) I SCA sec = (E pri x M x I SCA pri) /E sec Po i n t Fault Location Size, kVA Pr i m a r y vo l t a g e , V Se c o n d a r y Vo l t a g e , V %Z Ph a s e Pr e v i o u s f a u l t va l u e Fault value 4 T-LBDP 300.0 480 208 3 3 19,273 17,091 21 T-SLB 45.0 480 208 3 3 17,246 3,769 25 T-MDFA 45.0 480 208 3 3 13,239 3,664 CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. IMEG Corp 7600 E. Orchard Rd. Suite 250-S Greenwood Village, CO 80111 p: 303-796-6000 f: 303-796-6099 IMEG Proj. No.: 2016.01.0223 11 / 1 2 / 2 0 2 0 1 0 : 2 8 : 5 1 A M E4.0 2016.01.0223 ELECTRICAL ONE LINE DIAGRAM AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O ISSUE: DATE: ASI 009 03/05/20 100%DD INT 4/3/20 Permit CO #02 4/17/20 Permit CO #03 4/24/20 100%CD INT 5/22/20 PERMIT INT 6/11/20 RIO VE REVISIONS 11/13/20 30 RFI 183 RFI 183 J E {LS19} {LS19} {LS19} E 600 L1- 2 L1- 2 L1- 2 L1- 2 SC L3- 4 602 SD SD SD SD 202 ELEC RM 605 604604 MSB1-8,10,12 E-4 119 120 120 Z61 Z62 Z62Z62 Z62 SC 605 L3-4 Z60 608 608 M3-14 HEAT TRACE M3-14 HEAT TRACE 31 CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. IMEG Corp 7600 E. Orchard Rd. Suite 250-S Greenwood Village, CO 80111 p: 303-796-6000 f: 303-796-6099 IMEG Proj. No.: 2016.01.0223 11 / 1 7 / 2 0 2 0 9 : 4 8 : 1 8 A M E1.0 2016.01.0223 ELECTRICAL SITE PLAN AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O 1" = 20'-0"1 ELECTRICAL SITE PLAN FLAG NOTES (THIS SHEET) 119 TYPICAL OF (32) FIXTURES, SEE LANDSCAPE PLANS FOR MOUNTING DEATILS AND EXACT LOCATIONS. 120 SEE LANDSCAPES DRAWINGS FOR MOUNTING DETAILS AND EXACT LOCATIONS. 202 PROVIDE FOUR-(4) 4" SERVICE ENTRANCE CONDUITS WITH PULL WIRES FOR TELEPHONE, DATA, AND CATV AS NEEDED FROM THE TELECOM/DATA ROOM TO THE NEAREST UTILITY PEDESTAL OR MANHOLE AS DIRECTED BY VENDOR. ROUTE CONDUITS IN TO BASEMENT LEVEL CEILING SPACE. COORDINATE AND VERIFY EXACT ROUTING OF CONDUIT AND LOCATION OF PEDESTAL OR MANHOLE PRIOR TO INSTALLATION. 600 SEE SHEET E3.1 FOR ELECTRIC SERVICE DETAILS. 602 PHOTOVOLTAIC SYSTEM TO BE DESIGNED BY OTHERS. 604 PROVIDE (4#1+#8G)1-1/2"C FROM MAIN ELECTRICAL ROOM AND (1) 1-1/2" SPARE CONDUIT FROM DATA CENTER ROOM IN BASEMENT FOR CAR CHARGING STATION. COORDINATE EXACT REQUIREMENTS WITH OWNER'S VENDOR. 605 PROVIDE (2) 1-1/2" CONDUITS STUBBED FROM MAIN ELECTRICAL ROOM AND (2) 1-1/2" CONDUITS STUBBED FROM DATA CENTER ROOM IN BASEMENT TO PARKING LOT FOR FUTURE CAR CHARGING STATIONS. 608 PROVIDE (1) 1" CONDUIT STUBBED FROM MAIN ELECTRICAL ROOM IN BASEMENT TO PARKING LOT FOR FUTURE PARKING LOT LIGHTS. ISSUE: DATE: Permit CO #03 4/24/20 100%CD INT 5/22/20 PERMIT INT 6/11/20 RFI #312 8/7/20 RFI 341 11/09/20 BCHO COMMENTS 11/09/20 RFI 473 11/17/20 GENERAL NOTES (LIGHTING) A WHERE LUMINAIRE QUANTITIES OR LAYOUT DIFFER BETWEEN ARCHITECTURAL REFLECTED CEILING PLANS AND ELECTRICAL LIGHTING PLANS, HIGHER QUANTITY SHALL TAKE PRECEDENCE. CONTRACTOR SHALL CONFIRM QUANTITY AND LAYOUT WITH DESIGN TEAM. B ALL FIXTURES LABELED 'E' OR SHOWN SHADED SHALL BE CONTROLLED WITH OTHER NORMAL POWER LUMINAIRES IN THEIR ASSIGNED ZONE UNDER NORMAL POWER. DURING LOSS OF NORMAL POWER ALL LUMINAIRES LABELED 'E' OR SHOWN SHADED SHALL BE POWERED FROM THE INTEGRAL OR REMOTE MOUNTED BATTERY BALLAST COMPATIBLE WITH FIXTURE AND PROVIDE 100% LIGHT OUTPUT. PROVIDE EMERGENCY ILLUMINATION OF NO LESS THAN 1 FOOTCANDLE AVERAGE (0.1FC MIN) IN THE PATH OF EGRESS FOR EMERGENCY EVENTS PER NFPA. PROVIDE AUTOMATIC SELF-TESTING EMERGENCY POWER UNITS. C ALL DRAWINGS ARE DIAGRAMMATICAL ONLY. SYMBOLS ARE NOT NECESSARILY TO SCALE. USE ARCHITECTURAL PLANS FOR DIMENSIONS. IF THESE DRAWINGS DIFFER SUBSTANTIALLY FROM ARCHITECTURAL DRAWINGS, NOTIFY ARCHITECT IMMEDIATELY FOR A RESOLUTION. D ALL EXIT SIGNS ARE TO BE CONNECTED TO LOCAL LIGHTING CIRCUIT AHEAD OF LOCAL SWITCHING. E #B PUSH BUTTON REFERS TO SCENE QUANTITY. COORDINATE NUMBER OF BUTTONS FOR CONTROL STATIONS WITH LIGHTING CONTROL MANUFACTURER. CONTROL SHALL BE CAPABLE OF DIMMING UP/DOWN AND SWITCHING ON/OFF FOR MULTIPLE ZONES AS INDICATED AND PER LIGHTING SEQUENCE OF OPERATIONS F Z## INDICATES ZONING AND REFLECTS A LIGHTING CONTROL GROUP. PROVIDE RELAYS AS REQUIRED TO ALLOW LUMINAIRES WITHIN THE DEFINED ZONE TO FUNCTION TOGETHER DURING NORMAL POWER. G {L##} DENOTES LIGHTING SEQUENCE OF OPERATIONS. REFER TO SHEET E6.0 FOR LIGHTING CONTROL SEQUENCE OF OPERATIONS SCHEDULE. H REFER TO SHEET E6.1 FOR LUMINAIRE SCHEDULE. I SENSORS SHOWN ARE FOR REFERENCE ONLY. REFER TO LIGHTING CONTROL SEQUENCE OF OPERATIONS. PROVIDE QUANTITY, LOCATE AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. PROVIDE APPROPRIATE SENSORS TO COVER AT MINIMUM 90% OF THE SPACE INDICATED J COORDINATE LUMINAIRE LOCATIONS AND MOUNTING WITH ALL EQUIPMENT, DEVICES, CONDUIT, AND DUCTS. RFI 109 RFI 220 RFI 341