Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (55).ACBKtntertek H422 l.02-116-45 Page 11 of 19 Revised Report Date: 10/04/18 Total Quality. Assured. 84 85 86 87 88 89 90 91 ,-; "' � � <.I .... :a "O � E-< Ql =C. � � Q.; c., NFRC 100/200/500 Summary Sheet 350/600/900 Custom Pinnacle Sloped Glazed System M !"') """ � � "'"'Cl) "'"'Ql M Ql !"') Ql � C � ,:;t. ..c .c ,:;t. ,_ <.) .... -�-.� :a "O :9 � � .c � 6 E-< E-< � r... Ql Ql Ql <.) I =C. = C. C C. :: � c,i c,i c,; c,; c,; 0 Q.; c., Q.; C, Q.; c., ,..;:i -C � U-Eactor l,§War Heat ©ain Coeificient (Sf.IGC)Visible Transmittance (V'i(1 Gnds (l'lone z <;1 /,=I!) 9rids (None.t-<1 / >=1) 900 System: SB70 Bronze/ ARG90 / Clr-060'.PVB-Clr (6MM/DSLAMI) -1-l/16" IG 0.223 0.500 0.304 ARG90 0.018(#2) BZ -- IJ-F'._a,ctor 0-!Jl, SHG'Q(N,)0.20, i\fP (N) 0..35 900 System: SB60 I ARG90 I Clr-060PVB-ENADV (6MM/DSLAMI)-1-1/16'' IG 0.223 0.500 0.223 ARG90 0.035(#2) I 0.035(#4) CL U-Ractor 0.3_6'= �UGC(N) .Q:3� Yl'® .0.52 900 System: SB70 / ARG90 I Clr-060PVB-ENADV (6MM/DSLAMI)-1-1/16" IG 0.223 0.500 0.300 ARG90 0.018(#2) / 0.164(#4) CL -- l;!-Eactor 03Q g{J;C(N) Qa2ll VT(ffi Q.54 Ql t: I,. Ql <.) "O � ·�C. VJ c., ,,.Contlensation �sist.3nce TS-D N C::,R 6'2 TS-D N e:R so TS-D N €R so 900 System: SB60 / ARG90 / SB60 (#4) / ARG90 / Clr-060PVB-ENADV (6MM/5MM/DSLAMI)-1-1/2" IG 0.223 0.375 0.184 0375 0300 ARG90 o.035(#2) 1o.035(#4)10.164(#6) CL TS-D N U0'Fact9r p.z�SHG6i(N) 0.27 V:E(M 0.47 CR 68 900 System: SB60 I ARG90 I SB60 (#4) / ARG90 / Clr-060PVB-Clr (6MM/5MM/DSLAMI)-1-1/2" IG 0.223 --0.375 tfcF.�clQ_r 0.184 -l!� 0.375 0.304 1:;; SH6G(Nt ARG90. 0.035(#2) I 0.035(#4) CL TS-D N 0.21!, W(N) o,so ' €R 78 900 System: SB60 I ARG90 I SB60 (#4) I ARG90 I Clr-060PVB-Clr (6MM/5MM/DSLAMI)-1-3/4" IG 0.223 0.500 0.184 0.500 0.304 ARG90 0.035(#2) I 0.035(#4) CL TS-D N UsFactor o·-,-__ :, Sff<WOO 0,19 :v'I'(N) 0,50 :t1t_ n 900 System: SAGE GLASS GRAY (FULL TINT)/ AIR /LAMI060 (91V1M/5MM-060 PVB-511M)-l-5/16" IG 0.348 0.480 0.424 AIR 0.142(#2) GY SS-D N U-Fact!1r !).48 SHGC(M Q.lfZ . VT{N) Q .• 00 li@R S4 900 System: SAGE GLASS SR2.0 (FULL CLEAR)/ AIR / LAMI060 (7MM/5MM-060 PVB-SMM)-1 -1/16" IG 0.275 0.347 0.424 I I AIR 0.140(#2) CL SS-D N -- l!J-Factor Q.!li7 �H,G€�) 0.'38 VT (l'!) 0.53, eR ss 900 System: SAGE GLASS SR2.0 (FULL TINT)/ AIR / LAMI060 (7MM/5Mlvf-060 PVB-511M) - l -l /16" IG 0.275 0.347 0.424 I I AIR 0.140(#2) CL SS-D N I L - l:14.F!!gor Q.4i7 S.!IGC{l'!), Q.11 VT(N) 0.01 €R ss My "Translation" for #87: 1/4" Clear Tempered Solarban 60 #2 3/8" Argon fill 3/16" Clear Tempered Solarban 60 #4 3/8" Argon fill 5/16" Clear Heat strengthened Lami with .060 clear PVB interlayer 11/27/2019 This U factor (0.24) appears to be for the laminated glazing unit only. It does not appear to include the skylight frame. The U factor used in the Comcheck must be for the entire skylight assembly, including the frame. The following are acceptable methods under the 2015 IECC to verify fenestration U-factors as part of the building thermal envelope: 1.NFRC certification; label applied to window assembly and verified at field inspection. 2.Default values from 2015 IECC tables C303.1.3(1) C303.1.3(2), R303.1.3(1), and R303.1.3(2). 3.Default values from Table 4 U-Factors for Various Fenestration Products in 2013 ASHRAE Fundamentals Handbook chapter 15, pg. 15.3. To document the chain of custody, a certificate, affidavit or other evidence from the manufacturer confirming compliance with the above method is required. 4.Calculation methods in 2013 ASHRAE Fundamentals Handbook chapter 15, pg. 15.3: “U-Factor (Overall Coefficient of Heat Transfer)”. A calculation is required for the standard NFRC window size of 47.2” x 47.2”. To document the chain of custody, a certificate, affidavit or other evidence from the manufacturer confirming compliance with the above calculation is required. 5.U-ratings by an NFRC–accredited lab in accordance with NFRC-100. To document the chain of custody, verification labels affixed to the units by an accredited independent inspection agency or a certificate, affidavit or other evidence from the manufacturer confirming compliance with the above simulation or testing.