Loading...
HomeMy WebLinkAboutFile Documents.834 W Hallam St.0025-2021-BCHO (24) The Mozingo Code Group, LLC 261 W 79th Ct Denver, CO 80221 sdmozingo@mozingocodegroup.com PLAN REVIEW REPORT PROJECT Change order- R2 PROJECT LOCATION 834 W Hallam St, Aspen, CO DATE OF REVIEW 10/12/2021 REVIEW BASED ON PLANS DATED 05/06/21 REVIEW CONTACT Shaunna Mozingo sdmozingo@mozingocodegroup.com 2 | Page Mozingo Code Group, LLC PROJECT INFORMATION ARCHITECT: Forum Phi STRUCTURAL ENGINEER: KL&A MECHANICAL ENGINEER: ELECTRICAL ENGINEER: CODES USED FOR REVIEW 2015 International Building Code 2015 International Mechanical Code 2015 International Plumbing Code 2015 International Energy Conservation Code 2020 National Electrical Code BUILDING INFORMATION Occupancy Classification: R-2 Type of Construction: VB Total Floor Area: Height (Stories/Feet): Notice This cursory plan review is based on the codes noted herein and represents a list of corrections necessary to comply with the requirements contained within them. This review is not a building permit. The local jurisdiction is responsible for issuing the appropriate permits based on this review. The approval of plans and specifications does not permit the violation of any section of any federal, state or local regulations. All comments in this report are based on the information provided on the drawings and supporting documentation provided for review. The Mozingo Code Group, LLC does not accept any responsibility for any condition that was not known at the time of this report. We reserve the right to amend this report if additional information is received. This report does not purport to review, interpret, apply, or certify compliance with the accessibility requirements set forth within the Americans with Disabilities Act (ADA). The application, interpretation and enforcement of the ADA are vested with the Federal Department of Justice. Applicants are encouraged to seek professional review to ensure compliance with the ADA. 3 | Page Mozingo Code Group, LLC REVIEW COMMENTS The items noted below with a comment number (B-1, B-2 etc.) are items that need to be corrected to show compliance with the applicable codes. Please provide a written response indicating where the corrections are made on the plans. This will speed up the review process. Additional comments may be forthcoming once all revisions are received for review. BUILDING CODE COMMENTS B-1 Refer to Sheet A102: There is a new exterior Wall Type 11 called out on the west side of buildings A & B. There are no details to identify what Wall Type 11 is. On the original approved plan set, Sheet A501 Assemblies, the wall types go through Type 10. Please provide details for Wall Type 11. STRUCTURAL COMMENTS The scope of this review is limited to the structural plans provided. Structural Plan Comments: S-1 Sheet S-102: At roughly grid intersection G.5-3, there is a jog in a lower bearing wall and foundation that would no longer provide support for the framing condition shown in section 1/S-405. Please clarify or revise support. S-2 Sheet S-402, Section 9: It does not appear the cantilevered framing supporting a 2” concrete topping has sufficient attachment to support applicable loading. Please review and verify this condition is structurally stable. City of Aspen Comments: A-1 Sheet S-102 is still showing the sheathing on the inside of the exterior wall on the historic resource. Please update to show the as -built condition with the sheathing on the outside of the framing. A-2 Please provide the updated stamped mechanical drawings showing the locations of the ceiling radiation dampers and protection of the ERV supply the penetrates the fir e partition at the dwelling separation .