Loading...
HomeMy WebLinkAboutFile Documents.230 E Hopkins Ave.0046-2020-BCHO (17)P 303.296.9696 | W dalyteusa.com | 290 E 56th Ave., Denver, CO 80216 FLAT GLASS/FLASHING MODEL #OUTSIDE CURB DIMENSIONS 2424 GLS 25-1/2” x 25-1/2” 2424 FLASHING 25-1/2” x 25-1/2” 2448 GLS 25-1/2” x 49-1/2” 2448 FLASHING 25-1/2” x 49-1/2” 4848 GLS 49-1/2” x 49-1/2” 4848 FLASHING 49-1/2” x 49-1/2” SUMMIT SERIES™ CURB MOUNT FIXED SKYLIGHTS 2X4 2X2 DĀLYTE Skylights are Designed, Built and Storm Tested in the Rocky Mountain Region Since 1977 DĀLYTE offers standard and custom sizes of Low-E Flat-Glass skylights. Our skylights include thermally-broken aluminum frames for higher energy efficiency. Professional Grade materials including welded heavy gauge aluminum frames come standard. Our skylights are easy to install with built-in tolerances for out of square curbs. FEATURES •Dark Bronze anodized exterior frame •Includes Curb Mount Installation Kit with curb tape and screws •Glazing: –Low-E clear/clear with laminated inner layer for safety and exterior protection film OPTIONAL ADD-ONS •Self-flashing/deck mount •Flashing kits •Clear anodized exterior frame •Multi-wall polycarbonate: clear, bronze & white 04/05/2021 HOW TO MEASURE A CURB DĀLYTE designs, constructs and installs architectural and structural skylights that welcome the sky in, creating stunning spaces. A single source of responsibility means your project is handled by our expert team from initial design through installation. Design your sky with DĀLYTE. Outside Curb Dimension New Exposed Curb OUT S I D E C U R B D I M E N S I O N OU T S I D E C U R B D I M E N S I O N • Always measure the outside curb dimension...not the skylight frame • DĀLYTE adds 5/8” standard clearance on ALL sides which is in addition to the outside curb dimensions • If possible, outside curb dimensions should be taken on the exposed curb • The 5/8” clearance is for the roofing materials, flashing and out-of-square curbs 04/05/2021 PLAN ISOSINGLE SLOPE CURB MOUNT SINGLE SLOPE with FLAT GLASS CURB MOUNT with FLAT GLASSFax (303) 296-2146 D LYTE An AiA Industries Company 290 East 56th Avenue Denver, CO 80216 v (303) 296-9696 04/05/2021 HEAD CURB MOUNT SINGLE SLOPE Fax (303) 296-2146 D LYTE An AiA Industries Company 290 East 56th Avenue Denver, CO 80216 v (303) 296-9696 04/05/2021 CURB MOUNT SINGLE SLOPE SILLFax (303) 296-2146 D LYTE An AiA Industries Company 290 East 56th Avenue Denver, CO 80216 v (303) 296-9696 04/05/2021 END RAFTER CURB MOUNT SINGLE SLOPE Fax (303) 296-2146 D LYTE An AiA Industries Company 290 East 56th Avenue Denver, CO 80216 v (303) 296-9696 04/05/2021 04/05/2021 1-888-PPG-IDEA (1-888-774-4332) www.ppgideascapes.com 27 One-Inch Insulating Glass Unit Comparisons with PPG Glass Coated Insulating Glass Unit Performance Comparisons 1-inch (25mm) units with 1/2-inch (13mm) air fill and two 1/4-inch (6mm) lites; interior lite clear unless otherwise noted SOLARBAN ® 70XL Solar Control Low-E Glass† SOLARBAN 70XL (2) + Clear 6 64 25 12 13 0.28 0.26 1.5 0.32 0.27 2.37 SOLARBAN 70XL (2) SOLEXIA + Clear 4 58 21 10 13 0.28 0.26 1.5 0.31 0.27 2.15 SOLARBAN 70XL (2) ATLANTICA + Clear 2 51 17 9 12 0.28 0.26 1.5 0.28 0.24 2.13 SOLARBAN 70XL (2) AZURIA + Clear 5 52 18 9 12 0.28 0.26 1.5 0.29 0.25 2.08 SOLARBAN 70XL (2) PACIFICA + Clear 2 32 12 6 12 0.28 0.26 1.5 0.22 0.19 1.68 SOLARBAN 70XL (2) SOLARBLUE + Clear 4 42 17 8 12 0.28 0.26 1.5 0.26 0.23 1.83 SOLARBAN 70XL (2) SOLARBRONZE + Clear 3 40 15 7 12 0.28 0.26 1.5 0.25 0.21 1.90 SOLARBAN 70XL (2) OPTIGRAY + Clear 4 47 18 8 12 0.28 0.26 1.5 0.28 0.24 1.96 SOLARBAN 70XL (2) SOLARGRAY + Clear 3 34 13 6 12 0.28 0.26 1.5 0.23 0.20 1.70 SOLEXIA + SOLARBAN 70XL (3) 3 56 20 11 12 0.28 0.26 1.5 0.37 0.32 1.75 ATLANTICA + SOLARBAN 70XL (3) 2 49 17 10 11 0.28 0.26 1.5 0.32 0.28 1.75 AZURIA + SOLARBAN 70XL (3) 4 49 17 9 11 0.28 0.26 1.5 0.33 0.29 1.69 PACIFICA + SOLARBAN 70XL (3) 2 31 12 6 10 0.28 0.26 1.5 0.26 0.22 1.41 SOLARBLUE + SOLARBAN 70XL (3) 3 40 16 8 11 0.28 0.26 1.5 0.32 0.27 1.48 SOLARBRONZE + SOLARBAN 70XL (3) 3 38 15 8 11 0.28 0.26 1.5 0.30 0.26 1.46 OPTIGRAY + SOLARBAN 70XL (3) 3 45 17 9 11 0.28 0.26 1.5 0.33 0.29 1.55 SOLARGRAY + SOLARBAN 70XL (3) 2 32 13 7 11 0.28 0.26 1.5 0.27 0.24 1.33 GRAYLITE II + SOLARBAN 70XL (3) 0 6 3 4 10 0.28 0.26 1.5 0.13 0.11 0.55 SOLARBAN ® 72 Solar Control Low-E Glass SOLARBAN 72 (2) STARPHIRE †† 9 71 28 13 13 0.29 0.27 1.5 0.34 0.30 2.37 SOLARBAN ® z50 Solar Control Low-E Glass†† † SOLARBAN z50 (2) OPTIBLUE + Clear 14 51 25 8 11 0.29 0.27 1.6 0.36 0.32 1.59 SOLARBAN z50 (2) OPTIBLUE + OPTIBLUE 11 37 20 7 8 0.29 0.27 1.6 0.35 0.31 1.19 SOLARBAN ® z75 Solar Control Low-E Glass†† † SOLARBAN z75 (2) OPTIBLUE + Clear 6 48 19 9 12 0.28 0.26 1.5 0.28 0.24 2.00 SOLARBAN ® R100 Solar Control Low-E Glass SOLARBAN R100 (2) + Clear 12 42 19 32 14 0.29 0.27 1.6 0.27 0.23 1.83 SOLARBAN R100 (2) STARPHIRE + STARPHIRE 16 44 21 33 14 0.29 0.27 1.6 0.27 0.23 1.91 SOLARBAN R100 (2) SOLEXIA + Clear 6 36 15 25 13 0.29 0.27 1.6 0.24 0.21 1.71 SOLARBAN R100 (2) ATLANTICA + Clear 3 32 12 20 13 0.29 0.27 1.6 0.22 0.19 1.68 SOLARBAN R100 (2) AZURIA + Clear 8 32 12 21 13 0.29 0.27 1.6 0.22 0.19 1.68 SOLARBAN R100 (2) OPTIBLUE + Clear 8 30 14 19 13 0.29 0.27 1.6 0.23 0.20 1.50 SOLARBAN R100 (2) PACIFICA + Clear 3 20 9 11 13 0.29 0.27 1.6 0.19 0.16 1.25 SOLARBAN R100 (2) SOLARBLUE + Clear 6 26 12 15 13 0.29 0.27 1.6 0.22 0.19 1.37 SOLARBAN R100 (2) SOLARBRONZE + Clear 5 25 11 15 13 0.29 0.27 1.6 0.21 0.18 1.39 SOLARBAN R100 (2) OPTIGRAY + Clear 6 29 13 18 13 0.29 0.27 1.6 0.22 0.20 1.45 SOLARBAN R100 (2) SOLARGRAY + Clear 5 21 10 12 13 0.29 0.27 1.6 0.19 0.17 1.24 Glass Type +Outdoor Lite: Coating if Any (Surface) Glass Indoor Lite: Coating if Any (Surface) Glass Transmittance 2 Reflectance 2 Light to Solar Gain (LSG)7 U-Value4 EN 673 (W/m2 °C)Summer Day- time Winter Night- time Exterior Light % TotalSolarEnergy% Visible % Ultra- violet % (BTU/hr•ft2˚F) NFRC U-Value 3 Interior Light % Shading Coeffi- cient 5 Solar Heat Gain Coeffi - cient 6 Yin Yang House Location: Venice, California Product: Solarban® Solar Control Low-e Glass, DURANAR® Coatings Architect: Brooks+Scarpa GeneralContractotr: Lyons Construction Photo courtesy of John Linden The American Institute of Architects Committee on the Environment (COTE) named the Yin Yang House one of the Top 10 Green Buildings for 2013. 04/05/2021 303.296.9696 | dalyte.com | 290 E 56th Ave., Denver, CO 80216 DATE: November 5, 2019 Window v6.3.74.0 Report 08/08/19 12:51:39 ID: 11 Name: DᾹLYTE / A.I.A. Industries Curb Mount Skylight EnvCond: 1 NFRC 100-2010 Type: Skylight Tilt: 20 Width: 47.2 inches Height: 47.2 inches Area: 15.50 ft2 U-value: 0.476 Btu/h-ft2-F SHGC: 0.237 Vt: 0.410 CR: 14.7 Data for Glazing Systems COG ID Name Area #Lay Tilt Uc SCc SHGCc Vtc RHG ft2 Btu/h-ft2 ------ --------------- ----- ---- ---- ------- ----- ----- ----- ----- 14 1" SBr100 12.38 2 20 0.415 0.273 0.237 0.410 58 Layer Data for Glazing System '14 1" SBr100' ID Name D( ") Tsol 1 Rsol 2 Tvis 1 Rvis 2 Tir 1 Emis 2 Keff ------ --------------- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- Outside 5404 SBR100_Clear_6.#0.223 .219 .402 .501 .466 .302 .065 .000 .840 .036 .578 1 Air 0.500 .029 5013 CLEAR_8.PPG #0.312 .722 .069 .070 .875 .084 .084 .000 .840 .840 .578 Inside Frame Data Frame Edge Location ID Name Source Area Area Uframe Uedge ft2 ft2 Btu/h-ft2-F ---------------- ------ ------------- ------------- ----- ----- ------- ------ Header 23 Curb Mount He Therm 0.005 0.776 35.1990 0.4950 Left Jamb 24 Curb Mount Ja Therm 0.005 0.776 36.9430 0.4950 Right Jamb 24 Curb Mount Ja Therm 0.005 0.776 36.9430 0.4950 Sill 25 Curb Mount Si Therm 0.005 0.776 36.9430 0.4950 04/05/2021 Document the U-factors of the skylights in accordance with City policy: 3.Provide a simulation or test by an NFRC–accredited lab in accordance with NFRC-100 prior to permit approval. To document the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the simulation or test is required prior to field inspection. 303.296.9696 | dalyte.com | 290 E 56th Ave., Denver, CO 80216 DATE : November 5, 2019 QUOTE # : DALYTE CM NFRC PAGE : Page 2 of 2 Gas Data ID Name Type Cond Visc Cp Dens Pran x e-6 ______ ________________________ _____ ______ _______ _______ _______ ______ 1 Air Pure 0.0139 11.57 0.24 0.0807 0.7197 Window v6.3.74.0 Report Environmental Conditions: 1 NFRC 100-2010 Tout Tin WndSpd Wnd Dir Solar Tsky Esky (F) (F) (mph) (Btu/h-ft2) (F) ----- ---- ------ -------- ------ ---- ---- Uvalue -0.4 69.8 12.30 Windward 0.0 -0.4 1.00 Solar 89.6 75.2 6.26 Windward 248.2 89.6 1.00 Frame Library Data U-value Edge GlzSys GlzSys Width ID Name Source Frame Edge Corr Width Uc (PFD) Abs ______ _____________ ____________ ______ ______ ____ ______ ______ _____ ____ 23 Curb Mount He Therm 35.1990 0.4950 N/A 1.035 0.290 0.02 0.30 24 Curb Mount Ja Therm 36.9430 0.4930 N/A 1.035 0.290 0.02 0.30 25 Curb Mount Si Therm 36.9430 0.4930 N/A 1.035 0.290 0.02 0.30 Divider Library Data U-value Edge GlzSys GlzSys Width ID Name Source Div Edge Corr Width Uc (PFD) Abs _____ _____________ ____________ ______ ______ ____ ______ ______ _____ ____ No Dividers for this Glazing System 04/05/2021 303.296.9696 | dalyte.com | 290 E 56th Ave., Denver, CO 80216 DATE : November 5, 2019 QUOTE # : DALYTE CM NFRC PAGE : Page 3 of 2 Optical Properties for Glazing System '14 1" SBr100' Angle 0 10 20 30 40 50 60 70 80 90 Hemis Vtc : 0.410 0.412 0.407 0.399 0.388 0.368 0.321 0.233 0.108 0.000 0.342 Rf : 0.320 0.314 0.313 0.315 0.324 0.339 0.369 0.441 0.617 0.999 0.357 Rb : 0.135 0.129 0.128 0.132 0.145 0.173 0.234 0.373 0.634 1.000 0.212 Tsol : 0.183 0.184 0.181 0.178 0.173 0.163 0.142 0.103 0.047 0.000 0.152 Rf : 0.409 0.404 0.403 0.405 0.412 0.424 0.448 0.508 0.660 0.999 0.439 Rb : 0.289 0.285 0.281 0.279 0.279 0.287 0.314 0.391 0.571 1.000 0.313 Abs1 : 0.387 0.391 0.395 0.396 0.394 0.391 0.389 0.371 0.279 0.001 0.380 Abs2 : 0.020 0.021 0.021 0.021 0.021 0.021 0.021 0.018 0.013 0.000 0.020 SHGCc: 0.237 0.239 0.237 0.234 0.228 0.219 0.197 0.154 0.083 0.000 0.205 Tdw-K : 0.204 Tdw-ISO: 0.331 Tuv : 0.109 Window v6.3.74.0 Report Temper ature Distribution (degrees F) Winter Summer Out In Out In ---- ---- ---- ---- Lay1 5.3 6.2 112.3 113.4 Lay2 48.0 49.3 88.1 87.5 04/05/2021 Element Materials Technology P 515 266 5101 3922 Delaware Avenue F 515 262 1910 Des Moines, IA info.desmoines@element.com 50313-2542 USA element.com It is our policy to retain components and sample remnants for a minimum of 30 days from the report date, after which time they may be discarded. The data herein represents only the item(s) tested. This report shall not be reproduced, except in full, without prior permission of Element Materials Technology. EAR Controlled Data: This document contains technical data whose export and re-export/retransfer is subject to control by the U.S. Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce's prior written approval may be required for the export or re-export/retransfer of such technical data to any foreign person, foreign entity or foreign organization whether in the United States or abroad. This project shall be governed exclusively by the General Terms and Conditions of Sale and Performance of Testing Services by Element Materials Technology. In no event shall Element Materials Technology be liable for any consequential, special or indirect loss or any damages above the cost of the work. This certificate shall not be reproduced, except in full, without the written approval of the laboratory. Testing AIA Industries Report Date: December 3, 2014 Mr. Ed Bartlett Author: Richard B. Luna 290 East 56th Avenue Report Number: ESP018314P.4 Denver, CO 80216 PRODUCT NAME: Curb Mount Skylight PRODUCT TYPE: Glass Skylight SERIES/MODEL: Glass Skylight Standard/Specifications Summary ASTM E330-02 Positive 120.38 psf 04/05/2021 EAR-CONTROLLED DATA Report Number ESP018314P.4 December 3, 2014 Page 2 of 3 INTRODUCTION: The following report presents the results of tests conducted on a Glass Skylight with a 4-12 pitch manufactured by AIA Industries. Testing was conducted on December 2, 2014 by Richard Luna of Element Des Moines. The tests were requested by Mr. Ed Bartlett of AIA Industries and were performed at Element Des Moines. The purpose of the testing was to determine the performance of the skylight for, uniform load deflection test and uniform load structural test in accordance with ASTME330-02. SUMMARY OF RESULTS: See "TEST RESULTS" section for the allowed requirements of the test specimen. Test Measured Uniform Load Structural Test @ 5760 Pa (120.38psf) Positive for 60 seconds Complies Permanent deformation N/A TEST RESULTS: UNIFORM LOAD DEFLECTION TEST Parameter Units Measured Allowed Requirement Maximum Test Load - Positive Pa (PSF) 120.38 psf 120.38 psf Duration Seconds 60 60 Deflection Under Load No Unsupported Span mm (inches) N/A Report Only OVERALL PERFORMANCE ----- Complies No breakage or damage of acrylic or glazing TEST METHODS: Uniform Load Structural Test ASTM: E330-02, "Standard Test Method for Structural Performance of Exterior Windows, Skylights, Curtain Walls, and Doors by Uniform Static Air Pressure Difference". 04/05/2021 EAR-CONTROLLED DATA Report Number ESP018314P.4 December 3, 2014 Page 3 of 3 TEST UNIT DESCRIPTION: Product Name : Curb Mount Skylight Product Type : Glass Skylight Series/Model # : Glass Skylight Rating Tested To : Structural Tests: +DP60/ –DP30 Overall Frame Size : 1219 x 2438 mm (48.000 x 96.000 inches) Finish : Mill Frame Construction : T.B. Aluminum (P & D) Glazing System : 1 3/16” temp/laminate Weather Strip : ¼” x ½” glazing tape Joint Sealant Application : Dow Corning 791 General Installation Description : #8 TEK screws Installation Method : Direct attachment to wood buck REMARKS: The test results contained in this report pertain only to the fenestration sample submitted for testing and not necessarily to all similar products. Detailed assembly drawings showing wall thickness of all members, corner construction and hardware application are on file and have been compared to the sample submitted. A test sample will be retained at the test laboratory. A copy of this report has been forwarded to the Validator. The above results were secured by using the designated test methods and they do indicate compliance with the performance requirements of the referenced specifications. This report does not constitute certification of this product which may only be granted by the Validator. The detailed drawings and representative samples of the tested window will be held in the laboratory for a period of four (4) years. C:\Users\Rluna\Desktop\AIA Industries\ESP018314P\ESP018314P.4Final.Docx lam Respectfully submitted, Tested and Prepared By: Reviewed By: Richard B. Luna Project Manager P 515-309-4228 Brian S. Escherich Operations Manager, Des Moines Individual in Direct Charge P 515-309-4220 04/05/2021 Element Materials Technology P 515 266 5101 3922 Delaware Avenue F 515 262 1910 Des Moines, IA info.desmoines@element.com 50313-2542 USA element.com It is our policy to retain components and sample remnants for a minimum of 30 days from the report date, after which time they may be discarded. The data herein represents only the item(s) tested. This report shall not be reproduced, except in full, without prior permission of Element Materials Technology. EAR Controlled Data: This document contains technical data whose export and re-export/retransfer is subject to control by the U.S. Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce's prior written approval may be required for the export or re-export/retransfer of such technical data to any foreign person, foreign entity or foreign organization whether in the United States or abroad. This project shall be governed exclusively by the General Terms and Conditions of Sale and Performance of Testing Services by Element Materials Technology. In no event shall Element Materials Technology be liable for any consequential, special or indirect loss or any damages above the cost of the work. This certificate shall not be reproduced, except in full, without the written approval of the laboratory. Testing AIA Industries Report Date: December 3, 2014 Mr. Ed Bartlett Author: Richard B. Luna 290 East 56th Avenue Report Number: ESP018314P.3 Denver, CO 80216 PRODUCT NAME: Curb Mount Skylight PRODUCT TYPE: Glass Skylight SERIES/MODEL: Glass Skylight Standard/Specifications Summary ASTM E283-04 0.20 L/(sm2) (0.04cfm/ft²) ASTM E547-00 15 psf ASTM E331-00 15 psf ASTM E330-02 DP+60/DP-30 04/05/2021 EAR-CONTROLLED DATA Report Number ESP018314P.3 December 3, 2014 Page 2 of 6 INTRODUCTION: The following report presents the results of tests conducted on a Glass Skylight with a 4-12 pitch manufactured by AIA Industries. Testing was conducted on December 2, 2014 by Richard Luna of Element Des Moines. The tests were requested by Mr. Ed Bartlett of AIA Industries and were performed at Element Des Moines. The purpose of the testing was to determine the performance of the skylight for the air leakage resistance test in accordance with ASTM E283-04, water penetration resistance test in accordance with ASTM E547-00, uniform load deflection test and uniform load structural test in accordance with ASTME330-02. SUMMARY OF RESULTS: See "TEST RESULTS" section for the allowed requirements of the test specimen. Test Measured Air Leakage Resistance Test @ +75 Pa (1.57 psf) (Infiltration) 0.20 L/(sm2) (0.04 cfm/ft²) @ +300 Pa (6.24 psf) 0.56 L/(sm2) (0.11 cfm/ft²) Water Penetration Resistance Test @ 720 Pa (15.05 psf) No Entry: Complies Uniform Load Deflection Test @ 2880 Pa (60.15 psf) Positive/ 1440 Pa (30.08 psf) Negative Complies Deflection N/A Uniform Load Structural Test @ 4320 Pa (90.23 psf) Positive/ 2160 Pa (45.11 psf) Negative Complies Permanent deformation N/A 04/05/2021 EAR-CONTROLLED DATA Report Number ESP018314P.3 December 3, 2014 Page 3 of 6 TEST RESULTS: AIR LEAKAGE RESISTANCE TEST Parameter Units Measured Allowable Requirement Total Product Area m2 (ft²) 2.97 (32.00) ---- Total Sash Crack Length m (ft.) 6.91 (22.67) ---- Test Pressure Difference - Infiltration Pa (psf) +75 (1.57) +75 (1.57) Air Leakage L/s (cfm) 0.60 (1.27) ---- Air Leakage Rate L/(sm2) (cfm/ft²) 0.20 (0.04) 1.5 max (0.3 max) Test Pressure Difference - Infiltration Pa (psf) +300 (6.24) 300 (6.24) Air Leakage L/s (cfm) 1.68 (3.55) ---- Air Leakage Rate L/(sm2) (cfm/ft²) 0.56 (0.11) Reporting Only WATER PENETRATION RESISTANCE TEST Parameter Units Measured Allowed Requirement Test Pressure Difference Pa (psf) 720 (15.05) N/A Water Flow L/(m2min) (GPH/ft²) 3.4 (5) 3.4 (5) Duration Cyclic (5 min. on, 1 min. off) cycles 4 4 Duration Static (15 min.) Minutes 15 Report Only Water Penetration Resistance ---- Complies No Entry of water past water/test plane 04/05/2021 EAR-CONTROLLED DATA Report Number ESP018314P.3 December 3, 2014 Page 4 of 6 TEST RESULTS: UNIFORM LOAD DEFLECTION TEST Parameter Units Measured Allowed Requirement Maximum Test Load - Positive Pa (PSF) 2880 (60.15) N/A Duration Seconds 10 10 Deflection Under Load No Unsupported Span mm (inches) N/A Report Only Maximum Test Load - Negative Pa (PSF) 1440 (30.08) N/A Duration Seconds 10 10 Deflection Under Load No Unsupported Span mm (inches) N/A Report Only OVERALL PERFORMANCE ----- Complies No breakage or damage of acrylic or glazing UNIFORM LOAD STRUCTURAL TEST Parameter Units Measured Allowed Requirement Maximum Test Load - Positive Pa (PSF) 4320 (90.23) N/A Duration Seconds 10 10 Permanent deformation No Unsupported Span mm (inches) N/A Reporting Only Maximum Test Load - Negative Pa (PSF) 2160 (45.11) N/A Duration Seconds 10 10 Permanent Deformation No Unsupported Span mm (inches) N/A Reporting Only OVERALL PERFORMANCE ----- Complies No breakage or damage of acrylic or glazing 04/05/2021 EAR-CONTROLLED DATA Report Number ESP018314P.3 December 3, 2014 Page 5 of 6 TEST METHODS: Air Leakage Resistance Test ASTM: E283-04, "Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows,Skylights, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen". Water Penetration Resistance Test ASTM: E331-00, "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Static Air Pressure Difference." Water Penetration Resistance Test ASTM: E547-00, "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference." Uniform Load Deflection Test ASTM: E330-02, “Standard Test Method for Structural Performance of Exterior Windows, Skylights, Curtain Walls, and Doors by Uniform Static Air Pressure Difference”. Uniform Load Structural Test ASTM: E330-02, "Standard Test Method for Structural Performance of Exterior Windows, Skylights, Curtain Walls, and Doors by Uniform Static Air Pressure Difference". TEST UNIT DESCRIPTION: Product Name : Curb Mount Skylight Product Type : Glass Skylight Series/Model # : Glass Skylight Rating Tested To : Air Leakage: +75 Pa, +300 Pa Water Resistance: DP100 Structural Tests: +DP60/ –DP30 Overall Frame Size : 1219 x 2438 mm (48.000 x 96.000 inches) Sash Size : N/A Finish : Mill Frame Construction : T.B. Aluminum (P & D) Glazing System : 1 3/16” temp/laminate Weather Strip : ¼” x ½” glazing tape Joint Sealant Application : Dow Corning 791 General Installation Description : #8 TEK screws Installation Method : Direct attachment to wood buck 04/05/2021 EAR-CONTROLLED DATA Report Number ESP018314P.3 December 3, 2014 Page 6 of 6 REMARKS: The test results contained in this report pertain only to the fenestration sample submitted for testing and not necessarily to all similar products. Detailed assembly drawings showing wall thickness of all members, corner construction and hardware application are on file and have been compared to the sample submitted. A test sample will be retained at the test laboratory. A copy of this report has been forwarded to the Validator. The above results were secured by using the designated test methods and they do indicate compliance with the performance requirements of the referenced specifications. This report does not constitute certification of this product which may only be granted by the Validator. The detailed drawings and representative samples of the tested window will be held in the laboratory for a period of four (4) years. C:\Users\Rluna\Desktop\AIA Industries\ESP018314P\ESP018314P.3Final.Docx lam Respectfully submitted, Tested and Prepared By: Reviewed By: Richard B. Luna Project Manager P 515-309-4228 Brian S. Escherich Operations Manager, Des Moines Individual in Direct Charge P 515-309-4220 04/05/2021