HomeMy WebLinkAboutFile Documents.834 W Hallam St.0010.2018 (20).ARBK0120.2017.ARBK_BuildingComments_1
Page: A-50A STC RATINGS
File Name: CompletePermitSetClarification3.834Hallam.2018.
07.pdf
Author: bonniem
Subject: PlanCheck
Color:
These STC ratings are based on
dimensional lumber but the
structural plans show TJI
floor/ceiling framing. Select an
assembly that coordinates with
structure.
CompletePermitSetClarification3.834Hallam.2018.07.pdf (4)
Page: A-501 ASEMBLIES
File Name: CompletePermitSetClarification3.834Hallam.2018.
07.pdf
Author: bonniem
Subject: PlanCheck
Color:
Fire ratings from the prescriptive
table in the IBC are based on
dimensional lumber. Revise F-8,
F-3, F-2 to show a listed/tested
floor ceiling assembly for TJIs.
Page: A-501 ASEMBLIES
File Name: CompletePermitSetClarification3.834Hallam.2018.
07.pdf
Author: bonniem
Subject: PlanCheck
Color:
Fire ratings from the prescriptive
table in the IBC are based on
dimensional lumber. Revise
R-4, R-3 to show a listed/tested
floor ceiling assembly for TJIs.
Page: A-501 ASEMBLIES
File Name: CompletePermitSetClarification3.834Hallam.2018.
07.pdf
Author: bonniem
Subject: PlanCheck
Color:
Cedar shingles require a
minimum 1/4" vented airspace
separating the shingles from the
roofing underlayment (Ordinance
40, 2016)
63 CALIFORNIA NOISE CONTROL STC RATINGS P143CALIFORNIA NOISE CONTROL STC RATINGS PG 143160CALIFORNIA NOISE CONTROL STC RATINGS PG 160
These STC ratings arebased on dimensionallumber but the
structural plans show
TJI floor/ceiling
framing. Select an
assembly thatcoordinates withstructure.
PER PLAN
WOOD STUD
5/8" GYP
5/8" GYP
2"
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
CONCRETE REF STRUCT
SCREENED ROCK
RIGID INSULATION; R-5 PER 1"
VAPOR BARRIER
F-1
EXTERIOR FOUNDATION FLOORR-10
FLR + FF - SLAB ON GRADE + FINISH
T.O.SLAB
T.O. FF
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" TYPE X GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
SOUND INSULATION
F-2
UNIT SEPARATION FLOOR
FIRE RATING: 1/2 Hour per IBC Table 722.2.1.4(2)STC: 51 per California Office of Noise Control pg. 143 of 175
T.O.SUBFLOOR
FLR + FF - WD JOIST + FINISH
T.O. FF
B.O.STRUCT
51/2"VIF
CLASS B CEDAR SHINGLES
CLASS A RATED UNDERLAYMENT
FULLY ADHERED ROOF MEMBRANE
SHEATHING REF STRUCT
SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1"
RAISED TIE TRUSS; VIF
CEILING PER PLAN
R-1 EXISTING HISTORIC ROOF STRUCTURE TO REMAINR-34DEMO ASPHALT SHINGLES + REPLACE WITH CEDAR SHINGLES. ADD INSULATIONCLASS A RATED PER ESR-2053
T.O.SHEATHING
SLOPE PERPLAN
PER PLAN
STAGGERED WOOD STUD + SOUND INSULATION
5/8" TYPE X GYP
5/8" ACOUSTICAL TYPE-X GYP
PLYWOOD
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" TYPE X GYP
5/8" TYPE X GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
SOUND INSULATION
F-3
SEPARATION FLOOR BETWEEN UNIT AND TRASH ENCLOSURE
FIRE RATING: 1 Hour per IBC Table 722.2.1.4(2)STC: 51 per California Office of Noise Control pg. 143 of 175
T.O.SUBFLOOR
FLR + FF - WD JOIST + FINISH
T.O. FF
B.O.STRUCT
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
F-4
TYP FLOOR WITHIN UNIT91/2" JOIST
T.O.SUBFLOOR
T.O. FF
B.O.STRUCT
WATERPROOF MEMBRANE
FINISH FLOOR PER PLANS
SOUND CLIP
5/8" GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1"
R-3
T.O.SHEATHING
EXTERIOR FLOOR OVER INTERIORR-49
B.O.STRUCT
PER PLAN
STAGGERED WOOD STUD + SOUND INSULATION
5/8" TYPE X GYP
5/8" ACOUSTICAL TYPE-X GYP
WATERPROOF MEMBRANE
CONCRETE TOPPING REF STRUCT;SLOPE TO DRAIN
SOUND CLIP
5/8" TYPE X GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1"
R-4
T.O.SHEATHING
TRASH ROOM FLOOR OVER INTERIORR-49FIRE RATING: 1 Hour per IBC Table 722.2.1.2(1) + 722.2.1.2(2) + 722.2.1.4(2)STC: 58 per California Office of Noise Control pg 160 of 175
B.O.STRUCT
RIGID INSULATION; R-5 PER 1"
WATERPROOF MEMBRANE
CONCRETE TOPPING; SLOPED FOR DRAINAGE
F-6 SLAB ON GRADE
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
SOUND INSULATION
F-7 TYP FLOOR WITHIN UNIT
T.O.SUBFLOOR
FLR + FF - WD JOIST + FINISH
T.O. FF
B.O.STRUCT
PER PLAN
STAGGERED WOOD STUD + SOUND INSULATION
5/8" TYPE X GYP
5/8" ACOUSTICAL TYPE-X GYP
5/8" TYPE X GYP
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" TYPE X GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
F-8 TYP FLOOR WITHIN UNIT91/2" JOIST
FIRE RATING: 1/2 Hour per IBC Table 722.2.1.4(2)
T.O.SUBFLOOR
T.O. FF
B.O.STRUCT
Fire ratings from the
prescriptive table in
the IBC are based on
dimensional lumber. Revise F-8, F-3, F-2 to
show a listed/testedfloor ceiling assembly
for TJIs.
R-3
T.O.SHEATHING
EXTERIOR FLOOR OVER INTER-49
B.O.
STRUCT
WATERPROOF MEMBRANE
CONCRETE TOPPING REF STRUCT;SLOPE TO DRAIN
SOUND CLIP
5/8" TYPE X GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1"
R-4
T.O.SHEATHING
TRASH ROOM FLOOR OVER INTERIORR-49FIRE RATING: 1 Hour per IBC Table 722.2.1.2(1) + 722.2.1.2(2) + 722.2.1.4(2)STC: 58 per California Office of Noise Control pg 160 of 175
B.O.STRUCT
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
SOUND INSULATION
T.O.SUBFLOOR
T.O. FF
B.O.STRUCT
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" TYPE X GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
T.O.SUBFLOOR
T.O. FF
B.O.STRUCT
Fire ratings from the
prescriptive table in
the IBC are based on
dimensional lumber.
Revise R-4, R-3 to
show a listed/tested
floor ceiling assembly
for TJIs.
51/2"VIF
CLASS B CEDAR SHINGLES
CLASS A RATED UNDERLAYMENT
FULLY ADHERED ROOF MEMBRANE
SHEATHING REF STRUCT
SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1"
RAISED TIE TRUSS; VIF
CEILING PER PLAN
R-1
EXISTING HISTORIC ROOF STRUCTURE TO REMAINR-34DEMO ASPHALT SHINGLES + REPLACE WITH CEDAR SHINGLES. ADD INSULATIONCLASS A RATED PER ESR-2053
T.O.SHEATHING
SLOPE PERPLAN
51/2"
CLASS A RATED ASPHALT SHINGLE
FULLY ADHERED ROOF MEMBRANE
SHEATHING REF STRUCT
SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1"
RAISED TIE TRUSS; REF STRUCT
CEILING PER PLAN
HITECTURAL SHINGLE ROOF
SS A RATED PER UL ER2453-02
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SHEATHING REF STRUCT
JOIST REF STRUCT
SOUND INSULATION
T.O.SUBFLOOR
T.O. FF
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
T.O.SUBFLOOR
T.O. FF
B.O.STRUCT
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SHEATHING REF STRUCT
JOIST REF STRUCT
SPRAY APPLIED CLOSED CELL FOAMINSULATION; R-6.25 PER 1"
SOUND ISOLATION MAT
WOOD VINYL PRODUCT
SOUND CLIP
5/8" TYPE X GYP
SHEATHING REF STRUCT
JOIST REF STRUCT
F-8
TYP FLOOR WITHIN UNIT91/2" JOIST
FIRE RATING: 1/2 Hour per IBC Table 722.2.1.4(2)
T.O.SUBFLOOR
T.O. FF
B.O.STRUCT
Cedar shingles require
a minimum 1/4"
vented airspace
separating the
shingles from the
roofing underlayment
(Ordinance 40, 2016)
FP Response: R-1 Detail has been
revised to include 1/4" min vented airspace.
FP Response: The STC ratings
have been revised to be accurate
for a TJI assembly. Ref ERS-1153
pg 21 on sheet A-500A for the
new compliance
FP Response: The Fire Ratings
are new referenced from the tested
assembly ERS-1153 on sheet A-500G through A-500I.
FP Response: The Fire Ratings
now reference ERS-1153 with
the addition of spray foam to meet
R-Value compliance
08/14/18