Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (40).ACBKThe City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK SPECIAL INSPECTION AND TESTING AGREEMENT To permit applicants of project requiring special inspection and\or testing per Section 1704 of the International Building Code (IBC). Project Address: __________________________________ Permit Number:______________________ BEFORE A PERMIT CAN BE ISSUED: The owner, or the engineer or architect of record, acting as the owner’s agent, shall complete two copies of this agreement and the attached Special-inspection and Testing Schedule, including the required acknowledgments. A pre-construction conference with the parties involved may be required to review the special-inspection requirements and procedures. APPROVAL OF SPECIAL INSPECTORS: Special inspectors may have no financial interest in the projects for which they provide special inspections. Special inspectors shall be approved by the building department prior to performing any duties. Special inspectors shall submit their qualifications and are subject to personal interviews for pre-qualification. Special inspectors shall display approved identification, as stipulated by the building official, when performing the function of special inspector. Special inspection and testing shall meet the minimum requirements of the International Building Code Section 1704. The following conditions are also applicable: A. Duties and Responsibilities of the Special Inspector 1. Signify presence at job site. Special inspectors should notify contractor personnel of their presence and responsibilities at the job site. If required by the building official, they shall sign in on the appropriate form posted with the building permit. 2. Observe assigned work. The special inspector shall observe assigned work for conformance with the building department approved (stamped) design drawings, specifications, and applicable workmanship provisions of the International Building Code. Architect\engineer-reviewed shop drawings may be used only as an aid to inspection. For continuous special-inspection, the special inspector shall be on site at all times observing the work requiring special inspection. Periodic inspections, if any, must have prior approval based on a separate written plan reviewed and approved by the building department and the engineer or architect of record. 3. Report nonconforming items. The special inspector shall bring nonconforming items to the immediate attention of the contractor and note all such items in the daily report. If any item is not resolved in a timely manner or is about to be incorporated in the work, the special inspector shall immediately notify the building department by telephone or in person, notify the engineer or architect, and post a discrepancy notice. 4. Provide timely reports. The special inspector shall complete written inspection reports for each inspection visit and provide the reports on a timely basis determined by the building official. The special inspector or inspection agency shall furnish these reports directly to the building official, engineer or architect of record, and others as designated. [IBC Sec. 1704.1.2] These reports should be organized on a daily format and may be submitted weekly at the option of the building official. These reports should include: a. Description of daily inspections and tests made with applicable locations, b. Listing of nonconforming items, c. Report on how nonconforming items were resolved or unresolved as applicable, d. Itemized changes authorized by the architect, engineer, and building official if not included in nonconforming items. 1 425 Rio Grande Place 0016.2019.ACBK 06/24/2019 5. Provide Final Inspection Report. The special inspector shall submit a written final report documenting required special inspections and correction of any discrepancies noted in the inspections prior to the final building inspection. B. Owner Responsibilities. The project owner, the engineer or architect or record, or an agent of the owner is responsible for employing special-inspection services. The special inspector\agency shall not be in the employ of the contractor, subcontractor or material supplier. [IBC Sec 1704.1] In case of an owner\contractor, the special inspector\agency shall be employed as specified by the building official. C. Engineer or Architect of Record Responsibilities 1. Prepare special inspection program. The engineer or architect of record shall list the items for which special inspection is required; and shall indicate any items for which the IBC or the building official approves periodic inspection and the frequency of such inspections. 2. Respond to field discrepancies. The engineer or architect of record shall respond to uncorrected field discrepancies in design, material, or workmanship observed by the special inspector. 3. Review shop drawings and submit design changes. The engineer or architect of record shall acknowledge and review for conformance with the construction drawings those shop drawings that may detail structural information, shall submit to the building official and to the special-inspection agency written documentation of any verbally authorized deviations from the approved construction documents, and shall submit revised documents for building official approval as required. D. Contractor Responsibilities 1. Notify the special inspector. The contractor is responsible for notifying the special inspector or agency regarding individual inspections for items listed on the attached schedule and as noted on the building department approved plans. Adequate notice shall be provided so the special inspector has time to become familiar with the project. 2. Provide access to approved plans. The contractor is responsible for providing the special inspector access to approved plans. 3. Retain special inspection records. Upon request, the contractor is also responsible for retaining, at the job site, all special inspection records completed by the special inspector. E. Inspection of Fabricators 1. Fabrication of structural assemblies and members. Where fabrication of structural load-bearing members and assemblies is being performed on the premises of a fabricator’s shop, IBC Section 1704.2 shall require special inspection of the fabricated items. 2. Fabrication and implementation procedures. The special inspector shall verify that the fabricator maintains detailed fabrication and quality control procedures that provide a basis for inspection control of the workmanship and the fabricator’s ability to conform to approved construction documents and reference standards. The special inspector shall review the procedures for completeness and adequacy relative to code requirements for fabricator’s scope of work. F. Approved Fabricator Responsibilities 1. Fabrication exempt inspections. Special inspections are not required where work is done on the premise of a fabricator registered and approved to perform such work without special inspection. 2 06/24/2019 425 RIO GRANDE PLACE 0016.2019.ACBK 06/24/2019 NICK THOMPSON 7/22/19 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT CONTACT SHEET CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP OWNER ___________________________________ _____________________ ________________________Name Phone E-mail FOR PLAN REVIEW QUESTIONS ___________________________________ _____________________ ________________________Name Phone E-mail FOR INSPECTION QUESTIONS ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP OWNER’S AUTHORIZED AGENT ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP APPLICATION BEST CONTACT ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP ARCHITECT OR DESIGNER OF RECORD ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP CIVIL ENGINEER OF RECORD ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP STRUCTUAL ENGINEER OF RECORD I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. It is my responsibility to review the approved plans and any comments that are contained thereon and see that the structure and/or project is built in compliance with all applicable codes. ________________________________________________________ _____________________ContractorSignature Date INSPECTIONS: The General Contractor must schedule inspections online. Please visit www.aspenpitkin.com/Departments/Community-Development-Forms/ to do so. ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP GENERAL CONTRACTOR Check if you are a tested owner builder (single-family homes only). You must take a test and complete the owner/building affidavit. (CITY USE ONLY) Owner builder approved by:________________________Date:______________________ Affidavit on file ADDRESS: ____________________________PERMIT NUMBER: _______________________________ August 2017 2.28.19 425 RIO GRANDE PLACE ASPEN CO 81611 0016.2019.ACBK 970-925-5590RICH PAVCEK richp@cunniffe.com 205-447-0424BRIAN THOMAS brianthomas@shawconstruction.net CITY OF ASPEN 970-925-5590Charles Cunniffe - Charles Cunniffe Architects 610 E Hyman Ave Aspen CO 81611 richp@cunniffe.com 970-925-5590RICH PAVCEK - Charles Cunniffe Architects 610 E HYMAN AVE ASPEN CO 81611 richp@cunniffe.com 970-925-5590Charles Cunniffe Architects 610 E HYMAN AVE ASPEN CO 81611 richp@cunniffe.com 970-340-4130ROARING FORK ENGINEERING, RICHARD GOULDING 592 HIGHWAY 133 CARBONDALE CO 81623 richardg@rfeng.biz 970-510-5701KL&A, DAN DOHERTY 215 N 12TH ST UNIT E CARBONDALE CO 81623 ddoherty@klaa.com 970-242-9236SHAW CONSTRUCTION, BRIAN THOMAS 760 HORIZON DR #201 GRAND JUNCTION CO 81506 brianthomas@shawconstruction.net 3/6/19 03/16/2019 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT APPLICATION CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 PROPERTY INFORMATION ___________________________________ _________ ___________________________ ______________ ______________ ________________________________________ _________________________ _______________ __________________________________ ________________________ _______________ __________________________________ CommericalMulti-FamilySingle Family Use of Building Class of Work NewAdditionAlterationRepair ________ YesNo Will there be any roof/wall penetrations? NOTICE: This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended or abandoned for a period of 180 days at any time after work is commenced. _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ PROJECTVALUATION SQ FT OF BUILDING WORK AREA UNIT SQ FT SQ FT OF SOILDISTURBANCE BUILDING FOOTPRINT LOT SIZE(SQ FT) PROJECT DETAILS (READ DEFINITIONS BELOW) Mixed-Use IFFRTenant FinishDemolitionChange Order ________ ADDRESS UNIT #PARCEL ID # BLOCK TRACT OR SUBDIVISIONLOT DESCRIPTION OF WORK IN DETAIL Building Review Building Permit Fee Parks Impact Engineering Review Zoning Review (50%) School Lands Dedication Zoning Review (50%) CMP (50%)TDM Impact Energy Code Review REMP Payment Pedestrian Amenity CMP (50%)GIS Housing Cash in Lieu Parks Review City Use Tax Water Tap Utility Review County Use Tax Sanitation SUBMITTAL FEES ISSUANCE FEES APPROVALS ISSUANCE FEES BEST CONTACTNAME CELL EMAIL OWNER NAME CELL EMAIL ____Toilets, Bidets ____Bathtub____Lavatory (Wash Basin)____Shower____Kitchen Sink (+Disposal)____Dishwasher____Laundry Bar, Utility Sink____Clothes Washer ____Floor Sink____Floor Drain____Water Heater (Pan Req)____# Gas Outlets____Water Treatment____Other_________ Fixture Counts Important Review Triggers PC Zoning HPC Building Fire Engineering CMP Water Stormwater Sanitation Env. Health Parks Landscape Efficiency Approved To Issue Issuance Date ApprovedReviewingDepartmentReviewerSign-Off NEW SQ FT Project Valuation: Cost of project as defined in Valuation Affadavit.Sq Ft of Building Work Area: Total square footage of interior area undergoing change or reconfiguration.Unit Sq Ft: Gross square footage, not FAR, of permitted unit.Lot Size: Total surveyed square footage of property.Sq Ft of Soil Disturbance: Exterior area of the lot where the ground is disturbedNew Sq Ft: Total added square footage for additions to net livable or net leasable space.Building Footprint: Grade floor square footage of the permitted structure.Hardscape Area: Square footage of impervious lot surface.Zone District: Underlying zone district of permitted parcel. January 2019 DATE:___________ MASTER PERMIT:______________________ PERMIT NUMBER:__________________________ __________________________________________________________________________________ __________________________________________________________________________________ HARDSCAPEAREA NeedsReview DE F I N I T I O N S ZONEDISTRICT Major Engineering Review• Projects involving less than 50% hardscape area and work affecting 75% or greater of unit sq ft• Projects involving greater than 50% hardscape area and work affecting 50% or greater of unit sq ft• Projects involving 1,000+ sq ft of soil disturbance area Water Efficient Landscaping• Projects that trigger a major engineering review • Projects involving interior alterations affecting 50% or more of exisiting gross square footage THIS SECTION MUST BE COMPLETED IN ITS ENTIRETY 3/5/2019 0016.2019.ACBK 425 RIO GRANDE PLACE ASPEN CO 81611 2737-073-06-851, 2737-073-06-852, 2737-073-06-854 1, 2, & 4 -RIO GRANDE SUBDIVISION City of Aspen RICH PAVCEK 970-618-885 richp@cunniffe.com A NEW 3 STORY OFFICE ADDITION TO THE EXISTING RIO GRANDE PARKING GARAGE AND PITKIN COUNTY LIBARARY. CONNECTIONS WILL BE PROVIDED TO THE PARKING GARAGE AND ADJACENT RIO GRANDE BUILDING. LANDSCAPING SCOPE TO INCLUDE IMPROVEMENTS ALONG RIO GRANDE PLACE AND A PORTION OF THE EXISTING CIVIC PLAZA OVER THE PARKING GARAGE. $19,000,000 18n 12 n n 40,712 SF 193,941 SF 75,034 SF 3 42,842 SF 40,712 SF 44,090 SF 29,332 SF PUB - PD X JB 3/16/19 X X X 51276.88 78887.50 X X 18922.29 21628.25 X X 21628.25 4333.90 X X 11833.12 X 4333.90 250 X 1125.51 03/16/2019 FIRE SPRINKLERS REQUIRED EXCAVATION / STABILIZATION AND FOUNDATION JPO 7/22/19 SUNRISE 7/22/19 DAM 7/22/19 0016.2019.ACBK CITY OF ASPEN 427 RIO GRANDE PLACE 273707306851 Skylight U-factor To document the chain of custody, verification labels must be affixed to the skylight units by an accredited independent inspection agency or a certificate, affidavit or other evidence from the manufacturer confirming compliance with the NFRC-100 simulation or testing. SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Epoxy anchors -Intumescent paint -Spray applied fire resistive materials -Permanent micropiles Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. MANDATORY TESTING REQUIRED This construction project is required to comply with the 2015 International Energy Conservation Code. Commercial projects will require a blower door test performed in the manner complying with section C402.5 of the 2015 IECC. Maximum 0.40 cfm/sqft at 75 Pa. Channel Glass U-factor The channel glass is not approved. This permit is issued with a place holder U-factor of 0.30 for the channel glass with the understanding that you will either provide sufficient documentation of the actual channel glass U-factor or will substitute for another product, either of which will be demonstrated to have a U-factor of 0.30 or less. External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ x 0016.2019.ACBK 3/9/20 4754sf 0 0 M1.01, M1.02, M1.03, M8.02 95% N/A NT Code Editions Fire Sprinkler System Type Of Construction Fire Alarms Installed Required Special Inspections Energy Code Compliance Exterior Energy Use Total Approved On-Site Snowmelt________ Spa_______ Pool _________ Building Type/Occupancy Group COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DESCRIPTION FORM - IRC & IBC CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 BUILDING CODE INFORMATION 2015 IRC Existing?NFPA 13 NFPA 13 R High-Strength Bolting Epoxy Anchors Structual Steel Welding Permanent Micropiles Other _____________ Prescriptive Table UNIT DESCRIPTION AS PROPOSED # Stories Above Grade ______ # Stories Below Grade _______ Parking Spaces ______ Parking Spaces ______ Parking Spaces ______ # Bedrooms ______ # Full Baths ______ Deck Area ______ # 3/4 Baths ______ # 1/2 Baths ______ # Kitchens ______ # Wood Fireplaces ______ # Gas Appliances ______ # Gas Logs______ NFPA 13 D RESCheck UA Alternative Yes No One Family Two Family Townhouse Reviewed By: _____________________Date:__________ BUILDING ROOMS AND USES BY LEVEL AS PROPOSED (Include Mechanical & Storage) Basement ___________________________________________________________________________________ ___________________________________________________________________________________________ Main Level __________________________________________________________________________________ ____________________________________________________________________________________________ 2nd Floor ___________________________________________________________________________________ __________________________________________________________________________________________ 3rd Floor ___________________________________________________________________________________ ___________________________________________________________________________________________ Additional ___________________________________________________________________________________ ___________________________________________________________________________________________ Attached Garage Detached Garage Carport Is there an ADU? # Living Rooms_____# Kitchens _____# Full Baths _____# 3/4 Baths _____# 1/2 Baths _____# Bedrooms _____ # Other Rooms (List)____________ ADU BUILDING DESCRIPTION YesNo PERMIT NUMBER: _______________________________ (As Adopted and Amended) Other (Please Explain) _________________ _________________ VA VB IV IIIA IIIB IIA IIB IA IB Sprayed Fire-Resistants COMCheck UA Alternative (Existing + New) A__B B (A <50) F__ H__ I __ E R__ S__ U M IRC IBC 2015 IBC (As Adopted and Amended) Yes No Required?Yes No Type January 2018 2015 IEBC (As Adopted and Amended) Other _____________ Gross Area of Building: __________ Gross Area of Unit: __________ Occupant Load: ___________ 0016.2019.ACBK n n n n n n n n n n n n 4754 SF 0 0 n n n 192,179 1545 n 3 2 Library, Garge, MECHANICAL & STORAGE Library, Garage, OFFICE Library, Garage, OFFICE Library, OFFICE & LARGE MEETING ROOMS (ACCESSORY ASSEMBLY), EXTERIOR PEDESTRIAN PLAZA NT 3/9/20 03/16/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 03/10/2020 This site will require various modifications, additions, and deletions of Erosion Control BMPs throughout the project. The Contractor and Owner shall work together to find and implement these changes in a timely and efficient manner. 03/10/20 SUNRISE NT 3/10/20 AR 11/17/19 SW 12/4/19 HG 11/17/19 CS 11/17/19 LC 11/17/19 DR 11/17/19 RM 11/17/19 COMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0016.2019.ACBK Vertical Glazing / Wall Area:25% Location:Aspen, Colorado Climate Zone:7 Construction Site: 425 Rio Grande Place Aspen, CO 81611 Owner/Agent: City of Aspen 130 S. Galena Street Aspen, CO 81611 970-309-7638 jeff.pendarvis@cityofaspen.com Designer/Contractor: Shaw Construction 760 Horizon Drive Suite 201 Grand Junction, CO 81506 970-242-9236 brianthomas@shawconstruction.net Project Information Energy Code: Aspen City Office 1%Skylight / Roof Area Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Building Area Floor Area 1-City of Aspen Office Building (Office) : Nonresidential 35984 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1: Other Roof, [Bldg. Use 1 - City of Aspen Office Building] (b)2796 ------0.026 0.021 Roof 2: Insulation Entirely Above Deck, [Bldg. Use 1 - City of Aspen Office Building] 6632 ---40.0 0.025 0.028 Roof 3: Attic Roof with Steel Joists, [Bldg. Use 1 - City of Aspen Office Building] 8190 40.0 0.0 0.033 0.021 Roof 4: Attic Roof with Steel Joists, [Bldg. Use 1 - City of Aspen Office Building] 58 40.0 0.0 0.033 0.021 Roof 5: Attic Roof with Steel Joists, [Bldg. Use 1 - City of Aspen Office Building] 20 40.0 0.0 0.033 0.021 Roof 6: Attic Roof with Steel Joists, [Bldg. Use 1 - City of Aspen Office Building] 528 30.0 10.0 0.029 0.021 Skylight: Metal Frame with Thermal Break:Glass, With Curb, Perf. Specs.: Product ID Wasco Pinnacle 600 System, SHGC 0.28, [Bldg. Use 1 - City of Aspen Office Building] (c) 106 ------0.230 0.500 Main Level (Floor 1): Steel Joist, [Bldg. Use 1 - City of Aspen Office Building] 4489 20.0 20.0 0.025 0.033 Middle Level (Floor 2): Steel Joist, [Bldg. Use 1 - City of Aspen Office Building] 1046 40.0 0.0 0.032 0.033 Middle Level (Floor 3): Steel Joist, [Bldg. Use 1 - City of Aspen Office Building] 2139 40.0 0.0 0.032 0.033 Upper Level (Floor 4): Steel Joist, [Bldg. Use 1 - City of Aspen Office 1167 40.0 0.0 0.032 0.033 Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.425 Rio Grande Place.2020.03.09.cck 03/09/20Report date: 151 ofPage 03/09/2020 Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Building] Main Level - Trash Vestibule Floor (Floor 5): Steel Joist, [Bldg. Use 1 - City of Aspen Office Building] 58 40.0 0.0 0.032 0.033 Middle Level - Bay Window Floor (Floor 6): Steel Joist, [Bldg. Use 1 - City of Aspen Office Building] 20 40.0 0.0 0.032 0.033 NORTH BASEMENT - Wall 02: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 16.2, Depth B.G. 16.2, [Bldg. Use 1 - City of Aspen Office Building] 388 ---22.0 0.042 0.085 BASEMENT - Wall 03: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 16.2, Depth B.G. 16.2, [Bldg. Use 1 - City of Aspen Office Building] 784 ---22.0 0.042 0.085 BASEMENT - Wall 05: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 13.8, Depth B.G. 13.8, [Bldg. Use 1 - City of Aspen Office Building] 233 ---22.0 0.042 0.085 BASEMENT - Wall 07: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 13.8, Depth B.G. 13.8, [Bldg. Use 1 - City of Aspen Office Building] 555 ---22.0 0.042 0.085 MAIN - Wall 02: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 604 21.0 10.0 0.048 0.064 Window 41: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 2.60, [Bldg. Use 1 - City of Aspen Office Building] (c) 174 ------0.260 0.290 MAIN - Wall 03: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 1001 21.0 10.0 0.048 0.064 Window 5: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.90, [Bldg. Use 1 - City of Aspen Office Building] (c) 298 ------0.260 0.290 MAIN - Wall 04: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 224 21.0 10.0 0.048 0.064 MAIN - Wall 05: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 172 21.0 10.0 0.048 0.064 Door 2: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 1.06, [Bldg. Use 1 - City of Aspen Office Building] (c) 48 ------0.260 0.770 MAIN - Wall 06: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 81 21.0 10.0 0.048 0.064 MAIN - Wall 07: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 290 21.0 10.0 0.048 0.064 Window 7: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 59 ------0.260 0.290 MAIN - Wall 08: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 41 21.0 10.0 0.048 0.064 MAIN - Wall 09: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 545 21.0 10.0 0.048 0.064 Window 8: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 78 ------0.260 0.290 Window 37: Metal Frame with Thermal Break:Operable, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 39 ------0.260 0.370 MAIN - Wall 10: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 252 21.0 10.0 0.048 0.064 Window 9: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 26 ------0.260 0.290 Window 38: Metal Frame with Thermal Break:Operable, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 13 ------0.260 0.370 Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.425 Rio Grande Place.2020.03.09.cck 03/09/20Report date: 152 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter MAIN - Wall 14: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 111 0.0 20.0 0.044 0.064 MAIN - Wall 15: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 238 0.0 20.0 0.044 0.064 Door 4: Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 21 ------0.300 0.370 MIDDLE - Wall 02: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 947 21.0 10.0 0.048 0.064 Window 12: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 129 ------0.260 0.290 Window 13: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 197 ------0.260 0.290 Window 42: Metal Frame:Operable, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 64 ------0.260 0.370 MIDDLE - Wall 03: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 21 21.0 10.0 0.048 0.064 Window 41: Other Window:Fixed, Perf. Specs.: Product ID Pilkington, SHGC 0.27, [Bldg. Use 1 - City of Aspen Office Building] (c) 21 ------0.300 0.290 MIDDLE - Wall 04: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 388 21.0 10.0 0.048 0.064 Window 40: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Pilkington, SHGC 0.41, [Bldg. Use 1 - City of Aspen Office Building] (c) 388 ------0.300 0.290 MIDDLE - Wall 06: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 49 21.0 10.0 0.048 0.064 MIDDLE - Wall 07: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 22 21.0 10.0 0.048 0.064 MIDDLE - Wall 08: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 111 21.0 10.0 0.048 0.064 Window 17: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 47 ------0.260 0.290 MIDDLE - Wall 10: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 56 21.0 10.0 0.048 0.064 MIDDLE - Wall 12: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 372 21.0 10.0 0.048 0.064 Window 18: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 52 ------0.260 0.290 Window 40: Metal Frame with Thermal Break:Operable, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 24 ------0.260 0.370 MIDDLE - Wall 14: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 184 21.0 10.0 0.048 0.064 Window 20: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 67 ------0.260 0.290 MIDDLE - Wall 15: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 750 21.0 10.0 0.048 0.064 Window 21: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 427 ------0.260 0.290 MIDDLE - Wall 17: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 222 21.0 10.0 0.048 0.064 UPPER - Wall 02: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 240 21.0 10.0 0.048 0.064 Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.425 Rio Grande Place.2020.03.09.cck 03/09/20Report date: 153 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Window 23: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.70, [Bldg. Use 1 - City of Aspen Office Building] (c) 154 ------0.260 0.290 UPPER - Wall 03: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 809 21.0 10.0 0.048 0.064 Window 24: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 2.80, [Bldg. Use 1 - City of Aspen Office Building] (c) 498 ------0.260 0.290 Door 8: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 96 ------0.260 0.770 UPPER - Wall 05: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 135 21.0 10.0 0.048 0.064 Window 26: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 1.00, [Bldg. Use 1 - City of Aspen Office Building] (c) 117 ------0.260 0.290 UPPER - Wall 11: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 92 21.0 10.0 0.048 0.064 UPPER - Wall 12: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 437 21.0 10.0 0.048 0.064 Window 29: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.08, [Bldg. Use 1 - City of Aspen Office Building] (c) 64 ------0.260 0.290 Window 30: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.08, [Bldg. Use 1 - City of Aspen Office Building] (c) 51 ------0.260 0.290 Door 10: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 62 ------0.260 0.770 UPPER LEVEL - THERMAL BRIDGING: Solid Concrete:12" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - City of Aspen Office Building] 92 ---0.0 0.630 0.071 EAST BASEMENT - Wall 04: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 13.8, Depth B.G. 13.8, [Bldg. Use 1 - City of Aspen Office Building] 445 ---22.0 0.042 0.085 BASEMENT - Wall 06: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 13.8, Depth B.G. 13.8, [Bldg. Use 1 - City of Aspen Office Building] 163 ---22.0 0.042 0.085 BASEMENT - Wall 08: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 13.8, Depth B.G. 13.8, [Bldg. Use 1 - City of Aspen Office Building] 265 ---22.0 0.042 0.085 MAIN - Wall 11: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 753 0.0 20.0 0.044 0.064 MIDDLE - Wall 05: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 85 21.0 10.0 0.048 0.064 Window 16: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Pilkington, SHGC 0.41, [Bldg. Use 1 - City of Aspen Office Building] (c) 85 ------0.300 0.290 MIDDLE - Wall 09: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 22 21.0 10.0 0.048 0.064 MIDDLE - Wall 11: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 39 21.0 10.0 0.048 0.064 MIDDLE - Wall 16: Wood-Framed, 24" o .c., [Bldg. Use 1 - City of Aspen Office Building] 410 21.0 10.0 0.036 0.051 UPPER - Wall 04: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 93 21.0 10.0 0.048 0.064 Window 25: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.50, [Bldg. Use 1 - City of Aspen Office Building] (c) 81 ------0.260 0.290 UPPER - Wall 06: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 161 21.0 10.0 0.048 0.064 Window 27: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.09, [Bldg. Use 1 - City of Aspen Office Building] (c) 55 ------0.260 0.290 Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.425 Rio Grande Place.2020.03.09.cck 03/09/20Report date: 154 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Door 9: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 48 ------0.260 0.770 UPPER - Wall 08: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 44 21.0 10.0 0.048 0.064 UPPER - Wall 09: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 801 21.0 10.0 0.048 0.064 Window 28: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Pilkington, SHGC 0.41, [Bldg. Use 1 - City of Aspen Office Building] (c) 761 ------0.300 0.290 UPPER - Wall 10: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 82 21.0 10.0 0.048 0.064 SOUTH BASEMENT - Wall 09: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 16.2, Depth B.G. 16.2, [Bldg. Use 1 - City of Aspen Office Building] 1090 ---0.0 0.630 0.085 BASEMENT - Wall 11: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 16.2, Depth B.G. 16.2, [Bldg. Use 1 - City of Aspen Office Building] 645 ---22.0 0.042 0.085 MAIN - Wall 12: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 1440 0.0 20.0 0.044 0.064 Door 3: Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 21 ------0.300 0.370 MAIN - Wall 16: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 111 0.0 20.0 0.044 0.064 MAIN - Wall 18: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 486 21.0 10.0 0.048 0.064 MIDDLE - Wall 23: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 163 0.0 20.0 0.044 0.064 MIDDLE - Wall 24: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 293 0.0 20.0 0.044 0.064 MIDDLE - Wall 26: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 1641 20.0 0.0 0.092 0.064 Door 5: Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 42 ------0.300 0.370 MIDDLE - Wall 28: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 96 21.0 10.0 0.048 0.064 MIDDLE - Wall 30: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 102 21.0 10.0 0.048 0.064 MIDDLE - Wall 32: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 486 21.0 10.0 0.048 0.064 UPPER - Wall 07: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 135 21.0 10.0 0.048 0.064 UPPER - Wall 13: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 580 21.0 10.0 0.048 0.064 Window 31: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.08, [Bldg. Use 1 - City of Aspen Office Building] (c) 53 ------0.260 0.290 Window 32: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, PF 0.08, [Bldg. Use 1 - City of Aspen Office Building] (c) 48 ------0.260 0.290 Door 11: Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 18 ------0.300 0.370 UPPER - Wall 13a: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 73 20.0 0.0 0.092 0.064 UPPER - Wall 15: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 315 21.0 10.0 0.048 0.064 WEST BASEMENT - Wall 01: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 16.2, Depth B.G. 16.2, [Bldg. Use 1 - City of 195 ---22.0 0.042 0.085 Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.425 Rio Grande Place.2020.03.09.cck 03/09/20Report date: 155 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Aspen Office Building] BASEMENT - Wall 10: Solid Concrete:12" Thickness, Normal Density, Furring: None, Wall Ht 16.2, Depth B.G. 16.2, [Bldg. Use 1 - City of Aspen Office Building] 269 ---22.0 0.042 0.085 BASEMENT - Wall 12: Solid Concrete:11" Thickness, Normal Density, Furring: None, Wall Ht 16.2, Depth B.G. 16.2, [Bldg. Use 1 - City of Aspen Office Building] 876 ---22.0 0.042 0.085 MAIN - Wall 01.1: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 652 21.0 10.0 0.048 0.064 Window 1: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 72 ------0.260 0.290 Window 2: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 72 ------0.260 0.290 Window 35: Metal Frame with Thermal Break:Operable, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 27 ------0.260 0.370 MAIN - Wall 01.2: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 503 21.0 10.0 0.048 0.064 Window 3: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 48 ------0.260 0.290 Window 36: Metal Frame with Thermal Break:Operable, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 18 ------0.260 0.370 Garage Door (Trash): Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 72 ------0.300 0.370 MAIN - Wall 13: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 281 0.0 20.0 0.044 0.064 MAIN - Wall 17: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 204 21.0 10.0 0.048 0.064 MIDDLE - Wall 01: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 1066 21.0 10.0 0.048 0.064 Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 132 ------0.260 0.290 Window 11: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 168 ------0.260 0.290 Window 39: Metal Frame with Thermal Break:Operable, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 54 ------0.260 0.370 MIDDLE - Wall 13: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 20 21.0 10.0 0.048 0.064 Window 19: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 15 ------0.260 0.290 MIDDLE - Wall 25: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 294 0.0 20.0 0.044 0.064 MIDDLE - Wall 27: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 68 21.0 10.0 0.048 0.064 MIDDLE - Wall 29: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 156 21.0 10.0 0.048 0.064 MIDDLE - Wall 31: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 207 21.0 10.0 0.048 0.064 UPPER - Wall 01: Wood-Framed, 24" o .c., [Bldg. Use 1 - City of Aspen Office Building] 694 21.0 10.0 0.036 0.051 Window 22: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 190 ------0.260 0.290 Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.425 Rio Grande Place.2020.03.09.cck 03/09/20Report date: 156 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter 0.30, PF 1.80, [Bldg. Use 1 - City of Aspen Office Building] (c) Door 6: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 98 ------0.260 0.770 Door 7: Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 18 ------0.300 0.370 UPPER - Wall 14: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 420 21.0 10.0 0.048 0.064 Window 33: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 190 ------0.260 0.290 Window 34: Metal Frame:Fixed, Perf. Specs.: Product ID Manko, SHGC 0.30, [Bldg. Use 1 - City of Aspen Office Building] (c) 41 ------0.260 0.290 UPPER - Wall 14a: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 308 20.0 0.0 0.092 0.064 CURVED CHANNEL GLASS AT ROOF: Steel-Framed, 24" o.c., [Bldg. Use 1 - City of Aspen Office Building] 296 21.0 10.0 0.048 0.064 Window 43: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Pilkington, SHGC 0.41, [Bldg. Use 1 - City of Aspen Office Building] (c) 88 ------0.300 0.290 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 1% better than code Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.425 Rio Grande Place.2020.03.09.cck 03/09/20Report date: 157 ofPage 03/10/2020 nickt 06/24/2019 06/27/2019 justinh 06/24/2019 06/27/2019 justinh 09/27/2019 COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Construction Site: 425 Rio Grande Place Aspen, CO 81611 Owner/Agent: City of Aspen 130 S. Galena Street Aspen, CO 81611 970-309-7638 jeff.pendarvis@cityofaspen.com Designer/Contractor: Shaw Construction 760 Horizon Drive Suite 201 Grand Junction, CO 81506 970-242-9236 brianthomas@shawconstruction.net Project Information Energy Code: Aspen City Offices at Galena Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Town Hall 35984 0.80 28823 28823Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Town Hall LED 1: A: 6" Downlight: Other:1 30 20 615 LED 2: B: Perimeter Fixture (per foot): Other:1 207 4 828 LED 3: C: 4' Strip: Other:1 102 32 3264 LED 4: D: 4' Stairwell: Other:1 13 48 624 LED 5: F: Narrow Depth Downlight: Other:1 6 15 90 LED 7: J: Stair Tape Light: Other:1 96 10 960 LED 6: Q: Pendant: Other:1 1 33 33 6414Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 78% better than code Project Title: Data filename: Aspen City Offices at Galena \\files\Corporate\Offices\Denver\MKK\01-Denver\2016.01.0223 & 2016.01.0224 Aspen City Hall - Galena Plaza & Rio Grande\Engr\Energy\2019-06-14_ComCheck.cck 03/10/20Report date: 81 ofPage Carrie Burgardt - Electrical Engineer 03/10/2020 COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Construction Site: 425 Rio Grande Place Aspen, CO 81611 Owner/Agent: City of Aspen 130 S. Galena Street Aspen, CO 81611 970-309-7638 jeff.pendarvis@cityofaspen.com Designer/Contractor: Shaw Construction 760 Horizon Drive Suite 201 Grand Junction, CO 81506 970-242-9236 brianthomas@shawconstruction.net Project Information Energy Code: Aspen City Offices at Galena 2 (Neighborhood business district)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Main entry 6 ft of door 20 Yes 120 Other door (not main entry)68 ft of door 20 Yes 1360 Stairway 1100 ft2 1 Yes 1100 Walkway < 10 feet wide 200 ft of 0.7 Yes 140 Entry canopy 850 ft2 0.25 Yes 212 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 2932 2932 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Main entry (6 ft of door width): Tradable Wattage LED 4 copy 1: SD: All per foot: Other:1 10 15 150 Other door (not main entry) (68 ft of door width): Tradable Wattage LED 1: SA: Other:1 18 27 486 Stairway (1100 ft2): Tradable Wattage LED 3: SC: Step Light: Other:1 33 8 264 Walkway < 10 feet wide (200 ft of walkway length): Tradable Wattage LED 2: SB: Other:1 15 11 165 Entry canopy (850 ft2): Tradable Wattage LED 4: SD: All per foot: Other:1 154 15 2310 3375Total Tradable Proposed Watts = Project Title: Data filename: Aspen City Offices at Galena \\files\Corporate\Offices\Denver\MKK\01-Denver\2016.01.0223 & 2016.01.0224 Aspen City Hall - Galena Plaza & Rio Grande\Engr\Energy\2019-06-14_ComCheck.cck 03/10/20Report date: 82 ofPage Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 4% better than code Project Title: Data filename: Aspen City Offices at Galena \\files\Corporate\Offices\Denver\MKK\01-Denver\2016.01.0223 & 2016.01.0224 Aspen City Hall - Galena Plaza & Rio Grande\Engr\Energy\2019-06-14_ComCheck.cck 03/10/20Report date: 83 ofPage Carrie Burgardt - Electrical Engineer 03/10/2020 03/10/2020 nickt COMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0016.2019.ACBK Location:Aspen, Colorado Climate Zone:7 Construction Site: 455 Rio Grande Place Aspen, CO 81611 Owner/Agent: City of Aspen 130 S. Galena Street Aspen, CO 81611 970-309-7638 jeff.pendarvis@cityofaspen.com Designer/Contractor: Shaw Construction 760 Horizon Drive Suite 201 Grand Junction, CO 81506 970-242-9236 brianthomas@shawconstruction.net Project Information Energy Code: Aspen City Office Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Building Area Floor Area 1-City of Aspen Office Building (Office) : Nonresidential 148 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1: Attic Roof with Steel Joists, [Bldg. Use 1 - City of Aspen Office Building] 141 40.0 0.0 0.033 0.021 NORTH MAIN 2: Solid Concrete:8" Thickness, Medium Density, Furring: None, [Bldg. Use 1 - City of Aspen Office Building] 152 ---20.0 0.045 0.071 Door 2: Uninsulated Single-Layer Metal, Non-Swinging, [Bldg. Use 1 - City of Aspen Office Building] 25 ------0.300 0.179 EAST MAIN 3: Solid Concrete:8" Thickness, Medium Density, Furring: None, [Bldg. Use 1 - City of Aspen Office Building] 128 ---20.0 0.045 0.071 Door 3: Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 24 ------0.300 0.370 SOUTH MAIN 4: Solid Concrete:8" Thickness, Medium Density, Furring: None, [Bldg. Use 1 - City of Aspen Office Building] 152 ---20.0 0.045 0.071 WEST MAIN 1: Solid Concrete:8" Thickness, Medium Density, Furring: None, [Bldg. Use 1 - City of Aspen Office Building] 128 ---20.0 0.045 0.071 Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - City of Aspen Office Building] 24 ------0.300 0.370 Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.455 Rio Grande Place.2020.03.02.cck 03/02/20Report date: 91 ofPage 03/06/2020 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 15% better than code Project Title: Data filename: Aspen City Office \\DC3\Projects\1836 Aspen City Offices\2_Design\COMCheck Envelope CALCULATOR\COMcheck Envelope.455 Rio Grande Place.2020.03.02.cck 03/02/20Report date: 92 ofPage (Rio Grande Building side of fire wall) 03/10/2020 nickt