HomeMy WebLinkAboutFile Documents.802 W Main St.0170.2018 (42).ARBKCO
A
AF
F
O
R
D
A
B
L
E
HO
U
S
I
N
G
80
2
WE
S
T
MA
I
N
ST
. AS
P
E
N
,
CO
DRAWING ISSUE
DRAWN BY:
PROJECT No:1702
PERMIT 06/14/18
10/24/2019
BID 10/19/18
100% CDs 03/15/19
CA
CPF
All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
G1.12
FIRE SEPARATION
Sheet No.
2
6.3
W2
W2
W1
W7
W5.1
W2
W2
W2
W2
W2
W2
W2W2
W2
W2
W2
W2
W2
W2
W2
W2
W2
W2
W2W5.1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17DOWN
UPW6.1
W2
W2
W2
1
1
A A
3
3
7
7
10
10
9
9
11
11
14
14
16
16
15
15
12
12
5
5
E E
J J
N N
M M
G G
H H
C C
2
2
B B
8
8
D D
F F
K K
L L
13
13
4
4
6
6
12345678
DN UP
3
6.3
4'-01/2"
4'-61/2"
2'
-
6
"
3'-6"2'-6"
PROPERTY LINE
PROPERTY LINE
SETBACK LINE
SETBACK LINE
SETBACK LINE
W6
W8
W6
W6W3
W3
W5
W5
W5
W3
W3.1
W3.1
W3
W5
W3
W6
W8
W6
W6
W6
W6.1
W3
W3
W4
W5.1
W3.1
W6 W6
W6
W6
W6
W5W5
W6
W6
W4
SEE 9/7.3
SEE 9/7.3
SEE 9/7.3
SEE 9/7.3
SEE 9/7.3
DRW
DRW
DR
W
DR
W
DR
W
REF
REF REF
RE
F
RE
F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17DOWN
UP18
19
20
21
22
23
24
UP
1
1
A A
3
3
7
7
10
10
9
9
11
11
14
14
16
16
15
15
12
12
5
5
E E
J J
N N
M M
G G
H H
C C
2
2
B B
8
8
D D
F F
K K
L L
13
13
4
4
6
6
W3.1
W6.1
W3.1
W6.1
1 HR RATED WALL
1 HR RATED FLOOR/
CEILING ASSEMBLY
FIRE SEPARATION KEY
1/2 HR RATED WALL
0 4'8'16'SCALE: 1/8" = 1'-0"-1 BASEMENT/ FOUNDATIONS FIRE SEPARATION
0 4'8'16'SCALE: 1/8" = 1'-0"1 MAIN LEVEL FIRE SEPARATION
10/30/2019
10/30/2019
nickt
CO
A
AF
F
O
R
D
A
B
L
E
HO
U
S
I
N
G
80
2
WE
S
T
MA
I
N
ST
. AS
P
E
N
,
CO
DRAWING ISSUE
DRAWN BY:
PROJECT No:1702
PERMIT 06/14/18
10/24/2019
BID 10/19/18
100% CDs 03/15/19
CA
CPF
All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
G1.13
FIRE SEPERATION
Sheet No.
1234567891011121314151617181920
DN UP
4
6.3
4
6.4
5'-1"
W3.1
W3.1
W6
W5
W6
W5
W6
W6W3
W5
W5
W5
W3.2
W5.2
W5.2
W3
W6.1
W3.1
W6
W5
W6
W5
W6
W6.1
W3
W4
W3
W6
W6
W6
W6
W4
W5
W5.2
W3.2 W4
W6
W6
W6
W3.1
W9
SEE 9/7.3
SEE 9/7.3
SEE 9/7.3
SEE 9/7.3
SEE 9/7.3
DR
DRW
DRW
W
DR
W
DR
W
RE
F
REFREF
RE
F
REF
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35DOWN
UP
1
1
A A
3
3
7
7
10
10
9
9
11
11
14
14
16
16
15
15
12
12
5
5
E E
J J
N N
M M
G G
H H
C C
2
2
B B
8
8
D D
F F
K K
L L
13
13
4
4
6
6
W3.1
A B C D E F G H J K L M N
19.47 sq ft
19.47 sq ft
MAIN LEVEL T.O. PLY.
100'-0"
SECOND LEVEL T.O. PLY.
110'-5"
382.81 sq ft
22.00 sq ft
22.00 sq ft
447.18 sq ft
1 HR RATED WALL
1 HR RATED FLOOR/
CEILING ASSEMBLY
FIRE SEPARATION KEY
MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON
FIRE SEPARATION DISTANCE AND DEGREE OF PROTECTION
3' TO LESS THAN 5'UP, S 15%
WALL AREA OPENING AREA PERCENT OF OPEN AREA
MAIN LVL 382.81 SF 41.47 SF 10%
1/2 HR RATED WALL
UPPER LVL 447.18 SF 41.47 SF 9%
0 4'8'16'SCALE: 1/8" = 1'-0"2 SECOND LEVEL FIRE SEPARATION
0 4'8'16'SCALE: 1/8" = 1'-0"A WEST ELEVATION FIRE SEPARATION
10/30/2019
10/30/2019
nickt
CO
A
AF
F
O
R
D
A
B
L
E
HO
U
S
I
N
G
80
2
WE
S
T
MA
I
N
ST
. AS
P
E
N
,
CO
DRAWING ISSUE
DRAWN BY:
PROJECT No:1702
PERMIT 06/14/18
10/24/2019
BID 10/19/18
100% CDs 03/15/19
CA
CPF
All ideas, designs, arrangements and plans
indicated or represented by this drawing are
owned by and are the property of David Johnston
Architects, PC and developed for use and in
conjunction with the specified project. None
of the ideas, designs, arrangements or plans
shall be used by or disclosed for any purpose
whatsoever without the written authorization
of David Johnston Architects, PC.
119 South Spring St.
Suite 203
Aspen, CO 81611
970-925-3444
970-920-2186
TEL
FAX
7.3
WALL DETAILS
Sheet No.
2"SEE PLAN
5/8"
11
7/8"
3/4"
3/4"
51/2"
10"
3/4"
3/4"
51/2"
10"
1/2"
1/2"
1/2"
SE
E
ST
R
U
C
T
.
3/4"
3"
@T
H
R
E
S
H
O
L
D
5/8"
11
7/8"
3/4"
3/4"
51/2"
11
/16
"
1/2"
51/2"
1/2"
11
/16
"
755
/64
"
11/2"
11/2"
3/4"
1/2"
31/2"
1/2"
3/4"
6"
8"
4"
1/16
"
3"
61/2"
FOUNDATION
WATERPROOFING &
DRAINAGE MAT
4" DIAMETER A.B.S
PERFORATED FOUNDATION
DRAIN-GRAVEL FILL
ADJACENT TO FOUNDATION
WALL TO EXTEND TO
PERIMETER DRAINS, RE:
CIVIL
FIBERGLASS FILTER CLOTHFREE-DRAINING GRANULAR
MATERIAL-SEE GEOTECH REPORT
NO SLAB AT
CRAWLSPACE-GRAVEL
W/ CLASS 1 VAPOR
RETARDER
WATER-RESISTIVE BARRIER
TO LAP OVER TREMCO
FLASHING
FLUID-APPLIED
WATERPROOFING TO
EXTEND 6" MIN. ONTO
SELF-ADHERING
TRANSITION MEMBRANE
18" STRIP OF TREMCO
EXOAIR 111-EXTEND 12" UP
WALL AND 4" LAP WITH
WATER BARRIER
COMPOSITE PANEL FASCIA
FLASHING
5/8" TYPE X GYP BOARD
SLOPE TO DRAIN
1/8"/FT
DENGLASS SOFFIT - PAINTED
SEE SPEC
RESILIENT CHANNEL
FLASHING
AIR SPACE
SEALANT
WATER-RESISTIVE BARRIER
TO LAP OVER TREMCO
FLASHING
FLUID-APPLIED
WATERPROOFING TO
EXTEND 6" MIN. ONTO
SELF-ADHERING
TRANSITION MEMBRANE
18" STRIP OF TREMCO
EXOAIR 111-EXTEND 12" UP
WALL AND 4" LAP WITH
WATER BARRIER
SEALANT
FLASHING
WATER-RESISTIVE BARRIER
TO OVERLAP FLASHING
DOOR JAMB (TYP.)
BACKER ROD AND CAULK
1x CORNER TRIM
2X6 STUD FRAMING
(LONG WALL ONLY)
2X4 STUD FRAMING
(SHORT WALL ONLY)
1x2 TRIM
1x CORNER TRIM
T-FLASHING-SIDE AND TOP
W/ 1/8" REVEAL
FLASHING CAP
WATER BARRIER-WRAPPED BOTH SIDES
WOOD CAP
2X6 WALL
STEEL GUARDRAIL
METAL ENTRY DOOR JAMB
CORNER BRICK
CORNER BRICK
JAMB @ STAIR7.3 1 1/2" WALL DETAIL & ASSEMBLY TEMPLATE
1 TYPICAL FOOTER CONDITION
1 ½" = 1'-0"
1 ½" = 1'-0"
MAIN FLOOR/FOUNDATION WALL @ PATIO2
GL
1 ½" = 1'-0"
MAIN FLOOR/FOUNDATION WALL @ GRADE3
GL
DECK EDGE DETAIL @ WEST P.L.
1 ½" = 1'-0"
T. O. FIN. FLOOR
SEE PLAN
T. O. PLYWOOD
SEE PLAN
4
1 ½" = 1'-0"
STUCCO/BRICK TRANSITION5
GL
1 ½" = 1'-0"
DECK WALL DETAIL (PLAN)6
GL
DECK EDGE DETAIL @ SCUPPER
1 ½" = 1'-0"
T. O. FIN. FLOOR
SEE PLAN
T. O. PLYWOOD
SEE PLAN
7
GL
1 ½" = 1'-0"
BRICK WALL JAMB DETAILS (PLAN)8
GL
GL
1 ½" = 1'-0"9 1 HR RATED WALL-FLR/CLG CONDITION
NOTE:
ANY PENETRATIONS TO MEET 1 HOUR FIRE RATING
STANDARDS
NOTE: PENETRATIONS OF FIRE-RATED ASSEMBLIES
MUST BE PROTECTED PER 713. (SEE MECH. DRAWINGS
FOR DETAILS)
GL
NON COMBUSTABLE FRAMING FOR
DROPPED CEILINGS-SEE RCPS FOR
LOCATIONS
INTERIOR FIRERATING MOVES TO THE
FURRING WALL AT CERTAIN
LOCATIONS (SEE G1.13)
W2
W6
W2
F8F7
W6
W2
F7
F9
F5
W5
W8
F7
W9
W9
W6
F5
W9
W8
W8
W3.1
W3.1 F1
10/30/2019
10/30/2019
nickt