HomeMy WebLinkAboutFile Documents.209 E Bleeker St.0320.2017 (146).ARBKGasKnockout 8-5/8"[219] 9-5/8"[244] 9-1/2"[241] OutsideAir 9-1/4"[235] GasKnockout 18-1/2"[470] 8-5/8"[219] 49-5/8"[1260]28-1/2"[724] 55-1/2"[1410]effectiveheight 49-1/8"[1248] 59-1/4"[1505] 7-5/8"[194] 36"[914] 28-5/8"[727] 14-3/8"[365] 44-1/2"[1130] 27-1/2"[699] 9-1/2"[241] Top View Front View Left Side View Right Side View * Framing must be filled in to top of front standoff after unit is installed. Specifications Additional information can be found online at www.majesticproducts.com or www.fireplaces.com SB60 Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision. BILTMORE 60 36" Wood Fireplace MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH FIREPLACE OPENING SB60 Actual Framing Actual Framing Actual Rough Opening Framing* Actual Framing 36" x 28-1/2" 44-1/2"45-1/2"28-5/8"45-1/2"59-1/4"59-3/4"27-1/2"28" 01/08/2018 CLEARANCES TO COMBUSTIBLES FRAMING DIMENSIONS MANTEL LEG/WALL PROJECTIONS HEARTH EXTENSION CONSTRUCTION APPLIANCE LOCATION MANTEL PROJECTIONS HEARTH EXTENSIONS 60-1/8" [1527] 42-1/2"[1080] 19-3/8"[492] 45-1/2"[1156] 1/2" [13] allconfigurations In an exteriorchase or projectinginto a garage Across acorner As a roomdivider Along a wall 53-1/2"[1359] 45-1/2"[1156] 28"[711] 28"[711] 28"[711] 53-1/2" [1359]45-1/2" [1156] 53-1/2" [1359]45-1/2" [1156] 48"[1219]min. 24"[610] 24"[610] 24"[610] 85"[2159] **28"[711] 45-1/2"[1156] Header MUST NOT be notched! *8"[203] * 4" duct. Extra space needed for outside air connection. If outside air duct has no bend, this dimension may be reduced as long as minimum clearances are met. Header will sit on top of front stand offs after fireplace is installed. ** If interior of chase will be drywalled, add the thickness to this measurement 2" [51] 17"[432] 36" [914] 24"[610] 24"[610] 19-3/4"[502] 22-3/8"[568] FLUSHFRONT 4"[102]BRICKFRONT 50° a n g l e 39 ° a n g l e Grid represents1" scale 44-1/2" [1130] 2" [51]required Continuous, non-combustable sealant Tile, stone or othernon-combustible material Floor constructed of wood or other combustiblematerial HX4 Hearth Extor equivalent insulation.See install manual Fi r e p l a c e ProtectiveMetal HearthStrip 60" [1524] 20"[508]12"[305] (insulation) 0" to level ofstandoffs AtticInsulationShield (ceiling) (roof) (attic) (ceiling) Ceiling Firestop Offset/Return (securedwith hanger straps) Storm Collar Roof Flashing Back & sides of unit1" [25] (except at nailflanges where it is 1/2" [13] Must have 2" [51] minimumclearance to header 0" to floor 2" [51] min. Shaded areas represent2" [51] minimum air spaceclerance required aroundpipe. Co m b u s t i b l e O b j e c t 48"[1219] Adapter attached here (not shown) 7 ft [2134]minimum baseof fireplaceto ceiling Combustible Wall 2 x 4 stud wall Standoffs Measured from top of fireplace opening 12" [305] 12" [305]minimum 1-1/2" [38]maximum 6" [152]mimimum CombustibleDecorative Facing Seal joint withnon-combustiblesealant NoncombustibleDecorative Facingsuch as: stell, iron,brick, tile, concrete,slate, glass, plasters 1/2" [13] Fireplace must be set out 1/2 [13] in front of the face of the framing material. Specifications MAJ/SB60_0817 PRODUCT LISTING CODES US UL 127 CAN ULC-S610 Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury. Additional information can be found online at www.majesticproducts.com Lakeville, MN Phone: (800) 927-6841 Web: www.majesticproducts.com SB60 01/08/2018