Loading...
HomeMy WebLinkAboutFile Documents.802 W Main St.0170.2018 (33).ARBK aec Architectural Engineering Consultants, Inc. ` An Office with LEED TTMM Accredited Professionals 40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620 phone: 970-748-8520 email: stan@aec-vail.com web: www.aec-vail.com May 25, 2018 David Johnston David Johnston Architects 119 South Spring Street, Suite 203 Aspen, CO 81611 Re: Aspen Affordable Housing – 802 West Main Street Dear David, This document is intended to show compliance of the new construction of the Aspen Affordable Housing located at 802 West Main Street, Aspen, CO with the 2015 International Energy Conservation Code (2015 IECC). We propose to use a prescriptive approach per sections 402.1-402.3 and 403.2.1 of the 2015 IECC. Project The project at 802 West Main Street is the new construction of a multi-family residence with a floor area of 10,874.19 sf. For heat load calculations, please refer to the Appendix. The heat load calculations are performed using the Carrier Hourly Analysis Program and provides a more detailed and accurate load than Manual J. Building Envelope The following table lists the mandatory minimum insulation and fenestration requirements for the project climate zone (7). All new assemblies will meet the following requirements. Fenestration U-factor Ceiling R- value Wood frame wall R-value Floor R-value Basement wall R-value Slab R-value Code Minimums 0.28 (1) 49 20+5 or 13+10 38 (2) 15/19 (3) 10 (4) Notes: 1) Fenestration SHGC requirements do not apply in climate zone (7) 2) Or insulation sufficient to fill the framing cavity, R-19 minimum 3) R-15 continuous insulation on the interior or exterior or R-19 cavity insulation on the interior of the basement wall. Can be satisfied with R-13 cavity plus R-5 continuous. 4) 4 ft deep and R-15 edge insulation for heated slabs 5) R-10 continuous insulation or R-13 cavity insulation. Sincerely, Dan Findley Mechanical Engineer 06/15/2018 Zone Sizing Summary for Default System Project Name: 802 W Main Street Prepared by: AEC, Inc. 05/25/2018 07:53AM Hourly Analysis Program v4.50 Page 1 of 2 Air System Information Air System Name Default System Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 5060.0 ft² Location Aspen, Colorado Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Zone Sizing Data Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft²) Zone CFM/ft² Zone 1 86.3 5148 5148 Aug 1500 103.2 5060.0 1.02 Zone Terminal Sizing Data Space Loads and Airflows No Zone Terminal Sizing Data required for this system. Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft²) Space CFM/ft² Zone 1 001 MECHANICAL 1 1.7 Jul 1500 255 5.1 365.0 0.70 002 STORAGE 1 3.9 Aug 1500 657 13.2 785.0 0.84 102A LIVING ROOM 1 2.6 Aug 1600 113 2.3 155.0 0.73 102B DINING 1 5.8 Sep 1400 207 4.2 115.0 1.80 102C KITCHEN 1 1.5 Jul 1500 54 1.1 110.0 0.49 102D MUDROOM 1 0.6 Jul 1600 113 2.3 95.0 1.19 102E BEDROOM 1 1.8 Jul 1700 127 2.6 135.0 0.94 102F BATH 1 0.4 Jul 1500 15 0.3 60.0 0.24 103A LIVING ROOM 1 6.8 Sep 1400 257 5.1 125.0 2.05 103B DINING 1 2.2 Jul 1600 61 1.2 90.0 0.68 103C KITCHEN 1 2.4 Jul 1500 148 3.0 145.0 1.02 103D MUDROOM 1 0.3 Jul 1900 45 0.9 50.0 0.89 103E BEDROOM 1 2.4 Sep 1500 163 3.3 155.0 1.05 103F BATH 1 0.3 Jul 1500 12 0.2 50.0 0.24 105A LIVING ROOM 1 2.8 Jul 1500 154 3.1 175.0 0.88 105B DINING 1 5.0 Jul 1000 229 4.6 105.0 2.18 105C KITCHEN 1 1.4 Jul 1600 74 1.5 100.0 0.74 105D MUDROOM 1 0.8 Jul 1700 143 2.9 95.0 1.51 105E BEDROOM 1 3.0 Jul 1700 155 3.1 135.0 1.15 105F BATH 1 0.4 Jul 1500 18 0.4 60.0 0.30 201A LIVING ROOM 1 4.7 Oct 1400 156 3.1 155.0 1.00 201B DINING 1 6.1 Sep 1500 205 4.1 115.0 1.78 201C KITCHEN 1 1.7 Jul 1800 69 1.4 110.0 0.63 201D MUDROOM 1 0.7 Jul 1800 127 2.5 95.0 1.33 201E BEDROOM 1 1.9 Jul 1700 139 2.8 135.0 1.03 201F BATH 1 0.4 Jul 1600 24 0.5 60.0 0.39 203A LIVING ROOM 1 6.4 Sep 1400 239 4.8 125.0 1.91 203B DINING 1 3.2 Jul 1400 95 1.9 90.0 1.05 203C KITCHEN 1 2.6 Jul 1600 155 3.1 145.0 1.07 203D MUDROOM 1 0.4 Jul 1900 44 0.9 50.0 0.89 203E BEDROOM 1 2.5 Sep 1500 161 3.2 155.0 1.04 203F BATH 1 0.4 Jul 1600 20 0.4 50.0 0.39 205A LIVING ROOM 1 4.3 Jul 1400 161 3.2 175.0 0.92 06/15/2018 Zone Sizing Summary for Default System Project Name: 802 W Main Street Prepared by: AEC, Inc. 05/25/2018 07:53AM Hourly Analysis Program v4.50 Page 2 of 2 Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft²) Space CFM/ft² 205B DINING 1 4.6 Jul 1400 199 4.0 105.0 1.90 205C KITCHEN 1 1.6 Jul 1700 67 1.3 100.0 0.67 205D MUDROOM 1 0.8 Jul 1700 126 2.5 95.0 1.33 205E BEDROOM 1 3.1 Jul 1700 139 2.8 135.0 1.03 205F BATH 1 0.4 Jul 1700 24 0.5 60.0 0.39 Notes: Loads were calculated for three residences per level. Typical conditions exist for the remaining three residences per level. MANUAL J DESIGN CONDITIONS WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS OUTDOOR TEMPERATURE -15 °F OUTDOOR TEMPERATURE 82 °F INDOOR TEMPERATURE 70 °F INDOOR TEMPERATURE 75 °F TOTAL HEAT LOSS 190,751 BTU/HR SENSIBLE HEAT GAIN 178,554 BTU/HR LATENT HEAT GAIN 19,796 BTU/HR TOTAL HEAT GAIN 198,350 BTU/HR 06/15/2018