Loading...
HomeMy WebLinkAboutFile Documents.230 E Hopkins Ave.0089.2018 (31).ACBKCOMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 90.1 (2013) Standard Project Type:Alteration Construction Site: 200-234 E. HOPKINS ASPEN, CO 81611 Owner/Agent: Peter Gluck 360 Hexagon LLC 119 Hyslop Road Brookline, MA 02445 Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com Project Information Energy Code: MOUNTAIN FORGE REMODEL Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-COMMON AREAS (Common Space Types:Corridor/Transition <8 ft wide)2060 0.66 1360 1360Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures COMMON AREAS ( Common Space Types:Corridor/Transition <8 ft wide 2060 sq.ft.) LED 1: R3 & R4: DOWNLIGHT: Other:1 56 12 666 LED 2: P2: PENDENT AT BATHROOM: Other:1 2 60 120 LED 3: P3: PENDENT AT BATHROOM: Other:1 2 15 30 LED 4: F2: LED STRIP AT UTILITY: Other:1 6 28 168 LED 5: S5: BATHROOM SCONCE: Other:1 9 6 56 LED 6: S6: BATHROOM SCONCE: Other:2 2 40 80 1120Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 09/04/19Report date: 71 ofPage Stanton O. Humphries, PE 09/04/19 09/06/2019 09/13/2019 nickt COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate Project Title: 90.1 (2013) Standard Project Type:Alteration Construction Site: 200-234 E. HOPKINS ASPEN, CO 81611 Owner/Agent: Peter Gluck 360 Hexagon LLC 119 Hyslop Road Brookline, MA 02445 Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com Project Information Energy Code: MOUNTAIN FORGE REMODEL 2 (Residential mixed use area)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) LOWER LEVEL (Entry canopy)300 ft2 0.25 Yes 75 MAIN LEVEL (Entry canopy)600 ft2 0.25 Yes 150 UPPER DECK (Walkway >= 10 feet wide)1809 ft2 0.14 Yes 253 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 478 478 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures LOWER LEVEL ( Entry canopy 300 ft2): Tradable Wattage LED 1: EX3: DOWNLIGHT: Other:1 1 23 23 LED 2: EX1: STEPLIGHT: Other:1 1 4 4 LED 3: EX5: SCONCE: Other:1 2 11 22 MAIN LEVEL ( Entry canopy 600 ft2): Tradable Wattage LED 4: EX1: STEPLIGHT: Other:1 6 4 23 LED 5: EX3: DOWNLIGHT: Other:1 11 23 253 LED 6: EX4: SCONCE: Other:1 4 15 60 LED 7: EX2: SCONCE: Other:1 5 11 55 UPPER DECK ( Walkway >= 10 feet wide 1809 ft2): Tradable Wattage LED 9: EX1: Other:1 13 4 51 LED 10: EX5: Other:1 2 11 22 LED 11: EX7: Other:1 4 7 28 541Total Tradable Proposed Watts = Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 09/04/19Report date: 72 ofPage 09/06/2019 09/13/2019 nickt Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 09/04/19Report date: 73 ofPage 09/04/19Stanton O. Humphries, PE 09/06/2019 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.1.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2013) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2, 8.4.1.1, 8.4.1.2, 8.7 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable 4.2.2, 9.4.3, 9.7 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable 9.7 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 09/04/19Report date: 74 ofPage 09/06/2019 Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions 8.4.2 [EL10]2 At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Complies Does Not Not Observable Not Applicable 9.4.1.1 [EL1]2 Automatic control requirements prescribed in Table 9.6.1, for the appropriate space type, are installed. Mandatory lighting controls (labeled as 'REQ') and optional choice controls (labeled as 'ADD1' and 'ADD2') are implemented. Complies Does Not Not Observable Not Applicable 9.4.1.1 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable 9.4.1.2 [EL11]2 Parking garage lighting is equipped with required lighting controls and daylight transition zone lighting. Complies Does Not Not Observable Not Applicable 9.4.1.1f [EL13]1 Daylight areas under skylights and roof monitors that have more than 150 W combined input power for general lighting are controlled by photocontrols. Complies Does Not Not Observable Not Applicable 9.4.1.4 [EL3]2 Automatic lighting controls for exterior lighting installed. Complies Does Not Not Observable Not Applicable 9.4.1.3 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 09/04/19Report date: 75 ofPage 09/06/2019 Section # & Req.ID Final Inspection Complies?Comments/Assumptions 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. 9.4.2 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 09/04/19Report date: 76 ofPage 09/06/2019 Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 09/04/19Report date: 77 ofPage 09/06/2019