Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (33).ACBK Table of Contents Introduction......................................................................................................................................................iii Guidelines........................................................................................................................................................iv VersiGard Reinforced Mechanically Fastened Roofing Systems: UL Approvals: Non-Combustible - ANSI UL - Class A.............................................................................................................5 Combustible - ANSI UL - Class A.....................................................................................................................6 Combustible - ANSI UL - Class B..................................................................................................................... 7 Combustible and Non-Combustible - ANSI UL - Class C................................................................................. 8 Existing UL Rating to Remain - Combustible and Non-Combustible................................................................ 8 FM Approvals: FM Ratings with Mechanically Fastened Membrane - Plates for Versicore MP-H Polyiso.............................. 9 FM Ratings with Mechanically Fastened Membrane - Plates for SecurShield HD............................................ 10 FM Ratings with Mechanically Fastened Membrane - Plates for Dens-Deck/Securock.................................... 11 FM Ratings with Mechanically Fastened Membrane - Plates for HP Recovery Board...................................... 12 FM Ratings with Mechanically Fastened Membrane - Bars.............................................................................. 13 FM Fire Ratings with Mechanically Fastened Membranes................................................................................ 14 1-120 Wind Uplift Equivalency Ratings............................................................................................................ 15 ANSI-SPRI 4474 Approvals with Mechanically Fastened Membrane - Plates.................................................. 16 ANSI-SPRI 4474 Approvals with Mechanically Fastened Membrane - Bars................................................... 17 VersiGard Reinforced Metal Retrofit Roofing Systems: Metal Retrofit..................................................................................................................................................... 18 VersiGard Design "B" Loose Laid Ballasted Roofing Systems: UL Approvals ................................................................................................................................................... 19 FM Criteria....................................................................................................................................................... 19 VersiGard Design "C" Loose Laid Protected Roofing Systems: UL Approvals.................................................................................................................................................... 20 VersiGard FR Nonreinforced, VersiGard Reinforced, VersiGard Reinforced FR and VersiGard White Adhered Roofing Systems: UL Approvals: Non-Combustible - ANSI UL - Class A............................................................................................................. 21 Combustible - ANSI UL - Class A..................................................................................................................... 22 Combustible - ANSI UL - Class B..................................................................................................................... 24 August, 2019 Code Approval Guide X0A0T VersiGard EPDM Codes i 8/2019 CLASS A RATING: REFER TO PAGE 5. 11/27/2019 Combustible and Non-Combustible - ANSI UL - Class C................................................................................. 25 Existing UL Rating to Remain - Combustible ................................................................................................... 25 FM Approvals: SecurShield HD New Construction.................................................................................................................... 26 SecurShield HD Recover................................................................................................................................... 28 SecurShield HD Plus New Construction............................................................................................................ 29 SecurShield HD Plus Recover........................................................................................................................... 31 VersiCore MP-H Polyiso New Construction..................................................................................................... 32 VersiCore MP-H Polyiso Recover..................................................................................................................... 34 SecurShield and SecurShield HD Composite New Construction....................................................................... 35 SecurShield Recover.......................................................................................................................................... 37 Securock New Construction............................................................................................................................... 38 Securock Recover.............................................................................................................................................. 40 DensDeck Prime New Construction................................................................................................................... 41 DensDeck Prime Recover.................................................................................................................................. 44 HP Recovery Board New Construction............................................................................................................. 45 HP Recovery Board Recover............................................................................................................................. 47 Durafacr New Construction............................................................................................................................... 48 Durafacr Recover............................................................................................................................................... 49 DuraStorm VSH New Construction................................................................................................................... 50 DuraStorm VSH Recover................................................................................................................................... 52 Lightweight........................................................................................................................................................ 53 1-165 Wind Uplift Equivalency Ratings (over OSB)......................................................................................... 54 National, State & City Building Code Approvals............................................................................................ 55 State of Florida Evaluation Report................................................................................................................... 55 Reference Notes............................................................................................................................................... 56 VersiGard EPDM Codes ii 8/2019 11/27/2019 Versico Roofing Systems A Division of Carlisle Construction Materials, Incorporated CODE APPROVAL GUIDE August, 2019 INTRODUCTION This Code Approval Guide addresses both general information pertaining to Underwriters Laboratories (UL) and FM Approvals test criteria as well as specific UL and FM code approvals achieved with Versico's Design “A” Adhered, Design “B” Ballasted and Mechanically- Fastened EPDM Roofing Systems. Various independent test laboratory results along with national building code approvals are also identified in this guide. Code approvals available with Versico's VersiFleece, Hot Mopped, VersiFlex and VersiWeld Roofing Systems are identified in separately published Code Approval Guides. Code ratings are categorized by roof system type (Adhered, Ballasted, Mechanically-Fastened) and are separated into 2 sections; UL Approvals and FM Approvals. Underwriters Laboratories rated roof assemblies are grouped according to deck type (non-combustible or combustible) and are further categorized by the severity of fire exposure (Class A, B or C). FM Approval assemblies are categorized according to deck type and the specific type of construction (new, tear-off or retrofit). These ratings can also be found at the FM Approvals web site using RoofNAV (free subscription) at http://roofnav.fmglobal.com/roofnav/login.aspx. The listed assemblies contained in this guide are grouped generically based on deck classification. Specific substrate requirements for each Versico Roofing System can be identified in the respective Versico Specifications. In the UL and FM Approvals throughout this guide, when multiple layers of insulation are referenced, the product listed first identifies the insulation directly below the membrane. For example; a listing of HP Recovery Board/Polyisocyanurate indicates the HP Recovery Board is installed directly under the membrane. A listing of Gypsum Board/Polystyrene indicates the Gypsum Board is installed directly under the membrane. The Table of Contents on the previous pages identifies the sections contained in this publication. << TABLE OF CONTENTS X1A0T VersiGard EPDM Codes iii 8/2019 11/27/2019 General Guidelines for Underwriters Laboratories and FM Approvals Code Compliance These guidelines are intended to focus on the essential criteria to be followed when an Underwriters Laboratories (UL) and/or FM Approvals (FM) approved assembly is specified. Generally, the Versico published specifications reflect the minimum requirements necessary to obtain the applicable Versico warranty. Code requirements are not specifically covered in the Versico specifications and are considered to be above and beyond the provisions of the Versico warranty. Individuals specifying an approved assembly or selecting various products to achieve a specific UL/FM rating must recognize the importance of ensuring proper component selection to fully comply with the most current listings published. All materials used in the roofing system must be UL and/or FM approved and must have been tested together as part of a complete roofing assembly. In addition to the code approval listings in this guide, information pertaining to approved assemblies can also be referenced in the following directories: 1. Underwriters Laboratories On-Line Certifications Directory (ul.com) 2. FM Approvals RoofNav website (roofnav.com). FM RoofNav assembly numbers can be obtained from this website. Underwriters Laboratories, FM Approvals and ANSI/SPRI WD-1 Clarifications/Enhancements UNDERWRITERS LABORATORIES: 1. The criteria required to obtain UL external fire ratings (Class A, B or C) can be identified in this guide or can be searched for on the UL website using the UL category code TGFU. UL ratings approved for use on combustible decks are also acceptable on non-combustible decks. 2. For UL internal fire ratings (hourly constructions - P Numbers), search the UL website using the UL category code BXUV. FM APPROVALS: Uplift ratings listed in this guide are for the field of the roof. Additional requirements/enhancements are required by FM in the perimeter and corner areas, for deck securement and for perimeter nailer/edge attachment. Refer to FM Property Loss Prevention Data Sheets 1-28, 1-29 and 1-49 for specific requirements. On FM insured projects, the local FM insuring agent MUST review and approve the proposed roofing assembly prior to installation. When FM is not the insuring entity for the building, use the Approved American National Standard ANSI/SPRI WD-1 for design purposes. Note: All Versico Roof Systems referenced within this document meet Class 1 construction and Severe Hail (SH) ratings. APPROVED AMERICAN NATIONAL STANDARD ANSI/SPRI WD-1: The ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies should be referenced when a project is not FM insured. This document was developed as a consensus National Standard and provides a methodology for designing for wind uplift resistances of roofing system assemblies. Insulation fastening patterns are included in this document. The fastening patterns are approved for use by Versico. RECOVER Recover approvals in this document are based on the following existing roofing system assumption - the existing Smooth Asphalt BUR, Modified Bitumen or single- ply system was FM approved at the time of installation. SUMMARY Due to complexity of the code documents and the variety of information that must be reviewed, it is important to consult with Versico and other respective manufacturers concerning the most current available approvals. • Prior to project bid - Products specified by the architect must be thoroughly investigated to determine if the specified rating can be achieved and local building codes must be consulted regarding any additional requirements. • Prior to installation - Project managers should review the code requirements with field construction personnel to ensure compliance with project requirements. Upon completion of the roofing installation, each project is inspected by a Versico Technical Representative to ensure compliance with Versico's current specification requirements for the issuance of the applicable warranty. However, this inspection is not for the purpose of verifying code compliance. << TABLE OF CONTENTS X2A0T VersiGard EPDM Codes iv 8/2019 11/27/2019 Membrane Type: VersiGard Reinforced VersiGard Reinforced FR 1 VersiCore MP-H, VersiCore MP-H NH, SecurShield, SecurShield NH, SecurShield HD, SecurShield HD Plus or SecurShield HD Composite- any combination, any thickness N/A 1/2"3/4" 2 Any UL Classified EPS or XPS Insulation, any thickness Minimum 1/2” SecurShield HD, SecurShield HD Plus or SecurShield HD Composite 1"2" 3 Minimum 1” layer of VersiCore MP-H, VersiCore MP-H NH, SecurShield, SecurShield NH, or SecurShield HD Composite over any UL Classified EPS or XPS Insulation, maximum 1.25 pcf, any thickness N/A 1/2"3/4" 4 Insulfoam SP or Insulfoam SP over Insulfoam EPS, any thickness and density N/A 1/2"1/2" 5 Insulfoam HD Composite or Insulfoam HD Composite over Insulfoam EPS, any thickness and density. N/A 1"2" 6 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” SECUROCK® Gypsum- Fiber Board 3"4" 7 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” SECUROCK® Glass-Mat Board 3"4" 8 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” DensDeck/DensDeck Prime Roof Boards 3"4" 9 Any UL Classified Insulation, any thickness (OPTIONAL)Minimum 1/2” HP Recovery Board 1"2-1/2" 10 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 7/16” APA Rated OSB or minimum 1-1/2” StormBase 1"2-1/2" 11 Any UL Classified Insulation, any combination, any thickness Versico FR Base Sheet 1S 1"1" 12 Cellular Lightweight Concrete N/A N/A 1"2-1/2" 13 Precast concrete with grouted joints N/A N/A 1"2-1/2" 14 Structural (poured-in-place) concrete N/A N/A 1"2-1/2" << TABLE OF CONTENTS Non-Combustible Maximum Slope Underwriters Laboratories Approvals VersiGard Reinforced Mechanically-Fastened Roofing System Cover BoardInsulationDeck TypeSystem ID .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane Non-Combustible - ANSI/UL 790 Spread of Flame Test (Class A) Non-Combustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick) X3A0T VersiGard EPDM Codes Page 5 of 57 8/2019 11/27/2019 Membrane Type: VersiGard Reinforced VersiGard Reinforced FR 1 Minimum 1/4” SECUROCK® Gypsum Fiber or Glass Mat Roof Boards (1) Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness.N/A 1/2"3/4" 2 Minimum 1/4” DensDeck/DensDeck Prime Roof Boards (1) Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness.N/A 1/2"3/4" 3 N/A Minimum 3” layer or two layers of 1.5” SecurShield, SecurShield NH or SecurShield HD Composite. (1)(3)N/A 1/2"1/2" 4 N/A Minimum 2-1/2” layer SecurShield, SecurShield NH or SecurShield HD Composite over a 2-1/2” (minimum) layer of Versico VersiCore MP-H Insulation. (1)(4) N/A 1/2"1/2" 5 Versico FR Base Sheet 1S Minimum 1.9” layer of SecurShield, SecurShield NH or SecurShield HD Composite. (1)(4)N/A 1/2"1/2" 6 N/A Minimum 2-1/2” layer of any UL Classified Versico Polyisocyanurate Insulation, any combination. (1) Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2" 7 Versico FR Base Sheet Minimum 1.4” layer of any UL Classified Versico Polyisocyanurate Insulation, any combination. (1) Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2" 8 N/A Minimum 1” layer of SecurShield CD. (1)(5)N/A 1/2"1/2" 9 N/A Minimum 4” layer of any UL Classified EPS Insulation. (1)(6)Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2" 10 N/A Minimum 1” layer of SecurShield CD over a minimum 3-1/2” layer of any UL Classified EPS Insulation. (1)(6)N/A 1/2"1/2" 11 N/A Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness. (OPTIONAL)Minimum 1/2” SecurShield HD FR 1/2"1/2" 12 N/A Minimum 3-1/2 in. layer of any UL Classified EPS insulation. Any UL Classified insulation, any combination, any thickness, may be used below the 4-1/2 in. minimum total thickness Minimum 1/2” SecurShield HD FR 1/2"1/2" 13 N/A Minimum 1-1/2” layer of Insulfoam HD Composite over a minimum 3” layer of Insulfoam EPS. (1)(6)N/A 1/2"1/2" 14 N/A Minimum 2” layer of Insulfoam HD Composite over a minimum 2-1/2” layer of Insulfoam EPS. (1)(6)N/A 1/2"1/2" 15 One Ply of Type G2 (Optional)Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness. Minimum 1/4” SECUROCK® Gypsum Fiber Roof Board (1)3"3" 16 N/A Any UL Classified Insulation, any thickness (OPTIONAL)Minimum 3/8” SECUROCK® Gypsum Fiber Roof Board (1)2"2" 17 N/A Any UL Classified Insulation, any thickness (OPTIONAL)Minimum 1/2” SECUROCK® Gypsum Fiber Roof Board (1)3"4" 18 N/A Any UL Classified Insulation, any thickness (OPTIONAL)Minimum 1/4” SECUROCK® Glass Mat Roof Board (1)3"4" 19 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” DensDeck/DensDeck Prime Roof Boards (1) 3"4" 20 Three layers of Versico FR Base Sheet Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness (OPTIONAL)N/A 1/2"3/4" 21 N/A Any UL Classified Polyiso Insulation, any thickness (OPTIONAL)SecurShield HD FR 1/2'1/2" 22 N/A Minimum 3.5" Layer of and UL Classified EPS Insulation (OPTIONAL)SecurShield HD FR 1/2'1/2" << TABLE OF CONTENTS .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane Underwriters Laboratories Approvals VersiGard Reinforced Mechanically-Fastened Roofing System Combustible - ANSI/UL 790 Spread of Flame Test-Class A System ID Insulation Cover Board (2) Maximum Slope Thermal Barrier/Base Sheet Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) Combustible - ANSI/UL 790 Spread of Flame Test - Class A X4A0T VersiGard EPDM Codes Page 6 of 57 8/2019 11/27/2019 Membrane Type: VersiGard Reinforced VersiGard Reinforced FR 1 N/A Minimum 1.9” layer of SecurShield, SecurShield NH or SecurShield HD Composite. (7)(8)N/A 1/2"1/2" 2 N/A Minimum 1.4” layer of any UL Classified Versico Polyisocyanurate Insulation. (7) Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2" 3 One Layer of Versico FR Base Sheet Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness (OPTIONAL) N/A 1/2"1/2" 4 Inverted G3 cap sheet N/A N/A 1/2"1/2" << TABLE OF CONTENTS Underwriters Laboratories Approvals VersiGard Reinforced Mechanically-Fastened Roofing System Maximum Slope Cover Board Combustible - ANSI/UL 790 Spread of Flame Test-Class B System ID Thermal Barrier/Base Sheet Insulation .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane Combustible - ANSI/UL 790 Spread of Flame Test - Class B Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) VersiGard EPDM Codes Page 7 of 57 8/2019 11/27/2019 Membrane Type: VersiGard Reinforced VersiGard Reinforced FR 1 N/A Any combination, any thickness of UL Classified Versico Polyisocranurate Isulation N/A Unlimited Unlimited 1 N/A Any combination, any thickness of UL Classified Versico Polyisocranurate Isulation N/A Unlimited Unlimited VersiGard Reinforced VersiGard Reinforced FR 1 Non-Combustible and Combustible Existing Class A, B or C roofing System Versico FR Base Sheet 1S (Optional) 2 Non-Combustible and Combustible Existing Class A, B or C built-up or modified bitumen system, (smooth surface, cap sheet or gravel surfaced with gravel maintained). Or Class A, B or C single-ply system (polystyrene in existing single-ply system must be below a coverboard or minimum 1 in. thickness of polyisocyanurate), to retain the existing Classification. Insulfoam "R-TECH" Type "I", "VIII", "II", "IX" or "FanFold" 1 in. max thickness. 1/2"1/2" Underwriters Laboratories Approvals VersiGard Reinforced Mechanically-Fastened Roofing System System ID Thermal Barrier/Base Sheet Insulation Cover Board Maximum Slope Non-Combustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick) Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane Maximum Slope Combustible - ANSI/UL 790 Spread of Flame Test-Class C Non-Combustible - ANSI/UL 790 Spread of Flame Test-Class C << TABLE OF CONTENTS Combustible and Non-Combustible - ANSI/UL 790 Spread of Flame Test (Class C) Existing UL Rating Retained Non-Combustible and Combustible (Directly over existing Class A, B or C) System ID Deck Type Existing Substrate Insulation Maximum slope shall be in accordance with Classification established for the existing roofing system but cannot exceed 1-1/2:12 X6A0T VersiGard EPDM Codes Page 8 of 57 8/2019 11/27/2019 Membrane Type: (10) VersiGard Reinforced VersiGard Reinforced FR VersiGard Reinforced VersiGard Reinforced FR 1-90 (350373-0-0) 12”1-60 1-60 1-60 1-60 1-105 (350372-0-0) 12”1-60 (5186-0-0)1-60 1-60 1-60 HP Fastener / 2” Polymer Plate 6”1-90 1-90 1-90 1-90 HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”1-90 (381749-0-0)1-90 1-90 1-90 1-75 1-105 1-105 (350375-0-0)(179770-0-0)(179094-0-0) 1-60 1-60 (182024-0-0)(182017-0-0) 1-90 1-90 (222334-0-0)(222332-0-0) 1-90 1-90 (5460-0-0)(5146-0-0) 1-90 1-90 (222334-0-0)(222332-0-0) << TABLE OF CONTENTS 1-90 1-90 1-90 VersiGard Reinforced Mechanically Fastened Roofing System with Plates for VersiCore MP-H Polyiso HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 10’ with 9” QA RTS splitting sheet HP Fastener / 2” Polymer Plate 5’HP Fastener / 2” Polymer Plate 1-75 6” Membrane Width Fastener/Plate Spacing Min. 22-gauge Grade C Steel Min. 22-gauge Grade E Steel or Structural Concrete (11) 1-1056”1-105 6” 1-105 12”1-75 (409511-0-0) 12”- 1-75 - (RoofNAV numbers) for steel decks FM Approvals .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane (12) 10’ HP Fastener / 2” Polymer Plate 6”-- HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”-- 6’-6” 8’ HP Fastener / 2” Polymer Plate X7A0T VersiGard EPDM Codes Page 9 of 57 8/2019 11/27/2019 Membrane Type: (10) VersiGard Reinforced VersiGard Reinforced FR VersiGard Reinforced VersiGard Reinforced FR 1-90 12”1-60 1-60 1-60 1-60 1-105 12”1-60 1-60 1-60 1-60 HP Fastener / 2” Polymer Plate 6”1-90 1-90 1-90 1-90 HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”1-90 1-90 1-90 1-90 1-75 1-105 1-105 1-60 1-60 1-90 1-90 1-90 1-90 1-90 1-90 FM Approvals VersiGard Reinforced Mechanically Fastened Roofing System with Plates for SecurShield HD .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane (12) Membrane Width Fastener/Plate Spacing Min. 22-gauge Grade C Steel Min. 22-gauge Grade E Steel or Structural Concrete (11) 1-105 10’ with 9” QA RTS splitting sheet HP Fastener / 2” Polymer Plate 6”1-90 1-90 1-90 5’HP Fastener / 2” Polymer Plate 6”1-105 1-105 6’-6” 8’ HP Fastener / 2” Polymer Plate 6”1-75 12”-- HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12” - (RoofNAV numbers) for steel decks << TABLE OF CONTENTS 1-75 1-75 10’ HP Fastener / 2” Polymer Plate 6”-- HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”- VersiGard EPDM Codes Page 10 of 57 8/2019 11/27/2019 Membrane Type: (10) VersiGard Reinforced VersiGard Reinforced FR VersiGard Reinforced VersiGard Reinforced FR 1-90 12”1-60 1-60 1-60 1-60 1-105 12”1-60 1-60 1-60 1-60 HP Fastener / 2” Polymer Plate 6”1-90 1-90 1-90 1-90 HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”1-90 1-90 1-90 1-90 1-75 1-105 1-105 1-60 1-60 1-90 1-90 1-90 1-90 1-90 1-90 FM Approvals VersiGard Reinforced Mechanically Fastened Roofing System with Plates for Dens-Deck/Securock .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane (12) Membrane Width Fastener/Plate Spacing Min. 22-gauge Grade C Steel Min. 22-gauge Grade E Steel or Structural Concrete (11) 1-105 10’ with 9” QA RTS splitting sheet HP Fastener / 2” Polymer Plate 6”1-90 1-90 1-90 5’HP Fastener / 2” Polymer Plate 6”1-105 1-105 6’-6” 8’ HP Fastener / 2” Polymer Plate 6”1-75 12”-- HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12” - (RoofNAV numbers) for steel decks << TABLE OF CONTENTS 1-75 1-75 10’ HP Fastener / 2” Polymer Plate 6”-- HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”- VersiGard EPDM Codes Page 11 of 57 8/2019 11/27/2019 Membrane Type: (10) VersiGard Reinforced VersiGard Reinforced FR VersiGard Reinforced VersiGard Reinforced FR 1-90 12”1-60 1-60 1-60 1-60 1-105 12”1-60 1-60 1-60 1-60 HP Fastener / 2” Polymer Plate 6”1-90 1-90 1-90 1-90 HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”1-90 1-90 1-90 1-90 1-75 1-105 1-105 1-60 1-60 1-90 1-90 1-90 1-90 1-90 1-90 FM Approvals VersiGard Reinforced Mechanically Fastened Roofing System with Plates for Hp Recovery Board .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane (12) Membrane Width Fastener/Plate Spacing Min. 22-gauge Grade C Steel Min. 22-gauge Grade E Steel or Structural Concrete (11) 1-105 10’ with 9” QA RTS splitting sheet HP Fastener / 2” Polymer Plate 6”1-90 1-90 1-90 5’HP Fastener / 2” Polymer Plate 6”1-105 1-105 6’-6” 8’ HP Fastener / 2” Polymer Plate 6”1-75 12”-- HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12” - (RoofNAV numbers) for steel decks << TABLE OF CONTENTS 1-75 1-75 10’ HP Fastener / 2” Polymer Plate 6”-- HPVXtra Fastener / 2-3/8” HPVXtra Polymer Seam Plate 12”- VersiGard EPDM Codes Page 12 of 57 8/2019 11/27/2019 Membrane Type: (16) 10'6" o.c.1-90 (144041-0-0) -Polymer Batten 8'6" o.c.1-120 (181911-0-0) 1-75 (333566-0-0)Polymer Batten 8’12” o.c.1-60 (181530-0-0) 1-60 (181530-0-0)Polymer Batten 5’12” o.c.1-90 (305374-0-0) 1-90 (350374-0-0)Metal Fastening Bar << TABLE OF CONTENTS FM Approvals VersiGard Reinforced Mechanically Fastened Roofing System with Bars .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane FM Uplift Rating (16) Versico HPVX Fastener With Polymer Batten or Metal Fastening BarsSteel (Min.22-gauge) Decks (14)(15) Grade E Steel Decks (13)(15) or Structural Concrete FM Approved Deck Type Field Sheet Width Max. Fastener Spacing (RoofNAV Number) Steel (15) or Structural Concrete HPVX Fasteners (steel decks); CD-10 or HD 14-10 (Concrete Decks) X11A0T VersiGard EPDM Codes Page 13 of 57 8/2019 11/27/2019 Membrane Type: VersiGard Reinforced VersiGard Reinforced FR HP Recovery Board, SecurShield HD or SecurShield HD Plus over FM approved Insulation 1/2" Min. Refer to FM RoofNav website Polyisocyanurate VersiCore MP-H 1-1/2"-36"1/2”1-1/2” VersiGard Reinforced VersiGard Reinforced FR Polyisocyanurate VersiCore MP-H 1" Max.1/2”1-1/2” 1"3-1/2" New Construction/Tearoff: Steel (Min. 22-gauge) Structural Concrete Wood (18) Tectum Retrofit (No Tearoff) (19) Structural Concrete HP Recovery Board (min. 1/2"), SecurShield HD, or SecurShield HD Plus or (min. 1/4") DensDeck Prime or Securock over: FM approved Insulation (17) FM Fire Ratings VersiGard Reinforced Mechanically Fastened Roofing Systems Deck Type Insulation Insulation Thickness Maximum Slope for ASTM E-108 Class “A” Rating .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane << TABLE OF CONTENTS 1/2"-1" Deck Type Insulation Insulation Thickness Maximum Slope for ASTM E-108 Class “A” Rating 1"3-1/2"Retrofit (No Tearoff) (19): Steel (Min. 22 guage) Wood (18) Tectum HP Recovery Board, SecurShield HD or SecurShield HD Plus X12A0T VersiGard EPDM Codes Page 14 of 57 8/2019 11/27/2019 Insulation Minimum Thickness Insulation Fastening Density Any approved insulation Minimum Approved Thickness (21)1 per 8 square feet << TABLE OF CONTENTS * A formal FM Approvals (FM) Class 1-120 rating is available using 10-foot wide VersiGard Reinforced .075” EPDM membrane and HP Fasteners/Polymer Plates. VersiGard Reinforced Mechanically-Fastened Roofing Systems 1-120 (120 psf) Wind Uplift Equivalency Ratings* 120 psf Uplift Resistance* (1-120 Approval Equivalency on 12' X 24' Table) (20) Maximum 7 foot wide VersiGard Reinforced .060" thick EPDM membrane with Versico HPV Fasteners and 2" diameter Polymer Seam Plates spaced 6" on center. * Membrane Requirements: Wind uplift testing has been completed in accordance with the FM Approvals 4470 Test Procedure which was witnessed and certified by Architectural Testing, Incorporated, an industry recognized Independent Testing Laboratory. Over a 22-gauge steel roof deck, the following results were obtained. (Performance Test Report is on file and available from Versico.) X13A0T VersiGard EPDM Codes Page 15 of 57 8/2019 11/27/2019 Membrane Type: (22) HP Fasteners (wood); CD-10 or HD 14-10 (concrete) HP Fasteners (wood); CD-10 or HD 14-10 (concrete) HP Fasteners (steel/wood); CD-10 or HD 14-10 (concrete) HP Fasteners (steel); CD-10 or HD 14-10 (concrete) Steel (min. 22-gauge)10’6” o.c.Polymer HP Fastener 1-105 HP Fasteners (steel/wood); CD-10 or HD 14-10 (concrete) 6" o.c.HP Fasteners (steel);1-120 12” o.c.CD-10 or HD 14-10 (concrete)1-60 10’ ANSI-SPRI 4474 Approvals With Plates 1-90 Required Fastening Plates Steel (min. 22-gauge) VersiGard Reinforced Mechanically-Fastened Roofing System .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane Max. Fastener Spacing Field Sheet Width 10’12” o.c.2-3/8” HPVXtra Polymer Seam Plate Grade E Steel or Structural Concrete Polymer 6" o.c. 12” o.c. Polymer8’6” o.c. HPVXtra Fastener 1-90 << TABLE OF CONTENTS Polymer 12” o.c.2-3/8” HPVXtra Polymer Seam Plate Approved Deck Type Versico Fastener Uplift Wood or Structural Concrete 10’6” o.c.Seam Fastening Plates 1-90 Grade E Steel or Structural Concrete 8’ Steel (min. 22-gauge), Wood or Structural Concrete VersiGard Reinforced .060” or .075” only Polymer Steel (min. 22-gauge) or Structural Concrete 10' HPVXtra Fastener 1-75 1-105 10' Grade E Steel or Structural Concrete 10'6" o.c.Polymer 1-105 Grade E Steel X14A0T VersiGard EPDM Codes Page 16 of 57 8/2019 11/27/2019 Membrane Type: (23) Grade E Steel Decks or Structural Concrete Steel (Min.22-gauge) Decks 10'6" o.c.1-90 1-90 8'6" o.c.1-120 1-120 8’12” o.c.1-60 1-60 << TABLE OF CONTENTS Approved Deck Type Steel or Structural Concrete HPVX Fasteners (steel decks); CD-10 or HD 14-10 (Concrete Decks) VersiGard Reinforced Mechanically-Fastened Roofing System ANSI-SPRI 4474 Approvals With Bars .045", .060" or .075" VersiGard Reinforced or VersiGard Reinforced FR EPDM Membrane Uplift Rating Versico HPVX Fastener With Polymer Batten or Metal Fastening Bars Max. Fastener Spacing Field Sheet Width X15A0T VersiGard EPDM Codes Page 17 of 57 8/2019 11/27/2019 FM APPROVALS HD HP-R 273639-0-0 MP-H 80-DD/SR 60-DD/SR HD HP-R 273732-0-0 MP-H 80-DD/SR 60-DD/SR HD HP-R MP-H 80-DD/SR 60-DD/SR HD HP-R MP-H 80-DD/SR 60-DD/SR SURE-SEAL METAL RETROFIT ROOFING SYSTEM Coverboard << TABLE OF CONTENTS The UL ratings achieved with the Metal Retrofit Roofing System are identical to the approvals listed for the VersiGard Reinforced Mechanically-Fastened Roofing System over non- combustible decks depending on the membrane selected (Standard Reinforced or FR Reinforced EPDM). Click here for ratings. As referenced in FM Approvals Loss Prevention Data Sheet 1-31, the method of recovering an existing metal roof system with a single-ply mechanically fastened roofing system where the membrane is secured through the existing metal roof directly to the structural purlins is recognized as an appropriate recovery system when installed per the recommendations of FM. FM Approvals has accepted the securement of Versico's reinforced EPDM membrane with RTS (Reinforced Universal Securement Strip) as an alternate to "in-seam fastening" as used in our VersiGard Reinforced Mechanically-Fastened Roofing System. As such, the wind uplift resistance of the VersiGard Metal Retrofit Roofing System will be equivalent to an FM 1-90 system when structural purlins are spaced a maximum of 6-1/2' on center and the RTS is secured with Versico HP or Purlin Fasteners and Polymer Seam Plates a maximum of 6" on center into the purlins. For FM Class 60 wind uplift equivalency, the purlins could be spaced a maximum of 6-1/2' on center with the RTS secured with Versico Fasteners and 2" diameter Polymer Seam Plates spaced a maximum of 12" on center into the purlins. As a standard FM Approvals requirement, additional membrane and insulation securement is necessary in the corner and/or perimeter areas as outlined in FM Loss Prevention Data Sheets 1- 28, 1-29 and 1-31. These bulletins should be reviewed in their entirety for specific requirements concerning insulation types, fastening enhancements and other items that may be necessary. FM Approvals – Metal Retrofit Pressure-Sensitive RTS Strip FM Approvals – Metal Retrofit 6" 12" Rating 1-60 1-90 60 Inches HP Purlin/2" Polymer Purlin Spacing Fastener/Plate Spacing VersiGard Reinforced and VersiGard Reinforced FR Spacing 60 Inches HP Purlin/2" Polymer Purlin Spacing Fastener/Plate Coverboard VersiGard Reinforced and VersiGard Reinforced FR UNDERWRITERS LABORATORIES (UL) APPROVALS 6" 12" Rating 1-105 1-60 X16A0T VersiGard EPDM Codes Page 18 of 57 8/2019 11/27/2019 Membrane Type: Insulation (UL Classified) Non-Combustible and Combustible Any UL Classified Insulation Any New Construction: Approved Lightweight Insulating Concrete 3 Minutes 5 Minutes 10 Minutes Average FM Class 1 Standard 385 365 340 270 Allowable Deviation 25 25 20 15 Test Panel No. 2 *124 103 88 31 << TABLE OF CONTENTS 2" Deck Type Insulation Thickness Underwriters Laboratories Approvals Design "B" Loose Laid Ballasterd Roofing Systems (24)(25) .045" or .060" VersiGard FR Non-Reinforced EPDM Membrane .060" or .075" VersiGard Reinforced EPDM Membrane Maximum Slope UL Class "A" All constructions listed in the FM Approvals (FM) Approval Guide are Class 1 A, B or C fire rated and minimum Class 60 uplift rated. Because of the nature of the uplift testing (pressurizing the underside of the deck to minimum 60 pounds per square foot), ballasted systems cannot be tested. If the ballasted system was tested, it would only require approximately 10-15 pounds per square foot of uplift pressure before movement of the stone and membrane would occur. In reality, ballasted systems are capable of resisting much higher wind forces. Although ballasted systems are not formally FM approved, FM Approvals conducted research fire tests on Versico's VersiGard Design "B" Ballasted Roofing System. Two (2) test panels were constructed which consisted of a 22-gauge steel deck, 5/8" thick Type X core gypsum board, 0.0015" aluminum vapor retarded and 4-1/4" VersiGard EPS insulation. The following results were obtained: None or HP Protective Mat (Refer to Versico Specifications for requirements)N/A 2" FM Laboratories Approvals Calorimeter Tests for the Design "B" Ballasted Roofing System The conclusion of the research report was that the Ballasted System Panels had met the fire hazard requirement for Class 1 insulated steel deck roof construction. Additionally, FM Approvals has published Loss Prevention Data Sheet 1-29, Above Deck Roof components that outlines general guidelines for ballast criteria depending on project conditions (building height, parapet height, location, etc.). According to this bulletin, FM Approvals' loss experience has been very favorable for single-ply Ballasted Roofing Systems when designed in accordance with this published criteria. Although FM does not formally approve Ballasted Systems, job-by-job acceptance can be obtained when FM Approvals is the insurance underwriter by contacting the local FM office for requirements. Maximum Average Rate of Fuel Contribution (Btu/Square Feet/Minutes) for various intervals of time * The fuel contribution rates developed for Test Panel No. 2 were equivalent to Test Panel No. 1 X17A0T VersiGard EPDM Codes Page 19 of 57 8/2019 11/27/2019 Membrane Type: Foamular 404 8" Max.2" Dow Styrofoam Roofmate or Plazamate 4" Max.2" << TABLE OF CONTENTS Underwriters Laboratories Approvals Design "C" Loose Laid Protected Roofing System (26)(27) UL Class "A" Deck Type Insulation (28)Insulation Thickness Maximum Slope Non-Combustible and Combustible .045" or .060 VersiGard FR Non-Reinforced EPDM Membrane .060" or .075" Sure-Though EPDM Membrane X18A0T VersiGard EPDM Codes Page 20 of 57 8/2019 11/27/2019 Membrane Adhesive: Membrane Type: VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White 1 VersiCore MP-H, SecurShield, SecurShield HD, SecurShield HD Plus or SecurShield HD Composite-any combination, any thickness N/A 1/2"1/2"3/4"1/2" 2 Any UL Classified EPS or XPS Insulation, any thickness Minimum 1/2” SecurShield HD, SecurShield HD Plus or SecurShield HD Composite 1"1"2"1-1/2" 3 Minimum 1” layer of VersiCore MP-H, SecurShield, or SecurShield HD Composite over any UL Classified EPS or XPS Insulation, maximum 1.25 pcf, any thickness N/A 1/2"1/2"3/4"1/2" 4 Insulfoam HD Composite or Insulfoam HD Composite over Insulfoam EPS, any thickness and density. N/A 1/2"1/2"3/4"1/2" 5 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” SECUROCK® Gypsum-Fiber Roof Board Unlimited (3"-CG3V)3"4"3" (2"-CG3V) 6 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” DensDeck Prime Roof Board Unlimited (3"-CG3V)3"4"3" (2"-CG3V) 7 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/2” HP Recovery Board 1"1"2-1/2"1-1/2" (1"-CG3V) 8 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 7/16” APA Rated OSB or minimum 1.5” StormBase 1"1"2-1/2"1-1/2" (1"-CG3V) 9 Cellular Lightweight Concrete N/A N/A 1"1"2-1/2"1-1/2" (1"-CG3V) 10 Precast concrete with grouted joints N/A N/A 1"1"2-1/2"1-1/2" (1"-CG3V) 11 Structural (poured-in- place) concrete N/A N/A 1"1"2-1/2"1-1/2" (1"-CG3V) Non-Combustible << TABLE OF CONTENTS Underwriters Laboratories Approvals Design "A" Adhered Roofing Systems Non-Combustible - ANSI/UL 790 Spread of Flame Test - Class A VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045", .060", or .075" VersiGard White .060" or .090 Non-Combustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick) System ID Deck Type Insulation Cover Board Maximum Slope Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) or Cav-Grip 3V X19A0T VersiGard EPDM Codes Page 21 of 57 8/2019 11/27/2019 Membrane Adhesive: Membrane Type: VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White 1 Minimum 1/4” SECUROCK® Gypsum Fiber Roof Boards (29) Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness.N/A 1/2"1/2"1/2"1/2" 2 Minimum 1/4” DensDeck Prime Roof Boards (29) Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness.N/A 1/2"1/2"1/2"1/2" 3 N/A Minimum 3” layer or two layers of 1.5” SecurShield or SecurShield HD Composite. (29)(31)N/A 1/2"1/2"1/2"1/2" 4 N/A Minimum 2.5” layer SecurShield or SecurShield HD Composite over a 2.5” (minimum) layer of Versico VersiCore MP-H Insulation. (29)(32) N/A 1/2"1/2"1/2"1/2" 5 Versico FR Base Sheet Minimum 1.9” layer of SecurShield or SecurShield HD Composite. (29)(32)N/A 1/2"1/2"1/2"1/2" 6 N/A Minimum 2.5” layer of any UL Classified Versico Polyisocyanurate Insulation, any combination. (29) Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2"1/2"1/2" 7 Versico FR Base Sheet Minimum 1.4” layer of any UL Classified Versico Polyisocyanurate Insulation, any combination. (29) Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2"1/2"1/2" 8 N/A Minimum 1” layer of SecurShield CD. (29)(33)N/A 1/2"1/2"1/2"1/2" 9 N/A Minimum 4” layer of any UL Classified EPS Insulation. (29)(34) Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2"1/2"1/2" 10 N/A Minimum 1” layer of SecurShield CD over a minimum 3-1/2” layer of any UL Classified EPS Insulation. (29)(34) N/A 1/2"1/2"1/2"1/2" 11 N/A Minimum 1-1/2” layer of Insulfoam HD Composite over a minimum 3” layer of Insulfoam EPS. (29)(34)N/A 1/2"1/2"1/2"1/2" 12 N/A Minimum 2” layer of Insulfoam HD Composite over a minimum 2.5” layer of Insulfoam EPS. (29)(34)N/A 1/2"1/2"1/2"1/2" 13 N/A Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness. Minimum 1/4” SECUROCK® Gypsum Fiber Roof Board (29) Unlimited (3"-CG3V)3"4"3" (2"-CG3V) Underwriters Laboratories Approvals Design "A" Adhered Roofing Systems UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test - Class A VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045", .060", or .075" VersiGard White .060" or .090 Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) System ID Thermal Barrier/Base Sheet Insulation Cover Board (30) Maximum Slope Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) or Cav-Grip 3V Combustible - ANSI/UL 790 Spread of Flame Test-Class A X20A0T VersiGard EPDM Codes Page 22 of 57 8/2019 11/27/2019 Membrane Adhesive: Membrane Type: VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White Underwriters Laboratories Approvals Design "A" Adhered Roofing Systems UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test - Class A VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045", .060", or .075" VersiGard White .060" or .090 Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) System ID Thermal Barrier/Base Sheet Insulation Cover Board (30) Maximum Slope Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) or Cav-Grip 3V Combustible - ANSI/UL 790 Spread of Flame Test-Class A X20A0T 14 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 3/8” SECUROCK® Gypsum Fiber Roof Board (29) 2"2"2"2" 15 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/2” SECUROCK® Gypsum Fiber Roof Board (29) Unlimited (3"-CG3V)3"4"3" (2"-CG3V) 16 One Ply of Type G2 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” SECUROCK® Gypsum Fiber Roof Board (29) 3"3"3"3" (2"-CG3V) 17 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4” DensDeck Prime Roof Boards (29) Unlimited (3"-CG3V)3"4"3" (2"-CG3V) 18 Three or Two layers of Versico FR Base Sheet Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness.N/A 1/2"1/2"1/2"1/2" 19 N/A Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness. (Optional)SecurShield HD FR 1/2"1/2"1/2"1/2" 20 N/A Minimum 3.5" layer of Any UL Classified EPS insulation (Optional)SecurShield HD FR 1/2"1/2"1/2"1/2" << TABLE OF CONTENTS VersiGard EPDM Codes Page 23 of 57 8/2019 11/27/2019 Membrane Adhesive: Membrane Type: VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White 1 N/A Minimum 1.9” layer of SecurShield or SecurShield HD Composite. (35)(36)N/A 1/2"1/2"1/2"1/2" 2 N/A Minimum 1.4” layer of any UL Classified Versico Polyisocyanurate Insulation. (35) Minimum 1/2” SecurShield HD or SecurShield HD Plus 1/2"1/2"1/2"1/2" 3 N/A Minimum 1” layer of SecurShield CD. (35)(37)N/A 1/2"1/2"1/2"1/2" << TABLE OF CONTENTS Combustible - ANSI/UL 790 Spread of Flame Test-Class B Underwriters Laboratories Approvals Design "A" Adhered Roofing Systems Combustible - ANSI/UL 790 Spread of Flame Test - Class B VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045", .060", or .075" VersiGard White .060" or .090 Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) System ID Thermal Barrier/Base Sheet Insulation Cover Board Maximum Slope Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) or Cav-Grip 3V X21A0T VersiGard EPDM Codes Page 24 of 57 8/2019 11/27/2019 Membrane Adhesive: Membrane Type: VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White 1 N/A 2" layer of any UL Classified Versico Polyisocranurate Isulation N/A Unlimited Unlimited Unlimited Unlimited 1 N/A Any layer of UL Classified Versico Polyisocyanurate Insulation.N/A Unlimited Unlimited Unlimited Unlimited Membrane Type: VersiGard FR Nonreinforced VersiGard White 1 N/A Existing min. UL Class "C" rated Type III or IV Smooth Asphalt BUR, Mineral Cap Sheet or Modified Bitumen to remain None 90-8-30A/Low VOC 1/2"1/2" Maximum Slope Combustible - ANSI/UL 790 Spread of Flame Test-Class C Non-Combustible - ANSI/UL 790 Spread of Flame Test-Class C Underwriters Laboratories Approvals Design "A" Adhered Roofing Systems Combustible and Non-Combustible - ANSI/UL 790 Spread of Flame Test (Class C) Non-Combustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick) System ID Thermal Barrier/Base Sheet Insulation Cover Board Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045", .060", or .075" VersiGard White .060" or .090 Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) or Cav-Grip 3V VersiGard FR Nonreinforced .045', .060" or .090" VersiGard White .060" or .090 Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) Existing UL Rating Retained Combustible (Directly over existing Class A, B or C) Insulation << TABLE OF CONTENTS System ID Deck Type Existing Substrate Bonding Adhesive Maximum Slope X22A0T VersiGard EPDM Codes Page 25 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approved Loose laid 1/2" SecurShield HD 12 (2.67 sq. ft)1-75 284927-0-0 (90-8-30A)--- FM Approved Loose laid 1/2" SecurShield HD 16 (2 sq. ft)1-90 385922-0-0 385912-0-0 385923-0-0 (90-8-30A)385913-0-0 Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.) 1/2" SecurShield HD 6" ribbions of DASH 1-90 409971-0-0 410028-0-0 410008-0-0 410009-0-0 Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft) 1/2" SecurShield HD 6" ribbions of DASH 1-90 409983-0-0 410031-0-0 410032-0-0 410033-0-0 Min. 2" Insulfoam EPS over 1/2" Dens-Deck 16 (2 sq. ft.)1/2" SecurShield HD 6" ribbions of DASH 1-90 427332-0-0 427351-0-0 427352-0-0 427353-0-0 Min. 1-1/2" VersiCore MP-H Polyiso 24 (1.33 sq. ft.)1/2" SecurShield HD 4" ribbions of DASH 1-165 325931-0-0 (90-8-30A) 325996-0-0 (90-8-30A) 325998-0-0 (90-8-30A)- Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.)SecurShield HD over VersiCore MP-H Polyiso 6" ribbions of DASH 1-90 ---- Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.) 1/2" SecurShield HD over Min. 1-1/2" VersiCore MP- H Polyiso 6" ribbions of DASH 1-90 389422-0-0 404115-0-0 404116-0-0 404125-0-0 Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1/2" SecurShield HD 12" ribbions of DASH 1-315 343383-0-0 344366-0-0 -344369-0-0 Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA 1/2" SecurShield HD 12" ribbons of Olybond 500 BA 1-240 ---- Min. 1/2" VersiCore MP-H Polyiso Hot Asphalt 1/2" SecurShield HD Hot Asphalt 1-240 ---- Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-120 438091-0-0 (90-8-30A)-438100-0-0 (90-8-30A)- Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-120 --438102-0-0 (LVOC)438103-0-0 Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-90 -438097-0-0 (LVOC)-- Min. 2" Insulfoam EPS 12" ribbions of DASH 1/2" SecurShield HD 12" ribbions of DASH 1-285 429674-0-0 429685-0-0 429686-0-0 429687-0-0 Min. 2" ChannelDry EPS Loose laid 1/2" SecurShield HD over Min. 2" SecurShield Polyiso 8 (4 sq. ft)1-90 441959-0-0 441960-0-0 441961-0-0 441962-0-0 Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Versico One Step 1/2" SecurShield HD 12" ribbons of Versico One Step 1-255 ---- Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-165 702 -437582-0-0 (90-8-30A)-437587-0-0 Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-105 702 437577-0-0 (90-8-30A)--- Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-90 702 -437583-0-0 (LVOC)-- Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-120 702 --437585-0-0 (90-8-30A)- Min. 3/4" Optim-R 6" ribbons of FAST 1/2" SecurShield HD 6" ribbons of FAST 1-150 702 --437586-0-0 (LVOC)- 1-255 Cav-Grip ---424132-0-0 1-150 702 LV 364530-0-0 364572-0-0 364609-0-0 364613-0-0 1-90 702 ---- FM Approvals Design "A" Adhered Roofing Systems VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" SecurShield HD Ratings - New Construction Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1/2" SecurShield HD 12" ribbions of DASH RoofNAV Number Steel Deck (Min. 22-Gauge) Concrete Deck Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard WhiteBase Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) X23A0T VersiGard EPDM Codes Page 26 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approvals Design "A" Adhered Roofing Systems VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" SecurShield HD Ratings - New Construction RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard WhiteBase Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) X23A0T 1-255 Cav-Grip 429677-0-0 429694-0-0 429696-0-0 429697-0-0 1-195 702 LV 429679-0-0 429701-0-0 429702-0-0 429703-0-0 1-135 702 429680-0-0 429704-0-0 429705-0-0 429706-0-0 Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1/2" SecurShield HD 12" ribbions of DASH 1-150 392983-0-0 392987-0-0 392991-0-0 392998-0-0 Min. 1-1/2" VersiCore MP-H Polyiso Full-Coverage DASH 1/2" SecurShield HD Full-Coverage DASH 1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA 1/2" SecurShield HD 12" ribbons of Olybond 500 BA 1-90 ---- FM Approved Loose laid 1/2" SecurShield HD 12 (2.67 sq. ft)1-75 ---- FM Approved Loose laid 1/2" SecurShield HD 16 (2 sq. ft)1-90 ---- -- 1/2" SecurShield HD 12 (2.67 sq. ft)1-75 ---- -- 1/2" SecurShield HD 16 (2 sq. ft)1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 4" ribbions of DASH 1/2" SecurShield HD 4" ribbions of DASH 1-135 ---- -- 1/2" SecurShield HD 4" ribbions of DASH 1-135 ---- Min. 1/2" VersiCore MP-H Polyiso 4" ribbions of DASH 1/2" SecurShield HD 4" ribbions of DASH 1-135 ---- -- 1/2" SecurShield HD 4" ribbions of DASH 1-135 ---- << TABLE OF CONTENTS (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking Gypsum Deck Tear-Off Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer 12" ribbions of DASH 1/2" SecurShield HD12" ribbions of DASH Min. 2" Insulfoam EPS VersiGard EPDM Codes Page 27 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: --1/2" SecurShield HD 12 (2.67 sq. ft)1-75 295759-0-0 (90-8-30A) 299369-0-0 (90-8-30A) 296329-0-0 (90-8-30A)- --1/2" SecurShield HD 16 (2 sq. ft)1-90 427370-0-0 427472-0-0 427473-0-0 427474-0-0 --1/2" SecurShield HD 6" ribbions of DASH 1-90 309444-0-0 309401-0-0 309461-0-0 - --1/2" SecurShield HD 4" ribbions of DASH 1-150 ---- Min. 1/2" VersiCore MP-H Polyiso 6" ribbions of DASH 1/2" SecurShield HD 6" ribbions of DASH 1-150 ---- --1/2" SecurShield HD 6" ribbions of DASH 1-150 ---- --1/2" SecurShield HD 6" ribbions of DASH 1-90 ---- --1/2" SecurShield HD 12" ribbons of Olybond 500 BA 1-90 ---- VersiGard White << TABLE OF CONTENTS Gypsum Deck Tear-Off FM Approvals Design "A" Adhered Roofing Systems VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Steel Deck (Min. 22-Gauge) Concrete Deck SecurShield HD Ratings - Recover Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR X24A0T VersiGard EPDM Codes Page 28 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Min. 1-1/2" VersiCore MP-H Polyiso Loose laid 1/2" SecurShield HD Plus 8 (4 sq. ft)1-90 325739-0-0 (90-8-30A)341318-0-0 325972-0-0 (90-8-30A)341325-0-0 Min. 1-1/2" VersiCore MP-H Polyiso Loose laid 1/2" SecurShield HD Plus 18 (1.8 sq. ft)1-120 325772-0-0 (90-8-30A) 325981-0-0 (90-8-30A) 325983-0-0 (90-8-30A)- Min. 1-1/2" VersiCore MP-H Polyiso Loose laid 1/2" SecurShield HD Plus 24 (1.33 sq. ft)1-150 374515-0-0 --- Min. 1-1/2" VersiCore MP-H Polyiso Loose laid 1/2" SecurShield HD Plus 24 (1.33 sq. ft.)1-165 325920-0-0 (90-8-30A) 325984-0-0 (90-8-30A) 325985-0-0 (90-8-30A)- Min. 1-1/2" VersiCore MP-H Polyiso or SecurShield Loose laid 1/2" SecurShield HD Plus 24 (1.33 sq. ft)1-225 (42) 325921-0-0 (90-8-30A) 325986-0-0 (90-8-30A) 325987-0-0 (90-8-30A)- Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.)1/2" SecurShield HD Plus 6" ribbions of DASH 1-90 ---- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)1/2" SecurShield HD Plus 6" ribbions of DASH 1-90 409983-0-0 410034-0-0 -- Min. 1-1/2" VersiCore MP-H Polyiso 18 (1.8 sq. ft.)1/2" SecurShield HD Plus 6" ribbions of DASH 1-105 325930-0-0 (90-8-30A) 325991-0-0 (90-8-30A) 325993-0-0 (90-8-30A)- Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.) SecurShield HD Plus over VersiCore MP-H Polyiso 6" ribbions of DASH 1-90 ---- Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.) 1/2" SecurShield HD Plus over Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-90 389422-0-0 404115-0-0 404116-0-0 404125-0-0 Min. 1/2" VersiCore MP-H Polyiso Loose laid 1/2" SecurShield HD Plus 16 (2 sq. ft)1-90 434256-0-0 --- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1/2" SecurShield HD Plus 12" ribbions of DASH 1-315 343383-0-0 344366-0-0 -344369-0-0 Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1/2" SecurShield HD Plus 12" ribbions of DASH 1-225 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA 1/2" SecurShield HD Plus 12" ribbons of Olybond 500 BA 1-240 ---- Min. 1/2" VersiCore MP-H Polyiso Hot Asphalt 1/2" SecurShield HD Plus Hot Asphalt 1-240 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Versico One Step 1/2" SecurShield HD Plus 12" ribbons of Versico One Step 1-255 ---- FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Plus Ratings - New Construction Steel Deck (Min. 22-Gauge) Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) RatingBase Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White RoofNAV Number Concrete Deck X25A0T VersiGard EPDM Codes Page 29 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Plus Ratings - New Construction Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) RatingBase Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White RoofNAV Number X25A0T Min. 1-1/2" VersiCore MP-H Polyiso or SecurShield 1-255 Cav-Grip ---424132-0-0 Min. 1/2" VersiCore MP-H Polyiso or SecurShield 1-150 702 LV 364530-0-0 364572-0-0 364609-0-0 364613-0-0 Min. 1/2" VersiCore MP-H Polyiso or SecurShield 1-90 702 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1/2" SecurShield HD Plus 12" ribbions of DASH 1-150 392983-0-0 392987-0-0 392991-0-0 392998-0-0 Min. 1-1/2" VersiCore MP-H Polyiso Full-Coverage DASH 1/2" SecurShield HD Plus Full-Coverage DASH 1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA 1/2" SecurShield HD Plus 12" ribbons of Olybond 500 BA 1-90 ---- FM Approved Loose laid 1/2" SecurShield HD Plus 8 (4 sq. ft)1-90 ---- --1/2" SecurShield HD Plus 8 (4 sq. ft)1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 4" ribbions of DASH 1/2" SecurShield HD Plus 4" ribbions of DASH 1-135 ---- --1/2" SecurShield HD Plus 4" ribbions of DASH 1-135 ---- Min. 1/2" VersiCore MP-H Polyiso 4" ribbions of DASH 1/2" SecurShield HD Plus 4" ribbions of DASH 1-135 ---- --1/2" SecurShield HD Plus 4" ribbions of DASH 1-135 ---- << TABLE OF CONTENTS Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer Gypsum Deck Tear-Off 12" ribbions of DASH 1/2" SecurShield HD Plus 12" ribbions of DASH VersiGard EPDM Codes Page 30 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: --1/2" SecurShield HD Plus 8 (4 sq. ft)1-90 325757-0-0 325976-0-0 325979-0-0 (90-8-30A)- --1/2" SecurShield HD Plus 6" ribbions of DASH 1-90 --- --1/2" SecurShield HD Plus 4" ribbions of DASH 1-150 ---- --1/2" SecurShield HD Plus 18 (1.78 sq. ft.)1-120 392435-0-0 394207-0-0 394208-0-0 394209-0-0 --1/2" SecurShield HD Plus 24 (1.33 sq. ft.)1-165 394216-0-0 394217-0-0 394218-0-0 394219-0-0 Min. 1/2" VersiCore MP-H Polyiso 6" ribbions of DASH 1/2" SecurShield HD Plus 6" ribbions of DASH 1-150 ---- 1/2" SecurShield HD Plus 6" ribbions of DASH 1-150 ---- Min. 1-1/2" VersiCore MP-H Polyiso Full-Coverage DASH 1/2" SecurShield HD Plus Full-Coverage DASH 1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA 1/2" SecurShield HD Plus 12" ribbons of Olybond 500 BA 1-90 ---- << TABLE OF CONTENTS VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Steel Deck (Min. 22-Gauge) Concrete Deck SecurShield HD Plus Ratings - Recover FM Approvals Design "A" Adhered Roofing Systems Gypsum Deck Tear-Off Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White X26A0T VersiGard EPDM Codes Page 31 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Min. 1-1/2" VersiCore MP-H Polyiso 16 (2 sq. ft)--1-90 400122-0-0 4069-0-0 4069-0-0 400111-0-0 Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)--1-90 4089-0-0 (90-8-30A)384640-0-0 384641-0-0 - Min. 2" VersiCore MP-H Polyiso 20 (1.6 sq. ft)--1-150 384670-0-0 384671-0-0 384672-0-0 384674-0-0 Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.)Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-90 437159-0-0 437161-0-0 -437162-0-0 Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)Min. 2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-90 344604-0-0 344603-0-0 187049-0-0 187056-0-0 (90-8-30A) Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.)Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-90 ---- Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.)Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-105 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH --1-315 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA --1-315 269891-0-0 (90-8-30A) 269891-0-0 (90-8-30A)-- Min. 1-1/2" VersiCore MP-H Polyiso Versico One Step --1-465 83581-0-0 (90-8-30A) 83581-0-0 (90-8-30A) 83581-0-0 (90-8-30A)- Min. 1" VersiCore MP-H Polyiso Hot Asphalt --1-300 240000-0-0 (90-8-30A) 240000-0-0 (90-8-30A) 240000-0-0 (90-8-30A) 241715-0-0 (90-8-30A) 1-255 Cav-Grip ---- 1-195 702 LV ---- 1-90 702 343380-0-0 (all 3 primers listed above) 343380-0-0 (all 3 primers listed above) 343380-0-0 (all 3 primers listed above) 343381-0-0 (all 3 primers listed above) Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH -- VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Steel Deck (Min. 22-Gauge) Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Concrete Deck FM Approvals Design "A" Adhered Roofing Systems VersiCore MP-H Polyiso Ratings - New Construction Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White VersiGard EPDM Codes Page 32 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number FM Approvals Design "A" Adhered Roofing Systems VersiCore MP-H Polyiso Ratings - New Construction Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-330 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH --1-90 394469-0-0 394469-0-0 394469-0-0 394470-0-0 Min. 1-1/2" VersiCore MP-H Polyiso 16 (2 sq. ft)--1-90 7451-0-0 (90-8-30A) 7451-0-0 (90-8-30A) 7451-0-0 (90-8-30A) 7418-0-0 (90-8-30A) Min. 1" VersiCore MP-H Polyiso Full-Coverage DASH --1-90 193358-0-0 (90-8-30A) 1933858-0-0 (90-8-30A) 1933858-0-0 (90-8-30A) 193373-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Versico One Step Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Versico One Step 1-90 83278-0-0 (90-8-30A) 83278-0-0 (90-8-30A) 83278-0-0 (90-8-30A) 97896-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA --1-240 193356-0-0 193356-0-0 193356-0-0 97401-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 16 (2 sq. ft)--1-90 ---- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)--1-90 ---- Min. 2" VersiCore MP-H Polyiso 20 (1.6 sq. ft)--1-150 ---- Min. 1" VersiCore MP-H Polyiso 4" ribbions of DASH --1-135 ---- Min. 1/2" VersiCore MP-H Polyiso 4" ribbions of DASH --1-135 ---- << TABLE OF CONTENTS Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer Gypsum Deck Tear-Off (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) VersiGard EPDM Codes Page 33 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Min. 1" VersiCore MP-H Polyiso 20 (1.6 sq. ft)--1-90 164635-0-0 164635-0-0 164635-0-0 164639-0-0 (90-8-30A) 1/2" VersiCore MP-H Polyiso Full-Coverage DASH --1-150 417298-0-0 417301-0-0 417305-0-0 417311-0-0 Min. 1" InsulBase Polyiso 6" ribbons of FAST --1-90 437208-0-0 --- Min. 1" InsulBase Polyiso 12" ribbons of FAST --1-90 193356-0-0 193356-0-0 193356-0-0 - Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA --1-90 278907-0-0 (90-8-30A) 278907-0-0 (90-8-30A)-- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH --1-90 445220-0-0 --- Min. 1-1/2" VersiCore MP-H Polyiso 16 (2 sq. ft)--1-90 83131-0-0 (90-8-30A) 83131-0-0 (90-8-30A) 9519-0-0 (90-8-30A) 97712-0-0 (90-8-30A) Min. 1/2" VersiCore MP-H Polyiso Full-Coverage DASH --1-90 144196-0-0 144196-0-0 144196-0-0 - 1" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA --1-90 ---- FM Approvals Design "A" Adhered Roofing Systems VersiCore MP-H Polyiso Ratings - Recover RoofNAV Number Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White << TABLE OF CONTENTS Steel Deck (Min. 22-Gauge) Concrete Deck Gypsum Deck Tear-Off VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" VersiGard EPDM Codes Page 34 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Min. 1-1/2" SecurShield or 2" SecurShield HD Composite 16 (2 sq. ft)--1-90 400122-0-0 400122-0-0 400122-0-0 400111-0-0 Min. 2" SecurShield or SecurShield HD Composite 8 (4 sq. ft)--1-90 4089-0-0 (90-8-30A) SecuShield HD Comp. Only 4089-0-0 (90-8-30A) SecuShield HD Comp. Only 4089-0-0 (90-8-30A) SecuShield HD Comp. Only - Min. 2" SecurShield 32 (1 sq. ft.)--1-225 (42) 399359-0-0 245201-0-0 (90-8-30A) 245502-0-0 (90-8-30A) SecurShield Only 245503-0-0 (90-8-30A) SecurShield Only Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.)Min. 1-1/2" SecurShield or SecurShield HD Composite 12" ribbions of DASH 1-90 ---- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)Min. 2" SecurShield or SecurShield HD Composite 12" ribbions of DASH 1-90 344604-0-0 344603-0-0 -- Min. 1/2" DensDeck Prime 16 (2 sq. ft.)Min. 1-1/2" SecurShield or SecurShield HD Composite 12" ribbions of DASH 1-90 252110-0-0 (90-8-30A) SecurShield Only - 252110-0-0 (90-8-30A) SecurShield Only - Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.)Min. 1/2" SecurShield or SecurShield HD Composite 12" ribbions of DASH 1-90 296822-0-0 (90-8-30A)400818-0-0 296822-0-0 (90-8-30A)- Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.)Min. 2" SecurShield HD Composite 12" ribbions of DASH 1-90 400791-0-0 --400790-0-0 Min. 1-1/2" SecurShield or SecurShield HD Composite 12" ribbons of Olybond 500 BA --1-300 222685-0-0 (90-8-30A) SecurShield Only - 222685-0-0 (90-8-30A) SecurShield Only 222686-0-0 (90-8-30A) SecurShield Only Min. 1/2" SecurShield or Secur Shield HD Composite Hot Asphalt --1-300 ---- Min. 2" SecurShield or SecurShield HD Composite 32 (1 sq. ft.)--1-255 430148-0-0 --- Min. 2" SecurShield or SecurShield HD Composite 20 (1.6 sq. ft.)--1-150 430147-0-0 --- Min. 1-1/2" VersiCore MP-H Polyiso -Min. 2" SecurShield HD Composite 16 (2 sq. ft)1-120 ---349806-0-0 Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 2" SecurShield HD Composite 12" ribbions of DASH 1-315 399892-0-0 --- 1-255 Cav-Grip 394769-0-0 395863-0-0 395866-0-0 395870-0-0 1-195 702 LV 394768-0-0 395862-0-0 395865-0-0 395869-0-0 Steel Deck (Min. 22-Gauge) Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard WhiteBase Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) FM Approvals Design "A" Adhered Roofing Systems SecurShield and SecurShield HD Composite Ratings - New Construction RoofNAV Number Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 12" ribbions of DASH Min. 2" SecurShield HD Composite Concrete Deck VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RatingTop Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) X29A0T VersiGard EPDM Codes Page 35 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard WhiteBase Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) FM Approvals Design "A" Adhered Roofing Systems SecurShield and SecurShield HD Composite Ratings - New Construction RoofNAV Number VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RatingTop Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) X29A0T 1-135 702 394767-0-0 395861-0-0 395864-0-0 395868-0-0 Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1-1/2" SecurShield or SecurShield HD Composite 12" ribbions of DASH 1-150 ---- Min. 2" SecurShield 12" ribbions of DASH --1-195 392301-0-0 --- Min. 1-1/2" SecurShield or SecurShield HD Composite 16 (2 sq. ft)--1-90 ---- Min. 1-1/2" SecurShield or SecurShield HD Composite Full-Coverage DASH --1-90 ---- Min. 1-1/2" SecurShield or SecurShield HD Composite 12" ribbons of Olybond 500 BA --1-90 ---- Min. 1-1/2" SecurShield or SecurShield HD Composite 16 (2 sq. ft)--1-75 ---- Min. 2" SecurShield or SecurShield HD Composite 8 (4 sq. ft)--1-90 ---- Min. 2" SecurShield or SecurShield HD Composite 20 (1.6 sq. ft.)--1-150 ---- Min. 2" SecurShield or SecurShield HD Composite 32 (1 sq. ft.)--1-225 ---- Min. 1-1/2" SecurShield or SecurShield HD Composite 4" ribbions of DASH --1-135 ---- Min. 1/2" SecurShield or SecurShield HD Composite 4" ribbions of DASH --1-135 ---- Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer << TABLE OF CONTENTS Cellular Lightweight Insulating Concrete Over Concrete Decking (Celcore) Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) Gypsum Deck Tear-Off VersiGard EPDM Codes Page 36 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: 2" SecurShield 20 (1.6 sq. ft)--1-150 325737-0-0 (90-8-30A)--- 1" SecurShield 16 (2 sq. ft)--1-90 400222-0-0 400222-0-0 400222-0-0 - 1" SecurShield Full-Coverage DASH --1-150 --417309-0-0 - Min. 1/2" SecurShield 12" ribbions of DASH --1-90 ---- 1" SecurShield 20 (1.6 sq. ft)--1-90 ---- 1" SecurShield Full-Coverage DASH --1-90 ---- 1" SecurShield 12" ribbons of Olybond 500 BA --1-90 ---- FM Approvals Design "A" Adhered Roofing Systems SecurShield Ratings - Recover Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White << TABLE OF CONTENTS Gypsum Deck Tear-Off VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Steel Deck (Min. 22-Gauge) Concrete Deck X30A0T VersiGard EPDM Codes Page 37 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approved Loose laid Min. 1/4" Securock 12 (2.66 sq. ft)1-75 ---- FM Approved Loose laid Min. 1/4" Securock 16 (2 sq. ft) SecurFAST Plates 1-90 212270-0-0 (90-8-30A) 270074-0-0 (90-8-30A) 270076-0-0 (90-8-30A) 270077-0-0 (90-8-30A) FM Approved Loose laid Min. 1/4" Securock 10 (3.2 sq. ft)1-90 -405772-0-0 405773-0-0 405774-0-0 FM Approved Loose laid Min. 1/2" Securock 10 (3.2 sq. ft)1-90 302948-0-0 302946-0-0 302949-0-0 302947-0-0 FM Approved Loose laid Min. 1/2" Securock 8 (4 sq. ft) SecurFAST Plates 1-90 319024-0-0 --- FM Approved Loose laid Min. 1/2" Securock 8 (4 sq. ft) SecurFAST Plates 1-90 ---- FM Approved Loose laid Min. 5/8" Securock 8 (4 sq. ft)1-90 ---- FM Approved Loose laid Min. 5/8" Securock 6 (5.33 sq. ft) SecurFAST Plates 1-90 ---- FM Approved Loose laid Min. 1/2" Securock 20 (1.6 sq. ft)1-150 224151-0-0 (90-8-30A) 225287-0-0 (90-8-30A) 225291-0-0 (90-8-30A) 225294-0-0 (90-8-30A) FM Approved Loose laid Min. 1/2" Securock 32 (1 sq. ft)1-255 ---- Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.)Min. 1/4" Securock 12" ribbions of DASH 1-90 386968-0-0 --- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)Min. 1/2" Securock 12" ribbions of DASH 1-90 -187061-0-0 (90-8-30A)-388301-0-0 Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.) Min. 1/4" Securock over Min. 2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-90 ---- Min. 1/2" VersiCore MP-H Polyiso 16 (2 sq. ft.) Min. 1/2" Securock over Min. 1-1/2" VersiCore MP- H Polyiso 12" ribbions of DASH 1-90 323293-0-0 323293-0-0 323293-0-0 - Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)Min. 1/2" Securock 12" ribbions of DASH 1-90 403959-0-0 -403959-0-0 - Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/4" Securock 12" ribbions of DASH 1-315 307927-0-0 (90-8-30A) 304589-0-0 (90-8-30A) 307963-0-0 (90-8-30A)- FM Approvals Design "A" Adhered Roofing Systems Securock Ratings - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Steel Deck (Min. 22-Gauge) Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FRTop Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard White Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Concrete Deck Base Insulation Layer (Max. thickness 36") X31A0T VersiGard EPDM Codes Page 38 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approvals Design "A" Adhered Roofing Systems Securock Ratings - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FRTop Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard WhiteBase Insulation Layer (Max. thickness 36") X31A0T Min. 1" Insulfoam EPS 12" ribbions of DASH Min. 1/4" Securock 6" ribbions of DASH 1-255 Cav-Grip 396669-0-0 (LVOC) 396689-0-0 (LVOC) 396697-0-0 (LVOC) 396708-0-0 (LVOC) Min. 1" Insulfoam EPS 6" ribbions of DASH Min. 1/4" Securock 6" ribbions of DASH 1-150 Cav-Grip -396684-0-0 (90-8-30A)-- 1-195 702 LV --396702-0-0 (LVOC)- 1-90 702 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/4" Securock 12" ribbions of DASH 1-150 392916-0-0 --392919-0-0 Min. 1-1/2" VersiCore MP-H Polyiso Full-Coverage DASH Min. 1/4" Securock Full-Coverage DASH 1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA Min. 1/4" Securock 12" ribbons of Olybond 500 BA 1-90 ---- FM Approved Loose laid Min. 1/4" Securock 12 (2.67 sq. ft)1-75 ---- FM Approved Loose laid Min. 1/2" Securock 10 (3.2 sq. ft)1-90 ---- FM Approved Loose laid Min. 5/8" Securock 8 (4 sq. ft)1-90 ---- FM Approved Loose laid Min. 1/2" Securock 20 (1.6 sq. ft)1-150 ---- FM Approved Loose laid Min. 1/2" Securock 32 (1 sq. ft)1-225 ---- Min. 1-1/2" VersiCore MP-H Polyiso 4" ribbions of DASH Min. 1/2 "Securock 4" ribbions of DASH 1-135 ---- Min. 1/2" VersiCore MP-H Polyiso 4" ribbions of DASH Min. 1/2 "Securock 4" ribbions of DASH 1-135 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA Min. 1/2 "Securock 12" ribbons of Olybond 500 BA 1-240 ---- << TABLE OF CONTENTS Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer Gypsum Deck Tear-Off 12" ribbions of DASH Min. 1/4" Securock12" ribbions of DASHMin. 1-1/2" VersiCore MP-H Polyiso Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer VersiGard EPDM Codes Page 39 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Max. 1" VersiCore MP-H Polyiso Loose laid Min. 1/2" Securock 10 (3.2 sq. ft)1-90 437209-0-0 --- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/4" Securock 12" ribbions of DASH 1-90 ---- DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced Steel Deck VersiGard Reinforced VersiGard Reinforced FR << TABLE OF CONTENTS FM Approvals Design "A" Adhered Roofing Systems Securock Ratings - Recover VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Concrete Deck Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating RoofNAV Number VersiGard White Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) X32A0T VersiGard EPDM Codes Page 40 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approved Loose laid Min. 1/4" DensDeck Prime 12 (2.67 sq. ft)1-90 -83097-0-0 (90-8-30A) 134403-0-0 (90-8-30A) 97691-0-0 (90-8-30A) FM Approved Loose laid Min. 1/2" DensDeck Prime 10 (3.2 sq. ft)1-90 350409-0-0 350408-0-0 350411-0-0 350410-0-0 Min. 1" VersiCore MP-H Polyiso Loose Laid Min. 1/2" DensDeck Prime 20 (1.6 sq. ft)1-105 224154-0-0 (90-8-30A)224152-0-0 224156-0-0 224159-0-0 FM Approved Loose laid Min. 5/8" DensDeck Prime 8 (4 sq. ft)1-90 85854-0-0 (90-8-30A) 83095-0-0 (90-8-30A) 134402-0-0 (90-8-30A) 97689-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/2" DensDeck Prime 8 (4 sq.ft)1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/4" DensDeck Prime 18 (1.8 sq. ft)1-105 382307-0-0 --- Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/2" DensDeck Prime 18 (1.8 sq. ft)1-135 383697-0-0 --- Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/2" DensDeck Prime 20 (1.6 sq. ft)1-150 383707-0-0 --394644-0-0 Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/2" DensDeck Prime 32 (1 sq. ft)1-165 424136-0-0 --- Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/2" DensDeck Prime 32 (1 sq. ft)1-180 (41)384589-0-0 --- Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/2" DensDeck Prime 32 (1 sq. ft)1-255 (42)387896-0-0 --394645-0-0 Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.)Min. 1/4" DensDeck Prime 12" ribbions of DASH 1-90 ---- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)Min. 1/4" DensDeck Prime 12" ribbions of DASH 1-90 428854-0-0 187061-0-0 (90-8-30A)428855-0-0 428856-0-0 Min. 1/2" DensDeck Prime 16 (2 sq. ft.) Min. 1/4" DensDeck Prime over 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-90 303439-0-0 303438-0-0 (90-8-30A) 303440-0-0 (90-8-30A) 303441-0-0 (90-8-30A) Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.) Min. 1/4" DensDeck Prime over 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 1-90 323293-0-0 323293-0-0 323293-0-0 - Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/4" DensDeck Prime 12" ribbions of DASH 1-465 160628-0-0 (90-8-30A) 160610-0-0 (90-8-30A) 160631-0-0 (90-8-30A) 160633-0-0 (90-8- 30A) FM Approvals Design "A" Adhered Roofing Systems DensDeck Prime Ratings - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Steel Deck (Min. 22-Gauge) Concrete Deck Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FRTop Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard White X33A0T VersiGard EPDM Codes Page 41 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approvals Design "A" Adhered Roofing Systems DensDeck Prime Ratings - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FRTop Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard White X33A0T --Min. 1/4" DensDeck Prime 12" ribbons of Olybond 500 BA 1-465 ---- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Versico One Step Min. 1/4" DensDeck Prime 12" ribbons of Versico One Step 1-465 86769-0-0 (90-8-30A) 83587-0-0 (90-8-30A) 86769-0-0 (90-8-30A) 98207-0-0 (90-8-30A) Min. 1/2" VersiCore MP-H Polyiso Hot Asphalt Min. 1/4" DensDeck Prime Hot Asphalt 1-300 ---- 1-255 Cav-Grip 274598-0-0 (90-8-30A) 274610-0-0 (90-8-30A) 274606-0-0 (90-8-30A)- 1-195 702 LV ---- 1-90 702 274603-0-0 (90-8-30A) 274611-0-0 (90-8-30A)-- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of FAST Min. 1/2" DensDeck Prime 12" ribbons of FAST 1-225 Cav-Grip 438679-0-0 438685-0-0 -- Min. 1-1/2" VersiCore MP-H Polyiso 6" ribbions of DASH Min. 1/2" DensDeck Prime 12" ribbions of DASH 1-225 Cav-Grip ---424135-0-0 Min. 1" Insulfoam EPS 6" ribbions of DASH Min. 1/4" DensDeck Prime 6" ribbions of DASH 1-165 395957-0-0 395960-0-0 395961-0-0 395962-0-0 Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/4" DensDeck Prime 12" ribbions of DASH 1-330 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/4" DensDeck Prime 12" ribbions of DASH 1-105 ---392993-0-0 Min. 1-1/2" VersiCore MP-H Polyiso Full-Coverage DASH Min. 1/4" DensDeck Prime Full-Coverage DASH 1-90 163461-0-0 (90-8-30A) 157782-0-0 (90-8-30A)-157783-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Versico One Step Min. 1/4" DensDeck Prime 12" ribbons of Versico One Step 1-90 85902-0-0 (90-8-30A) 83272-0-0 (90-8-30A) 134289-0-0 (90-8-30A) 97820-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA Min. 1/4" DensDeck Prime 12" ribbons of Olybond 500 BA 1-90 84593-0-0 (90-8-30A) 82831-0-0 (90-8-30A) 134241-0-0 (90-8-30A) 98382-0-0 (90-8-30A) FM Approved Loose laid Min. 1/4" DensDeck Prime 12 (2.67 sq. ft)1-90 ---- FM Approved Loose laid Min. 1/2" DensDeck Prime 10 (3.2 sq. ft)1-90 ---- FM Approved Loose laid Min. 5/8" DensDeck Prime 8 (4 sq. ft)1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 4" ribbions of DASH Min. 1/2" DensDeck Prime 4" ribbions of DASH 1-135 ---- Min. 1/2" VersiCore MP-H Polyiso 4" ribbions of DASH Min. 1/4" DensDeck Prime 4" ribbions of DASH 1-135 ---- Min. 1" VersiCore MP-H Polyiso Full-Coverage DASH Min. 1/4" DensDeck Prime Full-Coverage DASH Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer Gypsum Deck Tear-Off VersiGard EPDM Codes Page 42 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approvals Design "A" Adhered Roofing Systems DensDeck Prime Ratings - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FRTop Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard White X33A0T << TABLE OF CONTENTS VersiGard EPDM Codes Page 43 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: --Min. 1/2" DensDeck Prime 10 (3.2 sq. ft)1-90 ---428852-0-0 Min. 1" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/4" DensDeck Prime 12" ribbions of DASH 1-75 ---173671-0-0 (90-8-30A) FM Approvals Design "A" Adhered Roofing Systems DensDeck Prime Ratings - Recover Concrete Deck VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White << TABLE OF CONTENTS X34A0T VersiGard EPDM Codes Page 44 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Min. 1-1/2" VersiCore MP-H Polyiso Loose laid Min. 1/2" HP Recovery Board 16 (2 sq. ft)1-90 270071-0-0 (x-23 Only) 270070-0-0 (x-23 Only) 270072-0-0 (x-23 Only) 270073-0-0 (x-23 Only) Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.)Min. 1/2" HP Recovery Board 6" ribbions of DASH 1-90 --- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)1/2"-1" HP Recovery Board 12" ribbions of DASH 1-90 187065-0-0 (90-8-30A) 187061-0-0 (90-8-30A) 187071-0-0 (90-8-30A) 187105-0-0 (90-8-30A) Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.)Min. 1/2" HP Recovery Board 6" ribbions of DASH 1-90 ---- Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.) Min. 1/2" HP Recovery Board over Min. 1-1/2" VersiCore MP-H Polyiso 6" ribbions of DASH 1-90 387389-0-0 387390-0-0 323293-0-0 - Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/2" HP Recovery Board 12" ribbions of DASH 1-315 -160648-0-0 (90-8-30A) 160979-0-0 (90-8-30A) 160981-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA Min. 1/2" HP Recovery Board 12" ribbons of Olybond 500 BA 1-240 229682-0-0 (90-8-30A) 229665-0-0 (90-8-30A) 229684-0-0 (90-8-30A) 229685-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Versico One Step Min. 1/2" HP Recovery Board 12" ribbons of Versico One Step 1-255 86730-0-0 (90-8-30A) 83491-0-0 (90-8-30A) 134301-0-0 (90-8-30A) 97965-0-0 (90-8-30A) Min. 1" VersiCore MP-H Polyiso Hot Asphalt Min. 1/2" HP Recovery Board Hot Asphalt 1-300 ---- 1-255 Cav-Grip 392406-0-0 394204-0-0 (90-8-30A) 394205-0-0 (90-8-30A) 394206-0-0 (90-8-30A) 1-195 702 LV ---- 1-90 702 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/2" HP Recovery Board 12" ribbions of DASH 1-330 ---- Min. 1/2" VersiCore MP-H Polyiso or Min. 1" Insulfoam 12" ribbions of DASH Min. 1/2" HP Recovery Board 12" ribbions of DASH 1-255 394582-0-0 394583-0-0 (90-8-30A) 394584-0-0 (90-8-30A)394585-0-0 Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/2" HP Recovery Board 12" ribbions of DASH VersiGard FR Nonreinforced VersiGard Reinforced Concrete Deck Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer FM Approvals Design "A" Adhered Roofing Systems Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer HP Recovery Board Ratings - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Steel Deck (Min. 22-Gauge) Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard Reinforced FR VersiGard White X35A0T VersiGard EPDM Codes Page 45 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard FR Nonreinforced VersiGard Reinforced FM Approvals Design "A" Adhered Roofing Systems HP Recovery Board Ratings - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" RoofNAV Number Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard Reinforced FR VersiGard White X35A0T Min. 1-1/2" VersiCore MP-H Polyiso Full-Coverage DASH Min. 1/2" HP Recovery Board Full-Coverage DASH 1-90 163461-0-0 (90-8-30A) 157782-0-0 (90-8-30A)-157783-0-0 (90-8-30A) Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA Min. 1/2" HP Recovery Board 12" ribbons of Olybond 500 BA 1-90 84593-0-0 (90-8-30A) 82831-0-0 (90-8-30A) 134241-0-0 (90-8-30A) 98382-0-0 (90-8-30A) FM Approved Loose laid Min. 1/2" HP Recovery Board 16 (2 sq. ft)1-90 ---- Min. 1-1/2" VersiCore MP-H Polyiso 4" ribbons DASH Min. 1/2" HP Recovery Board 4" ribbions of DASH 1-90 ---- Min. 1" VersiCore MP-H Polyiso 12" ribbons DASH Min. 1/2" HP Recovery Board 12" ribbons DASH 1-135 309956-0-50914 309932-0-50914 309960-0-50914 309964-0-50914 << TABLE OF CONTENTS (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking Gypsum Deck Tear-Off Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) VersiGard EPDM Codes Page 46 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH Min. 1/2" HP Recovery Board 12" ribbions of DASH 1-90 ---- FM Approvals Design "A" Adhered Roofing Systems VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" HP Recovery Board Ratings - Recover Concrete Deck Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White X36A0T VersiGard EPDM Codes Page 47 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approved Loose laid 7/16" OSB 17 (1.8 sq. ft)1-150 ---- FM Approved Loose laid 7/16" OSB 32 (1 sq. ft)1-210 ---- Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.)7/16" OSB over VersiCore MP-H Polyiso 4" ribbions of DASH 1-90 ---- Min. 1/2" VersiCore MP-H Polyiso Loose laid 7/16" OSB 32 (1 sq. ft)1-210 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 7/16" OSB 12" ribbions of DASH 1-315 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA 7/16" OSB 12" ribbons of Olybond 500 BA 1-240 ---- 1-255 Cav-Grip ---- 1-195 702 LV ---- 1-90 702 ---- Min. 1/2" DensDeck Prime or Securock 16 (2 sq. ft.)7/16" OSB over VersiCore MP-H Polyiso 6" ribbions of DASH 1-90 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 7/16" OSB 12" ribbions of DASH 1-330 ---- Min. 1-1/2" VersiCore MP-H Polyiso Full-Coverage DASH 7/16" OSB Full-Coverage DASH 1-90 --- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA 7/16" OSB 12" ribbons of Olybond 500 BA 1-90 --- FM Approved Loose laid 7/16" OSB 17 (1.9 sq. ft)1-105 ---- Min. 1/2" VersiCore MP-H Polyiso 4" ribbions of DASH 7/16" OSB 4" ribbions of DASH 1-135 ---- VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" FM Approvals Design "A" Adhered Roofing Systems DURAFACR Ratings - New Construction RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) Steel Deck (Min. 22-Gauge) Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Concrete Deck Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White << TABLE OF CONTENTS (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking Gypsum Deck Tear-Off Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer Steel Deck (Min. 22 Gauge)/VapAir Seal 725TR with Cav-Grip Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/Cut-Back Asphalt Primer Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer (Celcore) Cellular Lightweight Insulating Concrete Over Steel Decking Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 7/16" OSB 12" ribbions of DASH X37A0T VersiGard EPDM Codes Page 48 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approved Loose laid 7/16" OSB 17 (1.8 sq. ft)1-105 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbions of DASH 7/16" OSB 12" ribbions of DASH 1-90 ---- VersiGard Reinforced FR VersiGard White << TABLE OF CONTENTS FM Approvals Design "A" Adhered Roofing Systems RoofNAV Number Steel Deck (Min. 22-Gauge) Concrete Deck VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating DURAFACR Ratings - Recover Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) VersiGard FR Nonreinforced VersiGard Reinforced X38A0T VersiGard EPDM Codes Page 49 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approved Loose laid Min. 1/4" Securock 12 (2.66 sq. ft)1-75 ---- FM Approved Loose laid Min. 1/4" Securock 16 (2 sq. ft) SecurFAST Plates 1-90 ---- FM Approved Loose laid Min. 1/4" Securock 10 (3.2 sq. ft)1-90 ---- FM Approved Loose laid Min. 1/2" Securock 10 (3.2 sq. ft)1-90 ---- FM Approved Loose laid Min. 1/2" Securock 8 (4 sq. ft) SecurFAST Plates 1-90 ---- FM Approved Loose laid Min. 5/8" Securock 8 (4 sq. ft)1-90 ---- FM Approved Loose laid Min. 5/8" Securock 6 (5.33 sq. ft) SecurFAST Plates 1-90 ---- FM Approved Loose laid Min. 1/2" Securock 20 (1.6 sq. ft)1-150 ---- FM Approved Loose laid Min. 1/2" Securock 32 (1 sq. ft)1-255 ---- Min. 1-1/2" VersiCore MP-H Polyiso 10 (3.2 sq. ft.)Min. 1/4" Securock 12" ribbons of DASH 1-90 ---- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)Min. 1/2" Securock 12" ribbons of DASH 1-90 ---- Min. 1/2" DensDeck Prime or 5/8" Securock 16 (2 sq. ft.)Min. 1/4" Securock over Min. 2" InsulBase Polyiso 12" ribbons of DASH 1-90 ---- Min. 1/2" VersiCore MP-H Polyiso 16 (2 sq. ft.) Min. 1/2" Securock over Min. 1-1/2" InsulBase Polyiso 12" ribbons of DASH 1-90 ---- Min. 2" VersiCore MP-H Polyiso 8 (4 sq. ft)Min. 1/2" Securock 12" ribbons of DASH 1-90 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of DASH Min. 1/4" Securock 12" ribbons of DASH 1-315 ---- Min. 1" Insulfoam EPS 12" ribbons of DASH Min. 1/4" Securock 6" ribbons of DASH 1-255 Cav-Grip ---- Min. 1" Insulfoam EPS 6" ribbons of DASH Min. 1/4" Securock 6" ribbons of DASH 1-150 Cav-Grip ---- 1-195 702 LV ---- 1-90 702 ---- Min. 1/2" InsulBase Polyiso 12" ribbons of DASH Min. 1/4" Securock 12" ribbons of DASH 1-150 ---- Min. 1-1/2" InsulBase Polyiso Full-Coverage DASH Min. 1/4" Securock Full-Coverage DASH 1-90 ---- Min. 1-1/2" InsulBase Polyiso 12" ribbons of Olybond 500 BA Min. 1/4" Securock 12" ribbons of Olybond 500 BA 1-90 ---- FM Approved Loose laid Min. 1/4" Securock 12 (2.67 sq. ft)1-75 ---- FM Approved Loose laid Min. 1/2" Securock 10 (3.2 sq. ft)1-90 ---- FM Approved Loose laid Min. 5/8" Securock 8 (4 sq. ft)1-90 ---- FM Approved Loose laid Min. 1/2" Securock 20 (1.6 sq. ft)1-150 ---- FM Approved Loose laid Min. 1/2" Securock 32 (1 sq. ft)1-225 ---- Steel Deck (Min. 22-Gauge) FM Approvals DuraStorm VSH - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White RoofNAV Number Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer Concrete Deck Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer Min. 1-1/2" InsulBase Polyiso 12" ribbons of DASH Min. 1/4" Securock 12" ribbons of DASH Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer Gypsum Deck Tear-Off Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge) VersiGard EPDM Codes Page 50 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: FM Approvals DuraStorm VSH - New Construction VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White RoofNAV Number Min. 1-1/2" VersiCore MP-H Polyiso 4" ribbons of DASH Min. 1/2 "Securock 4" ribbons of DASH 1-135 ---- Min. 1-1/2" VersiCore MP-H Polyiso 4" ribbons of DASH Min. 1/2 "Securock 4" ribbons of DASH 1-135 ---- Min. 1-1/2" VersiCore MP-H Polyiso 12" ribbons of Olybond 500 BA Min. 1/2 "Securock 12" ribbons of Olybond 500 BA 1-240 ---- (Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking << TABLE OF CONTENTS VersiGard EPDM Codes Page 51 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Max. 1" VersiCore MP-H Polyiso Loose laid Min. 1/2" Securock 10 (3.2 sq. ft)1-90 ---- Min. 1/2" VersiCore MP-H Polyiso 12" ribbons of DASH Min. 1/4" Securock 12" ribbons of DASH 1-90 ---- FM Approvals DuraStorm VSH Ratings - Recover VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) Concrete Deck << TABLE OF CONTENTS VersiGard FR Nonreinforced VersiGard Reinforced VersiGard Reinforced FR VersiGard White RoofNAV Number Steel Deck Base Insulation Layer (Max. thickness 36") Base Layer Fastening (mechanically fastened see notes 38, 39 & 40) Top Insulation Layer Top Layer Fastening (mechanically fastened see notes 38, 39 & 40) Rating VersiGard EPDM Codes Page 52 of 57 8/2019 11/27/2019 Membrane Type: Membrane Adhesive: Base and Top Layer Adhesive: Steel Celcore 1-135 ---243813-0-194470 (90-8-30A) Concrete Celcore 1-270 ---- Concrete Elastizell 1-180 173454-0-50936 (90-8-30A) 173568-0-50936 (90-8-30A) 173566-0-50936 (90-8-30A) 192446-0-50936 (90-8-30A) FM Approvals Design "A" Adhered Roofing Systems Lightweight Insulating Concrete - New Construction RoofNAV Number Versico G200SA Substrate Adhesive or EPDM x-23 LVOC Bonding Adhesive (LVOC) VersiGard Reinforced FR VersiGard White VersiGard FR Nonreinforced .045', .060" or .090" VersiGard Reinforced .045", .060", or .075" VersiGard Reinforced FR .045', .060" or .075" VersiGard White .060" or .090" DASH = DASH 100LV, Flexible DASH, DASH Bag in a Box, DASH Dual Cartridge and DASH Dual Tank (DASH Dual Tank can only be used on Steel and Concrete Decking) << TABLE OF CONTENTS Deck Type Lightweight Insulating Concrete Rating VersiGard FR Nonreinforced VersiGard Reinforced X41A0T VersiGard EPDM Codes 53 of 57 8/2019 11/27/2019 Insulation Insulation Fastening Density Polyisocyanurate insulation overlaid with minimum 7/16" thick APA grade non- veneer oriented strand board (OSB). 17 fasteners per 4' X 8' board per Versico Detail A-27-D << TABLE OF CONTENTS 165 psf Uplift Resistance (1-165 Approval Equivalency on 12' X 24' Table) (43)(44) VersiGard Black/VersiGard White Adhered Roofing Systems 1-165 (165 psf) Wind Uplift Equivalency Ratings (over OSB) Membrane Type: VersiGard Black/VersiGard White .060" Non-Reinforced EPDM Membrane VersiGard Reinforced .045", .060" or .075” Reinforced EPDM Membrane Wind uplift testing has been completed in accordance with the FM Approvals 4470 Test Procedure which was witnessed and certified by Architectural Testing, Incorporated, an industry recognized Independent Testing Laboratory. Over a 22-gauge steel roof deck, the following results were obtained. Performance Test Reports are on file and available from Versico. X42A0T VersiGard EPDM Codes 54 of 57 8/2019 11/27/2019 Authority Approval Approved Systems ICC - International Code Council Report ESR 1184 Report ESR-1463 "B" “A” and “MF” SBCCI "B" BOCA "B" NES – National Evaluation Service, Inc."B" “A” and “MF” ICBO "B" “A” and “MF” Evaluation Report Number FL1601 FL16441 2019 Copyright Carlisle Construction Materials Incorporated Versico, a division of Carlisle Construction Materials Incorporated, P. O. Box 1289, Carlisle, PA 17013 The contents of this issue represents the applicable information available at the time of publication. The contents of older issues are no longer accurate due to subsequent changes. These Code Bodies merged to form ICC as of March 2003 Refer to ICC approval NATIONAL, STATE & CITY BUILDING CODE APPROVALS Evaluation Report Use Not for use in High Velocity Hurricane Zone area For use in High Velocity Hurricane Zone area State of Florida Evaluation Report << TABLE OF CONTENTS 1.800.992.7663 Versico and VersiGard are Trademarks of Versico. DensDeck Prime is a Trademark of Georgia-Pacific X43A0T VersiGard EPDM Codes 55 of 57 8/2019 11/27/2019 VersiGard EPDM Reference Notes (Page 1 of 2) 1. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 2. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to table) 3. Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness may be used below the 3” minimum total thickness of SecurShield or SecurShield HD Composite. (return to table) 4. Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness may be used below the 1.9” thickness of SecurShield or SecurShield HD Composite. (return to table) 5. Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness may be used below the 1” thickness of SecurShield CD. (return to table) 6. Any UL Classified Insulation, any combination, any thickness, may be used below the 4-1/2” minimum total thickness. (return to table) 7. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 8. Any thickness of UL Classified Versico Polyisocyanurate Insulation may be used below the 1.9” thickness of SecurShield or SecurShield HD Composite. (return to table) 9. Any UL Classified insulation, any combination, any thickness, may be used below the SecurShield CD. (return to table) 10. For insulation requirements, maximum roof slopes and acceptable roof construction types (new, Tear-off or retrofit), click here. (return to table) 11. Testing conducted on FM approved 22-gauge Grade E steel decking meeting ASTM A653 or A446 Grade 80. (return to table) 12. Please reference ANSI-SPRI WD-1/ASCE 7-10 for non-FM insured projects, click here. (return to table) 13. Steel decking shall be FM approved minimum 22-gauge meeting ASTM designation A611 Grade E or A653 Grade 80. (return to table) 14. Testing conducted on standard FM approved 22-gauge steel decking secured as outlined in the FM Approval Guide and FM Loss Prevention Data Sheet 1-29. (return to table) 15. For FM 1-90 ratings, deck securement requirements are outlined in the FM Approval Guide under the respective deck manufacturer approval listing. (return to table) 16. Refer to the following pages for insulation requirements, maximum roof slopes, approved insulation and acceptable roof construction types (new, Tear-off or retrofit), click here. (return to table) 17. On steel decks, a thermal barrier of FM approved perlite or gypsum board (Type "X" or Type "C") is required under expanded and extruded polystyrene insulations. For specific thermal barrier requirements, consult the respective insulation manufacturer or current published FM Approval Guide. (return to table) 18. On FM approved wood decks, minimum 1/4" thick gypsum board must be installed beneath the insulations listed. Polystyrene insulations must incorporate 1/4" gypsum board in addition to standard thermal barrier requirements. (return to table) 19. Existing roof must be FM Class 1 rated. (return to table) 20. Testing conducted on minimum 22-gauge steel roof deck secured to the structural steel supports having a maximum span of 6' on center. The deck is fastened to the minimum 1/4" thick steel supports with ITW Buildex Traxx/5 fasteners spaced a maximum of 6" on center. Deck side laps are secured with Traxx/1 Fasteners spaced a maximum of 30" on center. (return to table) 21. 1/2" thick HP Recovery Board cannot be installed as a single layer directly over wide rib (type B) or intermediate rib (type F) steel decks. For flute spanability criteria with Polyisocyanurate insulation, contact the respective insulation manufacturer. (return to table) 22. Refer to the following pages for insulation requirements, maximum roof slopes and acceptable roof construction types (new, Tear-off or retrofit), click here. (return to table) 23. Refer to the following pages for insulation requirements, maximum roof slopes, approved insulation and acceptable roof construction types (new, Tear-off or retrofit), click here. (return to table) 24. Ballast to be nominal 1-1/2" diameter, river washed stone at a minimum 10 pounds per square foot. Individual concrete pavers (minimum 18 pounds per square foot) or approved lightweight interlocking pavers (minimum 10 pounds per square foot) may also be used. 1/8" maximum spacing between pavers is permitted. (return to table) 25. Versico HP Protective Mat may be used between the ballast and the membrane without altering the rating. (return to table) 26. Ballast to be nominal 1-1/2" diameter, river washed stone at a minimum 10 pounds per square foot. Individual concrete pavers (minimum 18 pounds per square foot) or approved lightweight interlocking pavers (minimum 10 pounds per square foot) may also be used. 1/8" maximum spacing between pavers is permitted. (return to table) 27. Versico HP Protective Mat must be used between the ballast and the extruded polystyrene insulation. (return to table) 28. Insulation products listed are for use above the EPDM membrane. One layer of any UL classified insulation may be added below the membrane without altering the rating. (return to table) X44A0T VersiGard EPDM Codes 56 of 57 8/2019 11/27/2019 Reference Notes (Page 2 of 2) 29. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 30. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to table) 31. Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness may be used below the 3” minimum total thickness of SecurShield or SecurShield HD Composite. (return to table) 32. Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness may be used below the 1.9” thickness of SecurShield or SecurShield HD Composite. (return to table) 33. Any UL Classified Versico Polyisocyanurate Insulation, any combination, any thickness may be used below the 1” thickness of SecurShield CD. (return to table) 34. Any UL Classified Insulation, any combination, any thickness, may be used below the 4-1/2” minimum total thickness. (return to table) 35. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table) 36. Any thickness of UL Classified Versico Polyisocyanurate Insulation may be used below the 1.9” thickness of SecurShield or SecurShield HD Composite. (return to table) 37. Any UL Classified insulation, any combination, any thickness, may be used below the SecurShield CD. (return to table) 38. Versico HPV fastener/Versico Insulation plate. 39. InsulFAST fastener/Sure-Seal Insulation plate. 40. InsulFAST fastener/SecurFAST Insulation Fastening plate. 41. 80 ksi with one fastener per attachment point. (return to table) 42. 80 ksi with two fasteners per attachment point. (return to table: SecurShield HD Plus, DensDeck Prime or SecurShield) 43. Testing conducted on 22-gauge steel roof deck secured to the strucural steel supports having a maximum span of 6" on center. The deck is fastened to the minimum 1/4" thick steel supports with ITW Buildex Traxx/5 fasteners spaced a maximum of 6" on center. Deck side laps are secured with Traxx/1 Fasteners spaced a maximum of 30" on center. (return to table) 44. Failure occurred upon pressurization at 180 psf. System passed 165 psf resistance cycle. (return to table) << TABLE OF CONTENTS Click on one of the following to return to chart: SecurShield HD, SecurShield HD Plus, VersiCore MP-H Polyiso, SecurShield, SecurShield HD Composite, Securock, DensDeck Prime, DuraFacr or HP Recovery Board VersiGard EPDM Codes 57 of 57 8/2019 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 1/103 UL PRODUCT CATEGORY Roofing Systems See General Information for Roofing Systems VERSICO INC R9853 PO BOX 1289 CARLISLE, PA 17013-6289 USA The following chart represents a cross reference of materials whereby any WeatherBond product may be used as an acceptable alternate to any Versico Product/Classification referenced within. Versico WeatherBond VersiGard EPDM WeatherBond EPDM VersiGard FR EPDM WeatherBond FR EPDM VersiGard White EPDM WeatherBond White EPDM VersiGard Reinforced EPDM WeatherBond Standard Reinforced EPDM VersiGard FR Reinforced EPDM WeatherBond FR Reinforced EPDM VersiGard QA Reinforced EPDM WeatherBond PAS Reinforced EPDM VersiGard QA Non-Reinforced EPDM WeatherBond PAS Non-Reinforced EPDM VersiGard QA White Non-Reinforced EPDM WeatherBond PAS White Non-Reinforced EPDM VersiWeld TPO WeatherBond TPO VersiWeld Plus TPO WeatherBond Plus TPO VersiWeld HS TPO WeatherBond HS TPO VersiWeld HS Plus TPO WeatherBond HS Plus TPO VersiWeld QA TPO WeatherBond PAS TPO VersiFleece TPO 100 WeatherBond TPO Fleece 100 VersiFleece TPO 115 WeatherBond TPO Fleece 115 VersiFleece TPO 135 WeatherBond TPO Fleece 135 VersiFleece AC TPO 120 WeatherBond TPO AC Fleece 120 VersiFleece AC TPO 135 WeatherBond TPO AC Fleece 135 VersiFleece AC TPO 155 WeatherBond TPO AC Fleece 15511/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 2/103 VersiFleece FR TPO WeatherBond TPO FR Fleece VersiFlex PVC WeatherBond PVC VersiFlex KEE HP WeatherBond KEE HP VersiFlex FRS PVC WeatherBond PVC FRS VersiFleece PVC WeatherBond PVC Fleece VersiFleece KEE HP WeatherBond KEE HP Fleece VersiFleece FRS PVC WeatherBond PVC FRS Fleece VersiFleece FRS KEE HP WeatherBond KEE HP FRS Fleece VersiCore MP-H WeatherBond XP VersiCore MP-H NH WeatherBond XP NH Polyiso MP-HF WeatherBond XP-HF SecurShield WeatherBond XFP SecurShield NH WeatherBond XFP NH SecurShield HD WeatherBond XFP HD Cover Board SecurShield HD NH WeatherBond XFP HD NH Cover Board SecurShield HD Plus WeatherBond XFP HD Plus Cover Board SecurShield HD Plus NH WeatherBond XFP HD Plus NH Cover Board SecurShield CD WeatherBond XFP CD SecurShield CD NH WeatherBond XFP CD NH Polyiso MP-HWF WeatherBond XP-WF DuraFaceR WeatherBond XP-NB DuraFaceR NH WeatherBond XP-NB NH SecurShield HD Composite WeatherBond XFP HD Composite SecurShield HD Composite NH WeatherBond XFP HD Composite NH SecurShield HD FR WeatherBond XFP HD FR Recovery Board WeatherBond Recovery Board Cav-Grip 3V Adhesive/Primer WeatherBond Cav-Grip III Adhesive/Primer G200SA Yellow Substrate Adhesive WeatherBond LC-60 Bonding Adhesive VersiWeld TPO Bonding Adhesive WeatherBond TPO Bonding Adhesive DASH Adhesive WeatherBond DASH Adhesive Flexible DASH WeatherBond Flexible DASH DASH 5-Gallon Jug Adhesive WeatherBond DASH 5-Gallon Jug Adhesive 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 3/103 DASH Dual Cartridge Adhesive WeatherBond DASH Dual Cartridge Adhesive DASH Dual Tank Adhesive WeatherBond DASH Dual Tank Adhesive Flexible DASH 5-Gallon Jug Adhesive WeatherBond Flexible DASH 5-Gallon Jug Adhesive Flexible DASH Dual Cartridge Adhesive WeatherBond Flexible DASH Dual Cartridge Adhesive Flexible DASH Dual Tank Adhesive WeatherBond Flexible DASH Dual Tank Adhesive VersiGard Quick Applied Seam Tape WeatherBond Peel & Stick Seam Tape VersiGard White Quick Applied Seam Tape WeatherBond White Peel & Stick Seam Tape G-300 LS Black Lap Sealant WeatherBond Black Lap Sealant G-300 LS White Lap Sealant WeatherBond Black Lap Sealant VersiFlex PVC Rib Profile WeatherBond PVC Rib Profile VersiWeld TPO Rib Profile WeatherBond TPO Rib Profile SINGLE PLY MEMBRANE SYSTEMS Any system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. In the fully adhered and mechanically fastened systems described below, the "VersiGard EPDM" membrane coated with "G-700HC Hysunite Coating" coating at 2/3-gal/100-ft2 and dry silica sand2) may replace the "VersiGard FR EPDM" membrane. When a classification does not require a hypalon or hypalon and sand coating, the classification of any EPDM roof covering system is retained when surfaced with 1 or 2 coats of "G-700HC Hysunite Coating" coating using of a coverage rate of 2/3-gal/100-ft2/coat limited to maximum slope of 3-1/2 in. slope. Unless otherwise indicated, when referring to gypsum board in the following classifications, the following will be referenced: Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard", minimum 1/4- in. thick United States Gypsum Co. "SECUROCK Glass-Mat Roof Board" (Type SGMRX) or "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G), , minimum 0.463-in. thick regular gypsum board (not Classified) weighing a minimum of 184-lbs/100-ft.2 laid with butt joints staggered a minimum of 6-in. from the roof deck butt joints or Georgia Pacific "Sound Deadening" Board, measuring 0.208-in. thick minimum and weighing 109-lbs./100-ft.2 minimum. Minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) is limited to a maximum 3:12 slope when used as a thermal barrier over a combustible roof deck in a system with any UL Classified insulation except polystyrene. Minimum 1/2-in. thick United States Gypsum Co. "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) is limited to a maximum 1:12 slope when used as a thermal barrier over a combustible roof deck in a system without insulation or with any UL Classified polystyrene insulation. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 4/103 Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard", minimum 1/4-in. thick Owens Corning "Strataguard", minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Glass-Mat Roof Board" (Type SGMRX) or "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) or regular gypsum board may replace "Versico Recovery Board" in any existing noncombustible roof deck Classification. When this is done, the resulting roof covering system is acceptable for use over minimum 15/32-in. thick combustible roof decks. The butt joints in the gypsum board are offset a minimum of 6-in. from the butt joints in the roof deck. Minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Gypsum- Fiber Roof Board" (Type FRX-G) is limited to a maximum 3:12 slope when used over a combustible roof deck in a system with any UL Classified insulation except polystyrene. Minimum 1/2-in. thick United States Gypsum Co. "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) is limited to a maximum 1:12 slope when used over a combustible roof deck in a system without insulation or with any UL Classified polystyrene insulation. Minimum 1/2-in. thick gypsum board, minimum 1/4-in. thick Owens Corning "Strataguard", minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Glass-Mat Roof Board" (Type SGMRX) or "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" may be used in any existing noncombustible roof deck Classification. When this is done, the resulting roof covering system is acceptable for use over minimum 15/32-in. thick combustible roof decks. The butt joints in the gypsum board and overlayment board are offset a minimum of 6-in. with the butt joints in the roof deck. Minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) is limited to a maximum slope of 3:12 when used as a thermal barrier over a combustible roof deck in a system with any UL Classified insulation except polystyrene. Minimum 1/2-in. thick United States Gypsum Co. "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) is limited to a maximum 1:12 slope when used as a thermal barrier over a combustible roof deck in a system without insulation or with any UL Classified polystyrene insulation. Unless otherwise indicated, Johns Manville "ENRGY 3 Plus" (composite) insulation may replace the "Versico Recovery Board" over polyisocyanurate insulation in any of the systems mentioned below. Unless otherwise indicated, any UL Classified wood fiber board may replace "Versico Recovery Board" in any of the systems mentioned below. Unless otherwise indicated, any UL Classified wood fiber board, any oriented strand board (OSB), "DuraFaceR", "DuraFaceR NH" or Hunter Panels "H-Shield-NB", "H-Shield NB NH" may replace Versico "Recovery Board" in any of the systems mentioned below. Unless otherwise indicated, on non-combustible decks, Carlisle Versico "SecurShield HD", "SecurShield HD NH", "SecurShield HD Plus", "SecurShield HD Plus NH", "SecurShield HD Composite", "SecurShield HD Composite NH", "DuraFaceR", "DuraFaceR NH", or Hunter Panels "H- Shield HD", "H-Shield HD NH","H-Shield HD90", "H-Shield HD90 NH", "H-Shield HD Composite", "H- Shield HD Composite CG", "H-Shield HD Composite CG NH", "H-Shield-NB" or "H-Shield-NB NH" may replace, or be used in addition to, any Versico product or any UL Classified wood fiberboard, in any UL Classified insulated roofing system assembly and retain the classification of that assembly, though the max slope cannot exceed 1/2:12 if Versico "SecurShield HD", "SecurShield HD NH", "SecurShield HD Plus", "SecurShield HD Plus NH", or "SecurShield HD Composite", "SecurShield HD Composite NH" or Hunter Panels "H-Shield HD", "H-Shield HD NH" "H-Shield HD90", "H-Shield HD90 NH", "H-Shield HD Composite" or "H-Shield HD Composite CG", "H-Shield HD Composite CG NH", is used directly below TPO membrane. Unless otherwise indicated, on combustible decks, Carlisle Versico "SecurShield HD", "SecurShield HD NH", "SecurShield HD Plus", "SecurShield HD11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 5/103 Plus NH", "SecurShield HD Composite", "SecurShield HD Composite NH", "DuraFaceR", "DuraFaceR NH", or Hunter Panels "H-Shield HD", "H-Shield HD NH","H-Shield HD90", "H-Shield HD90 NH", "H-Shield HD Composite", "H-Shield HD Composite CG", "H-Shield HD Composite CG NH", "H-Shield-NB" or "H-Shield-NB NH" may be used in addition to any Versico polyisocyanurate product or may replace, or be used in addition to, any UL Classified wood fiber board, in any insulated UL Classified roofing system assembly and retain the classification of that assembly, though the max slope cannot exceed 1/2:12 if Versico "SecurShield HD", "SecurShield HD NH", "SecurShield HD Plus", "SecurShield HD Plus NH", or "SecurShield HD Composite", "SecurShield HD Composite NH" or Hunter Panels "H-Shield HD","H-Shield HD NH" "H-Shield HD90","H-Shield HD90 NH", "H- Shield HD Composite" or "H-Shield HD Composite CG", "H-Shield HD Composite CG NH", is used directly below TPO membrane. Minimum 1/2 in. thick Carlisle Versico "SecurShield HD", "SecurShield HD NH", "SecurShield HD Plus", "SecurShield HD Plus NH", "SecurShield HD Composite", "SecurShield HD Composite NH" or Hunter Panels "H-Shield HD", "H-Shield HD NH" , "H-Shield HD90", "H-Shield HD90 NH", "H-Shield HD Composite" or "H-Shield HD Composite CG", "H-Shield HD Composite CG NH", may be used over any UL Classified polystyrene on non-combustible decks. Maximum incline shall be in accordance with the Classification established for the insulation/membrane roof covering system, but cannot exceed 2:12. Uniform or tapered insulation may be used in the following assemblies provided they do not exceed the indicated incline or thickness and carry a UL label. The following insulations, uniform thickness or tapered, may be used interchangeably: Versico Inc. "MP-H" or "VersiCore MP-H" and "WeatherBond XP", "MP-HWF" and "WeatherBond XP-WF", "MP- HF" and "WeatherBond XP-HF", "MP-HNB" and "WeatherBond XP-NB", "SecurShield" and "WeatherBond XFP", "SecurShield HD" and "WeatherBond XFP HD Cover Board", "SecurShield HD Composite" and "WeatherBond XFP HD Composite", "SecureShield HD Plus" and "WeatherBond XFP HD Plus Cover Board". Minimum 1/2-in. thick "SecurShield HD" or "SecurShield HD Plus" or "SecurShield HD Composite" or minimum 1/2-in. thick Hunter Panels "H-Shield HD" or "H-Shield HD90", "H-Shield HD Composite" or "H-Shield HD Composite CG" may be used over any UL Classified polystyrene on non-combustible roof decks. Maximum incline shall be in accordance with the Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. Uniform thick or tapered insulation may be used in the following assemblies provided they do not exceed the indicated incline or thickness and carry a UL label. Unless otherwise indicated, the term "Referenced Insulations" will include the following: Versico "Polyiso MP-H", "VersiCore MP-H", "VersiCore MP-H NH", "Polyiso MP-W", "Polyiso MP-R", "Polyiso MP-WLC", "Polyiso MP-HCG", "Tapered Polyiso", "Polyiso MP-N", "SecurShield-N", "Tapered SecurShield-N", "SecurShield", "SecurShield NH", "SecurShield-W", "SecurShield HD", "SecurShield HD NH", "SecurShield HD Plus", "SecurShield HD Plus NH", "SecurShield HD Composite", "SecurShield HD Composite NH", "Tapered Polyiso MP-HCG", "Tapered SecurShield", "Tapered SecurShield NH", "Polyiso MP-HDD", Atlas Roofing "ACFoam II" or "ACFoam III", Dow "Hy-Therm AP", Hunter Panels "H-Shield", "H-Shield NH", "H-Shield ca", "H-Shieldw", "H-Shield-CG", "H-Shield- CG NH", "H-Shield CGw", "H-Shield HD", "H-Shield HD NH", "H-Shield HD90", "H-Shield HD90 NH", "H-Shield HD Composite", "H-Shield HD Composite CG" or "H-Shield HD Composite CG NH", Johns Manville "ENRGY- 2", or "ENRGY-3", Firestone Building Products "ISO 95+GL", "GW" or "HF", Rmax Operating LLC "Multi-Max"(EPDM only), any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 6/103 Any UL Classified Expanded (EPS) or Extruded (XPS), maximum density 1.25 pcf, any thickness, may be used below the referenced Versico or Hunter Panels polyisocyanurate insulations on non- combustible decks provided a minimum 1- in. thick layer of Versico or Hunter Panels polyisocyanurate insulation is used. Maximum incline shall be in accordance with Classification established for the polyisocyanurate insulation/membrane roofing system, but cannot exceed 1:12. "VersiGard Reinforced EPDM" membrane is classified in 45 to 75 mil thicknesses. "VersiGard FR Reinforced EPDM" membrane is classified in 45 to 60 mil thicknesses. "WeatherBond Standard Reinforced EPDM" 75-mil thick may be used in lieu of "VersiGard Reinforced EPDM" 45 and 60-mil thick in any of the following systems. A membrane assembly, (without polyisocyanurate directly below the membrane), utilizing any of Versico's membranes, can be surfaced with two coats of "Versico X-Tenda Coating" at a maximum 1- 1/2 gal./100-ft.2/coat and improve its slope up to a maximum 2-in. slope. A membrane assembly, utilizing any of Versico's membranes, can be surfaced with two coats of "Versico X-Tenda Coating" at a maximum 1-1/2 gal./100-ft.2/coat and maintain the slope of the uncoated assembly. Unless otherwise indicated in the systems described below, any adhesive splice may be overlaid with pressure-sensitive flashing. "Polyiso MP-H", "VersiCore MP-H", and "VersiCore MP-H NH" may be used in any UL Classified insulated roofing system assembly that incorporates the use of any UL Classified polyisocyanurate insulation. "WeatherBond FR EPDM" 90-mil is an acceptable alternate to the 45 and 60-mil thick "VersiGard FR EPDM" in any applicable Classification. In any applicable Classification listed below, "WeatherBond EPDM" may be used in lieu of "VersiGard FR EPDM"; "WeatherBond White EPDM " may be used in lieu of "VersiGard White EPDM"; "WeatherBond Standard Reinforced EPDM Membrane" may be used in lieu of "VersiGard Reinforced EPDM Membrane"; "WeatherBond PVC" may be used in lieu of "VersiFlex PVC"; "WeatherBond TPO" may be used in lieu of "VersiWeld TPO"; WeatherBond PAS TPO Membrane" may be used in lieu of "VersiWeld QA TPO Membrane". United Solar Ovonic LLC's Field-Assembled Photovoltaic (Solar) Module Systems, "PVL-29, -31, -58, -60, -62, -64, -68, -87, -93, -116, -120, -124, -128, -136 and -144", may be installed over any UL Classified Versico roofing membrane assembly. The Module system is either adhered directly to the roofing membrane in the field or adhered to an intermediate roofing material layer in the factory (using an adhesive below or a film over top) and then attached to the roofing membrane in the field using heat welding, adhesive around the perimeter or fasteners. The Classification applies to combustible and non-combustible roof decks. The maximum incline and Classification (Class A, B or C) shall be in accordance with the Classification established for the membrane roofing assembly, however the incline cannot exceed 1-1/2:12 for EPDM and PVC membranes and 1:12 for TPO membranes. In the roof covering systems described below, the "Alutrix FR" or "VapAir Seal™ MD" vapor barrier may be used below the insulation. The vapor barrier may be applied to either the thermal barrier or directly to the roof deck.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 7/103 A vapor barrier (non-UL Classified) may be used below the insulation in any of the following systems without affecting the Classification. The "APEEL Protective Film" applied to any UL Classified Versico Inc. TPO membrane is removed after the completion of installation of the roof covering system. The Classification established for the UL Classified Versico Inc. TPO membrane roof covering system would be maintained. "VersiFleece E PVC" may be substituted for "VersiFleece FRS KEE Membrane". Unless otherwise indicated, on non-combustible roof decks, "SecurShield HD NH" or "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH" or "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite", "H-Shield HD Composite CG" ,"H-Shield-NB" may replace, or be used in addition to, any "VersiCore MP-H NH" or "WeatherBond XP NH" or Hunter Panels "H-Shield" products or any UL Classified wood fiberboard, in any UL Classified insulated roof covering system assembly and retain the classification of that assembly, though the maximum slope cannot exceed 1/2:12 if "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite", "H-Shield HD Composite CG", is used directly below TPO membrane. Unless otherwise indicated, on combustible roof decks, "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD Composite NH", "WeatherBond XFP HD Composite NH", "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite", "H-Shield HD Composite CG" or "H-Shield-NB", may be used in addition to any "VersiCore MP-H NH" or "WeatherBond XP NH" or Hunter Panels H"-Shield" product or any UL Classified wood fiber board, in any insulated UL Classified roof covering system assembly and retain the classification of that assembly, though the maximum slope cannot exceed 1/2:12 if "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite", "H-Shield HD Composite CG", is used directly below TPO membrane. Minimum 1/2 in. thick "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board". "SecurShield HD Composite NH", "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield HD" or "H-Shield HD90"), "H- Shield HD Composite", "H-Shield HD Composite CG", may be used over any UL Classified polystyrene on non-combustible roof decks. Maximum incline shall be in accordance with the Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. Unless otherwise indicated, "VersiCore MP-H NH" or "WeatherBond XP NH" or Hunter Panels "H- Shield-DD" or "H-Shield-DD NH" may be used as an alternate to "VersiCore MP-H NH" or "WeatherBond XP NH" or Hunter Panels "H-Shield" or "Tapered H-Shield-DD" or "H-Shield-DD NH" may be used as an alternate to "Tapered H-Shield" or tapered in the following insulated roof covering assemblies VersiCore MP-H NH" or "WeatherBond XP NH" or Hunter Panels "H-Shield" or "H-Shield ca" may be used in any UL Classified insulated roof covering system assembly that incorporates the use of any UL Classified polyisocyanurate insulation. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 8/103 Any Versico TPO finished product may also include the statement "with APEEL Protective Film" as part of the trade name. The "APEEL Protective Film" is removed after the completion of the installation of the roofing covering system. The Certification established for the UL Certified Versico TPO membrane roofing systems would be maintained. Use of the V2T IP, LLC Pressure Equalizing Vent System is permissible within any Versico roofing system assembly without altering the indicated fire Classification. DETEC SYSTEMS LLC, "TruGround™ Conductive Primer", applied at 1/3 gal/100 ft2 may be used within any Versico roofing system assembly without altering the indicated fire Classification. For Combustible Roof Decks - Class A: 1. A minimum 3-in. thick layer or a minimum two layers of 1.5-in. thick "SecurShield" or "SecurShield HD Composite" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG" or "SecurShield NH" or "WeatherBond XFP NH" or "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" is placed directly over a combustible roof deck and is covered with any Versico Inc. roof covering membrane used in any of the following minimum Class A assembly listings to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3- in. minimum total thickness of "SecurShield" or "SecurShield HD Composite" or "SecurShield NH" or "WeatherBond XFP NH" or "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG". All insulation butt joints must be staggered a minimum of 6-in. from the roof deck joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 2. A minimum 2.5-in. thick layer of Versico Inc. "SecurShield" or SecurShield HD Composite" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG" or "SecurShield NH" or "WeatherBond XFP NH" or "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" is placed over a minimum 2.5- in. thick layer of any UL Classified insulation (except expanded or extruded polystyrene) over a combustible roof deck. The insulation is covered with any UL Classified roof covering membrane used in any UL Class A roof covering assembly to achieve a Class A fire Classification. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation butt joints must be staggered a minimum of 6- in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 3. A minimum 1.9-in. thick layer of "SecurShield" or "SecurShield HD Composite" or "SecurShield NH" or "WeatherBond XFP NH" or "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG" is placed over a minimum 1 layer of Versico Inc. "FR Base Sheet 1S" or GAF "VersaShield FB-1S" over a combustible roof deck. The insulation is covered with any Versico Inc. roof covering membrane used in any of the following minimum Class A assembly listings to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene),11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 9/103 any combination, any thickness, may be used below the 1.9-in. minimum total thickness of "SecurShield" or "SecurShield HD Composite" or "SecurShield NH" or "WeatherBond XFP NH" or "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG". All layers may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 4. A minimum 1/2-in. thick layer of "SecurShield HD" or "SecurShield HD Plus" or "SecurShield HD NH" or "WeatherBond XFP HD NH Cover Board" or "SecurShield HD Plus NH" or "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD RL "over a minimum 2.5-in. thick layer of any Versico Inc. or Hunter Panels Classified polyisocyanurate insulation is placed directly over a combustible roof deck and is covered with any Versico Inc. roofing membrane used in any of the following minimum Class A assembly listings to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum total thickness. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 5. A minimum 1/2-in. thick layer of "SecurShield HD" or "SecurShield HD Plus" or SecurShield HD NH" or "WeatherBond XFP HD NH Cover Board" or "SecurShield HD Plus NH" or "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD RL" over a minimum 1.4-in. thick layer of any Versico Inc. or Hunter Panels Classified polyisocyanurate insulation is placed over a minimum of 1 layer of Versico Inc. "FR Base Sheet 1S" or GAF "VersaShield FB-1S" over a combustible roof deck. The insulation is covered with any Versico Inc. roofing membrane used in any of the following minimum Class A assembly listings to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum total thickness. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation butt joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 6. A minimum 1-in. thick layer of "SecurShield CD" or "WeatherBond XFP CD" or "SecurShield CD NH" or "WeatherBond XFP CD NH" is placed directly over a combustible roof deck and is covered with any UL Classified roofing membrane used in any UL Class A roof covering assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1-in. minimum thickness of "SecurShield CD", "WeatherBond XFP CD", "SecurShield CD NH" or "WeatherBond XFP CD NH". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 10/103 cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation butt joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 7. A minimum 1/2-in. thick layer of "SecurShield HD" or "SecurShield HD Plus" or "SecurShield HD NH" or "WeatherBond XFP HD NH Cover Board" or "SecurShield HD Plus NH" or "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD RL" over a minimum 4-in. thick layer of any UL Classified EPS insulation is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roof covering assembly to achieve a Class A fire Classification. Any UL Classified insulation, any combination, any thickness, may be used below the 4- 1/2 in. minimum total thickness. Insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. "SecurShield HD", "SecurShield HD Plus", "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH" or "WeatherBond XFP HD Plus NH Cover Board" must be attached with fasteners and plates. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation butt joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly as published on UL's Product iQ™ database for the product category Roofing Systems (TGFU) however, the incline cannot exceed 1/2:12. 8. A minimum 1-in. thick layer of "SecurShield CD" or "WeatherBond XFP CD" over a minimum 3-1/2 in. thick layer of any UL Classified EPS insulation is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roof covering assembly to achieve a Class A fire Classification. Any UL Classified insulation, any combination, any thickness, may be used below the 4- 1/2 in. minimum total thickness. Insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. "SecurShield CD", "WeatherBond XFP CD", "SecurShield CD NH" or "WeatherBond XFP CD NH" must be attached with fasteners and plates. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation butt joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly as published on UL's Product iQ™ database for the product category Roofing Systems (TGFU) however, the incline cannot exceed 1/2:12. 9. A minimum 1/2 in. thick layer of "SecurShield HD FR" or "WeatherBond XFP HD FR" is placed directly over a combustible roof deck and is covered with any UL Versico Inc Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below minimum 1/2 in. thick "SecurShield HD FR" or "WeatherBond XFP HD FR". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6- in. from the roof deck joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 11/103 10. A minimum 1/2 in. thick layer of "SecurShield HD FR" or "WeatherBond XFP HD FR" over a minimum 3-1/2 in. layer of any UL Classified EPS insulation is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. Any UL Classified insulation, any combination, any thickness, may be used below the 4-1/2 in. minimum total thickness. Insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. "SecurShield HD FR" or "WeatherBond XFP HD FR" must be attached with fasteners and plates. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6- in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly as published on UL's Product iQ™ database for the product category Roofing Systems (TGFU); however the incline cannot exceed 1/2:12. 11. One layer of the "VersiFleece FR TPO" is placed directly over a combustible roof deck to achieve a Class A fire Classification. The maximum incline cannot exceed 1/4:12. 12. A minimum 1-in. thick layer of "SecurShield CD" or "WeatherBond XFP CD" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1 in. minimum thickness of "SecurShield CD" or "WeatherBond XFP CD". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6 in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 13. A minimum 1-in. thick layer of "SecurShield CD" or "WeatherBond XFP CD" over a minimum 3-1/2 in. thick layer of any UL Classified EPS insulation is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. Any UL Classified insulation, any combination, any thickness, may be used below the 4-1/2 in. minimum total thickness. All layers may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly published on UL's Product iQ™ database for the Classifications published under the product category of Roofing Systems (TGFU); however the incline cannot exceed 1/2:12. 14. One layer of the "VersiFleece FR TPO" or " "WeatherBond TPO FR Fleece", is placed directly over a combustible roof deck to achieve a Class A fire Classification. The maximum incline cannot exceed 1/4:12. 15. A minimum 1-in. thick layer of Versico "SecurShield" or "SecurShield NH"; or WeatherBond "XFP" or " XFP NH" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 12/103 insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1 in. minimum thickness of Versico "SecurShield" or "SecurShield NH"; or WeatherBond "XFP" or " XFP NH". All layers may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 12 in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. 16. A minimum 1-in. thick layer of Versico "SecureShield" or "SecurShield NH"; or WeatherBond "XFP" or "XFP NH" over a minimum 3-1/2 in. thick layer of any UL Classified EPS insulation is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. Any UL Classified insulation, any combination, any thickness, may be used below the 4-1/2 in. minimum total thickness. All layers may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 12-in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly as published on UL's Product iQ™ database for the Classifications published under the product category of Roofing Systems (TGFU); however the incline cannot exceed 1/2:12 17. A minimum 1/2 in. thick layer of Versico "SecurShield HD", "SecurShield HD Plus", "SecurShield HD NH", "SecurShield HD Plus NH" or "VersiCore RL" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A roof covering assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1/2 in. minimum thickness. All layers may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 12 in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly as published on UL's On-Line Certification Directory for the product category Roofing Systems (TGFU); however the incline cannot exceed 1:12. For Combustible Roof Decks - Class B: 1. A minimum 1.9-in. thick layer of "SecurShield NH", "WeatherBond XFP NH", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG" or a minimum 2-in. thick layer of Atlas Roofing Corp. "AC Foam III" is placed directly over a combustible roof deck and is covered with any Versico Inc. roofing membrane used in any of the following minimum Class B assembly listings to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum thickness layer of "SecurShield NH", "WeatherBond XFP NH", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield- CG", "H-Shield HD Composite" or "H-Shield HD Composite CG" or 2-in. minimum thickness layer of Atlas Roofing Corp. "AC Foam III". All insulation butt joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 13/103 joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 2. A minimum 1/2-in. thick layer of "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board" or "SecurShield HD RL" over a minimum 1.4-in. thick layer of any Versico Inc. or Hunter Panels Classified polyisocyanurate insulation is placed directly over a combustible roof deck and is covered with any Versico Inc. roof covering membrane used in any of the following minimum Class B assembly listings to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum total thickness. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation butt joints must be staggered a minimum of 6-in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 3. A minimum 1-in. thick layer of "SecurShield CD" or "WeatherBond XFP HD Cover Board" or "SecurShield CD NH" or "WeatherBond XFP CD NH" is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A or B roof covering assembly to achieve a Class B fire Classification. Any UL Classified insulation, any combination, any thickness, may be used below the "SecurShield CD", "WeatherBond XFP HD Cover Board", "SecurShield CD NH", "WeatherBond XFP CD NH". Insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation butt joints must be staggered a minimum of 6- in. from the roof deck butt joints or from the insulation butt joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly as published on UL's Product iQ™ database for the product category Roofing Systems (TGFU). 4. A minimum 1/2 in. thick layer of "SecurShield HD FR" or "WeatherBond XFP HD FR" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A or B roofing assembly to achieve a Class B fire Classification. Any UL Classified insulation, any combination, any thickness, may be used below the "SecurShield HD FR" or "WeatherBond XFP HD FR". Insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly as published on UL's Product iQ™ database for the product category Roofing Systems (TGFU). Unless otherwise indicated, Classifications for "VersiFlex PVC" include 50-mil, 60-mil and 80-mil thick membranes. "VersiFlex FRS PVC", "WeatherBond PVC FRS", "VersiFlex-E KEE HP" or "WeatherBond KEE HP" Membrane are acceptable alternates to "VersiFlex PVC" in any applicable Classification. For adhered "VersiFlex PVC" assemblies, the membrane is adhered with Versico Inc. "PVC Bonding Adhesive" or "Low VOC PVC Bonding Adhesive" at 45 to 65-ft2/gal., Versico Inc. "Aqua Base 120 Bonding Adhesive" at 120-ft2/gal., Versico Inc. "HydroBond PVC Adhesive" at 125-11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 14/103 ft2/gal., Ashland Inc. "Pliobond 7008" at 165-ft2/gal. or Sika Sarnafil Inc. "Sarnacol 2121" at 125- ft2/gal. The use of the "VersiFlex PVC Rib Profiles" or "WeatherBond PVC Rib Profile" may be used over any Classified "VersiFlex" PVC roof covering system, provided minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" or United States Gypsum Co. "SECUROCK Roof Board" is used as the barrier board. maximum incline shall be in accordance with the Classification established for the barrier board/membrane roof covering system. The use of the "VersiWeld TPO Rib Profile" or "WeatherBond TPO Rib Profile", spaced minimum 18- in. on center, may be used over any Classified "VersiWeld TPO" roof covering system, provided minimum 1/4-in. Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" or United States Gypsum Co. "SECUROCK Roof Board" is used as the barrier board. Maximum incline shall be in accordance with the Classification established for the barrier board/membrane roof covering system. Unless otherwise indicated "Spectro-Weld", "PVW" and "GeoTPO" may be used in lieu of "Sure-Weld VersiWeld TPO" membrane in any applicable Classification. Unless otherwise indicated Atlas Roofing Corp. "FR 50" is an acceptable alternate for the "FR Base Sheet" at a maximum incline of 1-1/2:12. UL2218A Impact Resistance: Any UL Classified Versico Inc. TPO Roof covering System is Classified for UL 2218A Class 4 Impact Resistance when the following conditions are met: 1. 80-mil (nominal thickness) Versico Inc. "VersiWeld TPO" or "VersiWeld HS TPO" or "VersiFleece TPO" or "VersiFleece AC TPO" membrane is applied over any of the following substrates: Barrier Board oriented Strand Board, Plywood or Slipsheet over Plywood. These substrates may be placed over insulation or additional substrate layers as specified in the roof covering systems. The substrate layer(s) are attached with Versico Inc. fasteners and minimum 2-in. metal or plastic plates. 2. 45-60 mil (nominal thickness) Versico Inc. "VersiWeld TPO", "VersiFleece TPO" "VersiWeld HS TPO" or "VersiFleece AC TPO" membrane is applied over any combination of substrate layers, as specified in the roof covering systems, and the top substrate layer is attached with adhesives or asphalt. Lower substrate layers may be attached with fasteners and plates, adhesives or asphalt. Any UL Classified Versico Inc. non-fleece PVC roof covering system is Classified for UL2218A Class 4 Impact Resistance when either of the following conditions are met: 1. 80-mil (nominal thickness) Versico Inc. "VersiFlex PVC", "FRS, KEE HP" or "VersiFlex VersiFleece PVC" membrane is applied over any combination of substrate layers, as specified in the roof covering systems, and the substrate layer(s) are attached with Versico Inc. fasteners and minimum 2-in. metal or plastic plates. 2. 50-60 mil (nominal thickness) Versico Inc. "VersiFlex PVC", "FRS, KEE HP" or "VersiFlex VersiFleece PVC" membrane is applied over any combination of substrate11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 15/103 layers, as specified in the roof covering systems, and the top substrate layer is attached with adhesives or asphalt. Lower substrate layer(s) may be attached with fasteners and plates, adhesives or asphalt. Any UL Classified Versico Inc. non-fleece EPDM Roof Covering system is Classified for UL2218A Class 4 Impact Resistance when either of the following conditions are met: 1. Minimum 75-mil (nominal thickness) "VersiGard Reinforced EPDM", "VersiGard Reinforced FR EPDM" or "VersiFleece EPDM" membrane is applied over any combination of substrate layers, as specified in the roof covering systems, and the substrate layer(s) are attached with Versico Inc. fasteners and minimum 2-in. metal or plastic plates. 2. Minimum 60-mil (nominal thickness) "VersiGard Reinforced EPDM", "VersiGard Reinforced FR EPDM" or "VersiFleece EPDM" membrane is applied over any of the following substrates: Barrier Board, Oriented Strand Board, Plywood or Slipsheet over Plywood. These substrates may be placed over insulation or additional substrate layers as specified in the roof covering systems. The substrate layer(s) are attached with Versico Inc. fasteners and minimum 2-in. metal or plastic plates. 3. Minimum 45 mil (nominal thickness) any Versico Inc. EPDM or VersiFleece EPDM membrane is applied over any combination of substrate layers, as specified in the roof covering systems, and the top substrate layer is attached with adhesives or asphalt. Lower substrate layer(s) may be attached with fasteners and plates, adhesives or asphalt. Any UL Classified Versico Inc. ballasted roof covering system described below is Classified for UL2218A Class 4 Impact Resistance. Class A - Ballasted Unless otherwise indicated in the systems described below, the insulation and the membrane are laid loosely and surfaced with river bottom stone, nom 1-1/2 in. diameter at 1000-lbs/100-ft.2 minimum. Suitable alternates are size Nos. 1, 2, 3, 4 and 24 (as per ASTM D448), also at 1000-lbs/100-ft.2 minimum. In addition, concrete pavers or crushed stone may be used. Pavers must weigh 1000- lbs/100-ft.2 minimum and spaced no more than 1/8-in. apart and the crushed stone must meet the above size and weight requirements. Versico's HP Protective mat (not Classified) may be used between membrane and ballast, insulation and ballast (Irma System) or membrane and deck. Membrane splices, 3 to 4-in. wide are adhered with "Splice Adhesive" at 130 to 150-lineal ft./gal and may be sealed with "CCW-704 Mastic"; Before the splice is assembled, a 3/16-in. diameter bead of "V350 In-Seam Sealant" is applied to the seam area. Splice edges are covered with "G300LS Black Lap Sealant" or "WeatherBond Black Lap Sealant" at 11-oz/22-lin ft. Unless otherwise indicated, any of the reinforced membranes ("VersiGard Reinforced EPDM Membrane", "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM") may be substituted for the membrane described in the following ballasted systems. Unless otherwise indicated in the systems described below, 3 to 11-in. wide "VersiGard Quick Applied Seam Tape", "WeatherBond Peel & Stick Seam Tape", "VersiGard White Quick Applied Seam Tape" or "WeatherBond White Peel & Stick Seam Tape", may be used in any Classification where a black or11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 16/103 white EPDM membrane is specified, respectively. An appropriate primer may be used to clean membrane surface. Unless otherwise indicated in the systems described below, any completed splice may be overlaid with pressure-sensitive flashing. Unless otherwise indicated, any UL Classified Versico Inc. membrane may be utilized in the ballasted assemblies described below. "MP-HF" may be used in any of the insulated ballasted systems below. 1. Deck: NC Incline: 2 Insulation: — Any UL Classified insulation, any thickness, any combination. Membrane: — "VersiGard EPDM", 0.045 or 0.060 in. 2. Deck: C-15/32 Incline: 2 Membrane: — "VersiGard EPDM", 0.045 or 0.060 in. 3. Deck: C-15/32 Incline: 1 Insulation: — Minimum 3/4-in. thick perlite over minimum 1/2-in. thick wood fiber; minimum 3/4 in. thick perlite over minimum 1/2-in. thick wood fiber over maximum 5-in. thick polystyrene. Membrane: — "VersiGard EPDM", 0.045 or 0.060-in. 4. Deck: C-15/32 Incline: 2 Insulation: — One of or combination of the following, any thickness: A.) Gypsum Board. B.) Any UL Classified insulation over gypsum board. Membrane: — "VersiGard EPDM", 0.045 or 0.060-in. 5. Deck: C-15/32 Incline: 2 Insulation (Below Membrane - Optional): — 1 layer, any Classified insulation - any thickness. Membrane: — "VersiGard EPDM", 0.045 or 0.060 in. Insulation (Above Insulation): — Dow Chemical "Styrofoam-RM, -RM-60 or -LG", 4 in. maximum or UC Industries "Foamular 404, 154 and 254", 8-in. maximum. Surfacing: — As an alternate to loose laid ballast, insulation boards may be surfaced with minimum 3/8-in. thick concrete topping 6. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified insulation, any thickness. Membrane: — Any Versico Inc. Classified membrane, loose laid, adhered or mechanically fastened.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 17/103 Surfacing: — Stone or paver ballast applied at minimum 10-lb/1ft2. 7. Deck: NC Incline: 2 Insulation (Optional): — Any UL Classified, any thickness. Insulation (Optional): — "Versico Recovery Board", mechanically fastened or fully adhered with hot roofing asphalt. Membrane: — Any UL Classified. Surfacing: — River bottom stone (3/4-in. to 1-1/2 in. diameter) applied at 1000-lb/100-ft2. 8. Deck: NC Incline: 1 Insulation: — Dow Chemical "Styrofoam" polystyrene, Celotex "Rmax Operating LLC" polyurethane, glass fiber or perlite, 3/4 to 2-in., laid loosely. Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" laid loosely. Surfacing: — Gravel at 600-lb/100-ft.2, laid loosely. 9. Deck: NC Incline: 2 Insulation: — One layer perlite, 3/4-in. thick, laid loosely, followed by one layer Dow Chemical "U-Thane 210", 1 to 5 in. thick, laid loosely. Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" laid loosely. Surfacing: — River bottom stone (3/4 to 1-1/2 in. diameter) at 1000-lb/100-ft.2 10. Deck: C-15/32 Incline: 1/2 Insulation: — Polystyrene, 1 to 3-in. thick, laid loosely. Slip Sheet: — "Flex FR-50", Atlas Roofing Corp. "FR-50", laid loosely. Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" laid loosely. Surfacing: — Gravel at 1000-lb/100-ft.2 11. Deck: NC Incline: 1/2 Insulation: — Arco Chemical "Arcor SP" uniform thickness or tapered, 1.6-in. thick minimum, laid loosely or mechanically fastened. Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" laid loosely. Surfacing: — River bottom stone (3/4 to 1-1/2 in. diameter) at 1000-lb/100-ft.2 12. Deck: C-15/32 Incline: 1/2 Insulation: — Arco Chemical "Arcor MB" or "Arcor FM-1", uniform thickness or tapered, 1.6-in. thick minimum, mechanically fastened. Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" laid loosely. Surfacing: — River bottom stone (3/4 to 1-1/2 in. diameter) at 1000-lb/100-ft.2 13. Deck: Structural Cement Fiber Unit Incline: 1/2 Insulation: — Glass fiber, perlite or polyisocyanurate, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 18/103 Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" laid loosely. Surfacing: — Gravel at 1000-lb/100-ft.2 laid loosely. 14. Deck: NC Impact: 2 Insulation: — "VersiCore MP-H NH" or "WeatherBond XP NH" or "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels "H-Shield", "H-Shield-F", "H-Shield-NB", "H-Shield- P", "H-Shield-RP", "H-Shield-C", "H-Shield-WF", "H-Shield-F NH", "H-Shield-P NH", "H-Shield- RP NH", "H-Shield-C NH" or "H-Shield-WF NH", any thickness. Membrane: — Any UL Classified, laid loosely. Surfacing: — River Bottom Stone (3/4 to 1-1/2 in. diameter), 1000-lbs/100-ft.2 Class A - Fully Adhered (EPDM) In the adhered roof covering systems described below, the insulation is mechanically attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may be used below the insulation. Unless otherwise indicated, the specified membrane is adhered to the insulation with "G200SA Yellow Substrate Adhesive" or "WeatherBond LC-60 Bonding Adhesive" or "EPDM X-23 Low-VOC Bonding Adhesive" or "Low-VOC Bonding Adhesive 1168" at 1-1/3 gal/100- ft.2. Field membrane splices, 3 to 4-in. wide are adhered with "Splice Adhesive" at 130-150 lineal ft./gal. Before the splice is assembled, a 3/16-in. bead of "V350 In-Seam Sealant" may be applied to the seam area. Splice edges may be covered with "G300LS Black Lap Sealant" or "WeatherBond Black Lap Sealant" at 11-oz/22 lineal ft. or sealed with "CCW-704 Mastic". In the white EPDM systems described below, the installation is the same as listed above except "G100B White Seam Adhesive" is used in the place of "G100B Seam Adhesive" and "G-300 LS White Lap Sealant" or "WeatherBond White Lap Sealant" are used in place of "G300LS Black Lap Sealant" or "WeatherBond Black Lap Sealant". Coverage rates are the same. In the "VersiGard White EPDM" Systems described below, the installation is the same as listed above except "G100SA White Splice Cement" is used in the place of "Splice Adhesive" and "G-300 LS White Lap Sealant" is used in place of "G-300 LS Black Lap Sealant". Coverage rates are the same. Unless otherwise indicated, minimum 7/16-in. thick non-veneer APA rated oriented strand board may be substituted for "Versico Recovery Board" in the following systems. Unless otherwise indicated in the systems described below, 3 to 11-in. wide "VersiGard Quick Applied Seam Tape", "WeatherBond Peel & Stick Seam Tape", "VersiGard White Quick Applied Seam Tape" or "WeatherBond White Peel & Stick Seam Tape", may be used for field membrane splices in any Classification. An appropriate primer may be used to clean membrane surface. Unless otherwise indicated in the systems described below, any adhesive splice may be overlaid with pressure-sensitive flashing. In any of the following systems, concrete decking or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" overlayment board may be primed with "CCW-702 Primer" or "CCW-714 Primer" and optionally covered with "VapAir Seal 725TR". 1. Deck: NC Incline: 1 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 19/103 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2-in. minimum, over any Classified insulation, any thickness; cellular concrete, pre-cast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiGard EPDM", " VersiGardFR EPDM ", 0.045 or 0.060 in. 2. Deck: NC Incline: 2-1/2 Insulation: — "Versico Recovery Board", 1/2 to 5-in. thick; "Versico Recovery Board", 1/2-in. minimum, over any Classified insulation, any combination , any thickness. Membrane: — "VersiGard EPDM", 0.045 or 0.060 in. Surfacing: — 1 coat "G-700HC Hysunite Coating" coating at 2/3-gal/100-ft2. Dry silica sand at 35-lbs/100-ft2 is broadcast onto wet coating. Excess sand may be removed after coating has air dried. Bald (unsanded) spots shall be recoated and re-sanded at same rates. 3. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 0.045 or 0.060 in. (System Designation - Design A). 4. Deck: C-15/32 Incline: 1/2 Barrier Board: — minimum 1/2-in. thick gypsum board. Insulation: — See Referenced Insulation, any combination, any thickness. Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 0.045 or 0.060 in. 5. Deck: C-15/32 Incline: 1 Insulation: — One of or combination of the following: A.) minimum 1/2-in. thick gypsum board B.) minimum 1/2-in. thick gypsum board over any combination of Classified insulation, any thickness; "Versico Recovery Board", 1/2-in. thick minimum over gypsum board; "Versico Recovery Board", 1/2-in. thick minimum, polyisocyanurate or urethane, any total thickness, over gypsum board. Membrane: — "VersiGard EPDM", 0.045 or 0.060-in. or "VersiGard FR EPDM" or "WeatherBond FR EPDM", 0.045 or 0.060-in. 6. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard White EPDM", 0.045 or 0.060-in. 7. Deck: NC Incline: 1-1/2 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick or "Versico Recovery Board", 1/2-in. minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 20/103 Membrane: — "VersiGard White EPDM", 0.045 or 0.060-in. 8. Deck: C-15/32 Incline: 1-1/2 Insulation: — One of or combination of the following: A.) minimum 1/2-in. thick gypsum board. B.) minimum 1/2-in. thick gypsum board over any Classified insulation, any combination, any thickness. C.) "Versico Recovery Board", 1/2-in. thick minimum, over gypsum board. D.) "Versico Recovery Board", 1/2-in. thick minimum, over any Classified insulation, any combination, any total thickness, over gypsum board. Membrane: — "VersiGard White EPDM", 0.045 or 0.060-in. 9. Deck: C-15/32 Incline: 1/2 Barrier Board: — minimum 1/2-in. thick gypsum board. Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard White EPDM", 0.045 or 0.060-in. 10. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard Reinforced EPDM Membrane ", 0.045 or 0.060-in. 11. Deck: NC Incline: 3/4 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. minimum over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard Reinforced EPDM", 0.045 or 0.060-in. 12. Deck: C-15/32 Incline: 1/2 Barrier Board: — minimum 1/2-in. thick gypsum board. Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard Reinforced EPDM", 0.045 or 0.060-in. 13. Deck: C-15/32 Incline: 3/4 Insulation: — One of or combination of the following: A.) minimum 1/2-in. thick gypsum board. B.) minimum 1/2-in. thick gypsum board over any Classified insulation, any combination, any thickness; "Versico Recovery Board", 1/2-in. thick minimum over gypsum board; "Versico Recovery Board", 1/2-in. thick minimum over any Classified insulation, any combination, any thickness, over gypsum board.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 21/103 Membrane: — "VersiGard Reinforced EPDM", 0.045 or 0.060-in. 14. Deck: C-15/32 or NC Incline: 4 Insulation: — One of or combination of the following, any thickness: A.) minimum 1/2-in. thick gypsum board. B.) minimum 1/2-in. thick gypsum board over any Classified insulation, any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 0.045 or 0.060-in. 15. Deck: NC Incline: 3/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 0.045 or 0.060-in. 16. Deck: C-15/32 Incline: 1 Barrier Board: — minimum 1/2-in. thick gypsum board. Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 0.045 or 0.060-in. 17. Deck: NC Incline: 2-1/2 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. minimum over any Classified insulation , any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 0.045 or 0.060-in. 18. Deck: NC Incline: 2-1/2 Insulation: — Oriented strand board, Oriented strand board over any Classified insulation , any combination, any thickness. Membrane: — "VersiGard White EPDM", 0.045 or 0.060-in. 19. Deck: C-15/32 Incline: 2-1/2 Insulation: — One of or combination of the following: A.) Oriented Strand Board over minimum 1/2-in. thick gypsum board. B.) Oriented Strand Board over any Classified insulation, any combination, any total thickness, over minimum 1/2-in. thick gypsum board. Membrane: — "VersiGard White EPDM", 0.045 or 0.060-in.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 22/103 20. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. minimum over any Classified insulation, any combination, any thickness; cellular concrete, pre-cast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 0.060-in. adhered with "B-500" Latex Bonding Adhesive at 1-gal/100-ft2. 21. Deck: NC Incline: 3/4 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2 in. minimum over any Classified insulation, any combination, any thickness; cellular concrete, pre-cast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiGard Reinforced EPDM Membrane", 0.045 or 0.060 in. adhered with "B-500" Latex Bonding Adhesive at 1-gal/100-ft2. 22. Deck: NC Incline: 1-1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 0.045 or 0.060-in. adhered with "B-500" Latex Bonding Adhesive at 1-gal/100-ft2. 23. Deck: NC Incline: 2-1/2 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. minimum over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 0.045 or 0.060-in. adhered with "B-500" Latex Bonding Adhesive at 1-gal/100-ft2. 24. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard White EPDM", 0.045 or 0.060-in. adhered with "B-500" Latex Bonding Adhesive at 1-gal/100-ft2. 25. Deck: NC Incline: 1/2 Insulation: — "Versico Recovery Board", 1/2 to 3 in. thick or "Versico Recovery Board", 1/2-in. minimum over any Classified insulation, any combination, any thickness; cellular concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard White EPDM", 0.045 or 0.060 in. adhered with "B-500" Latex Bonding Adhesive at 1-gal/100-ft2. 26. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 23/103 Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 0.060 in. adhered with "B-500" Latex Bonding Adhesive at 1-gal/100-ft2. 27. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S" or three layers GAF "VersaShield FB-1S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system, but cannot exceed 2:12. 28. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 29. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 3/4:12. 30. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — "Polyiso MP-WLC" or Atlas Roofing Corp. "ACFoam III", minimum 1.5-in. thick with joints staggered minimum 6-in. from the deck joints. Membrane: — Any UL Classified Versico Inc. membrane except "VersiGard EPDM". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 31. Deck: C-15/32 Incline: 1/2 Slip Sheet: — Two layer Atlas Roofing Corp. "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 24/103 Membrane: — "VersiGard Reinforced EPDM", "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM". 32. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS or fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 33. Deck: NC Incline: Unlimited Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 0.045 - 0.090 in. 34. Deck: NC Incline: 1/2 Insulation (Optional): — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 45 to 90 mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 35. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3-in.thick or "Versico Recovery Board", 1/2-in. thick minimum over any Classified insulation, any combination, any thickness; cellular concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 45 to 90 mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 36. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board Membrane: — "VersiGard FR EPDM" or "WeatherBond FR EPDM", 45 to 90 mil., adhered with" Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 37. Deck: NC Incline: 1/2 Insulation (Optional): — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil, adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 38. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick or "Versico Recovery Board", 1/2-in. thick minimum over any Classified insulation, any combination, any thickness;11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 25/103 cellular concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil, adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 39. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil, adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 40. Deck: NC Incline: 3/4 Insulation (Optional): — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60 mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 41. Deck: NC Incline: 2-1/2 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick or "Versico Recovery Board", 1/2-in. thick minimum over any Classified insulation, any combination, any thickness; cellular concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 42. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60 mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 43. Deck: C-15/32 Incline: 1 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Gypsum Board Membrane: — — "VersiGard White EPDM VersiGard", 45 to 60-mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 44. Deck: NC Incline: 1/2 Insulation (Optional): — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR EPDM", "WeatherBond FR EPDM", "VersiGard White EPDM", "WeatherBond White EPDM", "VersiGard Reinforced EPDM", "WeatherBond Standard Reinforced EPDM", "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", adhered with "WeatherBond Cav-Grip III Adhesive/Primer" or "Cav- Grip 3V Adhesive/Primer". Total application rate is 0.45 gal./100-ft.2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 26/103 45. Deck: NC Incline: 1 Insulation: — Versico "Recovery Board", 1/2 to 3-in. thick or Versico "Recovery Board", minimum 1/2 in. thick over any Classified insulation, any combination, any thickness; cellular concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard FR EPDM", "WeatherBond FR EPDM" , "VersiGard White EPDM", "WeatherBond White EPDM", "VersiGard Reinforced EPDM", "WeatherBond Standard Reinforced EPDM", "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", adhered with "WeatherBond Cav-Grip III Adhesive/Primer" or "Cav- Grip 3V Adhesive/Primer". Total application rate is 0.45 gal./100-ft.2. 46. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2 in. min gypsum board or minimum 1/4 in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard", "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiGard FR EPDM", "WeatherBond FR EPDM", "VersiGard Reinforced EPDM", "WeatherBond Standard Reinforced EPDM", "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM" , adhered with "WeatherBond Cav-Grip III Adhesive/Primer" or "Cav-Grip 3V Adhesive/Primer". Total application rate is 0.45 gal./100-ft.2. 47. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2 in. min gypsum board or minimum 1/4 in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard", "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiGard White EPDM" or "WeatherBond White EPDM", adhered with "WeatherBond Cav-Grip III Adhesive/Primer" or "Cav-Grip 3V Adhesive/Primer". Total application rate is 0.45 gal./100-ft.2. 48. Deck: NC Incline: See Note 1 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH CoverBoard", minimum 5/16-in. thick. Membrane: — Any UL Classified EPDM membrane (See Note 1). Note 1: Classification and incline are determined by the current Classified Roof Covering System consisting of EPDM membrane installed directly over the specific UL Classified insulation used, but cannot exceed 2-1/2:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 49. Deck: C-15/32 Incline: 2 Insulation: — Any UL Classified polyisocyanurate insulation, minimum 2-in. thick, with all butt joints staggered minimum of 6-in. from plywood roof deck butt joints. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 27/103 Cover Board: — "DuraStorm VSH CoverBoard" minimum 7/16-in. thick, mechanically fastened. Membrane: — Any UL Classified EPDM membrane, minimum 50-mil thick (See Note 2). Note 2: Classification and incline are determined by the current Classified Roof Covering System consisting of EPDM membrane installed directly over the specific UL Classified polyisocyanurate insulation used, but the resulting incline cannot exceed 1:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. Class A - Hook and Loop Adhered (EPDM) 1. Deck: NC Incline: 1/2 Insulation: — (Optional) Any UL Classified Insulation, any combination, any thickness. Insulation: — "VersiCore RL", "SecurShield RL" or "SecurShield HD RL", any combination, any thickness. Membrane: — "VersiFleece RL EPDM", "VersiFleece RL PVC" 2. Deck: C-15/32 Incline: 1/2 Barrier Board: — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard™ Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Gypsum Fiber Roof Board" (Type FRX-G) or "SECUROCK® Glass-Mat Roof Board" (Type SGMRX). Insulation (Optional): — Any UL Classified Insulation, any combination, any thickness. Insulation: — "VersiCore RL", "SecurShield RL" or "SecurShield HD RL", any combination, any thickness. Membrane: — "VersiFleece RL EPDM", "VersiFleece RL PVC" Class B - Fully Adhered (EPDM) 1. Deck: NC Incline: 1/2 Insulation: — Any Classified insulation, any combination, any thickness. Membrane: — 0.045 or 0.060 in. Surfacing: — One coat "G-700HC Hysunite Coating" coating at 2/3-gal/100-ft2. Dry silica sand at 35-lbs/100-ft2 is broadcast onto wet coating. Excess sand may be removed after coating has air dried. Bald (unsanded) spots shall be recoated and re-sanded at same rates. 2. Deck: C-15/32 Incline: See Note Base Sheet: — One layer, mechanically fastened, of one of the following: A.) Owens Corning "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 28/103 D.) Tamko Building Products Inc. "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G.) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — See "Referenced Insulations", minimum 1-1/2 in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1-in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1/2-in. thick over polyisocyanurate or urethane (any combination), minimum 1 in. thick. The bottom insulation layer joints are to be staggered a minimum 6 in. from the roof deck joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 3. Deck: C-15/32 Incline: See Note Insulation: — "Versico Recovery Board" or UL Classified wood fiber board, minimum 1- 1/2 in. thick. The bottom insulation layer joints are to be staggered a minimum 6-in. from the deck joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 4. Deck: NC Incline: Unlimited Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick, "Versico Recovery Board", 1/2- in. thick minimum over any Classified insulation , any combination , any thickness; cellular concrete, precast concrete with grouted joints or structural (poured in place) concrete. Membrane: — "Versico FR Reinforced EPDM", 0.045 or 0.060 in. Coating: — Two coats "Versico Acrylic Coating" at a maximum of 1-1/2 gal./100-ft2/coat. Class C - Fully Adhered (EPDM) 1. Deck: NC Incline: 1 Insulation: — UC Industries "Foamular 150 or 250" or "Durapink", 2-in. maximum, mechanically fastened. Membrane: — "VersiGard White EPDM VersiGard", 0.045 or 0.060-in., adhered with "B- 500" Latex Bonding Adhesive at 1-gal./100-ft2. 2. Deck: C-15/32 Incline: 1 Barrier Board: — Gypsum board, 0.463-in. thick minimum, weighing 184-lbs/100-ft.2 minimum. Insulation: — UC Industries "Foamular 150 or 250" or "Durapink", 2 in. thick maximum, mechanically fastened.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 29/103 Membrane: — "VersiGard White EPDM VersiGard", 0.045 or 0.060-in., adhered with "B- 500" Latex Bonding Adhesive at 1-gal./100-ft.2. 3. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. EPDM membrane. 4. Deck: NC Incline: 1/2 Insulation (Optional): — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard White EPDM VersiGard", 45 to 60-mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 5. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3 in. thick or "Versico Recovery Board", 1/2-in. thick minimum over any Classified insulation, any combination, any thickness; cellular concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard White EPDM VersiGard", 45 to 60-mil., adhered with "Aqua Base 120" Bonding Adhesive at 120-ft2/gal. 6. Deck: C-15/32 Incline: Unlimited Insulation: — "VersiCore MP-H NH" or "WeatherBond XP NH", "SecurShield NH" or "WeatherBond XFP NH Polyiso" or "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels "H-Shield", "H-Shield-CG", "H-Shield-F", "H-Shield-Premier", "H-Shield- HD", "H-Shield-HD90", "H-Shield-HD Composite", "H-Shield-HD Composite-CG", "H- Shield-WF", "H-Shield-NB", "H-Shield-F NH", "H-Shield-Premier NH", "H-Shield-WF NH", any combination, any thickness. Membrane: — Any EPDM membrane Classified by UL for a Class A, B or C rating when used directly over polyisocyanurate insulation. 7 Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — DuraStorm VSH Cover Board", minimum 5/16-in. thick, with all butt joints staggered a minimum of 6-in. from the plywood roof deck butt joints. Membrane: — Any UL Classified EPDM membrane. Class A - Fully Adhered (EPDM) - Pressure-Sensitive Membrane 1. Deck: NC Incline: 2 Insulation: — Oriented Strand Board (OSB), 7/16 in. thick minimum over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 30/103 Membrane: — "VersiGard QA Reinforced EPDM" or "WeatherBond PAS Reinforced EPDM". 2. Deck: NC Incline: 1/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard QA Reinforced EPDM" or "WeatherBond PAS Reinforced EPDM". 3. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — 1/2 in. thick minimum gypsum board or 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard", "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiGard QA Reinforced EPDM" or "WeatherBond PAS Reinforced EPDM". 4. Deck: NC Incline: 2 Insulation: — Oriented Strand Board (OSB), 7/16 in. thick minimum over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiGard QA Non-Reinforced EPDM" or "WeatherBond PAS Non- Reinforced EPDM". 5. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard QA Non-Reinforced EPDM" or "WeatherBond PAS Non- Reinforced EPDM". 6. Deck: NC Incline: Unlimited Insulation: — Any UL Classified, any combination, any thickness. Barrier Board: — 1/2 in. thick minimum gypsum board or 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard", "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiGard QA Non-Reinforced EPDM" or "WeatherBond PAS Non- Reinforced EPDM". 7. Deck: NC Incline: 3/4 Insulation (Optional): — Any UL Classified Insulation, any combination, any thickness. Insulation: — 1/2-inch "SecurShield HD", any combination, any thickness. Membrane: — "VersiGard QA White Non-Reinforced EPDM" or "WeatherBond PAS White Non-Reinforced EPDM". 8. Deck: C-15/32 or NC Incline: 1 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 31/103 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — 1/2 in. thick minimum gypsum board or 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard", "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiGard QA White Non-Reinforced EPDM" or "WeatherBond PAS White Non-Reinforced EPDM". Class A - Mechanically Fastened (EPDM) In the Mechanically Fastened Systems described below, the insulation is attached with mechanical fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL Classified) may be used below the insulation. The specified membrane is secured over the insulation by mechanical fasteners and plates or fastening bars and fasteners placed in the field splices. Field membrane splices, 3-in. minimum wide, are adhered with "Splice Adhesive" at 85 to 95 lineal ft./gal. Before the splice is assembled, a 3/16-in. bead of "V350 In-Seam Sealant" is applied to the seam area. Splice edges may be covered with "G300LS Black Lap Sealant" or "WeatherBond Black Lap Sealant" at 11-oz./22-lineal ft. or may be sealed with "CCW-704 Mastic". Unless otherwise indicated in the systems described below, 3 to 11-in. wide "VersiGard Quick Applied Seam Tape", "WeatherBond Peel & Stick Seam Tape", "VersiGard White Quick Applied Seam Tape" or "WeatherBond White Peel & Stick Seam Tape", may be used for field membrane splices in any Classification. An appropriate primer may be used to clean membrane surface. Unless otherwise indicated in the systems described below, any adhesive splice may be overlaid with pressure-sensitive flashing. 1. Deck: NC Incline: 3/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil 2. Deck: NC Incline: 2-1/2 Insulation: — "Versico Recovery Board", 1/2 to 3-in.; "Versico Recovery Board", 1/2-in. minimum, over any Classified insulation , any thickness, any combination; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil. 3. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil 4. Deck: NC Incline: 3/4 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness; cellular11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 32/103 concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil 5. Deck: C-15/32 or NC Incline: 4 Insulation: — One of or combination of the following, any thickness: A.) Minimum 1/2-in. thick gypsum board. B.) Minimum 1/2-in. thick gypsum board over any Classified insulation, any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil. 6. Deck: C-15/32 Incline: 3/4 Insulation: — One of or combination of the following: A.) Gypsum board. B.) Gypsum board over any Classified insulation, any combination, any thickness; "Versico Recovery Board", 1/2-in. minimum over gypsum board; "Versico Recovery Board", 1/2-in. minimum over any Classified insulation, any combination, any thickness, over gypsum board. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil 7. Deck: C-15/32 Incline: 3/4 Barrier Board: — Minimum 1/2-in. thick gypsum board. Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil 8. Deck: C-15/32 Incline: 1/2 Barrier Board: — Gypsum board. Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil 9. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 10. Deck: C-15/32 Incline: See Note 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 33/103 Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Atlas Roofing Corp. "ACFoam III", minimum 1.5 in. thick with joints staggered minimum 6-in. from the deck joints. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 11. Deck: C-15/32 Incline: 1/2 Slip Sheet: — Two layers Atlas Roofing Corp. "FR-50". Membrane: — "VersiGard Reinforced EPDM Membrane" 12. Deck: NC Incline: 1 Insulation: — Any UL Classified expanded or extruded polystyrene, any combination, any thickness. Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. reinforced EPDM membrane. 13. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1- 1/2:12. 14. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 15. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 16 Deck: NC Incline: See Note 1 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 34/103 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick. Membrane: — Any UL Classified EPDM membrane (See Note 1). Note 1: Classification and incline are determined by the current Classified Roof Covering System consisting of the EPDM membrane installed directly over the specific UL Classified insulation used, but cannot exceed 2-1/2:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 17 Deck: C-15/32 Incline: See Note 2 Insulation: — Any UL Classified polyisocyanurate insulation, minimum 2-in. thick, with all butt joints staggered minimum of 6-in. from plywood roof deck butt joints. Cover Board: — "DuraStorm VSH Cover Board" minimum 7/16-in. thick, mechanically fastened. Membrane: — Any UL Classified EPDM membrane, minimum 50-mil thick (See Note 2). Note 2: Classification and incline are determined by the current Classified Roof Covering System consisting of EPDM membrane installed directly over the specific UL Classified polyisocyanurate insulation used, but the resulting incline cannot exceed 1:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 18 Deck: NC Incline: See Note Insulation(Optional): — MP-H", "VersiCore MP-H", "WeatherBond XP", "VersiCore MP-H NH" or "WeatherBond XP NH", any combination, any thickness. Insulation: — 1/2-in. thick "VersiCore HD" or " WeatherBond XP HD" Membrane: — Any UL Classified EPDM mechanically fastened membrane assembly. Note: Maximum incline shall be in accordance with Classification established for insulation/membrane roofing system. Class B - Mechanically Fastened (EPDM) 1. Deck: NC Incline: 4 Insulation: — "Versico Recovery Board", 1/2 to 3 in. thick; "Versico Recovery Board", 1/2- in. thick minimum over polyisocyanurate or urethane, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured in place) concrete. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil 2. Deck: C-15/32 Incline: 4 Insulation: — One of or combination of the following, any thickness: A.) Minimum 1/2-in. thick gypsum board. B.) Minimum 1/2-in. thick gypsum board over polyisocyanurate or urethane, any thickness; "Versico Recovery Board", 1/2-in. thick minimum over gypsum11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 35/103 board; "Versico Recovery Board", 1/2-in. thick minimum over polyisocyanurate, urethane, any total thickness, over gypsum board. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil 3. Deck: C-15/32 Incline: 1 Base Sheet: — One layer, mechanically fastened, of one of the following: A.) Owens Corning "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase". D.) Tamko Building Products Inc. "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G.) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — "VersiGard Reinforced EPDM Membrane" 4. Deck: C-15/32 Incline: See Note Base Sheet: — One layer, mechanically fastened, of one the following: A.) Owens Corning "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase". D.) Tamko Building Products Inc. "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G.) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — See " Referenced Insulations", minimum 1-1/2 in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1-in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1/2-in. thick over any Classified insulation (any combination), minimum 1-in. thick. The bottom insulation layer joints are to be staggered a minimum 6-in. from the roof deck joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 36/103 5. Deck: C-15/32 Incline: See Note Insulation: — "Versico Recovery Board" or UL Classified wood fiber board, minimum 1- 1/2 in. thick; The bottom insulation layer butt joints are to be staggered a minimum of 6-in. from the roof deck butt joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 6. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1- 1/2:12. Class C - Mechanically Fastened (EPDM) 1. Deck: NC Incline: 2 Insulation (Optional): — Any UL Classified, any combination , any thickness. Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — "VersiGard FR EPDM" or "VersiGard" or "WeatherBond FR EPDM", 45 to 90 mil 2. Deck: NC Incline: 1 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil 3. Deck: C-15/32 Incline: 1 Base Sheet: — One layer, mechanically fastened, of one of the following: A.) Johns Manville "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase". D.) Tamko Building Products Inc. "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G) GAF "VersaShield Underlayment" or "VersaShield FB-2S". 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 37/103 Membrane: — Any UL Classified Versico Inc. EPDM membrane. 4. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. EPDM membrane. 5. Deck: C-15/32 Incline: Unlimited Insulation: — "VersiCore MP-H NH", "WeatherBond XP NH", "SecurShield CD NH", "WeatherBond XFP CD NH", "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD Composite NH", "WeatherBond XFP HD Composite NH", "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels "H-Shield", "H-Shield-CG", "H-Shield- F", "H-Shield Premier", "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite", "H- Shield HD Composite CG", "H-Shield-WF", "H-Shield-NB", "H-Shield- CG NH", "H-Shield- F NH", "H-Shield-WF NH" any combination, any thickness. Membrane: — Any EPDM membrane Classified by UL for a Class A, B or C rating when used directly over polyisocyanurate insulation. 6 Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick, with all butt joints staggered a minimum of 6-in. from the plywood roof deck butt joints. Membrane: — Any UL Classified EPDM membrane. Class A - Mechanically Fastened (TPO) 1. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld TPO" or "WeatherBond TPO". 2. Deck: NC Incline: 1-1/2 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiWeld TPO" or "WeatherBond TPO". 3. Deck: NC Incline: 1-1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO". 4. Deck: NC Incline: 1-1/2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 38/103 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO". 5. Deck: C-15/32 or NC Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Membrane: — "VersiWeld TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO", "WeatherBond HS Plus TPO" or "WeatherBond TPO". 6. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. . Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 7. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO". 8. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Atlas Roofing Corp. "ACFoam III", 1.5-in. thick with joints staggered minimum 6-in. from the roof deck joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 9. Deck: C-15/32 Incline: 1/2 Slip Sheet: — Two plies Atlas Roofing Corp. "FR-50". Membrane: — Any UL Classified Versico Inc. membrane.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 39/103 10. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1- 1/2:12. 11. Deck: C-15/32 Incline: 2-1/2 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board. Membrane: — "VersiWeld Plus TPO" or "WeatherBond TPO Plus". 12. Deck: NC Incline: 1-1/2 Insulation: — "Versico HP Recovery Board", 1/2-in. to 3-in. thick, "Versico Recover Board", 1/2-in. thick minimum, over any Classification insulation, any combination, any thickness, cellular concrete, precast concrete with grouted joists or structural (poured-in- place) concrete. Membrane: — "VersiWeld Plus TPO" or "WeatherBond TPO Plus". 13. Deck: NC Incline: 1/2 Insulation: — See: "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld Plus TPO" or "WeatherBond TPO Plus". 14. Deck: NC Incline: 1/2 Insulation: — See: "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135". 15. Deck: NC Incline: 1-1/2 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — 1/2-in. thick "Versico Recovery Board". Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135". 16. Deck: NC Incline: 3 Insulation: — Any UL Classified, any thickness. Barrier Board: — minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" or minimum 1/2-in. thick gypsum wallboard. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 40/103 17. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation : — Any UL Classified (except EPS ), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 18. Deck: NC Incline: 1 Insulation: — Any UL Classified insulation, any combination, any thickness. Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S" Membrane: — Any UL Classified Versico Inc. TPO membrane. 19. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 20. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 21 Deck: NC Incline: See Note 1 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick. Membrane: — Any UL Classified TPO membrane (See Note 1). Note 1: Classification and incline are determined by the current Classified Roof Covering System consisting of TPO membrane installed directly over the specific UL Classified insulation used, but cannot exceed 2-1/2:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 22 Deck: NC Incline: See Note Insulation (Optional): — "MP-H", "VersiCore MP-H", "WeatherBond XP", "VersiCore MP- H NH" or "WeatherBond XP NH", any combination, any thickness. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 41/103 Insulation: — 1/2-in. thick "VersiCore HD" or " WeatherBond XP HD" Membrane: — Any UL Classified TPO mechanically fastened membrane assembly. Note Maximum incline shall be in accordance with Classification established for insulation/membrane roof covering system. Class B - Mechanically Fastened (TPO) 1. Deck: C-15/32 Incline: See Note Base Sheet: — One layer, mechanically fastened, of one the following: A.) Owens Corning "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase". D.) Tamko "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G.) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — See "Referenced Insulations", minimum 1-1/2 in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1-in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1/2-in. thick over any Classified insulation (any combination), minimum 1-in. thick. The bottom insulation layer butt joints are to be staggered a minimum of 6-in. from the deck butt joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 2. Deck: C-15/32 Incline: See Note Insulation: — "Versico Recovery Board" or UL Classified wood fiber board, minimum 1- 1/2 in. thick. The bottom insulation layer joints are to be staggered a minimum of 6-in. from the roof deck butt joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 3. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1- 1/2:12.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 42/103 4. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Polyisocyanurate, minimum 1-in. thick. Slip Sheet: — Two layers Atlas Roofing Corp. "FR 50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — Any UL Classified Versico Inc. TPO membrane. 5. Deck: C-15/32 Incline: 1/2 Slip Sheet: — One ply Atlas Roofing Corp. "FR-50". Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO". Class C - Mechanically Fastened (TPO) 1. Deck: C-15/32 Incline: 1 Base Sheet: — One layer, mechanically fastened, of one of the following: A.) Johns Manville "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase". D.) Tamko "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. TPO membrane. 2. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. TPO membrane. 3. Deck: NC Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld TPO", "WeatherBond TPO", "VersiWeld Plus ", "WeatherBond TPO Plus", "VersiWeld HS", "WeatherBond HS TPO", "VersiWeld HS Plus" or "WeatherBond HS Plus", 45 to 80-mil thickness. 4. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum 2-in thick.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 43/103 Membrane: — "VersiWeld TPO", "WeatherBond TPO", "VersiWeld Plus TPO", "WeatherBond TPO Plus", "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus" or "WeatherBond HS Plus", 45 to 80-mil thickness. 5. Deck: C-15/32 Incline: Unlimited Insulation: — "VersiCore MP-H NH", "WeatherBond XP NH", "SecurShield CD NH", "WeatherBond XFP CD NH", "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD Composite NH", "WeatherBond XFP HD Composite NH", "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels H-Shield", "H-Shield-CG", "H-Shield- F", "H-Shield Premier", "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite", "H- Shield HD Composite CG", "H-Shield-WF", "H-Shield-NB", "H-Shield- CG NH", "H-Shield- F NH", "H-Shield-WF NH" or any combination, any thickness. Membrane: — Any TPO membrane Classified by UL for a Class A, B or C rating when used directly over polyisocyanurate insulation. 6 Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick, with all butt joints staggered a minimum of 6-in. from the plywood roof deck butt joints. Membrane: — Any UL Classified TPO membrane. Class A - Fully Adhered (TPO) Unless otherwise indicated, "Low-VOC Bonding Adhesive" or "WeatherBond TPO Bonding Adhesive" or "Low-VOC Bonding Adhesive 1168" may be used in lieu of "VersiWeld TPO Bonding Adhesive" in any of the systems mentioned below. 1. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3 in. thick; "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiWeld HS", "WeatherBond HS TPO", "VersiWeld HS Plus" or "WeatherBond HS Plus", fully adhered with "VersiWeld TPO Bonding Adhesive", at 1-1/3 gal./100-ft.2. 2. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld HS", "WeatherBond HS TPO", "VersiWeld HS Plus" or "WeatherBond HS Plus", fully adhered with "VersiWeld TPO Bonding Adhesive", at 1-1/3 gal./100-ft.2. 3. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified , any combination, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 44/103 Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiWeld HS", "WeatherBond HS TPO", "VersiWeld HS Plus" or "WeatherBond HS Plus", fully adhered with "VersiWeld TPO Bonding Adhesive" at 1-1/3 gal/100-ft2. 4. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 5. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Atlas Roofing Corp. "ACFoam III", minimum 1.5-in. thick with butt joints staggered minimum of 6-in. from the deck butt joints. Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 6. Deck: NC Incline: 1-1/2 Insulation: — "Versico Recovery Board", 1/2 to 3 in. thick, "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness, cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiWeld TPO" or "WeatherBond TPO", fully adhered with "VersiWeld TPO Bonding Adhesive", at 1-1/3 gal/100-ft2. 7. Deck: NC Incline: 1/4 Insulation: — "Polyiso MP-W" or Atlas Roofing Corp. "ACFoamII", any thickness. Membrane: — "VersiWeld TPO" or "WeatherBond TPO", fully adhered with "VersiWeld TPO Bonding Adhesive" at 1-1/3 gal/100-ft2. 8. Deck: NC Incline: 1/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld TPO" or "WeatherBond TPO", fully adhered with "VersiWeld TPO Bonding Adhesive" at 1-1/3 gal./100-ft.2. 9. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified , any combination, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 45/103 Barrier Board: — 1/2-in. thick minimum gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiWeld TPO" or "WeatherBond TPO", fully adhered with "VersiWeld TPO Bonding Adhesive" at 1-1/3 gal./100-ft.2. 10. Deck: C-15/32 Incline: 2-1/2 Impact: 2 Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — 1/2-in. thick minimum gypsum board. Membrane: — "VersiWeld Plus TPO" or "WeatherBond TPO Plus", fully adhered with "VersiWeld TPO Bonding Adhesive" at 1-1/3 gal./100-ft.2. 11. Deck: C-15/32 Incline: Unlimited Slip Sheet: — Three layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS or fiberboard), any combination, any thickness. Membrane: — "VersiWeld HS" , "WeatherBond HS TPO", "VersiWeld HS Plus" or "WeatherBond HS Plus TPO" membrane, fully adhered with "VersiWeld TPO Bonding Adhesive" at 1-1/3 gal./100-ft.2. 12. Deck: NC Incline: 3/8 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld TPO" or "WeatherBond TPO" or "VersiWeld Plus TPO" or "WeatherBond TPO Plus", fully adhered with "Aqua Base 120 Bonding Adhesive", at 120 ft2/gal. 13. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", fully adhered with "Aqua Base 120 Bonding Adhesive", at 120 ft.2/gal. 14. Deck: NC Incline: 1/2 Insulation: — "Versico Recovery Board", 1/2 to 3 in. thick, "Versico Recovery Board", 1/2 in. minimum, over any Classified insulation, any combination, any thickness, cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiWeld TPO" or "WeatherBond TPO", fully adhered with "Aqua Base 120 Bonding Adhesive", at 120-ft.2/ gal. 15. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3 in. thick, "Versico Recovery Board", 1/2 in. thick minimum, over any Classified insulation, any combination, any thickness, cellular 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 46/103 concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", fully adhered with "Aqua Base 120 Bonding Adhesive", at 120-ft.2/gal. 16. Deck: NC Incline: 1 Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiWeld TPO" or "WeatherBond TPO", "VersiWeld Plus TPO" or "WeatherBond TPO Plus", "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", fully adhered with "Aqua Base 120 Bonding Adhesive" at 120-ft.2/gal. 17. Deck: C-15/32 Incline: 1 Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Membrane: — "VersiWeld TPO" or "WeatherBond TPO", "VersiWeld Plus TPO" or "WeatherBond TPO Plus", "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", fully adhered with "Aqua Base 120 Bonding Adhesive" at 120-ft.2/gal. 18. Deck: NC Incline: 1/4 Insulation (Optional): — See "Referenced Insulations", any combination, any thickness. Membrane: — VersiWeld TPO", "WeatherBond TPO", "VersiWeld Plus TPO", "WeatherBond TPO Plus", "VersiWeld HS TPO" or "WeatherBond HS TPO" adhered with "WeatherBond Cav-Grip III Adhesive/Primer". Total application rate is 0.45 gal./100-ft.2. 19. Deck: NC Incline: 1 Insulation: — Versico "Recovery Board", 1/2 to 3 in. thick or Versico "Recovery Board", minimum 1/2 in. thick over any Classified insulation, any combination, any thickness; cellular concrete with grouted joints or structural (poured in place) concrete. Membrane: — VersiWeld TPO", "WeatherBond TPO", "VersiWeld Plus TPO", "WeatherBond TPO Plus", "VersiWeld HS TPO" or "WeatherBond HS TPO" adhered with "WeatherBond Cav-Grip III Adhesive/Primer" or "Cav-Grip 3V Adhesive/Primer". Total application rate is 0.45 gal./100-ft.2. 20. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 47/103 Barrier Board: — Minimum 1/2 in. thick gypsum board or minimum 1/4 in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard", "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiWeld TPO", "WeatherBond TPO", "VersiWeld Plus TPO", "WeatherBond TPO Plus", "VersiWeld HS TPO" or "WeatherBond HS TPO" adhered with "WeatherBond Cav-Grip III Adhesive/Primer" or "Cav-Grip 3V Adhesive/Primer". Total application rate is 0.45 gal./100-ft.2. 21 Deck: NC Incline: See Note 1 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick. Membrane: — Any UL Classified TPO membrane (See Note 1). Note 1: Classification and incline are determined by the current Classified Roof Covering System consisting of TPO membrane installed directly over the specific UL Classified insulation used, but cannot exceed 2-1/2:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. Class A - Hook and Loop Adhered (TPO) 1. Deck: NC Incline: 1/2 Insulation: — (Optional) Any UL Classified Insulation, any combination, any thickness. Insulation: — "VersiCore RL", "SecurShield RL" or "SecurShield HD RL", any combination, any thickness. Membrane: — "VersiFleece RL TPO", "VersiFleece RL PVC" 2. Deck: C-15/32 Incline: 1/2 Barrier Board: — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard™ Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Gypsum Fiber Roof Board" (Type FRX-G) or "SECUROCK® Glass-Mat Roof Board" (Type SGMRX). Insulation (Optional): — Any UL Classified Insulation, any combination, any thickness. Insulation: — "VersiCore RL", "SecurShield RL" or "SecurShield HD RL", any combination, any thickness. Membrane: — "VersiFleece RL TPO", "VersiFleece RL PVC" Class B - Fully Adhered (TPO) 1. Deck: NC Incline: 3/4 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick, "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness, cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiWeld Plus TPO" or "WeatherBond TPO Plus", fully adhered with "VersiWeld TPO Bonding Adhesive", at 1-1/3 gal./100-ft.2.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 48/103 2. Deck: NC Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", fully adhered with "Aqua Base 120 Bonding Adhesive" at 120-ft.2/gal. 3. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", fully adhered with "Aqua Base 120 Bonding Adhesive" at 120-ft.2/gal. Class C - Fully Adhered (TPO) 1. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. TPO membrane. 2. Deck: NC Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — — "VersiWeld TPO" or "WeatherBond TPO", "VersiWeld Plus TPO" or "WeatherBond TPO Plus", "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", 45 to 80 mil thickness, adhered with "VersiWeld TPO Bonding Adhesive" or "G200SA Yellow Substrate Adhesive" or "WeatherBond LC-60 Bonding Adhesive" at 1-1/3 gal./100-ft.2. 3. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum 2-in. thick. Membrane: — "VersiWeld TPO" or "WeatherBond TPO", "VersiWeld Plus TPO" or "WeatherBond TPO Plus", "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO" or "WeatherBond HS Plus TPO", 45 to 80 mil thickness, adhered with "VersiWeld TPO Bonding Adhesive" or "G200SA Yellow Substrate Adhesive" or "WeatherBond LC-60 Bonding Adhesive" at 1-1/3 gal./100-ft.2. 4. Deck: C-15/32 Incline: Unlimited 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 49/103 Insulation: — "VersiCore MP-H NH" or "WeatherBond XP NH", "SecurShield NH" or "WeatherBond XFP NH" or "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels "H-Shield", "H-Shield-CG", "H-Shield-F", "H-Shield-Premier", "H-Shield-HD", "H- Shield-HD90", "H-Shield-HD Composite", "H-Shield-HD Composite-CG", "H-Shield-WF", "H-Shield-NB", "H-Shield-F NH", "H-Shield-Premier NH", "H-Shield-WF NH", any combination, any thickness. Membrane: — Any TPO membrane Classified by UL for a Class A, B or C rating when used directly over polyisocyanurate insulation. 5 Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick, with all butt joints staggered a minimum of 6-in. from the plywood roof deck butt joints. Membrane: — Any UL Classified TPO membrane. Class A - Fully Adhered (TPO) - Pressure-Sensitive Membrane 1. Deck: NC Incline: 2 Insulation: — Oriented Strand Board (OSB), 7/16-in. thick minimum; Oriented Strand Board (OSB), 7/16-in thick minimum over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in- place) concrete. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". 2. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". 3. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". 4. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 5. Deck: C-15/32 Incline: See Note 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 50/103 Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — "Polyiso MP-WLC" or Atlas Roofing Corp. "ACFoam III", minimum 1.5 in. thick with joints staggered minimum 6 in. from the deck joints. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 6. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 7. Deck: NC Incline: 1/2 Insulation (Optional): — Any UL Classified, any combination, any thickness. Insulation: — Insulfoam LLC "Insulfoam SP", minimum 1 in. thick. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". Class B - Fully Adhered (TPO) - Pressure-Sensitive Membrane 1. Deck: C-15/32 Incline: See Note Base Sheet: — One layer, mechanically fastened, of one the following: A.) Type G2 Base Sheet. B.) Versico Inc. "FR Base Sheet". C.) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — See "Referenced Insulations", minimum 1-1/2 in. thick. The bottom insulation layer butt joints are to be staggered a minimum of 6-in. from the roof deck butt joints. Membrane: — Any UL Classified Versico Inc. TPO membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1-in. Class C - Fully Adhered (TPO) - Pressure-Sensitive Membrane 1. Deleted. 2. Deck: NC Incline: Unlimited 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 51/103 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". 3. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum 2" thickness. Membrane: — "WeatherBond PAS TPO" or "VersiWeld QA TPO". Class A - Mechanically Fastened (PVC) 1. Deck: NC Incline: 1/2 Insulation: — Atlas Roofing Corp. "ACFoam II" or "ACFoam III", Dow "Hy-Therm AP", Johns Manville "ENRGY- 2" or "ENRGY-3", Rhoflex "Isocyanurate GL, GW or HF", any combination, any thickness. Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 2. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2 in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 3. Deck: NC Incline: Unlimited Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 4. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 5. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" with staggered butt joints (minimum 6-in. offset). Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 6. Deck: C-15/32 Incline: See Note 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 52/103 Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Atlas Roofing Corp. "ACFoam III", 1.5-in. thick with joints staggered minimum 6-in. from the roof deck butt joints. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 7. Deck: C-15/32 Incline: 1/2 Slip Sheet: — Two plies Atlas Roofing Corp. "FR-50". Membrane: — Any UL Classified Versico Inc. PVC membrane. 8. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1- 1/2:12. 9. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation (Optional): — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 2:12. 10. Deck: NC Incline: 1 Insulation: — Any UL Classified expanded or extruded polystyrene, any combination, any thickness Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S" Membrane: — Any UL Classified Versico Inc. PVC membrane. 11. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 53/103 12. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 13. Deck: NC Incline: 1 Insulation: — Apache Building Products "Pyrox White Line", 1.2-in. thick minimum, fiberglass 7/16-in. thick minimum or perlite 3/4-in. thick minimum. Membrane: — "VersiFleece E PVC" mechanically fastened. 14. Deck: C 15/32 in.Incline: 1 Barrier Board: — Minimum 5/8-in. thick gypsum board mechanically fastened with butt joints in the barrier board offset a minimum of 6-in. from the butt joints in the plywood roof deck. Insulation: — Apache "White Line", 1.2-in. thick minimum or fiberglass 7/16-in. thick minimum or perlite 3/4-in. thick minimum. Membrane: — "VersiFleece E PVC" mechanically fastened. 15. Deck: NC Incline: 1 Insulation: — Polystyrene, any thickness. Barrier Board: — Minimum 3/4-in thick perlite. Membrane: — "VersiFleece E PVC" mechanically fastened. 16. Deck: NC Incline: 1 Insulation: — Cellular concrete, gypsum concrete, vermiculite concrete, perlite concrete or structural concrete. Membrane: — "VersiFleece E PVC" mechanically fastened. 17. Deck: C-15/32 Incline: 1 Barrier Board: — Minimum 5/8-in. thick gypsum board mechanically fastened with butt joints in the barrier board offset a minimum of 6-in. from the butt joints in the plywood roof deck. Insulation: — Polystyrene, any thickness. Cover Board: — 3/4-in. thick perlite board. Membrane: — "VersiFleece E PVC" mechanically fastened. 18. Deck: C-15/32 Incline: 2 Insulation (Optional): — Polyisocyanurate, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 54/103 Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" mechanically fastened with butt joints in the barrier board offset a minimum of 6-in. from the butt joints in the plywood roof deck. Membrane: — "VersiFleece E PVC" mechanically fastened. 19. Deck: NC Incline: 1/2 Insulation: — Dow Chemical "Hy-Tec", 1.2-in. thick minimum or fiberglass 7/16-in. thick minimum or perlite 3/4-in. thick minimum. Membrane: — "VersiFleece E PVC" mechanically fastened. 20. Deck: NC Incline: 2-1/2 Vapor Barrier (Optional): — (Not UL Classified): — (1) 6-mil polyethylene (2) B F Goodrich "Permate", (3) Johns Manville "Asbestogard", (4) Fortifiber "Pyro-Kure 600" or (5) Fortifiber "Vaporstop 298". Insulation: — One or more of the following or combinations, any thickness: Flex Membrane International Corp. "Flex ISO II" or "Versifoam MP-W" or "Versifoam MP-N". Membrane: — "VersiFleece E PVC" 50 to 100-mil mechanically fastened. 21. Deck: NC Incline: 2 Vapor Barrier (Optional): — (Not UL Classified): — (1) 6-mil polyethylene (2) B F Goodrich "Permate", (3) Johns Manville "Asbestogard", (4) Fortifiber "Pyro-Kure 600" or (5) Fortifiber "Vaporstop 298". Insulation: — Rmax Operating LLC "Thermaroof Plus-3" or "Multi Max-3", any thickness". Membrane: — "VersiFleece E PVC" 50 to 100-mil mechanically fastened. 22. Deck: NC Incline: See Note 1 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick. Membrane: — Any UL Classified PVC membrane (See Note 1). Note 1: Classification and incline are determined by the current Classified Roof Covering System consisting of PVC membrane installed directly over the specific UL Classified insulation used, but cannot exceed 2-1/2:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 23. Deck: C-15/32 Incline: See Note 2 Insulation: — Any UL Classified polyisocyanurate insulation, minimum 2-in. thick, with all butt joints staggered minimum of 6-in. from plywood roof deck butt joints. Cover Board: — "DuraStorm VSH Cover Board" minimum 7/16-in. thick, mechanically fastened. Membrane: — Any UL Classified PVC membrane, minimum 50-mil thick (See Note 2). Note 2: Classification and incline are determined by the current Classified Roof Covering System consisting of PVC membrane installed directly over the specific UL Classified polyisocyanurate insulation used, but the resulting incline cannot exceed 1:12. Membrane11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 55/103 and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 24. Deck: NC Incline: See Note Insulation (Optional): — "MP-H", "VersiCore MP-H", "WeatherBond XP", "VersiCore MP- H NH", or "WeatherBond XP NH", any combination, any thickness. Insulation: — 1/2-in. thick"VersiCore HD" or " WeatherBond XP HD" Membrane: — Any UL Classified PVC mechanically fastened membrane assembly. Note: Maximum incline shall be in accordance with Classification established for insulation/membrane roof covering system. Class B - Mechanically Fastened (PVC) 1. Deck: C-15/32 Incline: See Note Base Sheet: — One layer, mechanically fastened, of one the following: A.) Owens Corning "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase". D.) Tamko "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G.) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — See "Referenced Insulations", minimum 1-1/2 in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1-in. thick; "Versico Recovery Board" or UL Classified wood fiber board, minimum 1/2-in. thick over any Classified insulation (any combination), minimum 1-in. thick. The bottom insulation layer butt joints are to be staggered a minimum of 6-in. from the roof deck butt joints. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 2. Deck: C-15/32 Incline: See Note Insulation: — "Versico Recovery Board" or UL Classified wood fiber board, minimum 1- 1/2 in. thick. The bottom insulation layer butt joints are to be staggered a minimum 6-in. from the deck joints. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but not to exceed 1:12. 3. Deck: C-15/32 Incline: See Note 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 56/103 Slip Sheet: — One layer Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1- 1/2:12. 3A. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer GAF "VersaShield FB-1S". Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1/2:12. 4. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Polyisocyanurate, minimum 1-in. thick. Slip Sheet: — Two layers Atlas Roofing Corp. "FR 50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — Any UL Classified Versico Inc. PVC membrane. 5. Deck: C-15/32 Incline: 1/2 Slip Sheet: — One ply Atlas Roofing Corp. "FR-50". Membrane: — Any UL Classified Versico Inc. PVC membrane. Class C - Mechanically Fastened (PVC) 1. Deck: C-15/32 Incline: 1 Base Sheet: — One layer, mechanically fastened, of one of the following: A.) Johns Manville "Perma Ply No. 28". B.) GAF "GAFGLAS #75 Base Sheet". C.) Johns Manville "Glasbase". D.) Tamko Building Products Inc. "Glass Base". E.) Celotex Type G2 "Vaporbar GB". F.) Versico Inc. "FR Base Sheet". G.) GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. PVC membrane. 2. Deck: C-15/32 Incline: 1 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 57/103 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. PVC membrane. 3. Deck: NC Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 4. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum 2-in. thick. Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 5. Deck: C-15/32 Incline: 1 Insulation: — Dow Chemical "Hy-Tec" or "Energy-Lok", any thickness, mechanically fastened with butt joints in the insulation offset a minimum of 6-in. from the butt joints in the plywood roof deck. Membrane: — "VersiFleece E PVC" mechanically fastened. 6. Deck: C-15/32 Incline: 1 Slip Sheet: — Flex Membrane International "Flex FR-50" or Atlas Roofing Corp. "FR-50". Membrane: — "VersiFleece E PVC" mechanically fastened. 7. Deck: C-15/32 Incline: Unlimited Insulation: — "VersiCore MP-H NH", "WeatherBond XP NH", "SecurShield CD NH", "WeatherBond XFP CD NH", "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH", "WeatherBond XFP HD Plus NH Cover Board", "SecurShield HD Composite NH", "WeatherBond XFP HD Composite NH", "DuraFaceR NH", "WeatherBond XP-NB NH", or Hunter Panels "H-Shield", "H-Shield-CG", "H-Shield- F", "H-Shield Premier", "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite", "H- Shield HD Composite CG", "H-Shield-WF", "H-Shield-NB", "H-Shield- CG NH", "H-Shield- F NH", "H-Shield-WF NH" or any combination, any thickness. Membrane: — Any PVC membrane Classified by UL for a Class A, B or C rating when used directly over polyisocyanurate insulation. 8 Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick, with all butt joints staggered a minimum of 6-in. from the plywood roof deck butt joints. Membrane: — Any UL Classified PVC membrane. Class A - Fully Adhered (PVC) 1. Deck: NC Incline: 1-1/2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 58/103 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiFlex PVC" or "WeatherBond PVC" 2. Deck: NC Incline: 3/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFlex PVC" or "WeatherBond PVC" 3. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 4. Deck: NC Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Oriented strand board. Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 5. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S" or three layers GAF "VersaShield FB-1S". Insulation: — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system but cannot exceed 2:12. 5A. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 5B. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 59/103 Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used, but cannot exceed 3/4:12 6. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer Atlas Roofing Corp. "FR-10" or "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — "Polyiso MP-WLC" or Atlas Roofing Corp. "ACFoam III", minimum 1.5-in. thick with butt joints staggered minimum of 6-in. from the roof deck butt joints. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system. 7. Deck: C-15/32 Incline: Unlimited Slip Sheet: — Three layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation: — Any UL Classified (except EPS or fiberboard), any combination, any thickness. Membrane: — "VersiFlex PVC" or "WeatherBond PVC" 8. Deck: NC Incline: 1/2 Insulation: — Glass fiber or perlite, 3/4-in. thick minimum or wood fiber, 1-in. thick, fully adhered with hot roofing asphalt or mechanically fastened with metal insulation anchors. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with hot roofing asphalt. 9. Deck: NC Incline: 1 Insulation: — Glass fiber, perlite or wood fiber, 2-in. maximum, fully adhered with hot roofing asphalt or mechanically fastened with metal insulation anchors. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with hot roofing asphalt or fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 10. Deck: NC Incline: 1 Insulation: — Cellular concrete, gypsum concrete, vermiculite concrete, perlite concrete or structural concrete. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with hot roofing asphalt. 11. Deck: NC Incline: 1/2 Insulation: — Polystyrene any thickness, fully adhered with hot roofing asphalt or mechanically fastened. Barrier Board: — 3/4-in. thick perlite or 1-in. thick wood fiberboard. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 60/103 Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 12. Deck: NC Incline: 1/2 Insulation: — Apache "White Line", any thickness, fully adhered with hot roofing asphalt or mechanically fastened with metal insulation anchors. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 13. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Polyisocyanurate, any thickness. Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" mechanically fastened with butt joints in the barrier board offset a minimum of 6-in. from the butt joints in the plywood roof deck. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 14. Deck: NC Incline: 1 Insulation (Optional): — Polystyrene any thickness. Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" mechanically fastened with butt joints in the barrier board offset a minimum of 6-in. from the butt joints in the plywood roof deck. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 15. Deck: NC Incline: 1 Insulation (Optional): — Cellular concrete, vermiculite concrete, perlite concrete or structural concrete. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. or fully adhered with hot roofing asphalt applied at a rate of 25-lb./100-ft.2 16. Deck: NC Incline: 1/2 Insulation: — Dow Chemical "Hy-Tec" (Energy Lok), 2-in. thick maximum, fully adhered with hot roofing asphalt or mechanically fastened with metal insulation anchors. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with hot roofing asphalt or fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 17. Deck: NC Incline: 1/4 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 61/103 Insulation: — Dow Chemical "Hy-Tec" (Energy Lok), any thickness, fully adhered with hot roofing asphalt or mechanically fastened with metal insulation anchors. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 18. Deck: C-15/32 Incline: 1 Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" mechanically fastened with butt joints in the barrier board offset a minimum of 6-in. from the butt joints in the plywood roof deck. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 19. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any thickness polyisocyanurate, perlite or woodfiber mechanically fastened or adhered with UL Classified insulation adhesive. Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" mechanically fastened with butt joints in the barrier board offset a minimum of 6-in. from the butt joints in the plywood roof deck or adhered any UL Classified insulation adhesive. Base Sheet (Optional): — One ply Henry Co. "SBS Modified Plus G100 S/S Base" fully adhered with hot roofing asphalt. Membrane: — "VersiFleece FRS KEE Membrane" fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. 20 Deck: NC Incline: See Note 1 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick. Membrane: — Any UL Classified PVC membrane (See Note 1). Note 1: Classification and incline are determined by the current Classified Roof Covering System consisting of the PVC membrane installed directly over the specific UL Classified insulation used, but cannot exceed 2-1/2:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 21 Deck: C-15/32 Incline: See Note 2 Insulation: — Any UL Classified polyisocyanurate insulation, minimum 2-in. thick, with all butt joints staggered minimum of 6-in. from plywood roof deck butt joints. Cover Board: — "DuraStorm VSH Cover Board" minimum 7/16-in. thick, mechanically fastened. Membrane: — Any UL Classified PVC membrane, minimum 50-mil thick (See Note 2). Note 2: Classification and incline are determined by the current Classified Roof Covering System consisting of PVC membrane installed directly over the specific UL Classified polyisocyanurate insulation used, but the resulting incline cannot exceed 1:12. Membrane and insulation attachment methods are as described in aforementioned Classified Roof Covering System consisting of the membrane installed directly over the insulation. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 62/103 Class C - Fully Adhered (PVC) 1. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. PVC membrane. 2. Deck: NC Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 3. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum 2" thickness. Membrane: — "VersiFlex PVC" or "WeatherBond PVC". 4. Deck: C-15/32 Incline: Unlimited Insulation: — "VersiCore MP-H NH" or "WeatherBond XP NH" or "SecurShield NH" or "WeatherBond XFP NH" or "DuraFaceR NH" or "WeatherBond XP-NB NH" or Hunter Panels "H-Shield", "H-Shield-CG", "H-Shield-F", "H-Shield-Premier", "H-Shield-HD", "H- Shield-HD90", "H-Shield-HD Composite", "H-Shield-HD Composite-CG", "H-Shield-WF", "H-Shield-NB", "H-Shield-F NH", "H-Shield-Premier NH", "H-Shield-WF NH", any combination, any thickness. Membrane: — Any PVC membrane Classified by UL for a Class A, B or C rating when used directly over polyisocyanurate insulation. 5. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Any UL Classified insulation, any thickness. Cover Board: — "DuraStorm VSH Cover Board", minimum 5/16-in. thick, with all butt joints staggered a minimum of 6-in. from the plywood roof deck butt joints. Membrane: — Any UL Classified PVC membrane. Class A — Fully Adhered 'VersiFleece' with 'DASH' Adhesive - EPDM The VersiFleece EPDM membranes include "VersiFleece EPDM 100", " VersiFleece EPDM 115" and " VersiFleece EPDM 145". The VersiFleece White EPDM membranes include " VersiFleece White EPDM 100", " VersiFleece White EPDM 115" and " VersiFleece White EPDM 145". The VersiFleece TPO membranes include "VersiFleece TPO 100", "VersiFleece TPO 115", "VersiFleece TPO 127" and "VersiFleece TPO 135". The VersiFleece FRS KEE HP membranes include "VersiFleece FRS KEE HP" 105, "VersiFleece FRS KEE HP" 115 and "VersiFleece FRS KEE HP" 135. The VersiFleece PVC membranes include "VersiFleece PVC" 105, "VersiFleece PVC" 115 and " VersiFleece PVC" 135. The VersiFleece FRS PVC membranes include " VersiFleece FRS PVC 105", VersiFleece FRS PVC 115" and "VersiFleece FRS PVC 135". The VersiFleece KEE HP membranes include "VersiFleece KEE HP 105", VersiFleece KEE HP 115" and "VersiFleece KEE HP 135".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 63/103 The membrane is adhered to an acceptable insulation or substrate with a two-component spray applied low-rise polyurethane foam adhesive. The coverage for "DASH", or "WeatherBond DASH" or "DASH Dual Tank Adhesive", or "WeatherBond DASH Dual Tank Adhesive", or "WeatherBond Flexible DASH", or "Flexible DASH" is approximately 100 ft2/gal. The addition of catalyst to the "DASH" and "Flexible DASH" may be required depending upon weather conditions. The membrane may also be adhered with "Aqua Base 120" at a rate of approximately 120 ft2/gal. "HydroBond Water-Based Adhesive" at a rate of approximately 100 ft2/gal. may be used as a Classified alternate to "Aqua Base 120". In any of the following systems, concrete decking, Georgia-Pacific Gypsum LLC "DensDeck® Overlayment Board" or SECUROCK Gypsum Fiber Roof Board may be primed with "CCW-702 Primer", "CCW-702LV Primer", "CCW CavGrip Primer" or "CCW-714 Primer" and optionally covered with "VapAir Seal 725TR". Unless otherwise indicated the "DASH Dual Tank Adhesive", "WeatherBond DASH Dual Tank Adhesive", "Flexible DASH" or "WeatherBond Flexible DASH" may be applied in 2 to 3-in. diameter beads spaced 12-in. on-center as an alternate to full coverage. "DASH DC Dual Cartridge Adhesive" or "DASH 5-Gallon Jug Adhesive" or "WeatherBond DASH 5-Gallon Jug Adhesive" may be used as an alternate to "Flexible DASH DC Dual Cartridge Adhesive" or "WeatherBond Flexible DASH Dual Cartridge Adhesive" or "Flexible DASH 5-Gallon Jug Adhesive" or "WeatherBond Flexible DASH 5-Gallon Jug Adhesive" may be used as an alternate to "Flexible DASH" or "WeatherBond Flexible DASH" in any of the following systems. 24. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — Carlisle SynTec Inc. "Sure-Seal FleeceBACK Membranes", adhered with "Flexible DASH" or "WeatherBond Flexible DASH" or "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 25. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness. Insulation: — Versico "Recovery Board" or minimum 1/2-in. thick wood fiberboard. Membrane: — "VersiFleece EPDM", adhered with "Flexible DASH" or "WeatherBond Flexible DASH" or "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 26. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece EPDM", adhered with "Flexible DASH" or "WeatherBond Flexible DASH", "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 27. Deck: NC Incline: 1/2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 64/103 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece White EPDM 100" or "VersiFleece White EPDM 115", adhered with "Flexible DASH", "WeatherBond Flexible DASH", "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 28. Deck: NC Incline: 1/2 Insulation: — Any UL Classified, any thickness. Insulation: — Versico "Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — VersiFleece White EPDM 100" or "VersiFleece White EPDM 115, adhered with "Flexible DASH", "WeatherBond Flexible DASH", "DASH Dual Tank Adhesive", "WeatherBond DASH Dual Tank Adhesive" 29. Deck: NC Incline: 1/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece TPO", adhered with "Flexible DASH", "WeatherBond Flexible DASH", "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 30. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness. Insulation: — Versico "Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece TPO", adhered with "Flexible DASH", "WeatherBond Flexible DASH", "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 31. Deck: C-15/32 Incline: 1-1/2 Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece TPO", adhered with "Flexible DASH", "WeatherBond Flexible DASH", "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 40. Deck: C-15/32 Incline: 1 Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece White EPDM 145", adhered with "Flexible DASH" or "WeatherBond Flexible DASH". Class B - Fully Adhered 'VersiFleece' 5. Deck: C-15/32 Incline: 1 Insulation (Optional): — Any UL Classified , any combination, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 65/103 Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — Carlisle SynTec Inc. "Sure-White FleeceBACK Membranes", adhered with "Flexible DASH", "WeatherBond Flexible DASH", "DASH Dual Tank Adhesive" or "WeatherBond DASH Dual Tank Adhesive". 3. Deck: NC Incline: 3/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece White EPDM 145", adhered with "DASH", or "WeatherBond DASH", or "Flexible DASH" or "WeatherBond Flexible DASH". 4. Deck: NC Incline: 1 Insulation: — Versico "Recovery Board", 1/2 to 3 in. thick; 1/2-in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiFleece White EPDM 145", adhered with "DASH", or "WeatherBond", or "Flexible DASH" or "WeatherBond Flexible DASH ". 5. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum 2-in. thick. Membrane: — "VersiFleece EPDM" or "VersiFleece TPO" or "Sure-Flex KEE HP FRS FleeceBACK" or "VersiFleece FRS PVC" or "VersiFleece PVC" adhered with "Flexible DASH" or "WeatherBond Flexible DASH". Class C - Adhered 'VersiFleece' 1. Deck: NC Incline: 2 Insulation: — Any Insulfoam EPS product, maximum 2 pcf density, any thickness. Membrane: — Any of the VersiFleece EPDM Membranes, VersiFleece White EPDM, VersiFleece TPO or WeatherBond TPO Membranes, VersiFleece PVC or WeatherBond PVC Membranes, VersiFleece FRS PVC or WeatherBond PVC FRS Membranes, VersiFleece KEE HP or WeatherBond KEE HP Membranes or "VersiFleece FRS KEE HP" or WeatherBond KEE HP FRS Membranes adhered with any DASH, Flexible DASH, XPAND or WeatherBond Flexible DASH product. Class A - Fully Adhered 'VersiFleece' with 'DASH' or "WeatherBond DASH" Adhesive - EPDM, PVC, TPO The "VersiFleece EPDM Membranes" family of membranes include "VersiFleece EPDM 100", "VersiFleece EPDM 115" and "VersiFleece EPDM 145". The "VersiFleece TPO Membranes" family of membranes include "VersiFleece TPO 100", "VersiFleece TPO 115" and "VersiFleece TPO 135". 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 66/103 The "VersiFleece PVC Membranes" family of membranes include "VersiFleece PVC 105", "VersiFleece PVC 115" and "VersiFleece PVC 135". The "VersiFleece FRS KEE HP" family of membranes include "VersiFleece KEE HP FRS 105", "VersiFleece KEE HP FRS 115" and "VersiFleece KEE HP FRS 135". The "VersiFleece FRS PVC" family of membranes" include "VersiFleece PVC FRS 105", VersiFleece PVC FRS 115" and "VersiFleece PVC FRS 135". The "VersiFleece KEE HP" family of membranes include "VersiFleece KEE HP 105", VersiFleece KEE HP 115" and "VersiFleece KEE HP 135". The membrane is fully adhered to an acceptable insulation or substrate with a two component spray applied low-rise polyurethane foam adhesive (DASH) or with "Aqua Base 120 Bonding Adhesive". The coverage for " DASH" or "WeatherBond DASH" is approximately 100-ft.2/gal. The addition of catalyst to "DASH" or "WeatherBond DASH" may be required depending upon weather conditions. The coverage rate for the "Aqua Base 120" is 120-ft.2/gal. "HydroBond Water-Based Adhesive" at a rate of approximately 100-ft2/gal. may be used as a Classified alternate to "Aqua Base 120". In any of the following systems, concrete decking or Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" barrier Board may be primed with "CCW-702 Primer" or "CCW-714 Primer" and optionally covered with "VapAir Seal 725TR". Unless otherwise indicated the "DASH" or "WeatherBond DASH" may be applied in 2 to 3-in. beads spaced 12-in. on-center maximum as an alternate to full coverage. "DASH Dual Cartridge Adhesive", "WeatherBond DASH Dual Cartridge Adhesive" or "WeatherBond DASH 5-Gallon Jug Adhesive" or "DASH 5-Gallon Jug Adhesive" or "WeatherBond Flexible DASH 5-Gallon Jug Adhesive" may be used as an alternate to "DASH" or "WeatherBond DASH". Unless otherwise noted, Insulfoam LLC "Insulfoam SP", minimum 1-in. thick, can be used in lieu of polyisocyanurate insulation in any of the following systems. 1. Deck: NC Incline: 1/2 Impact: 4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece EPDM 100, EPDM 115 or EPDM 145", adhered with "DASH" or "WeatherBond DASH" 2. Deck: NC Incline: 3/4 Impact: 4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece White EPDM 100, White EPDM 115 or White EPDM 145", adhered with "DASH" or "WeatherBond DASH". 3. Deck: NC Incline: 1/2 Impact: 4 Insulation: — Any UL Classified, any thickness. Insulation: — Versico Recovery Board or 1/2-in. thick (minimum) wood fiberboard.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 67/103 Membrane: — "VersiFleece EPDM 100, EPDM 115 or EPDM 145", adhered with "DASH" or "WeatherBond DASH". 4. Deck: NC Incline: 3/4 Impact: 4 Insulation: — Any UL Classified, any thickness. Insulation: — "Versico Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece White EPDM 100, White EPDM 115 or White EPDM 145", adhered with "DASH" or "WeatherBond DASH". 5. Deck: C-15/32 Incline: 3/4 Impact: 4 Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" or minimum 1/2-in. thick gypsum board. Foam: — Premium Polymers "241" or Stepan Chemical "9700", any thickness. Membrane: — "VersiFleece EPDM 100, White EPDM 100, EPDM 115 White EPDM 115, EPDM 145 or White EPDM 145", adhered with "DASH" or "WeatherBond DASH". 6. Deck: NC Incline: 3/4 Impact: 4 Foam: — Premium Polymers "241" or Stepan Chemical "9700", any thickness. Membrane: — "VersiFleece EPDM 100", "White EPDM 100", "EPDM 115" "White EPDM 115", "EPDM 145" or WhiteEPDM 145", adhered with "DASH" or "WeatherBond DASH". 7. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", fully adhered with "DASH" or "WeatherBond DASH". 8. Deck: NC Incline: 1-1/2 Insulation (Optional): — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2-in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in- place) concrete. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", fully adhered with "DASH" or "WeatherBond DASH". 9. Deck: NC Incline: 3 Insulation: — Any UL Classified, any thickness. Barrier Board: — minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" or minimum 1/2-in. thick gypsum wallboard. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", fully adhered with "DASH" or11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 68/103 "WeatherBond DASH". 10. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S" or three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. FleeceBACK membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 2:12. 10A. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM FleeceBACK membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 10B. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. EPDM FleeceBACK membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used, but cannot exceed 3/4:12 11. Deck: NC Incline: 1/4 Insulation: — "Polyiso MP-N", Hunter Panels "H-Shield ca" or Johns Manville "ENRGY3" any combination, any thickness. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", fully adhered with "DASH" or "WeatherBond DASH" adhesive. 12. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations" except "Polyiso MP-N", Hunter Panels "H- Shield ca" or Johns Manville "ENRGY3", any combination, any thickness. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", fully adhered with "DASH" or11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 69/103 "WeatherBond DASH" adhesive. 13. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness. Insulation: — "Versico Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", fully adhered with "DASH" or "WeatherBond DASH" adhesive. 14. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece EPDM 100, EPDM 115 or EPDM 145", fully adhered with "DASH" or "WeatherBond DASH" adhesive. 15. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness. Insulation: — "Versico Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece EPDM 100, EPDM 115 or EPDM 145", fully adhered with "DASH" or "WeatherBond DASH" adhesive. 16. Deck: NC Incline: 1 Membrane: — "VersiFleece EPDM 100, EPDM 115 or EPDM 145", fully adhered with "DASH" or "WeatherBond DASH" adhesive. 17. Deck: NC Incline: 1/2 Insulation: — "VersiFleece White EPDM 100, White EPDM 115 or White EPDM 145" adhered with "DASH" or "WeatherBond DASH" applied at 2 to 3-in. diameter beads spaced 12-in. On-Center maximum. Membrane: — "VersiFleece 100 White EPDM or 115 White EPDM Membrane" adhered with "DASH" or "WeatherBond DASH" applied at 2 to 3-in. diameter beads spaced 12-in. on-center maximum. 18. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness Insulation: — "Versico Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece 100 White EPDM or 115 White EPDM Membrane", adhered with "DASH" or "WeatherBond DASH" applied at 2 to 3-in. diameter beads spaced 12-in. on-center maximum. 19. Deck: C-15/32 Incline: 2 Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 70/103 Membrane: — "VersiFleece White EPDM 100, White EPDM 115 or White EPDM 145", adhered with "DASH" or "WeatherBond DASH" applied at 2 to 3-in. beads spaced 12-in. On-Center maximum. 20. Deck: NC Incline: 1 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece White EPDM 100, White EPDM 115 or White EPDM 145", adhered with "Aqua Base 120 Bonding Adhesive" at 120-ft2/gal. 21. Deck: NC Incline: 2-1/2 Insulation : — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece PVC" or "WeatherBond PVC Fleece". 22. Deck: NC Incline: 2-1/2 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — "Versico HP Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece PVC" or "WeatherBond PVC Fleece". 23. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Membrane: — "VersiFleece PVC". 24. Deck: NC Incline: 3/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece KEE HP FRS" or "WeatherBond KEE HP FRS Fleece". 25. Deck: NC Incline: 1-1/2 Insulation: — Any UL Classified, any thickness. Insulation: — Versico "Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece FRS KEE HP" or "WeatherBond KEE HP FRS Fleece". 26. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 71/103 "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Membrane: — "VersiFleece FRS KEE HP" or "WeatherBond KEE HP FRS Fleece". 27. Deck: NC Incline: 21/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece PVC", "WeatherBond PVC Fleece", VersiFleece PVC FRS" or "WeatherBond PVC FRS Fleece". 28. Deck: NC Incline: 21/2 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — Versico "Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece PVC", "WeatherBond PVC Fleece", VersiFleece PVC FRS" or "WeatherBond PVC FRS Fleece". 29. Deck: C-15/32 Incline: 3 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece PVC" or "WeatherBond PVC Fleece", VersiFleece PVC FRS" or "WeatherBond PVC FRS Fleece". 30. Deck: NC Incline: 1-1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece". 31. Deck: NC Incline: 2-1/2 Insulation: — Any UL Classified, any thickness. Insulation: — Versico "Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece". 32. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified , any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece". Class B - VersiFleece Fully Adhered with 'DASH' or "WeatherBond DASH" Adhesive - EPDM, PVC 1. Deck: NC Incline: 3 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 72/103 Membrane: — "Versiweld VersiFleece 100 or 115", fully adhered with "DASH" or "WeatherBond DASH" adhesive, 100-ft2/gal. 2. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. "EPDM FleeceBACK" membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum, but cannot exceed 1- 1/2:12 3. Deck: C-15/32 Incline: See Note Slip Sheet: — One layer "FR Base Sheet 1S" or Atlas Roofing Corp. "FR-10". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. PVC membrane. Note: Maximum incline shall be in accordance with Classification established for the membrane roof covering system applied over fiberboard or gypsum but cannot exceed 1/2:12. 4. Deck: C-15/32 Incline: 4 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece PVC" or "WeatherBond PVC Fleece". 5. Deck: C-15/32 Incline: 4 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece PVC", "WeatherBond PVC Fleece", "VersiFleece PVC FRS" or "WeatherBond PVC FRS Fleece". Class C - VersiFleece Adhered with "DASH" or "WeatherBond DASH" Adhesive - EPDM, PVC 1. Deck: NC Incline: 3/4 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece White EPDM 100 White EPDM 115 or White EPDM 145", adhered with "Aqua Base 120 Bonding Adhesive" at 120-ft2/gal. 2. Deck: C-15/32 Incline: Unlimited 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 73/103 Insulation: — See "Referenced Insulations", any combination, minimum 2-in. thickness. Membrane: — Any of the VersiFleece EPDM Membranes, VersiFleece TPO Membranes or VersiFleece PVC Membranes, "VersiFleece FRS KEE HP" or VersiFleece PVC FRS adhered with "DASH" or "WeatherBond DASH" or "Aqua Base 120 Bonding Adhesive". 3. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. VersiFleece membrane. Class A - VersiFleece AC-HM Fully Adhered with Hot Roofing Asphalt - EPDM, PVC The "VersiFleece FRS KEE HP" family of membranes include "VersiFleece KEE HP FRS 105", "VersiFleece KEE HP FRS 115" and "VersiFleece KEE FRS 135". The VersiFleece KEE HP membranes include "VersiFleece KEE HP 105", "VersiFleece KEE HP 115" and "VersiFleece KEE 135". Unless otherwise indicated, the "VersiFleece FRS KEE HP" or "VersiFleece KEE HP" membrane may be used as a Classified alternate to the Sure-Seal (EPDM) AFX membranes in any of the following systems. 1. Deck: NC Incline: 2 Insulation: — Any UL Classified, any thickness, covered with "Versico Recovery Board" or 1/2-in. (minimum) wood fiberboard. Membrane: — "VersiFleece AC EPDM 90 Membrane" or "VersiFleece AC EPDM 105 Membrane". 2. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation (Optional): — Any UL Classified (except EPS), any combination, any thickness, covered with "Versico Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC Membrane". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 2:12. 2A. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC EPDM Membrane". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 74/103 membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 2B. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC EPDM Membrane". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 3/4:12 3. Deck: NC Incline: 2 Slip Sheet: — One or more layers of the following - Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or VersaShield FB-2S" or Type G2 base sheet, hot mopped or mechanically fastened. Membrane: — "VersiFleece AC 90 EPDM Membrane" or "VersiFleece AC EPDM 105 Membrane". 4. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness, covered with "Versico Recovery Board" or 1/2-in. (minimum) wood fiberboard . Membrane: — "VersiFleece AC 120 TPO Membrane" or "VersiFleece AC 135 TPO Membrane". 5. Deck: NC Incline: 1 Slip Sheet: — One or more layers of the following - Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or VersaShield FB-2S" or Type G2 base sheet, hot mopped or mechanically fastened. Membrane: — "VersiFleece AC 120 TPO Membrane" or "VersiFleece AC 135 TPO Membrane". 6. Deck: C-15/32 Incline: See Note Slip Sheet (Optional): — One or more layers of Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment", "VersaShield FB-2S", Type G2 base sheet or unclassified slip sheet, hot mopped or mechanically fastened. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" or minimum 1/4-in. Owens-Corning "Strataguard" Slip Sheet: — One or more layers of Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment", "VersaShield FB-2S" or Type G2 base sheet, hot mopped or mechanically fastened. Insulation (Optional): — Any UL Classified (except EPS), any combination, any thickness, covered with "Versico Recovery Board" or minimum 1/2-in. thick wood11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 75/103 fiberboard, hot mopped or mechanically fastened. Membrane: — Any UL Classified "VersiFleece AC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 2:12. 7. Deck: NC Incline: 1 Insulation: — Lightweight insulating concrete. As an alternate, Versico Inc. UL Classified polyisocyanurate insulation, any combination, any thickness, covered with a minimum 1/2- in. thick of a UL Classified wood fiberboard or gypsum board. Slip Sheet: — One or more layers of the following - Versico Inc. "FR Base Sheet 2S", GAF "VersaShield Underlayment" or VersaShield FB-2S" or Type G2 base sheet or Type IV felt, any combination, hot mopped or mechanically fastened. Membrane: — VersiFleece AC TPO or WeatherBond TPO AC Fleece membranes. 8. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Insulation : — MonoBoard", "MonoBoard Plus", "MonoBoard Plus S", "TopRock DD", "TopRock DD Plus" or "TopRock DD Plus S", 3/4-in. minimum thick with joints staggered a minimum of 6-in. from the combustible roof deck butt joints. Membrane: — Any UL Classified VersiFleece AC EPDM membrane, hot mopped. 9. Deck: C-15/32 Incline: 1 Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Insulation : — MonoBoard", "MonoBoard Plus", "MonoBoard Plus S", "TopRock DD", "TopRock DD Plus" or "TopRock DD Plus S", 3/4-in. minimum thickness with joints staggered 6-in. from the combustible deck joints. Membrane: — Any UL Classified VersiFleece AC TPO or WeatherBond TPO AC Fleece membrane, hot mopped. 10. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board, minimum 1/4-in. thick Owens Corning "Strataguard", minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Glass-Mat Roof Board" (Type SGMRX) or "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with hot asphalt. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 76/103 11. Deck: NC Incline: 1 Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Base Sheet (Optional): — One or more plies of Type G2. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with hot asphalt. 12. Deck: NC Incline: 1/2 Insulation: — "Referenced Insulations", any combination, any thickness. Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with hot asphalt. 13. Deck: NC Incline: 2 Insulation (Optional): — "Referenced Insulations", any combination, any thickness. Barrier Board: — "Versico Recovery Board", 1/2 to 3 in. thick Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane"" or "WeatherBond TPO AC Fleece", adhered with hot asphalt. 14. Deck: NC Incline: 1/2 Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane"" or "WeatherBond TPO AC Fleece", adhered with hot asphalt. 15. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Insulation: — Roxul "MonoBoard", "MonoBoard Plus", "MonoBoard Plus S", "TopRock DD", "TopRock DD Plus" or "TopRock DD Plus S", 3/4-in. minimum thick with joints staggered 6 in. from the combustible deck joints. Membrane: — Any UL Classified "VersiFleece KEE HP FRS Membrane" or "VersiFleece KEE HP Membrane", hot mopped. 16. Deck: NC Incline: Unlimited 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 77/103 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — Any UL Classified "VersiFleece KEE HP FRS Membrane" or "VersiFleece KEE HP Membrane", hot mopped. 17. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board, minimum 1/4-in. thick Owens Corning "Strataguard", minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Glass-Mat Roof Board" (Type SGMRX) or "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece", adhered with hot asphalt. 18. Deck: NC Incline: 1 Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base" any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece", adhered with hot asphalt. 19. Deck: NC Incline: 1/2 Insulation: — "Referenced Insulations", any combination, any thickness. Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece", adhered with hot asphalt. 20. Deck: NC Incline: 2 Insulation (Optional): — "Referenced Insulations", any combination, any thickness. Insulation (Barrier Board): — Versico "Recovery Board, 1/2 to 3-in. thick Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 78/103 Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece", adhered with hot asphalt. 21. Deck: NC Incline: 1/2 Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base". Membrane: — "VersiFleece KEE HP " or "WeatherBond KEE HP Fleece", adhered with hot asphalt. Class B - VersiFleece AC-HM Fully Adhered with Hot Asphalt - EPDM 1. Deck: NC Incline: 1/2 Insulation: — See "referenced insulations", any combination, any thickness. Membrane: — "VersiFleece AC EPDM 90 Membrane" or "VersiFleece AC EPDM 105 Membrane", hot mopped. 2. Deck: C-15/32 Incline: 1/2 Slip sheet: — One layer Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S", hot mopped or mechanically fastened. Membrane: — Any UL Classified Versico Inc. VersiFleece AC membrane. Class C - VersiFleece AC-HM Fully Adhered with Hot Roofing Asphalt - EPDM 1. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. VersiFleece AC membrane. Class A - VersiFleece AC-Cold Applied Adhesive Adhered - EPDM, PVC, TPO The VersiFleece AC membranes are adhered with Versico Inc.'s "Cold Applied Adhesive" at a coverage rate of 45 to 70-ft.2/gal. Unless otherwise indicated, "VersiFleece FRS KEE HP", "VersiFleece KEE HP", "VersiFleece PVC FRS" or "VersiFleece PVC" membranes may be used as a Classified alternate to the "VersiFleece AC EPDM" membranes in any of the following systems. 1. Deck: NC Incline: 1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece AC EPDM 90 Membrane", "VersiFleece AC EPDM 105Membrane", "VersiFleece AC 120 TPO Membrane" or "VersiFleece AC 135 TPO Membrane".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 79/103 2. Deck: NC Incline: 1 Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board", 1/2- in. thick minimum, over any Classified insulation, any combination, any thickness; cellular concrete, precast concrete with grouted joints or structural (poured-in-place) concrete. Membrane: — "VersiFleece AC EPDM 90Membrane", "VersiFleece AC EPDM 105Membrane", "VersiFleece AC 120 TPO Membrane" or "VersiFleece AC 135 TPO Membrane". 3. Deck: C-15/32 Incline: 1-1/2 Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — "VersiFleece FRS KEE HP" or "VersiFleece AC EPDM 90 Membrane", "VersiFleece AC EPDM 105 Membrane", "VersiFleece AC 120 TPO Membrane" or "VersiFleece AC 135 TPO Membrane". 4. Deck: C-15/32 Incline: See Note Slip Sheet: — Two layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Insulation (Optional): — Any UL Classified (except EPS), any combination, any thickness, covered with "Versico Recovery Board" or 1/2-in. thick (minimum) wood fiberboard. Membrane: — Any UL Classified Versico Inc. VersiFleece AC membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 2:12. 5. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. VersiFleece AC EPDM membrane. Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used. 6. Deck: C-15/32 Incline: See Note Slip Sheet: — Three layers GAF "VersaShield FB-1S". Insulation (Optional): — Any UL Classified (except EPS and wood fiberboard), any combination, any thickness. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC EPDM Membrane".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 80/103 Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used, but cannot exceed 3/4:12 7. Deck: NC Incline: 2 Slip Sheet: — One or more layers of the following - "FR Base Sheet", GAF "VersaShield Underlayment" or VersaShield FB-2S" or Type G2 base sheet, hot mopped or mechanically fastened. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC EPDM Membrane". 8. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness, covered with "Versico Recovery Board' or 1/2-in. (minimum) wood fiberboard. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC TPO Membrane". 9. Deck: NC Incline: 1 Slip Sheet: — One or more layers of the following - Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or VersaShield FB-2S" or Type G2 base sheet, hot mopped or mechanically fastened. Membrane: — Any UL Classified Versico Inc. VersiFleece AC TPO or WeatherBond TPO AC Fleece membrane. 10. Deck: C-15/32 Incline: See Note Slip Sheet (Optional): — One or more layers of Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment", "VersaShield FB-2S", Type G2 base sheet or unclassified slip sheet, hot mopped or mechanically fastened. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". or minimum 1/4-in. thick Owens-Corning "Strataguard". Slip Sheet: — One or more layers of Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment", "VersaShield FB-2S" or Type G2 base sheet, hot mopped or mechanically fastened. Insulation (Optional): — Any UL Classified (except EPS), any combination, any thickness, covered with "Versico Recovery Board" or minimum 1/2-in. thick wood fiberboard, hot mopped or mechanically fastened. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC Membrane". Note: Maximum incline shall be in accordance with Classification established for the insulation/membrane roof covering system when insulation is used or established for the membrane roof covering system applied over fiberboard or gypsum when insulation is not used but cannot exceed 2:12. 11. Deck: NC Incline: Unlimited Insulation (Optional): — Any UL Classified, any combination, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 81/103 Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" Membrane: — Any UL Classified "VersiFleece PVC" or "WeatherBond PVC Fleece". 12. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board, minimum 1/4-in. thick Owens Corning "Strataguard", minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Glass-Mat Roof Board" (Type SGMRX) or "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with "Cold Applied Adhesive. 13. Deck: NC Incline: 1 Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane" or "VersiFleece AC TPO Membrane", adhered with "Cold Applied Adhesive 14. Deck: NC Incline: 1/2 Insulation: — "Referenced Insulations", any combination, any thickness. Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with "Cold Applied Adhesive. 15. Deck: NC Incline: 2 Insulation (Optional): — "Referenced Insulations", any combination, any thickness. Barrier Board: — "Versico Recovery Board', 1/2 to 3 in. thick Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with "Cold Applied Adhesive.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 82/103 16. Deck: NC Incline: 1/2 Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with "Cold Applied Adhesive". 17. Deck: NC Incline: Unlimited Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — Any UL Classified or "VersiFleece FRS KEE HP", VersiFleece KEE HP Membranes, VersiFleece PVC FRS or VersiFleece PVC Membrane. 18. Deck: C-15/32 Incline: 2 Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board, minimum 1/4-in. thick Owens Corning "Strataguard", minimum 1/4-in. thick United States Gypsum Co. "SECUROCK Glass-Mat Roof Board" (Type SGMRX) or "SECUROCK Gypsum-Fiber Roof Board" (Type FRX-G) or minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base" or "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece" adhered with "Cold Applied Adhesive". 19. Deck: NC Incline: 1 Base Sheet (Optional): — One or more plies of Type G2 Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece" adhered with "Cold Applied Adhesive". 20. Deck: NC Incline: 1/2 Insulation: — "Referenced Insulations", any combination, any thickness. Base Sheet (Optional): — One or more plies of Type G2.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 83/103 Ply Sheet: — One or more plies of "SureMB 90 Base", "SureMB 90TG Base" or "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece" adhered with "Cold Applied Adhesive". 21. Deck: NC Incline: 2 Insulation (Optional): — "Referenced Insulations", any combination, any thickness. Barrier Board: — Versico "Recovery Board", 1/2 to 3 in. thick Base Sheet (Optional): — One or more plies of Type G2. Ply Sheet: — One or more plies of "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece" adhered with "Cold Applied Adhesive". 22. Deck: NC Incline: 1/2 Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base" or "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Cap Sheet: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece" adhered with Carlisle "Cold Applied Adhesive". Class B - VersiFleece AC-Cold Applied Adhesive Adhered - EPDM Insulation: — See "referenced insulations", any combination, any thickness. 1. Deck: C-15/32 Incline: 1/2 Slip sheet: — One layer Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S", hot mopped or mechanically fastened. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC Membrane". Class C - VersiFleece AC-Cold Applied Adhesive Adhered - EPDM 1. Deck: C-15/32 Incline: 1 Insulation: — "Versico Recovery Board" or any UL Classified wood fiberboard, 1/2-in. thick minimum. Membrane: — Any UL Classified Versico Inc. "VersiFleece AC Membrane". Class A - VersiFleece - Mechanically Attached - PVC, TPO 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 84/103 1. Deck: NC Incline: 1/2 Insulation: — See: "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece TPO Membranes". 2. Deck: NC Incline: 1-1/2 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — 1/2-in. thick "Versico Recovery Board". Membrane: — "VersiFleece TPO Membranes". 3. Deck: NC Incline: 3 Insulation: — Any UL Classified, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — "VersiFleece TPO Membranes". 4. Deck: NC Incline: 2-1/2 Insulation: — See "Referenced Insulations", any combination, any thickness. Membrane: — "VersiFleece PVC Membranes", VersiFleece PVC FRS" or "WeatherBond PVC FRS Fleece". 5. Deck: NC Incline: 2-1/2 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — "Versico Recovery Board' or 1/2-in. thick (minimum) wood fiberboard. Membrane: — "VersiFleece PVC Membranes", VersiFleece PVC FRS" or "WeatherBond PVC FRS Fleece". 6. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". All butt joints staggered a minimum of 6-in. from the plywood deck joints. Membrane: — "VersiFleece PVC Membranes", VersiFleece PVC FRS" or "WeatherBond PVC FRS Fleece". 7. Deck: NC Incline: 1/2 Base Sheet — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 85/103 Membrane — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane", "WeatherBond TPO AC Fleece" or VersiFleece PVC Membranes, mechanically fastened. 8. Deck: NC Incline: 1/2 Base Sheet — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Membrane — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece" or "VersiFleece PVC Membranes". Class C - FleeceBACK-Mechanically Attached - EPDM, PVC, TPO 1. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum, 2-in. thick. Membrane: — Any of the VersiFleece EPDM, TPO or PVC Membranes. 2. Deck: C-15/32 Incline: Unlimited Insulation: — See "Referenced Insulations", any combination, minimum, 2-in. thick. Membrane: — Any of the "VersiFleece EPDM" Membranes, "VersiFleece TPO" Membranes, "VersiFleece KEE HP" Membranes or "VersiFleece FRS KEE HP" Membranes. 3. Deck: NC Incline: 2 Insulation: — Any Insulfoam EPS product, maximum 2 pcf density, any thickness. Membrane: — Any of the VersiFleece EPDM Membranes, VersiFleece White EPDM, VersiFleece TPO or WeatherBond TPO Membranes, VersiFleece PVC or WeatherBond PVC Membranes, VersiFleece PVC FRS or WeatherBond PVC FRS Membranes, VersiFleece KEE HP or WeatherBond KEE HP Membranes or "VersiFleece FRS KEE HP" or WeatherBond KEE HP FRS Membranes. MAINTENANCE AND REPAIR SYSTEMS Class A, B and C 1. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced non-modified asphalt coated cap sheet roof covering system, to retain the existing Classification, is covered with: Membrane: — "VersiGard EPDM" or "VersiGard White EPDM VersiGard" 0.045 or 0.060- in., fully adhered. 2. Deck: C-15/32 Incline: 1/2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 86/103 Existing Roof System: — Class A, B or C mineral or smooth surfaced non-modified asphalt coated cap sheet roof covering system, to retain the existing Classification, is covered with: Slip Sheet (Optional): — One or more layers of the following - Lydall "Manniglas 1200" mat, 15-mil, Atlas Roofing Corp. "FR-10", GAF "VersaShield", Versico Inc. "FR Base Sheet" or Type G2 base sheet, laid loosely. Membrane: — "VersiGard FR Reinforced EPDM", "WeatherBond FR Reinforced EPDM" or "VersiGard Reinforced EPDM Membrane", mechanically fastened. 3. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system, to retain the existing Classification, is covered with: Membrane: — "VersiGard EPDM", "VersiGard White EPDM VersiGard".045 or .060-in., "VersiFleece AC EPDM 90 Membrane" or "VersiFleece AC EPDM 105 Membrane", fully adhered. 4. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system, to retain the existing Classification, covered with: Membrane: — "VersiFleece EPDM Membrane", "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", fully adhered with "DASH", "WeatherBond DASH", "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive"; or "VersiFleece AC EPDM 90 Membrane" or "VersiFleece AC EPDM 105 Membrane", hot mopped. 5. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Slip Sheet: — One or more layers of the following - Lydall "Manniglas 1200" mat, 15-mil, Atlas Roofing Corp. "FR-10", GAF "Versashield", Versico Inc. "FR Base Sheet" or Type G2 base sheet, laid loosely. Membrane: — "VersiWeld TPO" or "WeatherBond TPO", "VersiWeld Plus TPO", "WeatherBond TPO Plus" or "VersiFlex PVC", mechanically fastened. 6. Deck: C-15/32 Incline: 3/4 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Slip Sheet: — One or more layers of the following - Lydall "Manniglas 1200" mat, 15-mil, Atlas Roofing Corp. "FR-10", GAF "Versashield", Versico Inc. "FR Base Sheet" or Type G2 base sheet, laid loosely. Membrane: — "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO", "WeatherBond HS Plus TPO", "VersiFlex PVC" or "WeatherBond PVC", mechanically fastened. 7. Deck: C-15/32 or NC Incline: 1 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 87/103 Existing Roof System: — Class A, B or C roof covering, gravel to be maintained on gravel built-up system, to retain the existing Classification, is cover with: Insulation: — Owens Corning Specialty & Foam Products "Durapink", 1-in. thick maximum. Membrane: — Any Classified Versico Inc. mechanically attached assembly. 8. Deck: C-15/32 Incline: See Note Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Slip Sheet (Optional): — One or more layers Versico Inc. "FR Base Sheet", GAF "VersaShield Underlayment" or "VersaShield FB-2S". Membrane: — Any UL Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with Classification established for the existing roof covering system but cannot exceed 1-1/2:12. 9. Deck: C-15/32 Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece EPDM 100 EPDM 115 or EPDM 145", "VersiFleece PVC" or "WeatherBond PVC Fleece", adhered with "DASH", "WeatherBond DASH", "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive". Note: Maximum incline shall be in accordance with Classification established for the existing roof covering system but cannot exceed 2:12. 10. Deck: C-15/32 Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135" or "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", VersiFleece White EPDM 100 White EPDM 115 or White EPDM 145" "VersiFleece PVC" or "WeatherBond PVC Fleece", adhered with "DASH" or "WeatherBond DASH". Note: Maximum incline shall be in accordance with Classification established for the existing roof covering system but cannot exceed 1:12. 11. Deck: C-15/32 Incline: 1 Existing Roof System: — Class A, B or C mineral or smooth surfaced non-modified asphalt coated cap sheet roof covering system, retain the existing Classification, covered with: Membrane: — "VersiFleece EPDM 100 EPDM 115 or EPDM 145 ", "VersiFleece PVC" or "WeatherBond PVC Fleece", adhered with "DASH" or "WeatherBond DASH", or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive". 12. Deck: C-15/32 Incline: 1 Existing Roof System: — (To maintain existing Classification) Any Class A, B or C coated or uncoated, insulated or uninsulated, Type G3 mineral surfaced cap sheet, BUR or modified bitumen membrane roof covering system covered with:11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 88/103 Membrane: — "VersiFleece AC EPDM 90 Membrane", "VersiFleece AC EPDM 105", "VersiFleece AC 120 TPO Membrane", "VersiFleece AC 135 TPO Membrane", "VersiFleece PVC Membrane" or "WeatherBond PVC Fleece", mechanically fastened. 13. Deck: C-15/32 Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — Any UL Classified Versico Inc. VersiFleece AC membrane or "VersiFleece PVC Membranes", adhered with "Cold Applied Adhesive". Note: Maximum incline shall be in accordance with Classification established for the existing roof covering system but cannot exceed 1:12. 14. Deck: C-15/32 Incline: 1-1/2 Existing Roof System: — Class A, B or C insulated or uninsulated smooth surface BUR roof covering system to maintain existing rating. Joint Treatment (Optional): — All mechanical fasteners and any vertical seams with a gap in excess of 1/16-in. shall be treated with an acrylic or single package urethane caulk. After the caulk has set, a 4 to 12-in. wide, 15 to 20-mil pass of "Versico X-Tenda Coating" shall be applied over the center of each caulk bead. Base Coat: — One application "Versico X-Tenda Coating," applied at 1-gal/100-ft 2. Surfacing: — One or two applications "Versico X-Tenda Coating" applied at 1-gal/100- ft2/application. 15. Deck: NC Incline: 21/2 Existing Roof System: — Class A, B or C insulated or uninsulated smooth surface BUR (excludes modified bitumen) roof covering system to maintain existing rating. Joint Treatment (Optional): — All mechanical fasteners and any vertical seams with a gap in excess of 1/16-in. shall be treated with an acrylic or single package urethane caulk. After the caulk has set, a 4 to 12-in. wide, 15 to 20-mil pass of "Versico X-Tenda Coating" coating shall be applied over the center of each caulk bead. Base Coat: — One application "Versico X-Tenda Coating" applied at 1-gal./100-ft 2. Surfacing: — Two applications "Versico X-Tenda Coating" applied at 1-gal./100- ft2/application. 16. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Base Coat: — One or more layers Versico Inc. "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", any combination, mechanically fastened or hot mopped. Membrane: — "VersiFleece AC EPDM Membranes", hot mopped or "VersiFleece AC EPDM Membranes" or 'VersiFleece PVC" mechanically fastened. 17. Deck: NC Incline: 1/2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 89/103 Existing Roof System: — Class A, B or C built-up or modified bitumen roof covering system, (smooth surface, cap sheet or gravel surfaced with gravel maintained). Or Class A, B or C single-ply system (polystyrene in existing single-ply system must be below a cover board or minimum 1-in. thickness of polyisocyanurate), to retain the existing Classification. Insulation: — Insulfoam "R-TECH" Type "I", "VIII", "II", "IX" or "FanFold" l-in. maximum thickness. Membrane: — Mechanically fastened one of the following UL Classified Versico Inc. membranes: PVC, EPDM or TPO. 18. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C built-up roof covering system, smooth surface, cap sheet or gravel surfaced (gravel maintained) to retain the existing Classification. Insulation: — Insulfoam "R-TECH" Type "I", "VIII", "II", "IX", "FanFold" or "Insulfoam" Type "I", "VIII", "II", "IX", 1 in. maximum thickness. Membrane: — Any UL Classified Versico Inc. PVC, TPO or EPDM membrane, mechanically attached. EPDM must be Classified for use in an adhered or mechanically fastened application. 19. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification is covered with: Base Sheet: — One or more layers Versico Inc. "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Membrane: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with hot asphalt; or "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane", "WeatherBond TPO AC Fleece" or VersiFleece PVC Membranes, mechanically fastened. 20. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Base Sheet: — One or more layers Versico Inc. "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. Membrane: — "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", adhered with "Cold Applied Adhesive"; or "VersiFleece AC EPDM Membrane", "VersiFleece AC TPO Membrane", "WeatherBond TPO AC Fleece" or VersiFleece PVC Membranes, mechanically fastened. 21. Deck: C-15/32 Incline: 1/2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 90/103 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system to retain the existing Classification, covered with: Membrane: — "VersiFleece PVC Membranes", "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece KEE HP" "WeatherBond KEE HP Fleece" or "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", adhered with "DASH", or "WeatherBond DASH" or " Flexible DASH", "WeatherBond Flexible DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive"; "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece", hot mopped. 22. Deck: C-15/32 Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece PVC Membranes", "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece" or "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", adhered "DASH", or "WeatherBond DASH" or "Flexible DASH" or "WeatherBond Flexible DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive". Note: Maximum incline shall be in accordance with Classification established for the existing roof covering system but cannot exceed 2:12. 23. Deck: C-15/32 Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes" adhered with "DASH" or "WeatherBond DASH". Note: Maximum incline shall be in accordance with Classification established for the existing roof covering system but cannot exceed 1:12. 24. Deck: C-15/32 Incline: 1 Existing Roof System: — Class A, B or C mineral or smooth surfaced non-modified asphalt coated cap sheet roof covering system, retain the existing Classification, covered with: Membrane: — "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS KEE", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes" adhered with "DASH ", "WeatherBond DASH", "Flexible DASH" or "WeatherBond Flexible DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive". 25. Deck: C-15/32 Incline: 1 Existing Roof System: — (To maintain existing Classification) Any Class A, B or C coated or uncoated, insulated or uninsulated, Type G3 mineral surfaced cap sheet, BUR or modified bitumen membrane roof covering system covered with: Membrane: — "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece" or "VersiFleece PVC Membranes", mechanically fastened.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 91/103 26. Deck: C-15/32 Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — Any UL Classified AFX membrane, "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece PVC FRS ", "WeatherBond PVC FRS Fleece" or "VersiFleece PVC Membranes", adhered with "Cold Process Adhesive". Note: Maximum incline shall be in accordance with Classification established for the existing roof covering system but cannot exceed 1:12. 27. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base", "SureMB 120TG Base", "SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base" or "SureMB 120 HP Poly Base", any combination. Membrane: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece", adhered with hot asphalt; "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece" or "VersiFleece PVC Membranes", mechanically fastened. 28. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", "SureMB 90 Base", "SureMB 90TG Base" or "SureMB 120TG Base","SureMB 90 Poly Base", "SureMB 120 Poly Base", "SureMB 120TG Poly Base", "SureMB 120 HP Poly Base" or "SureMB 180S APP", any combination. any combination. Membrane: — "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS KEE HP" or "WeatherBond KEE HP FRS Fleece", adhered with "Cold Applied Adhesive"; "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece FRS KEE HP" , "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes", mechanically fastened. 29. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system, to retain the existing Classification, covered with: Membrane: — "VersiFleece EPDM", "VersiFleece PVC", "VersiFleece FRS PVC", "Sure- Flex KEE HP FleeceBACK Membranes" or "VersiFleece FRS KEE HP", adhered with "Flexible DASH" or "WeatherBond Flexible DASH", hot mopped. 30. Deck: C-15/32 Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, covered with:11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 92/103 Membrane: — "VersiFleece EPDM", "VersiFleece PVC", "VersiFleece FRS PVC", "Sure- Flex KEE HP FleeceBACK Membranes" or "VersiFleece FRS KEE HP", adhered "Flexible DASH" or "WeatherBond Flexible DASH". 31. Deck: C-15/32 Incline: 1 Existing Roof System: — Class A, B or C mineral or smooth surfaced non-modified asphalt coated cap sheet roof covering system, retain the existing Classification, covered with: Membrane: — "VersiFleece EPDM", "VersiFleece FRS KEE HP", "Sure-Flex KEE HP FleeceBACK Membranes", "VersiFleece FRS PVC" or "VersiFleece PVC" adhered with "Flexible DASH" or "WeatherBond Flexible DASH". 32. Deck: C-15/32 or NC Incline: See Note Existing Roof System: — Any Class A, B or C roof covering system, to retain the existing Classification, is covered with: Insulation: — "SecurShield HD NH", "WeatherBond XFP HD NH Cover Board", "SecurShield HD Plus NH" or "WeatherBond XFP HD Plus NH Cover Board" or Hunter Panels "H-Shield HD", "H-Shield HD90", "H-Shield HD Composite" Membrane: — Any UL Classified membrane. Note: Maximum incline shall be in accordance with Classification established for insulation/membrane roof covering system but cannot exceed 2:12. TPO membranes are limited to a maximum incline of 1/2:12. Class A 1. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, is covered with: Barrier Board: — Minimum 1/2-in. thick gypsum board. Membrane: — "VersiGard FR Reinforced EPDM", "WeatherBond FR Reinforced EPDM" or "VersiGard Reinforced EPDM Membrane", 45 to 75-mil, mechanically fastened. 2. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C roof covering system, gravel may be removed on gravel built-up system. Insulation: — Owens Corning Specialty & Foam Products "Fan-Fold", one layer or "Durapink", 1-in. thick maximum, mechanically fastened. Slip Sheet (Optional): — Lydall "Manniglas 1200", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM", 45 to 60-mil. 3. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C roof covering system, gravel may be removed on gravel built-up system. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 93/103 Insulation: — Owens Corning Specialty & Foam Products "Fan-Fold", one layer or "Durapink", 1-in. thick maximum, mechanically fastened. Ply Sheet: — One or more plies Type G2, Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil. 4. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system covered with: Membrane: — "VersiGard EPDM", "VersiGard White EPDM VersiGard", "VersiGard FR EPDM, "VersiGard" or "WeatherBond FR EPDM", "VersiFleece AC EPDM 90 Membrane", "VersiFleece AC EPDM 105 Membrane" or "VersiFleece PVC Membrane, fully adhered. 5. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system covered with: Membrane: — "VersiFleece EPDM Membrane", "VersiFleece PVC" or "WeatherBond PVC Fleece", fully adhered with "DASH", "WeatherBond DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive" or "VersiFleece AC EPDM 90 Membrane" or "VersiFleece AC EPDM 105 Membrane", hot mopped. 6. Deck: C-15/32 Incline: 1/4 Existing Roof System: — Class A, roof covering system gravel maintained on gravel built-up system, covered with: Insulation: — Tenneco "AMOCOR®-PB6, PG38 or PG39". Membrane: — "VersiWeld TPO" or "WeatherBond TPO", "VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO", "WeatherBond HS Plus TPO", "VersiWeld Plus TPO", "WeatherBond TPO Plus" "VersiFlex PVC" or "WeatherBond PVC", mechanically fastened. 7. Deck: NC Incline: 1/4 Existing Roof System: — Class A, B or C roof covering (gravel may be removed from gravel built-up system). Insulation: — Tenneco "AMOCOR®-PB6, PB6W, PG38 or PG39", mechanically fastened. Slip Sheet: — One layer Atlas Roofing Corp. "FR 10", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — ""VersiWeld HS TPO", "WeatherBond HS TPO", "VersiWeld HS Plus TPO", "WeatherBond HS Plus TPO", "VersiFlex PVC" or "WeatherBond PVC", mechanically fastened. 8. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up system). Insulation: — Tenneco "AMOCOR®-PB6, PB6W, PG38 or PG39", mechanically fastened. 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 94/103 Membrane: — "VersiGard FR Reinforced EPDM" or "WeatherBond FR Reinforced EPDM" membrane, mechanically fastened. 9. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C roof covering system, to retain the existing Classification, is covered with: Slip Sheet: — Two or more layers Atlas Roofing Corp. "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — Any Classified Versico Inc. mechanically attached assembly. 10. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C BUR or modified bitumen roof covering system gravel may be removed, covered with: Insulation (Optional): — See "Referenced Insulations", any combination, any thickness. Insulation (Optional): — 1/2-in. thick "Versico Recovery Board". Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135", "WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135", "VersiFleece PVC" or "WeatherBond PVC Fleece", mechanically attached or fully adhered with "DASH" or "WeatherBond DASH". 11. Deck: NC Incline: 2 Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece EPDM 100 EPDM 115 or EPDM 145", "VersiFleece PVC" or "WeatherBond PVC Fleece", adhered with "DASH" or "WeatherBond DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive". 12. Deck: NC Incline: 1 Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece TPO 100, TPO 115 or TPO 135","WeatherBond TPO Fleece 100, TPO Fleece 115 or TPO Fleece 135" or "VersiFleece EPDM 100 EPDM 115 or EPDM 145", adhered with "DASH" or "WeatherBond DASH". 13. Deck: NC Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 3 in. thick layer or minimum two layers of 1.5-in. thick Versico Inc. "SecurShield" or "SecurShield HD Composite" or Hunter Panels "H-Shield-CG", "H- Shield HD Composite" or "H-Shield HD Composite CG". Membrane: — Any Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with the Class A Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 14. Deck: C-15/32 Incline: See Note 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 95/103 Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 3 in. thick layer or minimum two layers of 1.5-in. thick Versico Inc. "SecurShield" or "SecurShield HD" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG". Membrane: — Any Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with the Class A Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 15. Deck: C-15/32 Incline: 2 Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up system). Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Insulation: — Roxul "MonoBoard", "MonoBoard Plus", "MonoBoard Plus S", "TopRock DD", "TopRock DD Plus" or "TopRock DD Plus S", 3/4-in. thick minimum. Membrane: — Any UL Classified VersiFleece AC EPDM Membrane, "VersiFleece PVC" or "WeatherBond PVC Fleece", hot mopped. 16. Deck: C-15/32 Incline: 1 Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up system). Insulation (Optional): — Any UL Classified insulation, any combination, any thickness. Insulation: — Roxul "MonoBoard", "MonoBoard Plus", "MonoBoard Plus S", "TopRock DD", "TopRock DD Plus" or "TopRock DD Plus S", 3/4-in. minimum thick. Membrane: — Any UL Classified "VersiFleece AC TPO" or "WeatherBond TPO AC Fleece Membrane", hot mopped. 17. Deck: NC Incline: 1 Existing Roof System: — Any UL Classified, any thickness or combination, covered with "Versico Recovery Board", 1/2-in. thick (minimum) wood fiberboard or gypsum board. Base Sheet: — One or more layers Versico Inc. "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", any combination, mechanically fastened or hot mopped. Membrane: — VersiFleece AC EPDM membranes, hot mopped; or VersiFleece AC EPDM, "VersiFleece PVC" or "WeatherBond PVC Fleece", mechanically fastened. Membrane: — Any UL Classified "VersiFleece AC TPO Membrane" or "WeatherBond TPO AC Fleece", hot mopped. 18. Deck: NC Incline: Unlimited Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up system). Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 96/103 Membrane: — Any UL Classified "VersiFleece PVC" or "WeatherBond PVC Fleece" adhered with "Cold Applied Adhesive". 19. Deck: C-15/32 Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 2.5-in. thick layer or minimum two layers of Versico Inc. "SecurShield" or "SecurShield HD" or Hunter "H-Shield-CG", H-Shield HD Composite" or "H-Shield HD Composite CG" over a minimum 2.5 in. thick layer of any UL Classified insulation (except expanded or extruded polystyrene). Membrane: — Any UL Classified roof covering membrane. Note: Maximum incline shall be in accordance with the Class A Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 20. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system covered with: Membrane: — "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes", adhered. 21. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system covered with: Membrane: — "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes" adhered, with "DASH" or "WeatherBond DASH" or "Flexible DASH" or "WeatherBond Flexible DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive"; hot mopped. 22. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system covered with: Membrane: — "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece", "VersiFleece PVC FRS", "WeatherBond PVC FRS Fleece", "VersiFleece PVC Membranes" or "VersiFleece EPDM", adhered, with "DASH" or "WeatherBond DASH" or "Flexible DASH" or "WeatherBond Flexible DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive"; "Sure-Seal AFX Membranes", "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS KEE HP" or "WeatherBond KEE HP FRS Fleece", hot mopped. 23. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C BUR or modified bitumen roof covering system gravel may be removed, covered with: Insulation (Optional): — See "Referenced Insulations", any combination, any thickness.11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 97/103 Insulation (Optional): — 1/2-in. thick "Versico "Recovery Board". Membrane: — "VersiFleece KEE HP" "WeatherBond KEE HP Fleece", " VersiFleece FRS PVC", "WeatherBond PVC FRS Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes", mechanically attached or adhered "DASH" or "WeatherBond DASH". 24. Deck: NC Incline: 2 Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS PVC", "WeatherBond PVC FRS Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes", adhered with "DASH" or "WeatherBond DASH" or "Flexible DASH" or "WeatherBond Flexible DASH" or "Aqua Base 120 Bonding Adhesive" or "HydroBond Water-Based Adhesive". 25. Deck: C-15/32 Incline: 2 Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up system). Insulation (Optional): — Any UL Classified insulation, any combination, any thick. Insulation: — Roxul "MonoBoard", "MonoBoard Plus", "MonoBoard Plus S", "TopRock DD", "TopRock DD Plus" or "TopRock DD Plus S", 3/4-in. minimum thickness. Membrane: — Any UL Classified Sure-Seal AFX Membrane "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS KEE HP" or "WeatherBond KEE HP FRS Fleece", hot mopped. 26. Deck: NC Incline: 1 Existing Roof System: — Any UL Classified, any thickness or combination, covered with Versico "Recovery Board", 1/2-in. thick (minimum) wood fiberboard or gypsum board. Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", "Type IV Glass Ply Felt", "Type VI Glass Ply Felt", any combination, mechanically fastened or hot mopped. Membrane: — "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS KEE HP" or "WeatherBond KEE HP FRS Fleece", hot mopped or "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS PVC" or "WeatherBond PVC FRS Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes", mechanically fastened. 27. Deck: NC Incline: Unlimited Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up system). Insulation (Optional): — Any UL Classified, any combination, any thickness. Barrier Board: — Minimum 1/2-in. thick gypsum board or minimum 1/4-in. thick Georgia- Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard". Membrane: — Any UL Classified "VersiFleece FRS KEE HP Membrane", "VersiFleece KEE HP" or "WeatherBond KEE HP Fleece" adhered with "Hot Asphalt" or "Cold Process Adhesive".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 98/103 Class A 28. Deck: NC Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 3-in. thick layer or minimum two 1.5-in. thick layers of "SecurShield NH", "WeatherBond XFP NH", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield-CG", H-Shield HD Composite" or "H-Shield HD Composite CG". Membrane: — Any UL Classified roof covering membrane. Note: The maximum incline shall be in accordance with the Class A Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 29. Deck: C-15/32 Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 3-in. thick layer or minimum two 1.5-in. thick layers of "SecurShield NH", "WeatherBond XFP NH", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite", "H-Shield HD Composite CG". Membrane: — Any UL Classified roof covering membrane. Note: The maximum incline shall be in accordance with the Class A Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 30. Deck: C-15/32 Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 2.5 in. thick layer or minimum two 1.5 in. thick layers of "SecurShield NH", "WeatherBond XFP NH", "SecurShield HD Composite NH" or "WeatherBond XFP HD Composite NH" or Hunter Panels "H-Shield-CG", H-Shield HD Composite", "H-Shield HD Composite CG" applied over a minimum 2.5-in. thick layer of any UL Classified insulation (except expanded or extruded polystyrene). Membrane: — Any UL Classified roof covering membrane. Note: The maximum incline shall be in accordance with the Class A Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. Class B 1. Deck: NC Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 1.9 in. thick layer of "SecurShield NH" or "WeatherBond XFP NH" or Hunter "H-Shield-CG"11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 99/103 Membrane: — Any UL Classified roof covering membrane. Note: The maximum incline shall be in accordance with the Class B Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 2. Deck: C-15/32 Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 1.9 in. thick layer of "SecurShield NH" or "WeatherBond XFP NH" or Hunter "H-Shield-CG" Membrane: — Any UL Classified roof covering membrane. Note: The maximum incline shall be in accordance with the Class B Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. Class A (PVC) 1. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A gravel surfaced B-U-R (gravel to be maintained). Insulation (Optional): — Polystyrene, any thickness. Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" mechanically fastened. Membrane: — "VersiFleece E PVC" mechanically fastened. 4. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A, B or C cap sheet or smooth surfaced BUR roof, insulated or uninsulated and/or single ply membrane (EPDM, PVC or CPE). Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard™ Roofboard" mechanically fastened. Membrane: — "VersiFleece FRS KEE Membrane", fully adhered with hot roofing asphalt or fully adhered with Flex Membrane International Corp. "Flex Substrate Adhesive" applied at a rate of 60-ft.2/gal. or "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" mechanically fastened. 5. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B, C cap sheet or smooth surfaced BUR roof, insulated or uninsulated and/or single ply membrane (EPDM, PVC or CPE). Insulation: — Any UL Classified polystyrene insulation, any thickness covered with Apache Products "Pyrox Whiteline", 1-in. thick minimum. Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" mechanically fastened. 6. Deck: NC Incline: 1/2 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 100/103 Existing Roof System: — Class A cap sheet or smooth surfaced BUR system (insulated or uninsulated) covered with: Slip Sheet: — Flex Membrane International Corp. "Flex FR-10" or Atlas Roofing Corp. "FR-10". Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" mechanically fastened. 7. Deck: NC Incline: 1/4 Existing Roof System: — Class A, B, C cap sheet or smooth surfaced BUR roof, insulated or uninsulated and/or single ply membrane (EPDM, PVC or CPE). Insulation: — Any UL Classified polystyrene insulation, any thickness covered with Dow Chemical "Hy-Tec" (Energy Lok), 1-in. thick minimum. Membrane: — "VersiFleece E PVC" or "VersiFleece FRS KEE Membrane" mechanically fastened. 8. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A B-U-R (gravel maintained) covered with: Insulation: — Wood fiberboard (1-in. or 2-layers 1/2-in. thick) mechanically fastened. Membrane: — "VersiFleece E PVC" mechanically fastened. Class B 1. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class A or B roof covering system covered with: Insulation: — "Versico Recovery Board", 1/2 to 3-in. thick; "Versico Recovery Board" over any Classified insulation, any combination, any thickness. Membrane: — "VersiGard EPDM", 0.045 or 0.060 in., "VersiGard White EPDM VersiGard", fully adhered. Also, "VersiGard FR Reinforced EPDM", "WeatherBond FR Reinforced EPDM" or "VersiGard Reinforced EPDM Membrane", may be mechanically fastened. 2. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class B mineral or smooth surfaced built-up or modified roof covering system, to retain the existing Classification, is covered with: Slip Sheet: — One or more layers Atlas Roofing Corp. "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — Any Classified Versico Inc. mechanically attached assembly. 3. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C roof covering system covered with: Membrane: — "VersiFleece AC 120 TPO Membrane" or "VersiFleece AC 135 TPO Membrane". 4. Deck: C-15/32 Incline: 1 11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 101/103 Existing Roof System: — Class A or B roof covering system covered with: Membrane: — Any UL Classified VersiFleece AC membrane, "VersiFleece PVC" or "WeatherBond PVC Fleece". 5. Deck: NC Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 1.9-in. thick layer of Versico Inc. "SecurShield" or "SecurShield HD Composite" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG". Membrane: — Any Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with the Class B Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 6. Deck: C-15/32 Incline: See Note Existing Roof System: — Class A, B or C roof covering system (gravel may be removed from gravel built-up or ballasted single-ply system). Insulation: — A minimum 1.9-in. thick layer of Versico Inc. "SecurShield" or "SecurShield HD Composite" or Hunter Panels "H-Shield-CG", "H-Shield HD Composite" or "H-Shield HD Composite CG". Membrane: — Any Classified Versico Inc. membrane. Note: Maximum incline shall be in accordance with the Class B Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. 7. Deck: C-15/32 Incline: 1 Existing Roof System: — Class A or B roof covering system covered with: Membrane: — Any UL Classified AFX membrane, "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS PVC", "WeatherBond PVC FRS Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC 5. Deck: NC Incline: 1/2 Existing Roof System: — Class A, B or C mineral or smooth surfaced cap sheet roof covering system covered with: Membrane: — —"VersiFleece EPDM", "Sure-Flex KEE HP FleeceBACK Membranes", "VersiFleece FRS KEE HP", "VersiFleece FRS PVC" or "VersiFleece PVC adhered, with "Flexible DASH" or "WeatherBond Flexible DASH" hot mopped. 11. Deck: NC Incline: 2 Existing Roof System: — Any Class A, B or C roof covering system, covered with: Membrane: — "VersiFleece EPDM", "Sure-Flex KEE HP FleeceBACK Membranes", "VersiFleece FRS KEE HP, "VersiFleece FRS PVC" or "VersiFleece PVC", adhered with "Flexible DASH" or "WeatherBond Flexible DASH".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 102/103 Class B and C 1. Deck: C-15/32 Incline: 1/2 Existing Roof System: — Class B or C roof covering system, to retain the existing Classification, is covered with: Slip Sheet: — One or more layers Atlas Roofing Corp. "FR-50", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — Any Classified Versico Inc. mechanically attached assembly. Class C 1. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C roof covering system, covered with: Insulation: — "Versico Recovery Board, 1/2 to 3-in. thick Membrane: — "VersiGardEPDM", 45 to 60-mil membrane fully adhered. 2. Deck: NC Incline: 1 Existing Roof System: — Class A, B or C roof covering system, gravel may be removed from gravel built-up system. Insulation: — Owens Corning Specialty & Foam Products "Fan-Fold", one layer or "Durapink", 1-in. maximum, mechanically fastened. Slip Sheet (Optional): — "Manniglas 1200", Versico Inc. "FR Base Sheet" or GAF "VersaShield Underlayment" or "VersaShield FB-2S. Membrane: — "VersiGard Reinforced EPDM Membrane", 45 to 75-mil. 3. Deck: C-15/32 Incline: 1 Existing Roof System: — Class C roof covering system covered with: Membrane: — Any UL Classified "VersiFleece AC membrane", "VersiFleece PVC" or "WeatherBond PVC Fleece". 4. Deck: C-15/32 Incline: 1 Existing Roof System: — Class C roof covering system covered with: Base Sheet: — One or more layers "Modified Base Sheet", "28 pound G2 Base Sheet", Type IV Glass Ply Felt", "Type VI Glass Ply Felt", any combination, mechanically fastened or hot mopped. Membrane: — "VersiFleece AC TPO Membranes" or "WeatherBond TPO AC Fleece" mechanically fastened or hot mopped. 5. Deck: C-15/32 Incline: 1 Existing Roof System: — Class C roof covering system covered with: Membrane: — Any UL Classified AFX membrane, "VersiFleece KEE HP", "WeatherBond KEE HP Fleece", "VersiFleece FRS PVC" or "WeatherBond PVC FRS Fleece", "VersiFleece FRS KEE HP", "WeatherBond KEE HP FRS Fleece" or "VersiFleece PVC Membranes".11/27/2019 11/4/2019 VERSICO INC, TGFU.R9853 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R9853 103/103 UL and the UL logo are trademarks of UL LLC © 2019 All Rights Reserved. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A 1. Deck: NC Incline: 3 Insulation: — "Versico Recovery Board" 0.450 to 3.0-in. mechanically fastened with metal insulation anchors or fully adhered with hot roofing asphalt. Base Sheet: — 3 to 5 layers Type 15 perforated felt or Type G1 asphalt glass fiber ply sheet. Surfacing: — Gravel, crushed stone or slag. Last Updated on 2019-10-28 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non- misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2019 UL LLC". 11/27/2019