Loading...
HomeMy WebLinkAboutFile Documents.230 E Hopkins Ave.0089.2018 (54).ACBKCOMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 90.1 (2013) Standard Project Type:Alteration Construction Site: 200-234 E. HOPKINS ASPEN, CO 81611 Owner/Agent: Jonathan Rice Rowland & Broughton 500 West Main Street Aspen, CO 81611 970-544-9006 jonathan.rice@rowlandbroughton.c om Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com Project Information Energy Code: MOUNTAIN FORGE TENANT FINISH Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 2-#4 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)1585 1.11 1759 3-#6 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)520 1.11 577 1-#1 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)1336 1.11 1483 4-#3 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)655 1.11 727 5-#7 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)485 1.11 538 6-#5 COMMERCIAL (Common Space Types:Office - Enclosed)133 1.11 148 7-#2 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)340 1.11 377 5610Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures #4 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 1585 sq.ft.) LED 1: R3 & R4: DOWNLIGHT: Other:1 27 13 351 LED 2: P2: PENDENT AT BATHROOM: Other:1 4 60 240 LED 3: P3: PENDENT AT BATHROOM: Other:1 2 75 150 LED 4: T1: LED STRIP AT UTILITY: Other:1 1 32 32 LED 5: S2 & S3: SCONCE: Other:1 5 20 100 LED 7: C1: PENDANT AT POOL TABLE: Other:1 1 45 45 LED 5: S4: SCONCE: Other:1 1 20 20 Track lighting 3: TR1 & TR2: TRACK LIGHTING: Wattage based on 12 feet of track 0 0 360 360 #6 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 520 sq.ft.) LED 7: R3: DOWNLIGHT: Other:1 10 13 130 LED 8: S4: SCONCE: Other:1 10 20 200 LED 9: S4: LED STRIP AT UTILITY: Other:1 1 32 32 #1 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 1336 sq.ft.) LED 9: R3: DOWNLIGHT: Other:1 27 13 351 LED 20: UC4: UNDERCABINET (1.5 W / LFT): Other:1 9 2 14 Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/26/21Report date: 61 ofPage 04/07/2021 E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Track lighting 2: TR4: TRACK LIGHTING: Wattage based on 16 feet of track 0 0 480 480 LED 22: P10: PENDANT LIGHTING: Other:1 2 18 36 #3 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 655 sq.ft.) LED 11: R3: DOWNLIGHT: Other:1 13 13 169 LED 12: P11: PENDANTS: Other:1 2 69 138 #7 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 485 sq.ft.) LED 13: R3: DOWNLIGHT: Other:1 13 13 169 LED 14: P9: PENDANT: Other:1 4 40 160 LED 15: UC3: UNDERCABINET(1.5 W / LFT): LED Undercabinet Unit 4W:1 5 2 8 #5 COMMERCIAL ( Common Space Types:Office - Enclosed 133 sq.ft.) LED 18: T1: LED STRIP: Other:1 2 32 64 #2 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 340 sq.ft.) LED 21: R9: DOWNLIGHT: Other:1 4 8 30 LED 21: CV2: COVE LIGHTING: Other:1 9 2 14 Track lighting 1: TR3: TRACK LIGHTING: Wattage based on 14 feet of track 0 0 420 420 3712Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/26/21Report date: 62 ofPage ZACHARY GAINS 03/26/2021 04/12/2021 nickt Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.1.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2013) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2, 8.4.1.1, 8.4.1.2, 8.7 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable 4.2.2, 9.4.3, 9.7 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/26/21Report date: 63 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions 8.4.2 [EL10]2 At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Complies Does Not Not Observable Not Applicable 9.4.1.1 [EL1]2 Automatic control requirements prescribed in Table 9.6.1, for the appropriate space type, are installed. Mandatory lighting controls (labeled as 'REQ') and optional choice controls (labeled as 'ADD1' and 'ADD2') are implemented. Complies Does Not Not Observable Not Applicable 9.4.1.1 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable 9.4.1.2 [EL11]2 Parking garage lighting is equipped with required lighting controls and daylight transition zone lighting. Complies Does Not Not Observable Not Applicable 9.4.1.1f [EL13]1 Daylight areas under skylights and roof monitors that have more than 150 W combined input power for general lighting are controlled by photocontrols. Complies Does Not Not Observable Not Applicable 9.4.1.3 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/26/21Report date: 64 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/26/21Report date: 65 ofPage Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/26/21Report date: 66 ofPage