Loading...
HomeMy WebLinkAboutFile Documents.802 W Main St.0170.2018 (43).ARBKCO A AF F O R D A B L E HO U S I N G 80 2 WE S T MA I N ST . AS P E N , CO DRAWING ISSUE DRAWN BY: PROJECT No:1702 PERMIT 06/14/18 10/24/2019 BID 10/19/18 100% CDs 03/15/19 CA CPF All ideas, designs, arrangements and plans indicated or represented by this drawing are owned by and are the property of David Johnston Architects, PC and developed for use and in conjunction with the specified project. None of the ideas, designs, arrangements or plans shall be used by or disclosed for any purpose whatsoever without the written authorization of David Johnston Architects, PC. 119 South Spring St. Suite 203 Aspen, CO 81611 970-925-3444 970-920-2186 TEL FAX G1.12 FIRE SEPARATION Sheet No. 2 6.3 W2 W2 W1 W7 W5.1 W2 W2 W2 W2 W2 W2 W2W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2W5.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17DOWN UPW6.1 W2 W2 W2 1 1 A A 3 3 7 7 10 10 9 9 11 11 14 14 16 16 15 15 12 12 5 5 E E J J N N M M G G H H C C 2 2 B B 8 8 D D F F K K L L 13 13 4 4 6 6 12345678 DN UP 3 6.3 4'-01/2" 4'-61/2" 2' - 6 " 3'-6"2'-6" PROPERTY LINE PROPERTY LINE SETBACK LINE SETBACK LINE SETBACK LINE W6 W8 W6 W6W3 W3 W5 W5 W5 W3 W3.1 W3.1 W3 W5 W3 W6 W8 W6 W6 W6 W6.1 W3 W3 W4 W5.1 W3.1 W6 W6 W6 W6 W6 W5W5 W6 W6 W4 SEE 9/7.3 SEE 9/7.3 SEE 9/7.3 SEE 9/7.3 SEE 9/7.3 DRW DRW DR W DR W DR W REF REF REF RE F RE F 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17DOWN UP18 19 20 21 22 23 24 UP 1 1 A A 3 3 7 7 10 10 9 9 11 11 14 14 16 16 15 15 12 12 5 5 E E J J N N M M G G H H C C 2 2 B B 8 8 D D F F K K L L 13 13 4 4 6 6 W3.1 W6.1 W3.1 W6.1 1 HR RATED WALL 1 HR RATED FLOOR/ CEILING ASSEMBLY FIRE SEPARATION KEY 1/2 HR RATED WALL 0 4'8'16'SCALE: 1/8" = 1'-0"-1 BASEMENT/ FOUNDATIONS FIRE SEPARATION 0 4'8'16'SCALE: 1/8" = 1'-0"1 MAIN LEVEL FIRE SEPARATION 10/30/2019 10/30/2019 nickt CO A AF F O R D A B L E HO U S I N G 80 2 WE S T MA I N ST . AS P E N , CO DRAWING ISSUE DRAWN BY: PROJECT No:1702 PERMIT 06/14/18 10/24/2019 BID 10/19/18 100% CDs 03/15/19 CA CPF All ideas, designs, arrangements and plans indicated or represented by this drawing are owned by and are the property of David Johnston Architects, PC and developed for use and in conjunction with the specified project. None of the ideas, designs, arrangements or plans shall be used by or disclosed for any purpose whatsoever without the written authorization of David Johnston Architects, PC. 119 South Spring St. Suite 203 Aspen, CO 81611 970-925-3444 970-920-2186 TEL FAX G1.13 FIRE SEPERATION Sheet No. 1234567891011121314151617181920 DN UP 4 6.3 4 6.4 5'-1" W3.1 W3.1 W6 W5 W6 W5 W6 W6W3 W5 W5 W5 W3.2 W5.2 W5.2 W3 W6.1 W3.1 W6 W5 W6 W5 W6 W6.1 W3 W4 W3 W6 W6 W6 W6 W4 W5 W5.2 W3.2 W4 W6 W6 W6 W3.1 W9 SEE 9/7.3 SEE 9/7.3 SEE 9/7.3 SEE 9/7.3 SEE 9/7.3 DR DRW DRW W DR W DR W RE F REFREF RE F REF 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35DOWN UP 1 1 A A 3 3 7 7 10 10 9 9 11 11 14 14 16 16 15 15 12 12 5 5 E E J J N N M M G G H H C C 2 2 B B 8 8 D D F F K K L L 13 13 4 4 6 6 W3.1 A B C D E F G H J K L M N 19.47 sq ft 19.47 sq ft MAIN LEVEL T.O. PLY. 100'-0" SECOND LEVEL T.O. PLY. 110'-5" 382.81 sq ft 22.00 sq ft 22.00 sq ft 447.18 sq ft 1 HR RATED WALL 1 HR RATED FLOOR/ CEILING ASSEMBLY FIRE SEPARATION KEY MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF PROTECTION 3' TO LESS THAN 5'UP, S 15% WALL AREA OPENING AREA PERCENT OF OPEN AREA MAIN LVL 382.81 SF 41.47 SF 10% 1/2 HR RATED WALL UPPER LVL 447.18 SF 41.47 SF 9% 0 4'8'16'SCALE: 1/8" = 1'-0"2 SECOND LEVEL FIRE SEPARATION 0 4'8'16'SCALE: 1/8" = 1'-0"A WEST ELEVATION FIRE SEPARATION 10/30/2019 10/30/2019 nickt CO A AF F O R D A B L E HO U S I N G 80 2 WE S T MA I N ST . AS P E N , CO DRAWING ISSUE DRAWN BY: PROJECT No:1702 PERMIT 06/14/18 10/24/2019 BID 10/19/18 100% CDs 03/15/19 CA CPF All ideas, designs, arrangements and plans indicated or represented by this drawing are owned by and are the property of David Johnston Architects, PC and developed for use and in conjunction with the specified project. None of the ideas, designs, arrangements or plans shall be used by or disclosed for any purpose whatsoever without the written authorization of David Johnston Architects, PC. 119 South Spring St. Suite 203 Aspen, CO 81611 970-925-3444 970-920-2186 TEL FAX 7.3 WALL DETAILS Sheet No. 2"SEE PLAN 5/8" 11 7/8" 3/4" 3/4" 51/2" 10" 3/4" 3/4" 51/2" 10" 1/2" 1/2" 1/2" SE E ST R U C T . 3/4" 3" @T H R E S H O L D 5/8" 11 7/8" 3/4" 3/4" 51/2" 11 /16 " 1/2" 51/2" 1/2" 11 /16 " 755 /64 " 11/2" 11/2" 3/4" 1/2" 31/2" 1/2" 3/4" 6" 8" 4" 1/16 " 3" 61/2" FOUNDATION WATERPROOFING & DRAINAGE MAT 4" DIAMETER A.B.S PERFORATED FOUNDATION DRAIN-GRAVEL FILL ADJACENT TO FOUNDATION WALL TO EXTEND TO PERIMETER DRAINS, RE: CIVIL FIBERGLASS FILTER CLOTHFREE-DRAINING GRANULAR MATERIAL-SEE GEOTECH REPORT NO SLAB AT CRAWLSPACE-GRAVEL W/ CLASS 1 VAPOR RETARDER WATER-RESISTIVE BARRIER TO LAP OVER TREMCO FLASHING FLUID-APPLIED WATERPROOFING TO EXTEND 6" MIN. ONTO SELF-ADHERING TRANSITION MEMBRANE 18" STRIP OF TREMCO EXOAIR 111-EXTEND 12" UP WALL AND 4" LAP WITH WATER BARRIER COMPOSITE PANEL FASCIA FLASHING 5/8" TYPE X GYP BOARD SLOPE TO DRAIN 1/8"/FT DENGLASS SOFFIT - PAINTED SEE SPEC RESILIENT CHANNEL FLASHING AIR SPACE SEALANT WATER-RESISTIVE BARRIER TO LAP OVER TREMCO FLASHING FLUID-APPLIED WATERPROOFING TO EXTEND 6" MIN. ONTO SELF-ADHERING TRANSITION MEMBRANE 18" STRIP OF TREMCO EXOAIR 111-EXTEND 12" UP WALL AND 4" LAP WITH WATER BARRIER SEALANT FLASHING WATER-RESISTIVE BARRIER TO OVERLAP FLASHING DOOR JAMB (TYP.) BACKER ROD AND CAULK 1x CORNER TRIM 2X6 STUD FRAMING (LONG WALL ONLY) 2X4 STUD FRAMING (SHORT WALL ONLY) 1x2 TRIM 1x CORNER TRIM T-FLASHING-SIDE AND TOP W/ 1/8" REVEAL FLASHING CAP WATER BARRIER-WRAPPED BOTH SIDES WOOD CAP 2X6 WALL STEEL GUARDRAIL METAL ENTRY DOOR JAMB CORNER BRICK CORNER BRICK JAMB @ STAIR7.3 1 1/2" WALL DETAIL & ASSEMBLY TEMPLATE 1 TYPICAL FOOTER CONDITION 1 ½" = 1'-0" 1 ½" = 1'-0" MAIN FLOOR/FOUNDATION WALL @ PATIO2 GL 1 ½" = 1'-0" MAIN FLOOR/FOUNDATION WALL @ GRADE3 GL DECK EDGE DETAIL @ WEST P.L. 1 ½" = 1'-0" T. O. FIN. FLOOR SEE PLAN T. O. PLYWOOD SEE PLAN 4 1 ½" = 1'-0" STUCCO/BRICK TRANSITION5 GL 1 ½" = 1'-0" DECK WALL DETAIL (PLAN)6 GL DECK EDGE DETAIL @ SCUPPER 1 ½" = 1'-0" T. O. FIN. FLOOR SEE PLAN T. O. PLYWOOD SEE PLAN 7 GL 1 ½" = 1'-0" BRICK WALL JAMB DETAILS (PLAN)8 GL GL 1 ½" = 1'-0"9 1 HR RATED WALL-FLR/CLG CONDITION NOTE: ANY PENETRATIONS TO MEET 1 HOUR FIRE RATING STANDARDS NOTE: PENETRATIONS OF FIRE-RATED ASSEMBLIES MUST BE PROTECTED PER 713. (SEE MECH. DRAWINGS FOR DETAILS) GL NON COMBUSTABLE FRAMING FOR DROPPED CEILINGS-SEE RCPS FOR LOCATIONS INTERIOR FIRERATING MOVES TO THE FURRING WALL AT CERTAIN LOCATIONS (SEE G1.13) W2 W6 W2 F8F7 W6 W2 F7 F9 F5 W5 W8 F7 W9 W9 W6 F5 W9 W8 W8 W3.1 W3.1 F1 10/30/2019 10/30/2019 nickt