These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
SPECIAL INSPECTION REQUIRED:
-Structural steel welding: Field & Shop
-High strength bolting
Special inspection is required per 2015 IBC
section 1704. Inspector to verify that copy of
agreement for inspection program to be on
the job site prior to performing any
inspections. A copy of all Special Inspector
field reports to be on the job site for
inspectors' review if requested. Failure to
comply may result in denial of inspection.
FIRE
SPRINKLERS
REQUIRED
ASPEN LINE GRADE VERIFICATION FORMASPEN LINE GRADE VERIFICATION FORM
Webpage: http://www.aspenpitkin.com/pdfs/depts/41/linegradeverificationform.pdf Rev. 04-08
Verification of Building Location by Building Contractor
For Building and Permit Information, please refer to our website at:
http://www.aspenpitkin.com/depts/41/
Exemption
A City verification of building location is not needed when the project creates less the 200 square feet of new floor area.
PART A: Complete and Submit as part of the Building Permit Application
o Building / Job Address or Location: _____________________________________________
o Your Name (Person Completing Part A): ____________________________________________
o Your Company: ________________________________________________________________
o Plans must show horizontal dimensions that ‘tie’ the building to the property boundary.
Are building ties shown? (circle one) ‘Yes’ ‘No’
o An elevation benchmark needs to be established on the site by a licensed surveyor and shown on the plans. What is the
elevation of this benchmark? _________________________________
o If the garage is located within 10 feet of the roadway or sidewalk, provide spot elevation on the on the roadway or sidewalk.
Is a spot elevation shown? ‘Yes’ ‘No’ ‘N/A’
o Provide the equation comparing site (surveyed) elevation to structure/ architectural plan elevation:
(i.e., 100’ first floor elev = 7962.50’) _______________________________
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
PART B: Complete prior to first Foundation Inspection, by a licensed surveyor or an individual prequalified by the City
o Do field measured building ties to property match building ties shown on the plan? (circle one): ‘Yes’ ‘No’
o Surveyor needs to confirm that one spot on the top of the foundation wall is at the same elevation shown on the approved
building plans.
o What is the field measured elevation of top of foundation wall relative to the site bench mark? ____________
o According to the building plans, what was the design elevation for the same place on the foundation wall?
______________________________
o Was the elevation of the building adjusted in field? (circle one): ‘Yes’ ‘No’
o If yes, why? ________________________________________________
The undersigned qualified individual certifies that the information in Part B is accurate -
Signature: Date: _
Printed Name: Contact ph. # : ____________________
Company: ______________________________________________________________
210 W. Main Street, Aspen CO 81611
Kim Raymond
Kim Raymond Architects Inc.
x
x
100'-0" = 7895.30'
Site Benchmark- El. = 7894.65'
Colorado Department of Public Health and Environment
Air Pollution Control Division-Indoor Environment Program-Asbestos/lAO Air Unit
4300 Cherry Creek Drive South, APCD-IE-81
Denver, Colorado 80246-1530
Phone: 303-692-3100-Fax: 303-782-0278
E-mail: asbestos@state.co.us
DEMOLITION APPROVAL NOTICE
This approval notice is granted subject to Colorado Air Quality Control Commission Regulation
No.8, Part B , adopted December 21, 2007, and effective January 30, 2008 and the Colorado Air
Pollution Prevention and Control Act C.R.S. (25-7-101 and 25-7-501 et seq). This notic~ signifies
that the structure was inspected for asbestos, luminous exit signs (containing radioactive material),
and Ozone-Depleting Refrigerants and the demolition contractor has properly notified the .
Colorado Department of Public Health and Environment pursuant to Regulation No.8, Part B.
As a contractor, you may be subject to other demolition licenses and permits, depending on the
requirements of the county and municipality in which the work is peing performed. The Colorado
Department of Public Health and Environment, Air Pollution Control Division, strongly suggests
that you check with county and municip'alauthorities in order to -determine any other local
building/permitting requirements that must be met.
Please note that certain asbestos-containing materials (ACM) may remain in the structure
during demolition. Therefore, any demolition debris left behind after the completion of post-
demolition site cleanup may constitute a "reason to know of asbestos-contaminated soil" at
the site, subject to the requirements of Section 5.5 of the Solid Waste Regulations (6 CCR
1007-2, Part 1).
THE ORIGINAL APPROVAL NOTICE MUST BE POSTED ON SITE AT ALL TIMES.
Immediately notify the Asbestos/IAQ Unit of project modifications by fax (number above) or e-mail
(address above) and the appropriate county health department by fax. Project modifications include
changes in the scope of work or the scheduled work dates, etc.
This demolition approval notice is valid beginning 7/22/2 019.
The actual scheduled work dates are from 7/22/2019 through 7/29 /2 019.
Approval issued on : 7118/2019
Record number: 150708 Fee Paid: $60.00
Notice Number: 19PI4726D
For the location specified below:
Fourplex
210 W. Main
Aspen
Pitkin County
This notice has been issued to:
Keelty Construction Inc
204 Park Ave. Ste. 1K
Basalt, CO ~1621
Check number: 2920
Asbestos Building Inspector:
Douglas A. Close
Cerification No.: 2930
Inspection Date: 06/25/2019
11/25/2019
nickt
SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
External Energy Use Approved
RREMP CREMP
PERMIT #:_______________DATE:________
SNOWMELT:_____________________________
POOL: _____________________________
SPA: _____________________________
OFFSET:________________________________
REMP SHEET: __________________________
REVIEWED BY: _________________________
SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S.
All snowmelt systems shall meet the following:
-Any portions in the Right of Way must be on a separate zone. A ROW
permit and Permanent Encroachment License are required.
-R10 insulation shall be installed under the area to be snow melted or R5
insulation shall be installed under and at the slab edges. (Ordinance 11
Series 2011)
-Automatic controls installed for system shut off when pavement
temperature is above 50°F and no precipitation is falling. (2009 IECC
Sec. 403.8 & 503.2.4.5)
-Automatic or manual controls installed for system shut off when outdoor
temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5)
-Inspection by testing hydrostatically at 1½ times max system design
pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec.
1208.1)
MINIMUM BOILER AFUE: _________________
x
0056.2019.ARBK 11/25/19
0
0
0
NT
03/16/2019
10,817sqft
x
2
NT 11/25/19
Units 101 and 103 are Type B Accessible units
x 2
x
RESIDENTIAL REFERENCES FROM 2015 IBC
CV/CS = crawl space ventilation sec. 1203.4. 18” x 24” access required
1209.1
EE = emergency escape required sec 1030
EU = enclosed usable space under stairs shall be 1-hr construction or stair
enclosure rating. No access from stair enclosure. ½” gypsum permitted for
stairs inside a single dwelling unit. 1011.7.3.
RV = roof and rafter ventilation required 1203.2
A = Attic Access 20” x 30” 1209.2
SA = smoke alarm (NFPA 72) required sec 907.2.11
CO = carbon monoxide detector req. per Aspen Municipal Code 8.15
SG = safety glazing required sec 2406
V = mechanical ventilation required sec 1203.1 & IMC 403 (bath fans and
whole house ventilation)
GR = guards, 42” min ht, 4” max opening. Guards within dwelling unit 36” min
ht sec 1015
HR = handrails 34”-38” ht sec 1014
DS = Draft stopping / fire blocking 718
RD = Roof drainage 1503.4
STC = Sound transmission class not less than 50 at dwelling separations, sec
1207
SI = Stairway Illumination 1205.4
PD = protect against decay, sec 2304.12
REFERENCES FROM 2015 IMC
DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM
AS = access and service space for maintenance req’d, sec 306
MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2
ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes,
501.3.1
IT= intake openings 10’ from lot line & contaminant sources (vents, streets),
401.4
D = fasten and seal all ductwork per 603.9
REFERENCES FROM 2015 IFGC
DV = direct vent req’d, sec 303.3
CA = combustion air not taken from bedrooms, bathrooms or
storage sec 303.3
OD = outdoor appliances must be listed for outdoor use, sec 303.6
REFERENCES FROM 2015 IECC
F = new or replacement fenestration shall not exceed 0.28 U-factor, NFRC
label required, Ordinance 40, 2016
L = 75% of lamps in permanently installed lights must be high efficacy, sec
R404.1
SE = Continuous air barrier required; all exterior joints, cracks, and holes to be
caulked, gasketed, sealed, table R402.4.1.1
REFERENCES FROM 2014 NEC
EP = electric panel 'happy space' 30"x36"x78", not in storage, sec 110.26
Electric vehicle charging (IRC 309.6).
Newly constructed one- or two-family dwellings and townhouses with a dedicated attached or
detached garage shall facilitate future installation and use of electric vehicle chargers. For each
dwelling unit, a 208/240-volt individual branch circuit or a listed raceway to accommodate a future
individual branch circuit shall be installed. The raceway shall not be less than trade size 1 (nominal
1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall
terminate into a listed cabinet, box or other enclosure, and in close proximity to the proposed
location of the electric vehicle charger. Raceways are required to be continuous at enclosed,
inaccessible or concealed areas and spaces. The service panel or subpanel circuit directory shall
provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to
permit installation of a branch circuit overcurrent device. Electrical vehicle supply equipment shall be
installed in accordance with NFPA 70. 20
Exception: Additions and alterations to existing one- or two-family dwellings and townhomes
constructed per the IRC are exempt from this requirement.
Recessed luminaires installed
in building thermal envelope
shall be sealed and IC-rated
– IECC sec R402.4.5
Any recessed light fixtures
in contact with insulation
must be IC rated.
FIRE RATED HATS REQUIRED
Where floor/ceiling or roof/ceiling
assemblies are required to have a
fire-resistive rating, recessed fixtures shall
be installed such that the required fire
resistance will not be reduced (IBC 714.4.2)
Dwelling Separation Required - 2015 IBC
-708 Fire Partitions, 711 Horizontal Assemblies:
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
rating of at least 1 hour. Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714: Penetrations must be protected by a through-penetration firestop
system. Recessed fixtures shall not reduce the required fire resistance by use
of a listed fixture, a listed firehood, or a drywall assembly meeting the required
fire resistance. Exhaust fans require ceiling radiation damper.
-1207 Sound Transmission: Separating walls and floor/ceilings shall have an
STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50.