FLAT GLASS/FLASHING MODEL #OUTSIDE CURB DIMENSIONS
2424 GLS 25-1/2” x 25-1/2”
2424 FLASHING 25-1/2” x 25-1/2”
2448 GLS 25-1/2” x 49-1/2”
2448 FLASHING 25-1/2” x 49-1/2”
4848 GLS 49-1/2” x 49-1/2”
4848 FLASHING 49-1/2” x 49-1/2”
SUMMIT SERIES™
CURB MOUNT FIXED SKYLIGHTS
2X4
2X2
DĀLYTE Skylights are Designed, Built and Storm
Tested in the Rocky Mountain Region Since 1977
DĀLYTE offers standard and custom sizes of Low-E Flat-Glass skylights. Our
skylights include thermally-broken aluminum frames for higher energy efficiency.
Professional Grade materials including welded heavy gauge aluminum frames
come standard. Our skylights are easy to install with built-in tolerances for out of
square curbs.
FEATURES
•Dark Bronze anodized exterior frame
•Includes Curb Mount Installation Kit with curb tape and screws
•Glazing:
–Low-E clear/clear with laminated inner layer for
safety and exterior protection film
OPTIONAL ADD-ONS
•Self-flashing/deck mount
•Flashing kits
•Clear anodized exterior frame
•Multi-wall polycarbonate: clear, bronze & white
04/05/2021
HOW TO MEASURE A CURB
DĀLYTE designs, constructs and installs architectural and structural skylights that
welcome the sky in, creating stunning spaces. A single source of responsibility means
your project is handled by our expert team from initial design through installation.
Design your sky with DĀLYTE.
Outside Curb Dimension
New Exposed Curb
OUT
S
I
D
E
C
U
R
B
D
I
M
E
N
S
I
O
N
OU
T
S
I
D
E
C
U
R
B
D
I
M
E
N
S
I
O
N
• Always measure the outside curb dimension...not the skylight frame
• DĀLYTE adds 5/8” standard clearance on ALL sides which is in addition to the outside curb dimensions
• If possible, outside curb dimensions should be taken on the exposed curb
• The 5/8” clearance is for the roofing materials, flashing and out-of-square curbs
04/05/2021
PLAN
ISOSINGLE SLOPE
CURB MOUNT SINGLE SLOPE
with FLAT GLASS
CURB MOUNT
with FLAT GLASSFax (303) 296-2146
D LYTE
An AiA Industries Company
290 East 56th Avenue
Denver, CO 80216 v (303) 296-9696
04/05/2021
HEAD
CURB MOUNT
SINGLE SLOPE
Fax (303) 296-2146
D LYTE
An AiA Industries Company
290 East 56th Avenue
Denver, CO 80216 v (303) 296-9696
04/05/2021
CURB MOUNT
SINGLE SLOPE
SILLFax (303) 296-2146
D LYTE
An AiA Industries Company
290 East 56th Avenue
Denver, CO 80216 v (303) 296-9696
04/05/2021
END RAFTER
CURB MOUNT
SINGLE SLOPE
Fax (303) 296-2146
D LYTE
An AiA Industries Company
290 East 56th Avenue
Denver, CO 80216 v (303) 296-9696
04/05/2021
04/05/2021
1-888-PPG-IDEA (1-888-774-4332) www.ppgideascapes.com 27
One-Inch Insulating Glass Unit Comparisons with PPG Glass
Coated
Insulating Glass Unit Performance Comparisons 1-inch (25mm) units with 1/2-inch (13mm) air fill and two 1/4-inch (6mm) lites; interior lite clear unless otherwise noted
SOLARBAN ® 70XL Solar Control Low-E Glass†
SOLARBAN 70XL (2) + Clear 6 64 25 12 13 0.28 0.26 1.5 0.32 0.27 2.37
SOLARBAN 70XL (2) SOLEXIA + Clear 4 58 21 10 13 0.28 0.26 1.5 0.31 0.27 2.15
SOLARBAN 70XL (2) ATLANTICA + Clear 2 51 17 9 12 0.28 0.26 1.5 0.28 0.24 2.13
SOLARBAN 70XL (2) AZURIA + Clear 5 52 18 9 12 0.28 0.26 1.5 0.29 0.25 2.08
SOLARBAN 70XL (2) PACIFICA + Clear 2 32 12 6 12 0.28 0.26 1.5 0.22 0.19 1.68
SOLARBAN 70XL (2) SOLARBLUE + Clear 4 42 17 8 12 0.28 0.26 1.5 0.26 0.23 1.83
SOLARBAN 70XL (2) SOLARBRONZE + Clear 3 40 15 7 12 0.28 0.26 1.5 0.25 0.21 1.90
SOLARBAN 70XL (2) OPTIGRAY + Clear 4 47 18 8 12 0.28 0.26 1.5 0.28 0.24 1.96
SOLARBAN 70XL (2) SOLARGRAY + Clear 3 34 13 6 12 0.28 0.26 1.5 0.23 0.20 1.70
SOLEXIA + SOLARBAN 70XL (3) 3 56 20 11 12 0.28 0.26 1.5 0.37 0.32 1.75
ATLANTICA + SOLARBAN 70XL (3) 2 49 17 10 11 0.28 0.26 1.5 0.32 0.28 1.75
AZURIA + SOLARBAN 70XL (3) 4 49 17 9 11 0.28 0.26 1.5 0.33 0.29 1.69
PACIFICA + SOLARBAN 70XL (3) 2 31 12 6 10 0.28 0.26 1.5 0.26 0.22 1.41
SOLARBLUE + SOLARBAN 70XL (3) 3 40 16 8 11 0.28 0.26 1.5 0.32 0.27 1.48
SOLARBRONZE + SOLARBAN 70XL (3) 3 38 15 8 11 0.28 0.26 1.5 0.30 0.26 1.46
OPTIGRAY + SOLARBAN 70XL (3) 3 45 17 9 11 0.28 0.26 1.5 0.33 0.29 1.55
SOLARGRAY + SOLARBAN 70XL (3) 2 32 13 7 11 0.28 0.26 1.5 0.27 0.24 1.33
GRAYLITE II + SOLARBAN 70XL (3) 0 6 3 4 10 0.28 0.26 1.5 0.13 0.11 0.55
SOLARBAN ® 72 Solar Control Low-E Glass
SOLARBAN 72 (2) STARPHIRE †† 9 71 28 13 13 0.29 0.27 1.5 0.34 0.30 2.37
SOLARBAN ® z50 Solar Control Low-E Glass†† †
SOLARBAN z50 (2) OPTIBLUE + Clear 14 51 25 8 11 0.29 0.27 1.6 0.36 0.32 1.59
SOLARBAN z50 (2) OPTIBLUE + OPTIBLUE 11 37 20 7 8 0.29 0.27 1.6 0.35 0.31 1.19
SOLARBAN ® z75 Solar Control Low-E Glass†† †
SOLARBAN z75 (2) OPTIBLUE + Clear 6 48 19 9 12 0.28 0.26 1.5 0.28 0.24 2.00
SOLARBAN ® R100 Solar Control Low-E Glass
SOLARBAN R100 (2) + Clear 12 42 19 32 14 0.29 0.27 1.6 0.27 0.23 1.83
SOLARBAN R100 (2) STARPHIRE + STARPHIRE 16 44 21 33 14 0.29 0.27 1.6 0.27 0.23 1.91
SOLARBAN R100 (2) SOLEXIA + Clear 6 36 15 25 13 0.29 0.27 1.6 0.24 0.21 1.71
SOLARBAN R100 (2) ATLANTICA + Clear 3 32 12 20 13 0.29 0.27 1.6 0.22 0.19 1.68
SOLARBAN R100 (2) AZURIA + Clear 8 32 12 21 13 0.29 0.27 1.6 0.22 0.19 1.68
SOLARBAN R100 (2) OPTIBLUE + Clear 8 30 14 19 13 0.29 0.27 1.6 0.23 0.20 1.50
SOLARBAN R100 (2) PACIFICA + Clear 3 20 9 11 13 0.29 0.27 1.6 0.19 0.16 1.25
SOLARBAN R100 (2) SOLARBLUE + Clear 6 26 12 15 13 0.29 0.27 1.6 0.22 0.19 1.37
SOLARBAN R100 (2) SOLARBRONZE + Clear 5 25 11 15 13 0.29 0.27 1.6 0.21 0.18 1.39
SOLARBAN R100 (2) OPTIGRAY + Clear 6 29 13 18 13 0.29 0.27 1.6 0.22 0.20 1.45
SOLARBAN R100 (2) SOLARGRAY + Clear 5 21 10 12 13 0.29 0.27 1.6 0.19 0.17 1.24
Glass Type
+Outdoor Lite:
Coating if Any (Surface) Glass
Indoor Lite:
Coating if Any (Surface) Glass
Transmittance 2 Reflectance 2 Light to
Solar
Gain
(LSG)7
U-Value4
EN 673
(W/m2 °C)Summer
Day-
time
Winter
Night-
time
Exterior
Light
%
TotalSolarEnergy%
Visible
%
Ultra-
violet
%
(BTU/hr•ft2˚F) NFRC U-Value 3
Interior
Light
%
Shading
Coeffi-
cient 5
Solar
Heat
Gain
Coeffi -
cient 6
Yin Yang House
Location: Venice, California
Product: Solarban® Solar Control Low-e Glass, DURANAR® Coatings
Architect: Brooks+Scarpa
GeneralContractotr: Lyons Construction
Photo courtesy of John Linden
The American Institute of Architects Committee on
the Environment (COTE) named the Yin Yang House
one of the Top 10 Green Buildings for 2013.
04/05/2021
303.296.9696 | dalyte.com | 290 E 56th Ave., Denver, CO 80216
DATE: November 5, 2019
Window v6.3.74.0 Report 08/08/19 12:51:39
ID: 11
Name: DᾹLYTE / A.I.A. Industries
Curb Mount Skylight
EnvCond: 1 NFRC 100-2010
Type: Skylight
Tilt: 20
Width: 47.2 inches
Height: 47.2 inches
Area: 15.50 ft2
U-value: 0.476 Btu/h-ft2-F
SHGC: 0.237
Vt: 0.410
CR: 14.7
Data for Glazing Systems
COG
ID Name Area #Lay Tilt Uc SCc SHGCc Vtc RHG
ft2 Btu/h-ft2
------ --------------- ----- ---- ---- ------- ----- ----- ----- -----
14 1" SBr100 12.38 2 20 0.415 0.273 0.237 0.410 58
Layer Data for Glazing System '14 1" SBr100'
ID Name D( ") Tsol 1 Rsol 2 Tvis 1 Rvis 2 Tir 1 Emis 2 Keff
------ --------------- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
Outside
5404 SBR100_Clear_6.#0.223 .219 .402 .501 .466 .302 .065 .000 .840 .036 .578
1 Air 0.500 .029
5013 CLEAR_8.PPG #0.312 .722 .069 .070 .875 .084 .084 .000 .840 .840 .578
Inside
Frame Data
Frame Edge
Location ID Name Source Area Area Uframe Uedge
ft2 ft2 Btu/h-ft2-F
---------------- ------ ------------- ------------- ----- ----- ------- ------
Header 23 Curb Mount He Therm 0.005 0.776 35.1990 0.4950
Left Jamb 24 Curb Mount Ja Therm 0.005 0.776 36.9430 0.4950
Right Jamb 24 Curb Mount Ja Therm 0.005 0.776 36.9430 0.4950
Sill 25 Curb Mount Si Therm 0.005 0.776 36.9430 0.4950
04/05/2021
Document the U-factors of the skylights in accordance with City policy:
3.Provide a simulation or test by an NFRC–accredited lab in accordance with NFRC-100 prior to permit approval. To document
the chain of custody, an affidavit or other evidence from the manufacturer confirming compliance with the simulation or test is
required prior to field inspection.
303.296.9696 | dalyte.com | 290 E 56th Ave., Denver, CO 80216
DATE : November 5, 2019
QUOTE # : DALYTE CM NFRC
PAGE : Page 2 of 2
Gas Data
ID Name Type Cond Visc Cp Dens Pran
x e-6
______ ________________________ _____ ______ _______ _______ _______ ______
1 Air Pure 0.0139 11.57 0.24 0.0807 0.7197
Window v6.3.74.0 Report
Environmental Conditions: 1 NFRC 100-2010
Tout Tin WndSpd Wnd Dir Solar Tsky Esky
(F) (F) (mph) (Btu/h-ft2) (F)
----- ---- ------ -------- ------ ---- ----
Uvalue -0.4 69.8 12.30 Windward 0.0 -0.4 1.00
Solar 89.6 75.2 6.26 Windward 248.2 89.6 1.00
Frame Library Data
U-value Edge GlzSys GlzSys Width
ID Name Source Frame Edge Corr Width Uc (PFD) Abs
______ _____________ ____________ ______ ______ ____ ______ ______ _____ ____
23 Curb Mount He Therm 35.1990 0.4950 N/A 1.035 0.290 0.02 0.30
24 Curb Mount Ja Therm 36.9430 0.4930 N/A 1.035 0.290 0.02 0.30
25 Curb Mount Si Therm 36.9430 0.4930 N/A 1.035 0.290 0.02 0.30
Divider Library Data
U-value Edge GlzSys GlzSys Width
ID Name Source Div Edge Corr Width Uc (PFD) Abs
_____ _____________ ____________ ______ ______ ____ ______ ______ _____ ____
No Dividers for this Glazing System
04/05/2021
303.296.9696 | dalyte.com | 290 E 56th Ave., Denver, CO 80216
DATE : November 5, 2019
QUOTE # : DALYTE CM NFRC
PAGE : Page 3 of 2
Optical Properties for Glazing System '14 1" SBr100'
Angle 0 10 20 30 40 50 60 70 80 90 Hemis
Vtc : 0.410 0.412 0.407 0.399 0.388 0.368 0.321 0.233 0.108 0.000 0.342
Rf : 0.320 0.314 0.313 0.315 0.324 0.339 0.369 0.441 0.617 0.999 0.357
Rb : 0.135 0.129 0.128 0.132 0.145 0.173 0.234 0.373 0.634 1.000 0.212
Tsol : 0.183 0.184 0.181 0.178 0.173 0.163 0.142 0.103 0.047 0.000 0.152
Rf : 0.409 0.404 0.403 0.405 0.412 0.424 0.448 0.508 0.660 0.999 0.439
Rb : 0.289 0.285 0.281 0.279 0.279 0.287 0.314 0.391 0.571 1.000 0.313
Abs1 : 0.387 0.391 0.395 0.396 0.394 0.391 0.389 0.371 0.279 0.001 0.380
Abs2 : 0.020 0.021 0.021 0.021 0.021 0.021 0.021 0.018 0.013 0.000 0.020
SHGCc: 0.237 0.239 0.237 0.234 0.228 0.219 0.197 0.154 0.083 0.000 0.205
Tdw-K : 0.204
Tdw-ISO: 0.331
Tuv : 0.109
Window v6.3.74.0 Report
Temper ature Distribution (degrees F)
Winter Summer
Out In Out In
---- ---- ---- ----
Lay1 5.3 6.2 112.3 113.4
Lay2 48.0 49.3 88.1 87.5
04/05/2021
Element Materials Technology P 515 266 5101
3922 Delaware Avenue F 515 262 1910
Des Moines, IA info.desmoines@element.com
50313-2542 USA element.com
It is our policy to retain components and sample remnants for a minimum of 30 days from the report date, after which time they may be
discarded. The data herein represents only the item(s) tested. This report shall not be reproduced, except in full, without prior permission of
Element Materials Technology.
EAR Controlled Data: This document contains technical data whose export and re-export/retransfer is subject to control by the U.S.
Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce's
prior written approval may be required for the export or re-export/retransfer of such technical data to any foreign person, foreign entity or
foreign organization whether in the United States or abroad.
This project shall be governed exclusively by the General Terms and Conditions of Sale and Performance of Testing Services by Element
Materials Technology. In no event shall Element Materials Technology be liable for any consequential, special or indirect loss or any damages
above the cost of the work.
This certificate shall not be reproduced, except in full, without the written approval of the laboratory.
Testing
AIA Industries Report Date: December 3, 2014
Mr. Ed Bartlett Author: Richard B. Luna
290 East 56th Avenue Report Number: ESP018314P.4
Denver, CO 80216
PRODUCT NAME: Curb Mount Skylight
PRODUCT TYPE: Glass Skylight
SERIES/MODEL: Glass Skylight
Standard/Specifications Summary
ASTM E330-02 Positive 120.38 psf
04/05/2021
EAR-CONTROLLED DATA
Report Number ESP018314P.4 December 3, 2014 Page 2 of 3
INTRODUCTION:
The following report presents the results of tests conducted on a Glass Skylight with a 4-12 pitch
manufactured by AIA Industries. Testing was conducted on December 2, 2014 by Richard Luna of Element
Des Moines. The tests were requested by Mr. Ed Bartlett of AIA Industries and were performed at Element
Des Moines.
The purpose of the testing was to determine the performance of the skylight for, uniform load deflection test
and uniform load structural test in accordance with ASTME330-02.
SUMMARY OF RESULTS:
See "TEST RESULTS" section for the allowed requirements of the test specimen.
Test Measured
Uniform Load Structural Test
@ 5760 Pa (120.38psf) Positive for 60 seconds Complies
Permanent deformation N/A
TEST RESULTS:
UNIFORM LOAD DEFLECTION TEST
Parameter Units Measured Allowed
Requirement
Maximum Test Load - Positive Pa (PSF) 120.38 psf 120.38 psf
Duration Seconds 60 60
Deflection Under Load
No Unsupported Span
mm
(inches) N/A Report Only
OVERALL PERFORMANCE ----- Complies
No breakage or
damage of acrylic
or glazing
TEST METHODS:
Uniform Load Structural Test
ASTM: E330-02, "Standard Test Method for Structural Performance of Exterior Windows, Skylights, Curtain
Walls, and Doors by Uniform Static Air Pressure Difference".
04/05/2021
EAR-CONTROLLED DATA
Report Number ESP018314P.4 December 3, 2014 Page 3 of 3
TEST UNIT DESCRIPTION:
Product Name : Curb Mount Skylight
Product Type : Glass Skylight
Series/Model # : Glass Skylight
Rating Tested To : Structural Tests: +DP60/ –DP30
Overall Frame Size : 1219 x 2438 mm (48.000 x 96.000 inches)
Finish : Mill
Frame Construction : T.B. Aluminum (P & D)
Glazing System : 1 3/16” temp/laminate
Weather Strip : ¼” x ½” glazing tape
Joint Sealant Application : Dow Corning 791
General Installation
Description
: #8 TEK screws
Installation Method : Direct attachment to wood buck
REMARKS:
The test results contained in this report pertain only to the fenestration sample submitted for testing and
not necessarily to all similar products.
Detailed assembly drawings showing wall thickness of all members, corner construction and hardware
application are on file and have been compared to the sample submitted. A test sample will be retained
at the test laboratory. A copy of this report has been forwarded to the Validator.
The above results were secured by using the designated test methods and they do indicate compliance
with the performance requirements of the referenced specifications. This report does not constitute
certification of this product which may only be granted by the Validator.
The detailed drawings and representative samples of the tested window will be held in the laboratory for a
period of four (4) years.
C:\Users\Rluna\Desktop\AIA Industries\ESP018314P\ESP018314P.4Final.Docx lam
Respectfully submitted,
Tested and Prepared By: Reviewed By:
Richard B. Luna
Project Manager
P 515-309-4228
Brian S. Escherich
Operations Manager, Des Moines
Individual in Direct Charge
P 515-309-4220
04/05/2021
Element Materials Technology P 515 266 5101
3922 Delaware Avenue F 515 262 1910
Des Moines, IA info.desmoines@element.com
50313-2542 USA element.com
It is our policy to retain components and sample remnants for a minimum of 30 days from the report date, after which time they may be
discarded. The data herein represents only the item(s) tested. This report shall not be reproduced, except in full, without prior permission of
Element Materials Technology.
EAR Controlled Data: This document contains technical data whose export and re-export/retransfer is subject to control by the U.S.
Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce's
prior written approval may be required for the export or re-export/retransfer of such technical data to any foreign person, foreign entity or
foreign organization whether in the United States or abroad.
This project shall be governed exclusively by the General Terms and Conditions of Sale and Performance of Testing Services by Element
Materials Technology. In no event shall Element Materials Technology be liable for any consequential, special or indirect loss or any damages
above the cost of the work.
This certificate shall not be reproduced, except in full, without the written approval of the laboratory.
Testing
AIA Industries Report Date: December 3, 2014
Mr. Ed Bartlett Author: Richard B. Luna
290 East 56th Avenue Report Number: ESP018314P.3
Denver, CO 80216
PRODUCT NAME: Curb Mount Skylight
PRODUCT TYPE: Glass Skylight
SERIES/MODEL: Glass Skylight
Standard/Specifications Summary
ASTM E283-04 0.20 L/(sm2) (0.04cfm/ft²)
ASTM E547-00 15 psf
ASTM E331-00 15 psf
ASTM E330-02 DP+60/DP-30
04/05/2021
EAR-CONTROLLED DATA
Report Number ESP018314P.3 December 3, 2014 Page 2 of 6
INTRODUCTION:
The following report presents the results of tests conducted on a Glass Skylight with a 4-12 pitch
manufactured by AIA Industries. Testing was conducted on December 2, 2014 by Richard Luna of Element
Des Moines. The tests were requested by Mr. Ed Bartlett of AIA Industries and were performed at Element
Des Moines.
The purpose of the testing was to determine the performance of the skylight for the air leakage resistance test
in accordance with ASTM E283-04, water penetration resistance test in accordance with ASTM E547-00,
uniform load deflection test and uniform load structural test in accordance with ASTME330-02.
SUMMARY OF RESULTS:
See "TEST RESULTS" section for the allowed requirements of the test specimen.
Test Measured
Air Leakage Resistance Test
@ +75 Pa (1.57 psf) (Infiltration) 0.20 L/(sm2) (0.04 cfm/ft²)
@ +300 Pa (6.24 psf) 0.56 L/(sm2) (0.11 cfm/ft²)
Water Penetration Resistance Test
@ 720 Pa (15.05 psf) No Entry: Complies
Uniform Load Deflection Test
@ 2880 Pa (60.15 psf) Positive/ 1440 Pa (30.08 psf) Negative Complies
Deflection N/A
Uniform Load Structural Test
@ 4320 Pa (90.23 psf) Positive/ 2160 Pa (45.11 psf) Negative Complies
Permanent deformation N/A
04/05/2021
EAR-CONTROLLED DATA
Report Number ESP018314P.3 December 3, 2014 Page 3 of 6
TEST RESULTS:
AIR LEAKAGE RESISTANCE TEST
Parameter Units Measured Allowable
Requirement
Total Product Area m2 (ft²) 2.97 (32.00) ----
Total Sash Crack Length m (ft.) 6.91 (22.67) ----
Test Pressure Difference - Infiltration Pa (psf) +75 (1.57) +75 (1.57)
Air Leakage L/s (cfm) 0.60 (1.27) ----
Air Leakage Rate L/(sm2) (cfm/ft²) 0.20 (0.04) 1.5 max (0.3 max)
Test Pressure Difference - Infiltration Pa (psf) +300 (6.24) 300 (6.24)
Air Leakage L/s (cfm) 1.68 (3.55) ----
Air Leakage Rate L/(sm2) (cfm/ft²) 0.56 (0.11) Reporting Only
WATER PENETRATION RESISTANCE TEST
Parameter Units Measured Allowed Requirement
Test Pressure Difference Pa (psf) 720 (15.05) N/A
Water Flow L/(m2min)
(GPH/ft²) 3.4 (5) 3.4 (5)
Duration Cyclic (5 min. on, 1 min. off) cycles 4 4
Duration Static (15 min.) Minutes 15 Report Only
Water Penetration Resistance ---- Complies No Entry of water past
water/test plane
04/05/2021
EAR-CONTROLLED DATA
Report Number ESP018314P.3 December 3, 2014 Page 4 of 6
TEST RESULTS:
UNIFORM LOAD DEFLECTION TEST
Parameter Units Measured Allowed
Requirement
Maximum Test Load - Positive Pa (PSF) 2880 (60.15) N/A
Duration Seconds 10 10
Deflection Under Load
No Unsupported Span
mm
(inches) N/A Report Only
Maximum Test Load - Negative Pa (PSF) 1440 (30.08) N/A
Duration Seconds 10 10
Deflection Under Load
No Unsupported Span
mm
(inches) N/A Report Only
OVERALL PERFORMANCE ----- Complies
No breakage or
damage of acrylic
or glazing
UNIFORM LOAD STRUCTURAL TEST
Parameter Units Measured Allowed
Requirement
Maximum Test Load - Positive Pa (PSF) 4320 (90.23) N/A
Duration Seconds 10 10
Permanent deformation
No Unsupported Span
mm
(inches) N/A Reporting Only
Maximum Test Load - Negative Pa (PSF) 2160 (45.11) N/A
Duration Seconds 10 10
Permanent Deformation
No Unsupported Span
mm
(inches) N/A Reporting Only
OVERALL PERFORMANCE ----- Complies
No breakage or
damage of acrylic
or glazing
04/05/2021
EAR-CONTROLLED DATA
Report Number ESP018314P.3 December 3, 2014 Page 5 of 6
TEST METHODS:
Air Leakage Resistance Test
ASTM: E283-04, "Standard Test Method for Determining the Rate of Air Leakage Through Exterior
Windows,Skylights, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen".
Water Penetration Resistance Test
ASTM: E331-00, "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and
Curtain Walls by Static Air Pressure Difference."
Water Penetration Resistance Test
ASTM: E547-00, "Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and
Curtain Walls by Cyclic Static Air Pressure Difference."
Uniform Load Deflection Test
ASTM: E330-02, “Standard Test Method for Structural Performance of Exterior Windows, Skylights, Curtain
Walls, and Doors by Uniform Static Air Pressure Difference”.
Uniform Load Structural Test
ASTM: E330-02, "Standard Test Method for Structural Performance of Exterior Windows, Skylights, Curtain
Walls, and Doors by Uniform Static Air Pressure Difference".
TEST UNIT DESCRIPTION:
Product Name : Curb Mount Skylight
Product Type : Glass Skylight
Series/Model # : Glass Skylight
Rating Tested To : Air Leakage: +75 Pa, +300 Pa
Water Resistance: DP100
Structural Tests: +DP60/ –DP30
Overall Frame Size : 1219 x 2438 mm (48.000 x 96.000 inches)
Sash Size : N/A
Finish : Mill
Frame Construction : T.B. Aluminum (P & D)
Glazing System : 1 3/16” temp/laminate
Weather Strip : ¼” x ½” glazing tape
Joint Sealant Application : Dow Corning 791
General Installation
Description
: #8 TEK screws
Installation Method : Direct attachment to wood buck
04/05/2021
EAR-CONTROLLED DATA
Report Number ESP018314P.3 December 3, 2014 Page 6 of 6
REMARKS:
The test results contained in this report pertain only to the fenestration sample submitted for testing and
not necessarily to all similar products.
Detailed assembly drawings showing wall thickness of all members, corner construction and hardware
application are on file and have been compared to the sample submitted. A test sample will be retained
at the test laboratory. A copy of this report has been forwarded to the Validator.
The above results were secured by using the designated test methods and they do indicate compliance
with the performance requirements of the referenced specifications. This report does not constitute
certification of this product which may only be granted by the Validator.
The detailed drawings and representative samples of the tested window will be held in the laboratory for a
period of four (4) years.
C:\Users\Rluna\Desktop\AIA Industries\ESP018314P\ESP018314P.3Final.Docx lam
Respectfully submitted,
Tested and Prepared By: Reviewed By:
Richard B. Luna
Project Manager
P 515-309-4228
Brian S. Escherich
Operations Manager, Des Moines
Individual in Direct Charge
P 515-309-4220