HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (53).ACBK        March 6, 2020    City of Aspen Building Department  C/O Rich Pavcek  Charles Cunniffe Architects  610 East Hyman Ave.  Aspen, Colorado 81611    REF:    Pilkington Profilit™ Channel Glass System   Aspen City Offices    Dear Mr. Pavcek,    Please accept this letter of confirmation that product selected* for the above referenced project will meet the NFRC  performance requirements as set forth in the previously submitted National Certified Testing Laboratories test report  NCTL‐110‐14134‐01 dated September 28, 2011.     * Dual Glazed K32/60/7 Standard Cast over K32/60/7 Standard Cast channel glass with 25mm Lumira insulation in the  K60 series thermally broken frame system.  U value:  0.27.    The product design, materials of construction, and sourcing have remained unchanged.  It should be noted that while  the required minimum insulation thickness to achieve this U‐value is 20mm, TGP supplies the Lumira insulation in 16mm  and 25mm nominal thicknesses; with the latter being the selection required to reach the desired value.    Sincerely,    Ron Madeley  Principal Engineer  ronald.madeley@allegion.com   425‐396‐8264    cc:  Sean Williams, TGP | Allegion  03/06/2020