Loading...
HomeMy WebLinkAboutFile Documents.210 W Main St.0056.2019 (12).ARBKScale: AS NOTED ISSUE SCHEMATIC DESIGN PERMIT SUBMITTAL COMMENTS 1 COMMENTS 2 HPC APPROVAL WINDOW HPC APPROVAL CHANGE ORDER 1 KING LOUISE HOUSING 210 WEST MAIN STREET ASPEN, CO 81611 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS A N D P L A N S I N D I C AT E D BY T H E S E DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM R AY M O N D A R C HIT E C T S, IN C . A N D SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER W I T H O U T W R I T T E N P E R M I S S I O N . W R I T T EN D I M E NS I ON S S HA L L TAK E P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A .6.14 9/18/20 DETAILS DATE 11/22/18 KIM RAYMOND ARCHITECTS, INC. | 300 E. HYMAN AVENUE, SUITE 100 | | www.kimraymondarchitects.com | | 970-925-2252 | 03/05/19 07/01/19 09/16/19 04/21/20 05/20/20 08/28/20 8"(DUCT) 1"8"(DUCT) 1"1" 5/8" 1 1/2" 1" 5/8" 5/8" 1 HR. FIRE RATED SHAFT WALLASSEMBLY FIRESTOP SYSTEM: - 1" USG SHAFT LINER (ATTACHED TO METAL STUDS.) - 1" RIGID INSULATION - 1 LAYER OF TYPE "X" 5/8" GYPSUM 1 HR. FIRE RATED SHAFT WALL ASSEMBLY @ ROOF JOISTS FIRESTOP SYSTEM @ ROOF JOISTS: - 2 LAYERS OF TYPE "X" 5/8" GYPSUM AROUND BOILER VENT @ ROOF JOISTS. TO TERMINATE UNDER PLYWOOD AND OVER SHAFT WALL BELOW TYPICAL DETAIL DETAIL @ ROOF JOISTS 1 HR FLOOR ASSEMBLY: FC 5115 1 HR FLOOR ASSEMBLY: FC 5115 SEALANT AROUND DUCT AT PENETRATION. 8" DUCT 1 HR SHAFT WALL ASSEMBLY: - 1" USG SHAFT LINER (ATTACHED TO METAL STUDS.) - 1" RIGID INSULATION - 1 LAYER OF 5/8" TYPE "X" GYPSUM 1 HR SHAFT WALL ASSEMBLY: - 1" USG SHAFT LINER (ATTACHED TO METAL STUDS.) - 1" RIGID INSULATION - 1 LAYER OF TYPE "X" 5/8" GYPSUM - TYPE "X" 5/8" GYPSUM - 2 LAYERS OF TYPE "X" 5/8" GYPSUM AROUND BOILER VENT @ ROOF JOISTS. TO TERMINATE UNDER PLYWOOD AND OVER SHAFT WALL BELOW 24 24 2 6 2 6 2 6 2 8 PERFORMANCE SELECTOR All details, specifi cations and data contained in this literature are intended as a general guide. These products must not be used in a design or construction of any given structure without complete and detailed evaluation by a qualifi ed structural engineer or architect to verify suitability of a particular product for use in the structure. Non-loadbearing Acoustical Performance Reference Construction Detail Description Test Number STC Test Number ARL Index ONE-HOUR FIRE-RATED CONSTRUCTION wt. 8 31⁄8" • 5/8" USG Sheetrock® Brand Firecode® X Panels, joints fi nished • 2-1/2" USG C-H studs 25 gauge 24" o.c. • 1" USG Sheetrock® Brand Gypsum Liner Panels UL Design U415, System A or U469 39 USG-040901 Based on 4" C-H studs 25 gauge SA926 1 TWO-HOUR FIRE-RATED CONSTRUCTION wt. 9 31⁄2" • 1/2" USG Sheetrock® Brand Firecode® C Panels, face layer joints fi nished • 2-1/2" USG C-H studs 25 gauge 24" o.c. • 1" USG Sheetrock® Brand Gypsum Liner Panels UL Design U415, System B or U438 38 USG-040917 SA926 2 43 USG-040917 Based on 4" C-H studs 25 gauge 48 RAL-OT-04-022 Based on 1" sound batts in cavity 50 RAL-OT-04-019 Based on 4" C-H studs 25 gauge with 3" mineral fi ber insulation wt. 8 43⁄4" • 3/4" USG Sheetrock® Brand Ultracode® Core Panels, joints fi nished • 4" USG C-H studs 25 gauge 24" o.c. • 3" Thermafi ber® SAFB • 1" USG Sheetrock® Brand Gypsum Liner Panels UL Design U415, System C 51 RAL-OT-04-020 Based on 4" C-H studs with 3" Thermafi ber® SAFB insulation SA926 3 wt. 10 35⁄8" • 1/2" USG Durock® Brand Cement Board • 5/8" USG Sheetrock® Brand Firecode® X Panels • 2-1/2" USG C-H studs 20 gauge 24" o.c. • 1-1/2" Thermafi ber® SAFB • 1" USG Sheetrock® Brand Gypsum Liner Panels • USG Durock® Brand Cement Board, screw attached and laminated to gypsum panel with four vertical strip ceramic tile mastic centered between studs UL Design U415, System D SA926 4 wt. 9 31⁄2" • 1/2" USG Sheetrock® Brand Firecode C® Panels • 2-1/2" USG C-H studs 25 gauge 24" o.c. • 1" USG Sheetrock® Brand Gypsum Liner Panels • Joints fi nished both sides UL Design U415, System E or U467 44 USG-040911 Based on 4" C-H studs 25 gauge SA926 5 wt. 10 4" • 1/2" USG Sheetrock® Brand Firecode® C Panels applied vertically, face layer joints fi nished • RC-1 resilient channel or equivalent 24" o.c. • 2-1/2" USG C-H studs 25 gauge 24" o.c. • 1" USG Sheetrock® Brand Gypsum Liner Panels UL Design U415, System F 53 USG-040909 Based on 4" C-H studs 25 gauge with 3" mineral fi ber insulation SA926 6 58 USG-040910 Based on 4" C-H studs 25 gauge with additional layer on liner panel side and 3" mineral fi ber insulation wt. 8 2" 2" • 1" x 2" perimeter angles 25 gauge • 1" USG Sheetrock® Brand Gypsum Liner Panels, fastened to angles • 1/2" USG Sheetrock® Brand Firecode C® Panels, joints fi nished UL Design U529 SA926 7 USG Shaft Wall Systems | 15 SCALE: 1" = 1'-0"1 MECHANICAL CHASE ASSEMBLY-PLAN SCALE: 1" = 1'-0"2 MECHANICAL CHASE ASSEMBLY-SECTION 3 USG SHAFT WALL SYSTEM 09/18/2020 Shaft wall not required at exterior walls: 713.6 Exterior walls. Where exterior walls serve as a part of a required shaft enclosure, such walls shall comply with the requirements of Section 705 for exterior walls and the fireresistance- rated enclosure requirements shall not apply. 1 HR FLOOR ASSEMBLY: FC 5115 SEALANT AROUND DUCT AT PENETRATION. 1 HR SHAFT WALL ASSEMBLY: - 1" USG SHAFT LINER (ATTACHED TO METAL STUDS.) - 1" RIGID INSULATION - 1 LAYER OF TYPE "X" 5/8" GYPSUM Shaft wall required here Listed horizontal 1 hour shaft assembly with penetration protection. Enclose the bottom of the shaft at basement ceiling and it only connects 3 stories and therefore only needs 1 hour fire rating.If there is a horizontal portion of flues, they must also be in the shaft enclosure. Detail it and provide listed 1 hr horizontal shaft assembly. It should look something like this: trock® Brand ed both side eetrock® Bra BLY-SECTION 53 USG-040909 Based on 4" C-H studs 25 SA926 653USG-040909 Based on 4" C-H studs 25 SA926 6 Listed horizontal assembly Use your vertical assembly