HomeMy WebLinkAboutFile Documents.834 W Hallam St.0010.2018 (14).ARBK HealthSafe Inspections Inc 390 Apple Drive Basalt CO 81621 970-920-2100 Jim Baker CDPHE Asbestos Building Inspector, Asbestos Air Monitoring Specialist (AMS) & Project Designer Certification #13437 CDPHE Lead-Based Paint Inspector & Lead Hazard Assessor Certification #23607 ASBESTOS ABATEMENT CLEARANCE REPORT DATE 06/06/2018 CLIENT 834 West Hallam Associates, LLC. c/o Matt Brown 625 E Main St, Suite 102A Aspen CO 81611 PROJECT PROPERTY ADDRESS 834 West Hallam Street, Aspen, Colorado 81611 For orientation purposes, the front door faces south. CLIENT BACKGROUND The Client, 834 West Hallam Associates, LLC., hired HealthSafe Inspections, Inc. (hereinafter, HealthSafe) to perform a post-abatement clearance for the recent abatement of asbestos- containing sheet vinyl flooring layers. The ACM sheet vinyl was abated from the second-floor north restroom and the main floor center restrooms. This required an asbestos abatement permit from the CDPHE (Permit Notice #18P12699A dated 05/04/2018) and a certified asbestos abatement contractor to perform the abatement. Prestige Environmental Services, Inc. provided the asbestos abatement and Matt Brown called for the abatement clearance inspection and PCM air sampling once their abatement of the sheet vinyl flooring layers was completed. VISUAL INSPECTION & LABORATORY FINDINGS An asbestos post-abatement visual clearance inspection and PCM air sampling was conducted by Jim Baker of HealthSafe on Friday May 31, 2018. The visual clearance verified that all friable sheet vinyl flooring had been completely removed from the plywood subfl ooring in the main floor central restrooms and the second-floor north restroom. This visual inspection determined that all lose debris was removed and the remaining subfloors were virtually dust-free. No further abatement or cleaning procedures were required. Following the visual post-abatement clearance, five rotary vane sampling pumps were warmed up for 5 minutes and site calibrated using a rotameter for each location where the abatement took place. A box fan was deployed at a 45°angle off the east wall of the bathroom on the main floor inside the containment and the containment area blown with a leaf blower as required by the regulations for clearances. PCM samples were set in locations representing the distribution of air throughout the containment-abatement space. A trip blank and two field blanks, opened for 30 seconds, were included in the batch of five PCM air samples per location, but were not required to be analyzed by the laboratory. Five PCM air samples were collected inside each containment. The following photos reveal the conditions at the time of inspection and air sampling: HEALTHSAFE PCM LABORATORY DATA Regarding the five PCM air samples in the second-floor bathroom containment, total volumes between 683 and 770 liters of air all had less than 0.005 fibers detected (<0.005 f/cc) per cubic centimeter of air. These five PCM air samples for the second-floor bathroom containment are below the 0.01 f/cc level for clearance. This second-floor restroom passes the abatement requirements. Regarding the five PCM air samples in the first-floor bathroom(s) central restroom area containment, total volumes between 665 and 700 liters of air all had less than 0.005 fibers detected (<0.005 f/cc) per cubic centimeter of air. These five PCM air samples for the first-floor restroom containment are below the 0.01 f/cc level for clearance. The first-floor restroom area passes the abatement requirements. See attached Hayes laboratory report #18016915. CONCLUSIONS Based on the visual post-abatement verification clearance inspections and based on the post- abatement PCM air sampling data for the property at 834 W Hallam St in Aspen, the containment area of the dining and bathrooms spaces has fully passed asbestos abatement clearance criteria. The containments and equipment can be disassembled and removed. Demolition and/or remodeling can commence at once. Sincerely Submitted, Jim Baker HMC #18016915 contact@hayesmicrobial.com http://hayesmicrobial.com/ Analysis Report prepared for HealthSafe Inspections 390 Apple Drive Basalt, CO. 81621 USA Phone: 970-920-2100 Job Name: 834 West Hallam & Assoc. 834 W. Hallam St. Aspen, CO 81611 Date Sampled: 05-31-2018 Date Analyzed: 06-01-2018 Report Date: 06-01-2018 EPA Laboratory ID# VA01419 NVLAP Lab Code: 500096-0 Asbestos License: 300435 License: #PH-0198 Page 1 of 5 HMC #18016915 HealthSafe Inspections 390 Apple Drive Basalt, CO 81621 USA June 1, 2018 Client Job Number: Client Job Name:834 West Hallam & Assoc. 834 W. Hallam St. Aspen, CO 81611 Dear HealthSafe Inspections, We would like to thank you for trusting Hayes Microbial for your analytical needs. On June 1, 2018 we received 10 samples by FedEx for the job referenced above. 10 samples were received in good condition. The results in this analysis pertain only to this job, collected on the stated date and should not be used in the interpretation of any other job. This report may not be duplicated, except in full, without the written consent of Hayes Microbial Consulting, LLC. This laboratory bears no responsibility for sample collection activities, analytical method limitations, or your use of the test results. Interpretation and use of test results are your responsibility. Any reference to health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial Consulting. In no event, shall Hayes Microbial Consulting or any of its employees be liable for lost profits or any special, incidental or consequential damages arising out of your use of the test results. Steve Hayes, BSMT(ASCP) Laboratory Director Hayes Microbial Consulting, LLC Page 2 of 5 HMC #18016915 Asbestos PCM AnalysisHealthSafe Inspections 390 Apple Drive Basalt, CO 81621 USA Phone: 970-920-2100 Job Number: Collected by: Email: Jim Baker healthsafeinspections@gmail.com Job Name:834 West Hallam & Assoc. 834 W. Hallam St. Aspen, CO 81611 Date Collected: Date Received: Date Reported: 05/31/2018 06/01/2018 06/01/2018 page1 HMC ID Number: 18016915 - 4 Sample Media: Air - Asbestos Sample ID Number: 0022 Sample Name: F2-S1 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 770.00 1 / 100 <0.005 HMC ID Number: 18016915 - 5 Sample Media: Air - Asbestos Sample ID Number: 0171 Sample Name: F2-S2 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 732.00 1 / 100 <0.005 HMC ID Number: 18016915 - 6 Sample Media: Air - Asbestos Sample ID Number: 9921 Sample Name: F2-S3 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 751.00 1 / 100 <0.005 HMC ID Number: 18016915 - 7 Sample Media: Air - Asbestos Sample ID Number: 0131 Sample Name: F2-S4 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 751.00 1 / 100 <0.005 HMC ID Number: 18016915 - 8 Sample Media: Air - Asbestos Sample ID Number: 9890 Sample Name: F2-S5 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 683.00 1 / 100 <0.005 Signature: Date:06/01/2018 Reviewed by: Date:06/01/2018 Page 3 of 5 HMC #18016915 Asbestos PCM AnalysisHealthSafe Inspections 390 Apple Drive Basalt, CO 81621 USA Phone: 970-920-2100 Job Number: Collected by: Email: Jim Baker healthsafeinspections@gmail.com Job Name:834 West Hallam & Assoc. 834 W. Hallam St. Aspen, CO 81611 Date Collected: Date Received: Date Reported: 05/31/2018 06/01/2018 06/01/2018 HMC ID Number: 18016915 - 12 Sample Media: Air - Asbestos Sample ID Number: 0162 Sample Name: F1-S1 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 700.00 1 / 100 <0.005 HMC ID Number: 18016915 - 13 Sample Media: Air - Asbestos Sample ID Number: 9908 Sample Name: F1-S2 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 700.00 1 / 100 <0.005 HMC ID Number: 18016915 - 14 Sample Media: Air - Asbestos Sample ID Number: 99932 Sample Name: F1-S3 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 665.00 1 / 100 <0.005 HMC ID Number: 18016915 - 15 Sample Media: Air - Asbestos Sample ID Number: 9903 Sample Name: F1-S4 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 683.00 1 / 100 <0.005 HMC ID Number: 18016915 - 16 Sample Media: Air - Asbestos Sample ID Number: 9982 Sample Name: F1-S5 Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 683.00 1 / 100 <0.005 Signature: Date:06/01/2018 Reviewed by: Date:06/01/2018 Page 4 of 5 HMC #18016915 Asbestos - Additional InformationHealthSafe Inspections 390 Apple Drive Basalt, CO 81621 USA Phone: 970-920-2100 All samples were received in acceptable condition unless otherwise noted on the report. The Report must not be used by the client to claim product certification, approval, or endorsement by: AIHA, NIST, NVLAP NY ELAP, or any agency. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data can be provided when requested. None detected: Below the detected reporting limit of 1% unless point counting is performed, then the detected, reporting limit is .25%. Per NY ELAP198.6 (NOB) TEM is the only reliable method to declare an NOB material as Non-Asbestos Containing. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines. Signature: Date:06/01/2018 Reviewed by: Date:06/01/2018 Page 5 of 5