Loading...
HomeMy WebLinkAboutFile Documents.230 E Hopkins Ave.0089.2018 (57).ACBKMtn Forge additional info 3-24-21 building comments 1 Subject: Lighting controls and comcheck Page: [3] 18009 e1-E3.1 Page Index: 3 Author: nickt Color: File Name: 18009 MTN Forge Sheet E13_E14_E31 Lighting and Panel Update Revision #18.pdf Specifically demonstrate compliance with the provisions of 2015 IECC C405, including: -Revise lighting plans to show all lighting control requirements including: -Time switch controls -Light-reduction controls -Daylight-responsive controls -Exterior lighting controls 18009 MTN Forge Sheet E13_E14_E31 Lighting and Panel Update Revision #18.pdf (1) Subject: PlanCheck Page: 1 Page Index: 1 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf Fill out owner/agent Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf (8) Subject: PlanCheck Page: 1 Page Index: 1 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf Track lights must be at least 30 W/linear ft., or the wattage limit of the system’s circuit breaker, or the wattage limit of other permanent current-limiting devices on the system. 2015 IECC C405.4.1 Subject: PlanCheck Page: 1 Page Index: 1 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf P2 max fixture wattage is 60 per previously submitted spec Subject: PlanCheck Page: 1 Page Index: 1 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf P3 max fixture wattage is 75 per previously submitted spec DD EX4 EX3 EXIT EX4 R3 8 Specifically demonstrate compliance with the provisions of 2015 IECC C405, including: -Revise lighting plans to show all lighting control requirements including: -Time switch controls -Light-reduction controls -Daylight-responsive controls -Exterior lighting controls Interior Lighting Compliance Certific 90.1 (2013) Standard Alteration e: OPKINS 1611 Owner/Agent:Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com mation MOUNTAIN FORGE TENANT FINISH rior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 CIAL UNIT (Common Space Types:Office - Enclosed)1585 1.11 CIAL UNIT (Common Space Types:Office - Enclosed)520 1.11 Fill out owner/agent Area Category Floor Area (ft2) Allowed Watts / ft2 Allowed Watts (B X C) 2-#4 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)1585 1.11 1759 3-#6 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)520 1.11 577 1-#1 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)1336 1.11 1483 4-#3 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)655 1.11 727 5-#7 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)485 1.11 538 6-#5 COMMERCIAL (Common Space Types:Office - Enclosed)133 1.11 148 7-#2 COMMERCIAL UNIT (Common Space Types:Office - Enclosed)340 1.11 377 5610Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures #4 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 1585 sq.ft.) LED 1: R3 & R4: DOWNLIGHT: Other:1 27 13 351 LED 2: P2: PENDENT AT BATHROOM: Other:1 4 13 52 LED 3: P3: PENDENT AT BATHROOM: Other:1 2 15 30 LED 4: T1: LED STRIP AT UTILITY: Other:1 1 32 32 LED 5: S2 & S3: SCONCE: Other:1 5 20 100 LED 6: TR1 &TR2: TRACK: Other:1 4 20 80 LED 7: C1: PENDANT AT POOL TABLE: Other:1 1 45 45 LED 5: S4: SCONCE: Other:1 1 20 20 #6 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 520 sq.ft.) LED 7: R3: DOWNLIGHT: Other:1 10 13 130 LED 8: S4: SCONCE: Other:1 10 20 200 LED 9: S4: LED STRIP AT UTILITY: Other:1 1 32 32 #1 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 1336 sq.ft.) LED 9: R3: DOWNLIGHT: Other:1 27 13 351 LED 20: UC4: UNDERCABINET: Other:1 2 10 20 Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation &Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/23/21Report date: 61 ofPage Track lights must be at least 30 W/linear ft., or the wattage limit of the system’s circuit breaker, or the wattage limit of other permanent current-limiting devices on the system. 2015 IECC C405.4.1 Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) NIT (Common Space Types:Office - Enclosed)1585 1.11 1759 NIT (Common Space Types:Office - Enclosed)520 1.11 577 NIT (Common Space Types:Office - Enclosed)1336 1.11 1483 NIT (Common Space Types:Office - Enclosed)655 1.11 727 NIT (Common Space Types:Office - Enclosed)485 1.11 538 Common Space Types:Office - Enclosed)133 1.11 148 NIT (Common Space Types:Office - Enclosed)340 1.11 377 5610Total Allowed Watts = r Lighting Power E (C X D) D Fixture Watt. A ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures UNIT ( Common Space Types:Office - Enclosed 1585 sq.ft.) OWNLIGHT: Other:1 27 13 351 NT AT BATHROOM: Other:1 4 13 52 NT AT BATHROOM: Other:1 2 15 30 RIP AT UTILITY: Other:1 1 32 32 CONCE: Other:1 5 20 100 TRACK: Other:1 4 20 80 NT AT POOL TABLE: Other:1 1 45 45 E: Other:1 1 20 20 UNIT ( Common Space Types:Office - Enclosed 520 sq.ft.) IGHT: Other:1 10 13 130 E: Other:1 10 20 200 RIP AT UTILITY: Other:1 1 32 32 UNIT ( Common Space Types:Office - Enclosed 1336 sq.ft.) IGHT: Other:1 27 13 351 P2 max fixture wattage is 60 per previously submitted spec 5610Total Allowed Watts = Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures RCIAL UNIT ( Common Space Types:Office - Enclosed 1585 sq.ft.) & R4: DOWNLIGHT: Other:1 27 13 351 PENDENT AT BATHROOM: Other:1 4 13 52 PENDENT AT BATHROOM: Other:1 2 15 30 LED STRIP AT UTILITY: Other:1 1 32 32 & S3: SCONCE: Other:1 5 20 100 1 &TR2: TRACK: Other:1 4 20 80 PENDANT AT POOL TABLE: Other:1 1 45 45 SCONCE: Other:1 1 20 20 RCIAL UNIT ( Common Space Types:Office - Enclosed 520 sq.ft.) DOWNLIGHT: Other:1 10 13 130 SCONCE: Other:1 10 20 200 LED STRIP AT UTILITY: Other:1 1 32 32 RCIAL UNIT ( Common Space Types:Office - Enclosed 1336 sq.ft.) DOWNLIGHT: Other:1 27 13 351 C4: UNDERCABINET: Other:1 2 10 20 : me: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/23/21Report date: 61 ofPage P3 max fixture wattage is 75 per previously submitted spec Response 04.08.2021 Lighting Control following the 2015 IECC have been noted on page E3.1 Response 04.08.2021 Owner and agent have been filled out and can be found on the lighting COMCheck file. Response 04.08.2021 Track lighting has been adjusted in the COMCheck file. See COMCheck file for update. Response 04.08.2021 P2 fixture has been adjusted to 6- watts per fixture in the lighting COMCheck file. Response 04.08.2021 P3 fixture has been adjusted to 75 watts per fixture in the lighting COMCheck file. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf Provide a cutsheet for fixture P11 showing maximum fixture wattage (comcheck must match) and listing. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf P4 max fixture wattage is 40 per previously submitted spec Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf UC4 fixture is 1.5 w/ft. per previously submitted cutsheet. Indicate length of fixture. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: Interior Lighting COMCheck Compliance Mountain Forge-20210323.pdf UC3 fixture is 1.5 w/ft. per previously submitted cutsheet. Indicate length of fixture. E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Track lighting 2: TR4: TRACK LIGHTING: Wattage based on 16 feet of track 0 0 480 480 LED 22: P10: PENDANT LIGHTING: Other:1 2 18 36 #3 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 655 sq.ft.) LED 11: R3: DOWNLIGHT: Other:1 13 13 169 LED 12: P11: PENDANTS: Other:1 2 16 32 #7 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 485 sq.ft.) LED 13: R3: DOWNLIGHT: Other:1 13 13 169 LED 14: P9: PENDANT: Other:1 4 20 80 LED 15: UC3: UNDERCABINET: Other:1 3 2 8 #5 COMMERCIAL ( Common Space Types:Office - Enclosed 133 sq.ft.) LED 18: T1: LED STRIP: Other:1 2 32 64 #2 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 340 sq.ft.) LED 21: R9: DOWNLIGHT: Other:1 4 8 30 LED 21: CV2: COVE LIGHTING: Other:1 9 2 14 Track lighting 1: TR3: TRACK LIGHTING: Wattage based on 14 feet of track 0 0 420 420 2944Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Provide a cutsheet for fixture P11 showing maximum fixture wattage (comcheck must match) and listing. E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Track lighting 2: TR4: TRACK LIGHTING: Wattage based on 16 feet of track 0 0 480 480 LED 22: P10: PENDANT LIGHTING: Other:1 2 18 36 #3 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 655 sq.ft.) LED 11: R3: DOWNLIGHT: Other:1 13 13 169 LED 12: P11: PENDANTS: Other:1 2 16 32 #7 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 485 sq.ft.) LED 13: R3: DOWNLIGHT: Other:1 13 13 169 LED 14: P9: PENDANT: Other:1 4 20 80 LED 15: UC3: UNDERCABINET: Other:1 3 2 8 #5 COMMERCIAL ( Common Space Types:Office - Enclosed 133 sq.ft.) LED 18: T1: LED STRIP: Other:1 2 32 64 #2 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 340 sq.ft.) LED 21: R9: DOWNLIGHT: Other:1 4 8 30 LED 21: CV2: COVE LIGHTING: Other:1 9 2 14 Track lighting 1: TR3: TRACK LIGHTING: Wattage based on 14 feet of track 0 0 420 420 2944Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES P4 max fixture wattage is 40 per previously submitted spec E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Track lighting 2: TR4: TRACK LIGHTING: Wattage based on 16 feet of track 0 0 480 480 LED 22: P10: PENDANT LIGHTING: Other:1 2 18 36 #3 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 655 sq.ft.) LED 11: R3: DOWNLIGHT: Other:1 13 13 169 LED 12: P11: PENDANTS: Other:1 2 16 32 #7 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 485 sq.ft.) LED 13: R3: DOWNLIGHT: Other:1 13 13 169 LED 14: P9: PENDANT: Other:1 4 20 80 LED 15: UC3: UNDERCABINET: Other:1 3 2 8 #5 COMMERCIAL ( Common Space Types:Office - Enclosed 133 sq.ft.) LED 18: T1: LED STRIP: Other:1 2 32 64 #2 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 340 sq.ft.) LED 21: R9: DOWNLIGHT: Other:1 4 8 30 LED 21: CV2: COVE LIGHTING: Other:1 9 2 14 Track lighting 1: TR3: TRACK LIGHTING: Wattage based on 14 feet of track 0 0 420 420 2944Total Proposed Watts = UC4 fixture is 1.5 w/ft. per previously submitted cutsheet. Indicate length of fixture. E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Track lighting 2: TR4: TRACK LIGHTING: Wattage based on 16 feet of track 0 0 480 480 LED 22: P10: PENDANT LIGHTING: Other:1 2 18 36 #3 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 655 sq.ft.) LED 11: R3: DOWNLIGHT: Other:1 13 13 169 LED 12: P11: PENDANTS: Other:1 2 16 32 #7 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 485 sq.ft.) LED 13: R3: DOWNLIGHT: Other:1 13 13 169 LED 14: P9: PENDANT: Other:1 4 20 80 LED 15: UC3: UNDERCABINET: Other:1 3 2 8 #5 COMMERCIAL ( Common Space Types:Office - Enclosed 133 sq.ft.) LED 18: T1: LED STRIP: Other:1 2 32 64 #2 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 340 sq.ft.) LED 21: R9: DOWNLIGHT: Other:1 4 8 30 LED 21: CV2: COVE LIGHTING: Other:1 9 2 14 Track lighting 1: TR3: TRACK LIGHTING: Wattage based on 14 feet of track 0 0 420 420 2944Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply withany applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation &Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 03/23/21Report date: 62 ofPage UC3 fixture is 1.5 w/ft. per previously submitted cutsheet. Indicate length of fixture. Response 04.08.2021 See provided fixture cutsheet showing maximum fixture wattage for fixture P11. Response 04.08.2021 P4 fixture has been adjusted to 75 watts per fixture in the lighting COMCheck file. Response 04.08.2021 The w/ft is indicated on the fixture on the COMCheck. LED 20: UC4: Undercabinet (1.5 W / LFT): Other. Under the column # of fixtures it indicates 9. This indicates that there is 9 Ft of this linear fixture. Under the column Fixture Watt, indicates 2 which means the fixture is calculated at 2 W / LFT to make sure the total is covered. Response 04.08.2021 The w/ft is indicated on the fixture on the COMCheck. LED 15: UC3: Undercabinet (1.5 W / LFT): Other. Under the column # of fixtures it indicates 5. This indicates that there is 5 Ft of this linear fixture. Under the column Fixture Watt, indicates 2 which means the fixture is calculated at 2 W / LFT to make sure the total is covered.