HomeMy WebLinkAboutFile Documents.132 Vine St.0115.2018.ARBKThe City of Aspen
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
06/05/2018
READ THIS OR FAIL YOUR INSPECTION!
Furred & Dropped Ceilings, Soffits, and Walls
20015 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
Walls, Ceilings & Soffits: If furred 1 ¾ inches or
less, do one of the following:
4.Fill spaces with Class A material.
5.Fill spaces with inorganic or non-combustible material.
6.Fire block 8 feet in all directions.
Walls: If set out (furred) greater than 1 ¾ inches,
do one of the following:
4.Use a Class A finish material (such as drywall).
5.Use non-combustible framing.
6.Protect both sides with fire sprinklers.
Ceilings & Soffits: If dropped (furred) greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
Sinclair
Building | Architecture | Development, llc
APRIL 13, 2018
CITY OF ASPEN COMMUNITY DEVELOPMENT
BUILDING DEPARTMENT
517 E. HOPKINS, GARDEN LEVEL
ASPEN, CO 81611
VIA: ELECTRONIC SUBMITTAL
RE: “VERIFICATION OF STRUCTURAL INTEGRITY”
PRIVATE RESIDENCE INTERIOR ALTERATION • BATHROOM REMODEL
132 VINE STREET (HUNTER CREEK CONDOS)
ASPEN, CO 81611
TO WHOM IT MAY CONCERN:
PLEASE NOTE THAT, FOR THE ATTACHED PROPOSED MODIFICATIONS TO 132 VINE STREET,
THERE WILL BE NO WORK AFFECTING THE BUILDING’S STRUCTURE, OCCUPANCY OR EGRESS.
THE PROPOSED SCOPE IS ONLY TO WORK AROUND EXISTING STRUCTURAL AND NON-
STRUCTURAL PARTITION WALLS.
PLEASE CONTACT ME DIRECTLY WITH ANY QUESTIONS OR COMMENTS. YOU CAN ALWAYS
REACH MY CELL 970 948 4269 OR EMAIL ROB@SIN-BAD.COM
SINCERELY,
ROBERT G. SINCLAIR
04/25/2018
Code EdiƟons
Fire Sprinkler System
Type Of ConstrucƟon Fire Alarms Installed
Required Special InspecƟons
Energy Code Compliance
Exterior Energy Use Total Approved On-Site Snowmelt________Spa_______Pool _________
Building Type/Occupancy Group
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DESCRIPTION FORM -IRC &IBC
CITY OF ASPEN 130 S.GALENA ST |ASPEN,CO 81611
BUILDING CODE INFORMATION
2015 IRC
ExisƟng?NFPA 13 NFPA 13 R
High-Strength BolƟng Epoxy Anchors Structual Steel Welding
Permanent Micropiles Other _____________
PrescripƟve Table
UNIT DESCRIPTION AS PROPOSED
#Stories Above Grade ______#Stories Below Grade _______
Parking Spaces ______Parking Spaces ______Parking Spaces ______
#Bedrooms ______#Full Baths ______Deck Area ______
#3/4 Baths ______#1/2 Baths ______
#Kitchens ______#Wood Fireplaces ______
#Gas Appliances ______#Gas Logs______
NFPA 13 D
RESCheck UA AlternaƟve
Yes No
One Family Two Family
Townhouse
Reviewed By:_____________________Date:__________
BUILDING ROOMS AND USES BY LEVEL AS PROPOSED (Include Mechanical &Storage)
Basement ___________________________________________________________________________________
___________________________________________________________________________________________
Main Level __________________________________________________________________________________
____________________________________________________________________________________________
2nd Floor ___________________________________________________________________________________
__________________________________________________________________________________________
3rd Floor ___________________________________________________________________________________
___________________________________________________________________________________________
AddiƟonal ___________________________________________________________________________________
___________________________________________________________________________________________
AƩached Garage Detached Garage Carport
Is there an ADU?
#Living Rooms_____
#Kitchens _____
#Full Baths _____
#3/4 Baths _____
#1/2 Baths _____
#Bedrooms _____
#Other Rooms (List)____________
ADU BUILDING DESCRIPTION
Yes
No
PERMIT NUMBER:_______________________________
(As Adopted and Amended)
Other (Please Explain)
_________________
_________________
VA VB IV IIIA IIIB IIA IIB IA IB
Sprayed Fire-Resistants
COMCheck UA AlternaƟve
(ExisƟng +New)
A__B
B (A <50)
F__
H__
I __
E R__
S__
U
M
I
R
C
I
B
C
2015 IBC
(As Adopted and Amended)
Yes
No Required?Yes
No Type
January 2018
2015 IEBC
(As Adopted
and Amended)
Other _____________
Gross Area of Building:__________Gross Area of Unit:__________
Occupant Load:___________
N/A N/AN/A
condo
3
N/A
1201
0
0
00
0
1
1
2
3rd Floor Residential Condo Unit to remain as-is with minor Interior Alteration: a Master Bathroom remodel
N/A
N/A
N/A
N/A
ADDRESS: 132 Vine Street
04/25/2018
x
2
NT 6/20/18
06
/
2
0
/
2
0
1
8
ni
c
k
t
Dwelling Separation Required - 2015 IBC
-708 Fire Partitions, 711 Horizontal Assemblies:
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
rating of at least 1 hour. Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714: Penetrations must be protected by a through-penetration firestop
system. Recessed fixtures shall not reduce the required fire resistance by use
of a listed fixture, a listed firehood, or a drywall assembly meeting the required
fire resistance. Exhaust fans require ceiling radiation damper.
-1207 Sound Transmission: Separating walls and floor/ceilings shall have an
STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50.
2015 IBC 601 Fire Resistive Requirements for
Type of Construction: ____
Primary Structural Frame: ____hr
(columns, beams, girders, etc)
Exterior Bearing Walls: ____hr
Interior Bearing Walls: ____hr
Floors/Ceilings: ____hr
Roof : ____hr
Unless noted otherwise for occupancy separation or fire
separation distance.
VA
1
1
1
1
1
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT APPLICATION
CITY OF ASPEN 130 S.GALENA ST |ASPEN,CO 81611
PROPERTY INFORMATION
_______________________________________________________________________
____________________________________________________________________
__________________________________________________________________________
_________________________________________________________________________
Commerical
MulƟ-Family
Single Family
Use of Building Class of Work
New
AddiƟon
AlteraƟon
Repair
________
Yes
No
Will there be
any roof/wall
penetraƟons?
NOTICE:This permit becomes null and
void if work or construcƟon authorized
is not commenced within 180 days,or
if construcƟon or work is suspended or
abandoned for a period of 180 days at
any Ɵme aŌer work is commenced.
__________________
_________________
__________________
____________________
________________
_________________
__________
______________
PROJECTVALUATION
SQ FT OFWORKAREA
UNIT SQ FT
DISTURBEDEXTERIORAREA
SQ FT OF ROOMSWITHUTILITYWORK
LOT SIZE(SQ FT)
PROJECT DETAILS
Mixed-Use
IFFR
Tenant Finish
DemoliƟon
Change Order
________
ADDRESS UNIT #PARCEL ID #
BLOCK TRACTORSUBDIVISIONLOT
DESCRIPTION OFWORKINDETAIL
FOR CITY USE ONLY
Plan Check Permit Fee Parks Impact
Engineering Zoning (50%)School Ded.
Zoning (50%)CMP (50%)TDM Impact
Energy Code REMP Ped.Amenity
CMP (50%)Plan Check
(Hourly)Housing Cash in Lieu
Parks Review Zoning
(Hourly)Stormwater
UƟlity Review Engineering
(Hourly)City Use Tax
GIS County Use Tax
SUBMITTAL FEES ISSUANCE FEES
_________Lot Area _________Deed Restricted
_________Census Code _________#of Dwellings _________Plans LocaƟon
APPROVALS
ISSUANCE FEES
BEST CONTACTNAME CELL EMAIL
OWNER NAME CELL EMAIL
____Toilets,Bidets
____Bathtub
____Lavatory (Wash Basin)
____Shower
____Kitchen Sink (+Disposal)
____Dishwasher
____Laundry Bar,UƟlity Sink
____Clothes Washer
____Floor Sink
____Floor Drain
____Water Heater (Pan Req)
____#Gas Outlets
____Water Treatment
____Other_________
Fixture Counts
____Forced Air/Gravity Systems
____Wall,Suspended,or Unit Heaters
____Gas Log
____Gas Appliancew
____Appliance Vents
____Heat,Refrig,Cooling,or
AbsorpƟon Unit
____Boilers (includes vent)
____Air Handling Unit
____Cooling Systems
____VenƟlaƟon Fans
____Range Hood
____#of Gas System Outlets
____Snowmelt System Sq Ft_________
Equipment Checklist
PC
Zoning
HPC
Building
Fire
Engineering
CMP
Water
Stormwater
SanitaƟon
Env.Health
Parks
Landscape
Eĸciency
Approved
To Issue
Issuance
DateApprovedReviewingDepartment
Re-
viewer
Sign-
Oī
NEW SQ FT
Project ValuaƟon:Cost of project as deĮned in ValuaƟon Aīadavit.
Sq Ft of Work Area:Total square footage of area undergoing change or reconĮguraƟon.
Unit Sq Ft:Gross Square Footage,not FAR,of permiƩed unit.
Lot Size:Total surveyed square footage of property.
Disturbed Exterior Area:Square footage of lot aīected by permit applicaƟon.
New Sq Ft:Total added square footage for addiƟons to net livable or net leasble space.
Sq Ft of Rooms with UƟlity Work:Total square footage,not FAR,of all rooms with plumbing work.
DO YOU LIKE DOGS?
December 2017
DATE:___________MASTER PERMIT:______________________PERMIT NUMBER:__________________________
__________________________________________________________________________________
__________________________________________________________________________________
ZONE DISTRICT
NeedsReview
DEFINITIONS
132 Vine Street 132 2737 073 66 321
Hunter Creek
Danny Becker
Rob Sinclair
970-948-5769
970-948-4269 rob@sin-bad.com
danny.becker@elliman.com
$25,000
70
1201
N/A (ø)
N/A (condo)
N/A (ø)
N/A (ø)
1
1
1
04/13/2018
This minor ‘Interior Alteration’ is a Bathroom Remodel, which entails replacement of fixtures,
fitting, and finishes, including new lighting fixtures. Tub/Shower to be replaced by a stall shower.
0115.2018.ARBK
333.13
162.50
162.50
512.50
62.50
BB#549-714-219
KH
04/25/2018
R/MFA
RJN 6/5/180
0
0
0
N/A
NT 6/20/18
NT 6/20/18
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT CONTACT SHEET
CITY OF ASPEN 130 S.GALENA ST |ASPEN,CO 81611
_____________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________________
Name Phone Cell Phone
City
MailingAddress
E-mailAddress
State ZIP
OWNER
________________________________________________________________________________Name Phone E-mail
FOR PLAN REVIEW QUESTIONS
________________________________________________________________________________Name Phone E-mail
FOR INSPECTION QUESTIONS
_____________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________________
Name Phone Cell Phone
City
MailingAddress
E-mailAddress
State ZIP
OWNER’S AUTHORIZED AGENT
_____________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________________
Name Phone Cell Phone
City
MailingAddress
E-mailAddress
State ZIP
APPLICATION BEST CONTACT
_____________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________________
Name Phone Cell Phone
City
MailingAddress
E-mailAddress
State ZIP
ARCHITECT OR DESIGNER OF RECORD
_____________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________________
Name Phone Cell Phone
City
MailingAddress
E-mailAddress
State ZIP
CIVIL ENGINEER OF RECORD
_____________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________________
Name Phone Cell Phone
City
MailingAddress
E-mailAddress
State ZIP
STRUCTUAL ENGINEER OF RECORD
I hereby cerƟfy that I have read and examined this applicaƟon and know the same to be true and correct.All provisions of laws and
ordinances governing this type of work will be complied with whether speciĮed herein or not.The granƟng of a permit does not
presume to give authority to violate or cancel the provisions of any other state or local law regulaƟng construcƟon or the performance
of construcƟon.It is my responsibility to review the approved plans and any comments that are contained thereon and see that the
structure and/or project is built in compliance with all applicable codes.
_____________________________________________________________________________ContractorSignature Date
HNSPEIJHONS:Jhe Keneral Iontractor must schedule insLecƟons onlineM
Please Nisit wwwMasLenLitkinMcomODeLartmentsOIommunityPDeNeloLmentPFormsO to do soM
_____________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________________
Name Phone Cell Phone
City
MailingAddress
E-mailAddress
State ZIP
GENERAL CONTRACTOR
Check if you are a tested owner builder (single-family homes only).You must take a test and complete the owner/building aĸdavit.
(CITY USE ONLY)Owner builder approved by:________________________Date:______________________Aĸdavit on Įle
ADDRESS:____________________________PERMIT NUMBER:_______________________________
August 2017
132 Vine Street
Rob Sinclair
Rea Coulter
Danny Becker
P.O. Box 8114
Sinclair Building|Architecture|Development
CO
rob@sin-bad.com
Aspen
970-948-4269970-925-4269
81612
P.O. Box 8114
Rob Sinclair
CO
rob@sin-bad.com
Aspen
970-948-4269970-925-4269
81612
P.O. Box 8114
Rob Sinclair
CO
rob@sin-bad.com
Aspen
970-948-4269970-925-4269
81612
P.O. Box 8114
Rob Sinclair
CO
rob@sin-bad.com
Aspen
970-948-4269970-925-4269
81612
04/13/2018
rob@sin-bad.com
970-948-5769
970-379-9894 rea@sin-bad.com
970-925-4269
132 Vine Street CO
danny.becker@elliman.com
Aspen 81611
04/25/2018
DAM 6/22/18