HomeMy WebLinkAboutFile Documents.210 W Main St.0056.2019 (12).ARBKScale: AS NOTED
ISSUE
SCHEMATIC DESIGN
PERMIT SUBMITTAL
COMMENTS 1
COMMENTS 2
HPC APPROVAL
WINDOW HPC APPROVAL
CHANGE ORDER 1
KING LOUISE HOUSING
210 WEST MAIN STREET
ASPEN, CO 81611
1" ACTUAL
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL
HAVE BEEN ENLARGED OR
REDUCED, AFFECTING ALL
LABELED SCALES.
ALL DESIGNS, IDEAS ARRANGEMENTS
A N D P L A N S I N D I C AT E D BY T H E S E
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
R AY M O N D A R C HIT E C T S, IN C . A N D
SHALL NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
W I T H O U T W R I T T E N P E R M I S S I O N .
W R I T T EN D I M E NS I ON S S HA L L TAK E
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
A .6.14
9/18/20
DETAILS
DATE
11/22/18
KIM RAYMOND ARCHITECTS, INC.
| 300 E. HYMAN AVENUE, SUITE 100 |
| www.kimraymondarchitects.com |
| 970-925-2252 |
03/05/19
07/01/19
09/16/19
04/21/20
05/20/20
08/28/20
8"(DUCT)
1"8"(DUCT)
1"1"
5/8"
1 1/2"
1"
5/8"
5/8"
1 HR. FIRE RATED
SHAFT WALLASSEMBLY
FIRESTOP SYSTEM:
- 1" USG SHAFT LINER (ATTACHED
TO METAL STUDS.)
- 1" RIGID INSULATION
- 1 LAYER OF TYPE "X" 5/8" GYPSUM
1 HR. FIRE RATED
SHAFT WALL ASSEMBLY
@ ROOF JOISTS
FIRESTOP SYSTEM @ ROOF JOISTS:
- 2 LAYERS OF TYPE "X" 5/8" GYPSUM
AROUND BOILER VENT @ ROOF
JOISTS. TO TERMINATE UNDER PLYWOOD
AND OVER SHAFT WALL BELOW
TYPICAL DETAIL
DETAIL @ ROOF JOISTS
1 HR FLOOR
ASSEMBLY: FC 5115
1 HR FLOOR
ASSEMBLY: FC 5115
SEALANT AROUND
DUCT AT PENETRATION.
8" DUCT
1 HR SHAFT WALL ASSEMBLY:
- 1" USG SHAFT LINER (ATTACHED TO
METAL STUDS.)
- 1" RIGID INSULATION
- 1 LAYER OF 5/8" TYPE "X" GYPSUM
1 HR SHAFT WALL ASSEMBLY:
- 1" USG SHAFT LINER (ATTACHED TO
METAL STUDS.)
- 1" RIGID INSULATION
- 1 LAYER OF TYPE "X" 5/8" GYPSUM
- TYPE "X" 5/8" GYPSUM
- 2 LAYERS OF TYPE "X" 5/8" GYPSUM AROUND
BOILER VENT @ ROOF JOISTS. TO TERMINATE
UNDER PLYWOOD AND OVER SHAFT WALL
BELOW
24
24
2
6
2
6
2
6
2
8
PERFORMANCE SELECTOR
All details, specifi cations and data contained in this literature are intended as a general guide. These products must
not be used in a design or construction of any given structure without complete and detailed evaluation by a qualifi ed
structural engineer or architect to verify suitability of a particular product for use in the structure.
Non-loadbearing Acoustical Performance Reference
Construction Detail Description Test Number STC Test Number ARL Index
ONE-HOUR FIRE-RATED
CONSTRUCTION
wt. 8
31⁄8"
• 5/8" USG Sheetrock® Brand Firecode® X
Panels, joints fi nished
• 2-1/2" USG C-H studs 25 gauge 24" o.c.
• 1" USG Sheetrock® Brand Gypsum Liner Panels
UL Design
U415,
System A
or U469
39 USG-040901
Based on 4" C-H studs 25
gauge
SA926 1
TWO-HOUR FIRE-RATED
CONSTRUCTION
wt. 9
31⁄2"
• 1/2" USG Sheetrock® Brand Firecode® C Panels,
face layer joints fi nished
• 2-1/2" USG C-H studs 25 gauge 24" o.c.
• 1" USG Sheetrock® Brand Gypsum Liner Panels
UL Design
U415,
System B
or U438
38 USG-040917 SA926 2
43 USG-040917
Based on 4" C-H studs 25
gauge
48 RAL-OT-04-022
Based on 1" sound batts
in cavity
50 RAL-OT-04-019
Based on 4" C-H studs
25 gauge with 3" mineral
fi ber insulation
wt. 8
43⁄4"
• 3/4" USG Sheetrock® Brand Ultracode® Core
Panels, joints fi nished
• 4" USG C-H studs 25 gauge 24" o.c.
• 3" Thermafi ber® SAFB
• 1" USG Sheetrock® Brand Gypsum Liner Panels
UL Design
U415,
System C
51 RAL-OT-04-020
Based on 4" C-H studs
with 3" Thermafi ber®
SAFB insulation
SA926 3
wt. 10
35⁄8"
• 1/2" USG Durock® Brand Cement Board
• 5/8" USG Sheetrock® Brand Firecode® X Panels
• 2-1/2" USG C-H studs 20 gauge 24" o.c.
• 1-1/2" Thermafi ber® SAFB
• 1" USG Sheetrock® Brand Gypsum Liner Panels
• USG Durock® Brand Cement Board, screw
attached and laminated to gypsum panel with
four vertical strip ceramic tile mastic centered
between studs
UL Design
U415,
System D
SA926 4
wt. 9
31⁄2"
• 1/2" USG Sheetrock® Brand Firecode C® Panels
• 2-1/2" USG C-H studs 25 gauge 24" o.c.
• 1" USG Sheetrock® Brand Gypsum Liner Panels
• Joints fi nished both sides
UL Design
U415,
System E
or U467
44 USG-040911
Based on 4" C-H studs 25
gauge
SA926 5
wt. 10
4"
• 1/2" USG Sheetrock® Brand Firecode® C Panels
applied vertically, face layer joints fi nished
• RC-1 resilient channel or equivalent 24" o.c.
• 2-1/2" USG C-H studs 25 gauge 24" o.c.
• 1" USG Sheetrock® Brand Gypsum Liner Panels
UL Design
U415,
System F
53 USG-040909
Based on 4" C-H studs 25
gauge with
3" mineral fi ber insulation
SA926 6
58 USG-040910
Based on 4" C-H studs 25
gauge with
additional layer on liner
panel side and
3" mineral fi ber insulation
wt. 8
2"
2"
• 1" x 2" perimeter angles 25 gauge
• 1" USG Sheetrock® Brand Gypsum Liner Panels,
fastened to angles
• 1/2" USG Sheetrock® Brand Firecode C® Panels,
joints fi nished
UL Design
U529
SA926 7
USG Shaft Wall Systems | 15
SCALE: 1" = 1'-0"1 MECHANICAL CHASE ASSEMBLY-PLAN
SCALE: 1" = 1'-0"2 MECHANICAL CHASE ASSEMBLY-SECTION
3 USG SHAFT WALL SYSTEM
09/18/2020
Shaft wall not required at exterior walls:
713.6 Exterior walls. Where exterior
walls serve as a part of
a required shaft enclosure, such walls
shall comply with the
requirements of Section 705 for exterior
walls and the fireresistance-
rated enclosure requirements shall not
apply.
1 HR FLOOR
ASSEMBLY: FC 5115
SEALANT AROUND
DUCT AT PENETRATION.
1 HR SHAFT WALL ASSEMBLY:
- 1" USG SHAFT LINER (ATTACHED TO
METAL STUDS.)
- 1" RIGID INSULATION
- 1 LAYER OF TYPE "X" 5/8" GYPSUM
Shaft wall required
here
Listed horizontal 1
hour shaft assembly
with penetration
protection.
Enclose the bottom of
the shaft at basement
ceiling and it only
connects 3 stories and
therefore only needs
1 hour fire rating.If there is a horizontal
portion of flues, they
must also be in the
shaft enclosure. Detail
it and provide listed 1
hr horizontal shaft
assembly. It should
look something like
this:
trock® Brand
ed both side
eetrock® Bra
BLY-SECTION
53 USG-040909
Based on 4" C-H studs 25
SA926 653USG-040909
Based on 4" C-H studs 25
SA926 6
Listed horizontal
assembly
Use your vertical
assembly