Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (71).ACBKBFP ERD-1 3" DCW ERD-1 ERD-1 101 102 3" AD-1 2" AD-1 302 302 BFP-2 MECHANICAL 005 ELECTRICAL 003 DATA CENTER 004 STORAGE 006 VESTIBULE 001 ELEVATOR 000 PUMP ROOM 008 RCP-1 1 1/2" DHW WH-1 1/2" DHWC SP-1 317 SP-3 203 2" V EE-1 w/ EE-MV-1 103 104 BFP-1 1 1/2" DHW 3/4" DHWC 1 1/4" V 204 900 2" SAN UP. 6" ERD-1 6" DCW 4" SAN UP TO G.C.O.ERD-1 ERD-1 ERD-1 4" SAN F.C.O. 200 4" S A N 4" F 3/4" DHWC 3" DCW 4" S A N 4" S A N 4" S AN 4" SAN 1 1 / 2 " P D NP 12 13 F G H IAA AA BB CC DD EE 1 2 P8 P7 4" SAN 2" V 2" S A N 4" S A N 4" S A N 2" V 511 511 2" AD-1 4" S T 3" S T 4" S T 30 GPM (955 SF) 21 GPM (652 SF) 14 GPM (442 SF) 4" ST UP TO G.C.O. 3/4" DCW WH-1 2" V 4" SAN 206 2" AD-1 20 GPM (620 SF) 3" S T 401 2" V 2" V GI-1 700 4" GW STORAGE 002 WS-1 WS-2 BT-1 3" D C W 701 2 1/2" NG UP. 4" GW UP.4" GW UP. TO G.C.O. 4" SAN UP.4" SAN UP. TO G.C.O. 1 1/2" 208 4" SAN 4" ST UP TO G.C.O. 4" ST UP TO G.C.O. 6" SAN 211 2" V 4" SAN 4" SAN 212 CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 3 5 P M P1.01 2016.01.0223 PLUMBING BASEMENT LEVEL PLAN AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O 1/8" = 1'-0"1 PLUMBING BASEMENT LEVEL PLAN FLAG NOTES (THIS SHEET) 101 PIPING IS NOT ALLOWED TO BE ROUTED OVER DATA CENTER. 102 PIPING IS NOT ALLOWED TO BE ROUTED OVER ELECTRICAL ROOM. 103 1-1/2" DOMESTIC COLD WATER TO DOMESTIC WATER FILL. REFER TO MECHANICAL PIPING SCHEMATIC ON SHEET M6.01. 104 CIRCUIT SOLVER BALANCING VALVE. TYPICAL 200 ROUTE 4" EXISTING SANITARY FROM EXISTING PARKING GARAGE RESTROOMS TO NEW SANITARY PIPING. 203 LOCATION OF NEW SAND OIL INTERCEPTOR. PROVIDE ZURN PROCEPTOR MODEL OMC OR COPELAND OF SIZE INDICATED ON DETAIL. 204 LOCATION OF SAN, REFER TO CIVIL FOR ELEVATIONS AND DETAILS. 206 ROUTE SANITARY FROM ERD-1 TO EXISTING SAND OIL INTERCEPTOR LOCATED IN GARAGE. 208 1-1/2" DRAIN FROM ELEVATOR 000. DISCHARGE INTO ERD-1. 211 LOCATE SP-1 CONTROL PANEL IN STORAGE ROOM 002. 212 LOCATE SP-2 CONTROL PANEL IN PUMP ROOM 008. 302 RUN STORM PIPE FROM ROOF DRAINS TO EXTERIOR OF BUILDING ON THE NORTH WEST SIDE. 317 DAYLIGHT STORM AND STORM OVERFLOW, REFER TO CIVIL PLANS FOR ELEVATION AND DETAILS. 401 CONNECT NEW 2-1/2" NG PIPING TO NG GENERATOR ON BASEMENT LEVEL. ROUTE PIPING IN TRASH 108 DOWN TO GENERATOR IN BASEMENT. 511 PIPING WITHIN THIS ROOM SHALL ONLY BE THE PIPE REQUIRED TO SERVE THE ROOM. 700 PROVIDE COPELAND GREASE INTERCEPTOR MODEL 11040 AT THIS LOCATION. REFER TO DETAIL ON SHEET P4.01 FOR MORE INFORMATION. 701 REFER TO DUPLEX WATER SOFTENER DETAIL ON P4.02 FOR DCW CONTINUATION. REFER TO P5.02 EQUIPMENT SCHEDULES FOR MORE INFORMATION. 900 PROVIDE DRAIN PAN BELOW ALL PIPING IN THIS ROOM. ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 Vents cannot be tied together until 12" above the top of the grease interceptor. Provide through penetration fires stop details for all plumbing penetrations of fire-resistance rated assemblies. A 11 11 C C D D D.5 D.5 E E 33 MSB-1 TRASH 108 MENS 102 A L-1 L-1 L-1 WC-1 UR-1 WC-2 FD-1 EWC-1 LOBBY 101 STAIR S001 VEST 107 WOMENS 103ELEC 106 JANITOR 105 TD 104 ELEVATOR 000 WC-1 L-1 WC-2 FD-1 B WH-1 3/4" DCW TD-1 6" ST 6" OST 6" ST 6" OST 317 316315 315 WH-1 104 2" SAN DN. WC-1 G.C.O. 205 2" SAN 901 12 12 13 13 F F G G H H I I AA AA BB BB CC CC DD DD EE EE 1 1 2 2 P8 P8 P7 P7 G.C.O. G.C.O. 207 G.C.O. G.C.O. 2 1/2" NG DN.402 G.C.O.G.C.O. GI-1 700 4" GW UP.4" GW DN. 205 CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 3 7 P M P1.02 2016.01.0223 PLUMBING MAIN LEVEL PLAN AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O 1/8" = 1'-0"1 PLUMBING MAIN LEVEL PLAN FLAG NOTES (THIS SHEET) 104 CIRCUIT SOLVER BALANCING VALVE. TYPICAL 205 REFERENCE DOUBLE CLEAN OUT DETAIL. 207 2" SANITARY SERVING EWC-1 ON FLOOR ABOVE. 315 6" STORM UP. 316 6" STORM OVERFLOW UP. 317 DAYLIGHT STORM AND STORM OVERFLOW, REFER TO CIVIL PLANS FOR ELEVATION AND DETAILS. 402 NEW NATURAL GAS METER WITH PRESSURE REGULATOR AT GRADE LEVEL BY OWNER. 14" W.C. OUTLET PRESSURE, 954 CFH CONNECTED LOAD, 100 FT TOTAL DEVELOPED LENGTH. 700 PROVIDE COPELAND GREASE INTERCEPTOR MODEL 11040 AT THIS LOCATION. REFER TO DETAIL ON SHEET P4.01 FOR MORE INFORMATION. 901 PIPING WITH THESE ROOMS SHALL ONLY BE THE PIPE REQUIRED TO SERVE THESE ROOMS. ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 DN A11 11 C C 3 MSB-1 A L-1 L-1 L-1 WC-1 WC-1 UR-1 WC-2 FD-1 EWC-1 STAIR S001 WOMENS 203 MENS 202 TD 204 JANITOR 205 ELEC 206 ELEVATOR 000 WC-2 L-1 B FD-1 2" ST 3" ST 3" ST EWC-1 2" S T 2" ST 2" ST 3 " S T 307306 308 4" S T 2" ST 2" ST 305 2" ST 2" S T 2" ST 3" ST 4" ST 4" ST 3" ST 3" ST 2" S T 4" S T 3/4" DCW 2" V 3/ 4 " D C W 2" V 104 WC-1 901 12 12 13 13 F F G G H H I I AA AA BB BB CC CC DD DD EE EE 1 1 2 2 P8 P8 P7 P7 4" GW UP & DN. ELEVATOR 000 209 CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 3 8 P M P1.03 2016.01.0223 PLUMBING MIDDLE LEVEL PLAN AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O 1/8" = 1'-0"1 PLUMBING MIDDLE LEVEL PLAN FLAG NOTES (THIS SHEET) 104 CIRCUIT SOLVER BALANCING VALVE. TYPICAL 209 PIT DRAIN TO BE ROUTED TO PUMP ROOM 008, DISCHARGING INTO ERD-1. REFER TO SHEET P1.01 FOR CONTINUATION. 305 2" STORM UP. TYPICAL. 306 6" STORM RISER. 307 6" STORM OVERFLOW RISER. 308 4" STORM UP.TYPICAL. 901 PIPING WITH THESE ROOMS SHALL ONLY BE THE PIPE REQUIRED TO SERVE THESE ROOMS. ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 Where do the storm drains discharge? RD RD RD RD RD RD RD RD RD RD RD RD A 11 11 C C D D 33 MSB-1 6" ST 6" OST MEETING ROOM 309 A WC-1 UR-1 WC-2 FD-1 EWC-1 28 GPM (877 SF) 6 GPM (193 SF) 2" 26 GPM (839 SF) 3" 26 GPM (839 SF) 3" WC-1 WC-2 FD-1 L-1 L-1L-1 L-1 B 28 GPM (877 SF) 28 GPM (877 SF) 28 GPM (877 SF) 6 GPM (193 SF) 2" 8.5 GPM (241 SF) WH-1 1" DCW 303 304 303 304 303 3043" DD-1 3" DD-1 3" OST 3" ST 4" PD-1 3" PD-1 2" DD-1 2" DD-1 3" OST 2" S T WH-1 3/4" DCW 3.5 GPM (105 SF) 8.5 GPM (265 SF) 47 GPM (1511 SF) 2" DD-1 4" PD-1 3" PD-1 47 GPM (1511 SF) 76 GPM (2412 SF) 76 GPM (2412SF) 309 309 309 309 4" ST3" ST 20 GPM (614 SF) 2" ST 3" ST 3" OST 4" S T 4" O S T 305 3" OST 4" DSN-1 2" DSN-1 3" PD-1 311 313 3/4" DCW MENS 302WOMENS 303 LOBBY 301 VEST 307 OFFICE 308 MEETING ROOM 310 TD 304 ELEVATOR 000 JANITOR 305 104 WC-1 1-1/2" DCW & 1" DHW VALVE AND CAP FOR FUTURE 901 1" DCW UP TO ROOF HYDRANT 12 12 13 13 F F G G H H I IAA AA BB BB CC CC DD DD EE EE 1 1 2 2 P8 P8 P7 P7 3" DD-1 3" DD-1 4" GW DN 3" V UP W.C.O. 210 CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 4 0 P M P1.04 2016.01.0223 PLUMBING UPPER LEVEL PLAN AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O 1/8" = 1'-0"1 PLUMBING UPPER LEVEL PLAN FLAG NOTES (THIS SHEET) 104 CIRCUIT SOLVER BALANCING VALVE. TYPICAL 210 4" GREASE WASTE STUB-OUT WITH CLEAN OUT. 303 3" STORM UP. TYPICAL. 304 3" STORM OVERFLOW UP. TYPICAL. 305 2" STORM UP. TYPICAL. 309 POINT OF CONNECTION FOR ARCHITECTURAL SLOT DRAIN. REFER TO P1.03 FOR CONNECTION SIZE. 311 2" STORM UP IN WALL FOR CONNECTION TO RD-2. REFER TO SHEET P1.05. 313 4" STORM UP IN WALL FOR CONNECTION TO RD-2. REFER TO SHEET P1.05. 901 PIPING WITH THESE ROOMS SHALL ONLY BE THE PIPE REQUIRED TO SERVE THESE ROOMS. ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 A 11 11 52 GPM (1650 SF) 52 GPM (1650 SF) 46 GPM (1460 SF) 46 GPM (1460 SF) RH-1 300 3" RD-1 3" RD-1 3" RD-1 3" ORD-1 3" ORD-1 3" ORD-1 202 2" RD-2 2" RD-2 2" RD-2 4" RD-2 310 310 312 510 12 12 13 13 F F G GAA AA BB BB CC CC DD DD EE EE 1 1 2 2 P8 P8 P7 P7 300 300 300 3" RD-1 3" ORD-1 3"VTR CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 4 1 P M P1.05 2016.01.0223 PLUMBING ROOF PLAN AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O 1/8" = 1'-0"1 PLUMBING ROOF PLAN FLAG NOTES (THIS SHEET) 202 4" VENT THROUGH ROOF. 300 PROVIDE HEAT TRACE AROUND DRAIN AND INTO GUTTER AND DOWNSPOUT, TYPICAL. 310 2" STORM DOWN IN WALL FOR CONNECTION TO DSN-1. REFER TO SHEET P1.04. 312 4" STORM DOWN IN WALL FOR CONNECTION TO DSN-1. REFER TO SHEET P1.04. 510 3" FIRE RISER FOR CONNECTION TO ROOF MANIFOLD. PIPING MUST BE ROUTED IN 2 HOUR RATE ENCLOSURE TO MANIFOLD. ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 Inaccessible for maintenance. PS PS FS S DUPLEX SEWAGE EJECTOR DETAIL - FIBERGLASS NO SCALE NOTES: 1. THE SUMP PUMP MANUFACTURER SHALL PROVIDE: PUMPS, BASIN(S), COVERS, LIFTING CABLES, DISCONNECT SYSTEM, INLET/OUTLET SEALS, PUMP CONTROLS, PUMP CONTROL WIRING, PUMP POWER WIRING AND ALL ADDITIONAL APPURTENANCES REQUIRED FOR COMPLETE AND FUNCTIONAL SYSTEM. 2. SEAL INLET/OUTLET PENETRATIONS ALONG WITH ALL JOINTS WITH A MANUFACTURER APPROVED METHOD. 3. INSTALL SUMP ENCLOSURE ON 4" MINIMUM OF 95% COMPACTED BEDDING MATERIAL OVER UNDISTURBED NATIVE SOIL. SEWAGE EJECTOR DUPLEX ALARM/CONTROL PANEL POWER BY DIVISION 26 CONTRACTOR CONTROL MONITORING BY DIVISION 23 CONTRACTOR FLOAT SWITCHES, (TYPICAL). PROVIDE OFF, 1 PUMP ON, 2 PUMPS ON AND HIGH LEVEL SWITCHES. SET FLOATS AT LEVELS RECOMMENDED BY THE MANUFACTURER. SE-#, DUPLEX SEWAGE EJECTORS SEE SPECIFICATIONS. PROVIDE POWER FEEDS OF LENGTH ACCEPTABLE TO CODE. ONE PUMP SHOWN FOR CLARITY. PUMP GUIDE RAIL AND DISCONNECT SYSTEM FOR EASE OF REMOVAL AND SERVICING; PROVIDED BY PUMP MANUFACTURER. (TYPICAL) UPPER GUIDE RAIL BRACKET (TYPICAL) PUMP DISCHARGE REFER TO PLANS FOR CONTINUATION GATE VALVE (TYPICAL) CHECK VALVE (TYPICAL) ELECTRICAL CONDUIT, COORDINATE SIZE AND ROUTING INSTALLATION REQUIREMENTS WITH DIVISION 26 CONTRACTOR PUMP LIFTING CABLE (TYPICAL) FLOAT CONTROL JUNCTION BOX (NEMA 6) 3" SUMP VENT 6" SANITARY SEWER 36" DIA. FIBERGLASS SUMP BASIN WITH SEALED ACCESS LID. 12'0" DEPTH. 7' - 0 " AUTOMATIC ELECTRIC ELEVATOR SUMP PUMP DETAIL NO SCALE COMBINATION WATER ENTRY PIPING DETAIL NO SCALE 6" BY PLUMBING CONTRACTOR BY FIRE PROTECTION CONTRACTOR SEE COMBINED WATER AND FIRE ENTRY DETAIL 3" 3" 2-1/2" 1-1/2" 3" 4" 4" TO PREACTION SPRINKLER SYSTEM DATA CENTER SINGLE INTERLOCK PREACTION SYSTEM DRAIN RISER ADJACENT TO STANDPIPE RISER ROOF MANIFOLD AT PLAZA LEVEL TO MANUAL WET STANDPIPE RISER 3" WATER &/OR FIRE ENTRY; IRON NO SCALE L W 6" TOTAL WATER CAP. APPROX. DIMENSIONS (INCHES) 330 800 1190 1600 W L A B C D E 48" 72" 48" 24" 22" 24" 10" 48" 96" 64" 32" 40" 42" 23" 72" 96" 64" 32" 40" 42" 23" 72" 144" 96" 48" 40" 42" 23" 6" 5' MIN. FROM BLDG. ALL SIDES 4" CD=C+2" CHAMBER SECONDARY CHAMBER PIPE O.D. +2" CAST IRON TRAFFIC LIDS REQUIRED IN AREAS SUBJECT TO VEHICLE ROLLOVER. CLEANOUT, TYP. COMBO OR WYE AND 1/8 BEND. VENT THRU ROOF OR COMBINE WITH COMMON VENT SYSTEM. SUPPORT BRACKETS REQUIRED ON ALL CAST IRON PIPING INSTALLATIONS 36" ON CENTER.A TO SEWER GRADE TOP OF VAULT BELOW FINISHED GRADE OR AT GRADE IF BELOW GRADE, RING AND COVER SHALL BE ADJUSTED TO FINAL GRADE USING A MINIMUM OF 4" GRADE RING(S) AND A MAXIMUM OF 36" GRADE RING(S). A CONE IS REQUIRED FOR GREATER. LOCATION (TYP.) 2" VENT IN TOP OF SLAB. PRIMARY B WATER LEVEL BAFFLE WALL 24" STD. COVER. NON-SHRINK GROUT AROUND ALL PIPE OPENINGS (TYP). PRECAST REINF. CONC. TOP SLAB (REMOVABLE) LIFTING RINGS AT 4 CORNERS. CAPACITY CHART PLAN SECTION GREASE INTERCEPTOR DETAIL NO SCALE SAN TEE 9" 90° BEND 12" 12"1.5"-2" 12" MIN. E C 6" CONC. FILLET ALL AROUND STEEL REINFORCEMENT IN TOP AND BOTTOM SLABS AND WALL TO BE SPECIFIED BY ARCH/ENG FOR H-20 LOADS. 14" MIN. 8" MIN. AS REQUIRED (12" MIN) 1840 72" 46" 48" 28" 2080 72" 52" 54" 32" 2560 72" 64" 68" 41" 3040 72" 76" 78" 50" 3280 72" 82" 84" 55" 3520 72" 88" 90" 59" GREASE CAP. APPROX. (GALLONS) (CU. FT.) 13 41 61 84 103 117 150 183 202 216 144" 144" 144" 144" 144" 144" 96" 96" 96" 96" 96" 96" 48" 48" 48" 48" 48" 48" I.E. = __________I.E. = __________ L W 6"RATED CAPACITY DIMENSIONS (INCHES) 300 750 1000 1500 W L A B C D E 48" 72" 48" 24" 21" 14" 7" 48" 96" 64" 32" 38" 25" 13" 72" 108" 72" 36" 30" 20" 10" 72" 120" 80" 40" 40" 27" 13" 6" 5' MIN. FROM BLDG. ALL SIDES E 4"CD F G CHAMBER SECONDARY CHAMBER PIPE O.D. +2" CAST IRON TRAFFIC LIDS REQUIRED IN AREAS SUBJECT TO VEHICLE ROLLOVER. CLEANOUT, TYP. COMBO OR WYE AND 1/8 BEND. VENT THRU ROOF INDEPENDENTLY. SUPPORT BRACKETS REQUIRED ON ALL CAST IRON PIPING INSTALLATIONS 36" ON CENTER. A TO SEWER GRADE NOTE: F=C+2" NOTE: G=D-2" TOP OF VAULT BELOW FINISHED GRADE OR AT GRADE IF BELOW GRADE, RING AND COVER SHALL BE ADJUSTED TO FINAL GRADE USING A MINIMUM OF 4" GRADE RING(S) AND A MAXIMUM OF 36" GRADE RING(S). A CONE IS REQUIRED FOR GREATER. LOCATION (TYP.) 2" VENT IN TOP OF SLAB. PRIMARY 90 DEGREE ELL B NON-SHRINK GROUT REQUIRED. WATER LEVEL BAFFLE WALL 24" STD. COVER. NON-SHRINK GROUT AROUND ALL PIPE OPENINGS (TYP). PRECAST REINF. CONC. TOP SLAB (REMOVABLE) LIFTING RINGS AT 4 CORNERS. CAPACITY CHART PLAN SECTION SAND & OIL INTERCEPTOR DOUBLE COMPARTMENT DETAIL NO SCALE I.E. = __________I.E. = __________ ELECTRIC WATER HEATER PIPE RELIEF VALVE TO FLOOR DRAIN. HOT WATER TO SYSTEM. COLD WATER SUPPLY. HOT WATER CIRC. FROM FIXTURES. THERMAL EXP. ABSORBER PRESSURE GAUGE RECIRC. PUMP. SUPPORT FROM FLOOR. GRATE ELEVATOR PIT FLOOR PUMP ALARM SENSOR ALARM PANEL NOTE: INSTALL PUMP AND ACCESSORIES PER MANUFACTURES INSTRUCTIONS FINISH FLOOR ESP-1 (50 GPM PER ELEV CAR MIN) GRADE SERVICE CEMENT LINED DUCTILE IRON SERVICE.BASEMENT FLOOR. C.I. HUB TO FLANGED ADAPTER. TIE RODS; TYP. SEAL W/ 2 PART POLYSULFIDE CAULKING. WALL SLEEVE; I.D. = 4" LARGER THAN O.D. OF PIPE WITH WATER SEAL. THRUST BLOCK AT 1 ELL. PROVIDE OFFSET IN PIPE WITH 3 ELLS FOR PIPE MOVEMENT. SEE DETAIL. BASEMENT WALL. NOTES: 1. VERIFY SERVICE PIPE MATERIAL TYPE WITH LOCAL WATER UTILITY 2. SERVICE PIPE ELEVATION SHALL BE SET TO ENSURE NO LESS THAN 6' OF COVER OR THE COVER DEPTH REQUIRED BY THE AHJ; THE DEEPER DEPTH SHALL APPLY. IT IS ACCEPTABLE FOR PIPE DEPTH TO BE LOWER THAN THIS REQUIREMENT. DRAIN VALVE PIPE TO FLOOR DRAIN TYP. STANDPIPE SYSTEM MAIN MIN. 4" DOMESTIC WATER HEATER DETAIL NO SCALE (ELECTRIC) EXTERIOR HORN WALL 5'-0" MAX. 1'-6" MIN. LIGHT AND WATER GRADE FLANGE SERVICE 4'-0" MIN. 1/2" F BALL DRIP AUTOMATIC PIPE TO FLOOR DRAIN VALVE, PREVENTER BACKFLOW FLOOR DRAIN, TYP. PRESSURE GA. (TYP) INSTALL FUNNEL AND DRAIN BELOW PURGE DRAIN OF BFP-1 ROUTE COMBINED DRAIN TO ERD. PROVIDE FS999 DOWN STREAM OF COMBINED DRAIN. 1" NP TO MECHANICAL FILL SEE PLANS FOR CONTINUATION FIRE DEPT. CONNECTION FOR MANUAL WET STANDPIPE AND SPRINKLER SYSTEM. SEE PLANS FOR LOCATION. METER 1-1/2" NP TO SITE IRRIGATION SEE PLANS FOR CONTINUATION NON-UTILITY BAS SYSTEM METER ON PLANS FOR CONTINUATION SEE DOMESTIC WATER LINE 3" TO ASPEN CITY OFFICES UTILITY METER, INSTALL PER PRV, CLA-VAL 90-01 OR EQUIVALENT, TYP ASPEN WATER DEPARTMENT METER BYPASS WITH LOCKING VALVE AND PARALLEL BFP PER WATER DEPT, TYP NP METER & BFP CAN BE LOCATED IN MECHANICAL ROOM, TYP PIPE TO DRAIN VALVE, FLOOR DRAIN, TYP. CAFAC-1 AIR COMPRESSOR CONDENSATE DRAIN PREACTION VALVE ASSEMBLY LOCATION PIPE TO OUTSIDE. TEST VALVE AT MOST REMOTE SEE FIRE SPRINKLER FLOOR CONTROL VALVE ASSEMBLY DETAIL MAIN, MIDDLE, AND UPPER FLOORS SPRINKLER ZONE VALVES OFF OF MANUAL WET STANDPIPE. LOCATION PIPE TO OUTSIDE. TEST VALVE AT MOST REMOTE BASEMENT ZONE (WET PIPE AREA) 1" NP TO FUTURE EVAP SECTION ON AHU-1 WATTS FLOOD PROTECTION SHUT DOWN CONTROL VALVE, MODEL LFF113RFP. PROVIDE FS999 FLOW SENSOR AND JB113 CONTROL BOX AS REQUIRED. CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 4 1 P M P4.01 2016.01.0223 PLUMBING DETAILS AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 2 1 "2 5 6 1 2 3 4 9 8 7 FS 12" MIN NOTE: ALL THREADED JOINT MAKE UP SHALL BE ACCOMPLISHED WITH APPROVED JOINT COMPOUND FOR NATURAL AND MFGRD GAS. MAKE UP WITH NO LESS THAN 2 THREADS SHOWING. TEST FOR LEAKS AS REQ'D BT SPECIFICATIONS. DIRT LEG APPLIANCE CONNECTION MALLEABLE UNION MALLEABLE TEE, STD OR REDUCING AS REQ'D CLOSE NIPPLE 3/4 & 1" SIZE: USE GROUND JOINT GAS COCK, OVER 1" USE LUBRICATED PLUG COCK OR RATED & APPROVED BALL VALVE PRIMARY GAS SUPPLY TO APPLIANCE SEE DRAWING FOR SIZE 6" MIN FULL SUPPLY PIPE SIZE MALLEABLE CAP ALL NIPS TBE (TYP) ROUGH GRADE 8" 3" FINISHED GRADE IN LANDSCAPE LANDSCAPE BOX - MARKED C.O. LAWNLAWN PROVIDE HEAVY DUTY CAST-IRON COVER UNLESS ALTERNATE COVER APPROVED BY AHJ AND OWNER HEAVY DUTY CAST-IRON STREET GRADE COVER (DRIVE AREA) PAVEMENT SUB-GRADE CLEAN-OUT PLUG PVC/ABS BODY ALL CLEAN-OUT ADAPTERS ARE TO BE GLUED IN PLACE NICKEL BRONZE ADJUSTABLE HEAD ASSEMBLY. ADJUSTABLE FLOOR CLEAN-OUT FOR FOOT TRAFFIC FINISHED GRADE ROUGH FLOOR SLAB EXTERIOR INTERIOR RE: PLBG DWGS FOR SIZES FILL ANNULAR SPACE WITH NON HARDENING, ADHESIVE TYPE WATER & GAS TIGHT SEALANT FOUNDATION WALL WALL SLEEVE 4" LARGER I.D. THAN O.D. OF SEWER PIPE WITH WATER PROOF FLANGE CAST-IN PLACE TO SEWER RE: PLBG DWGS FOR SIZES D.I. OR C.I. HUB & SPIGOT PIPE "SV" WEIGHT 4" MIN. RE: PLBG DWG SIZES 6" MIN. NOTE: WALL SLEEVE REQUIRED WHERE FOUNDATION WALL IS PENETRATED. SEE PLANS. 18" DIA. POURED CONCRETE RING. SLOPE AWAY FROM CLEAN-OUT PLUG TOP OF MULCH OR ROCK WALL CLEANOUT DETAIL NO SCALE PRESSURE REGULATOR 10" MIN CAPPED TEE CAPPED TEE PRESSURE REGULATOR ISOLATION VALVE LOCATE TEES TO PROVIDE ACCESS FOR INSTALLATION OF MEASURING DEVICES GPR VENT ROUTED TO BUILDING EXTERIOR AND PROVIDE WITH MANUFACTURER'S APPROVED VENT CAP. VENT PIPING SHALL NOT BE SMALLER THAN THE VENT CONNECTION AND MULTIPLE GPR VENTS ARE NOT ALLOWED TO BE COMBINED. GAS PRESSURE REGULATOR DETAIL NO SCALE FLAG NOTES THIS DETAIL: DOUBLE CLEANOUT DETAIL NO SCALE FLOOR CLEANOUT DETAIL NO SCALE DUPLEX WATER SOFTENER DETAIL NO SCALE GAS CONNECTION DETAIL NO SCALE SANITARY OR STORM BLDG. DRAIN THRU WALL NO SCALE SCHEMATIC DETAIL FOR FIRE SPRINKLER FLOOR CONTROL VALVE ASSEMBLY MAY EXTEND AS A WASTE OR VENT. WALL PLUGGED TEE WITH CLEANOUT. CHROME WALL COVER AND SCREW FLOOR LINE BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 1' - 0 " 1/8 BEND 6" FLOOR LINE CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/TOP OF FLOOR. 16" SQ. CONC. PAD TROWEL SMOOTH & EDGE BRASS CLEANOUT PLUG W/COUNTER SUNK HEAD FINISHED GRADE 1/8 C.I. BEND C.I. WASTE LINE. LENGTH TO SUIT. 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE WASTE LINE CLEANOUT TO GRADE (COTG) BALANCE OF PIPING SAME AS CLEANOUT TO GRADE 1/8 C.I. BEND DRAINS TO ERD. EXTEND AND AIR-GAP SOFTENER BACKWASH, SOFTENER & BRINE CONTROL VALVE DRAIN LINE BRINE LINE BACKWASH LINE TO 4" MIN SIZE FLOOR DRAIN WATER SOFTENER JACK LEGS TYP: OF 3 STEP LEG LEVELERS MANUAL BYPASS BALL VALVE NORMALLY CLOSED UNION EMERGENCY SOFT WATER OUT DO NOT OPEN EXCEPT IN BALL VALVE REGENERATION CONTROL VALVE TAG: NORMALLY CLOSED DRAIN LINE MANHOLE INSERTION WATER SOFTENER BACKWASH LINE JACK LEGS DRAIN VALVE CONTROL VALVE 4"ERD BRINE TANK FLOW SENSOR BALL VALVE UNION CONTROL VALVE REGENERATION CONTROL VALVE HARD WATER IN ALL PIPING AND FITTINGS SHOWN HATCHED ARE NOT FURNISHED WITH SOFTENER NOTE: FLOW SENSORFLOOR CLEANOUT (FCO) CLEANOUT NOT TO BE LOCATED IN CARPETED AREA GRADE BASEMENT FLOOR. BASEMENT WALL. WALL SLEEVE; I.D. = 4" LARGER THAN O.D. OF PIPE. STORM OR SANITARY BLDG. DRAIN. CAULK W/ 2 PART POLYSULFIDE CAULKING. NO SCALE TO WET PIPE SPRINKLER SYSTEM WET PIPE SPRINKLER SYSTEM RISER DRAIN RISER, 3" MINIMUM 1. INDICATING SHUT-OFF VALVE PER NFPA 13. 2. CHECK VALVE. 3. PRESSURE GAUGE, TYP. 4. PRESSURE REDUCING VALVE,* SET TO LIMIT THE STATIC/RESIDUAL PRESSURE TO 165 PSI. 5. PRESSURE RELIEF VALVE.* 6. FLOW SWITCH TO FIRE ALARM SYSTEM. 7. COMBINATION TEST AND DRAIN VALVE WITH RESTRICTION ORIFICE, EQUAL TO THE SMALLEST FLOW FROM A SPRINKLER HEAD. 8. SIGHT GLASS. 9. A RISER MANIFOLD ASSEMBLY CONTAINING COMPONENTS INDICATED BY NOTES 3, 6, 7 AND 8, AS AN ALTERNATE TO USING COMPONENTS INDICATED BY NOTES 3, 6, 7 AND 8 SEPARATELY. THE PRESSURE REDUCING VALVE AND ASSOCIATED PRESSURE RELIEF VALVE MAY BE OMITTED FOR UPPER FLOORS IF STATIC PRESSURE (PUMP CHURN PRESSURE AND THE PUBLIC SUPPLY PRESSURE) AT THAT FLOOR IS LESS THAN 175 PSI. *NOTE: CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 4 1 P M P4.02 2016.01.0223 PLUMBING DETAILS AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O ISSUE: DATE: 03/16/2019 P-Fixture_Master_Schedule/PLUMBING FIXTURE AND EQUIPMENT SCHEDULE PLAN FIXTURE ICC/ANSI A117.1 MANUFACTURER SERIES TRIM SERIES SUPPLIES TRAP / DRAIN CW HW / WASTE VENT WATER NOTES / REMARKS CODE COMPLIANT #WASTE TEPID CONSUMPTION BFP-1 REDUCED PRESSURE ---FEBCO 860 / LF880V --- --- INTEGRAL --- --- SEE --- --- --- --- W/MANUFACTURER'S MATCHING PRIN. BACKFLOW PREVENTOR 2-1/2" - 10"PLANS AIR GAP DRAIN BFP-2 REDUCED PRESSURE ---FEBCO 860 / LF880V --- --- INTEGRAL --- --- SEE --- --- --- --- W/MANUFACTURER'S MATCHING PRIN. BACKFLOW PREVENTOR 2-1/2" - 10"PLANS AIR GAP DRAIN DD-1 DECK DRAIN ---J.R. SMITH 1470-C --- --- --- --- --- --- --- SEE --- --- PLANS DSN-1 DOWNSPOUT ---J.R. SMITH 1770 --- --- --- --- --- --- --- SEE --- --- MOUNT 24" ABOVE FIN. GRADE NOZZLE JOSAM 25010 PLANS EE-MV-1 EYE WASH ---GUARDIAN G3600LF --- --- W/ISO. --- --- 3/4" 3/4" --- --- --- 2, ANSI Z358.1-2004 COMPLIANT MIXING VALVE VALVE EE-1 EMERGENCY EYE WASH, BARRIER FREE YES - ANSI A117.1 GUARDIAN GBF1750 --- --- W/ISO. --- --- --- 1/2" --- --- 3.5 GPM COMPLIANT VALVE 2,10 ERD-1 EQUIPMENT ---J.R. SMITH 2410 --- --- --- P-TRAP INTEGRAL --- --- 4" 2" ---- 9, HINGED GRATE ROOM DRAIN JOSAM 35130 MEDIUM DUTY, W/SEDIMENT BUCKET EWC-1 ELECTRIC WATER COOLER YES - ANSI A117.1 ELKAY VRCTLR8WSK --- --- W/STOP P-TRAP INTEGRAL 3/4" --- 2" 1-1/2" --- 11, ELECT: 120/1v, 5 FLA, PLUG-IN BI-LEVEL, WM W BOTTLE FILLER COMPLIANT FCO FLOOR CLEANOUT ---J.R. SMITH 4020/4040 --- --- --- --- --- --- --- SEE --- --- JOSAM 55000-1/-1SQ PLANS FD-1 FLOOR DRAIN ---J.R. SMITH 2010-A/B --- --- --- P-TRAP INTEGRAL --- --- 2" 1-1/2" --- JOSAM 9 L-1 LAVATORY YES - ANSI A117.1 AMERICAN 0491.019 SLOAN EAF 250 W/STOPS OFFSET GRID 1/2" 1/2" 1 1/2" 1 1/2" 0.5 GPM 7, 10 CHINA, CT COMPLIANT STANDARD RONDALYN P-TRAP 4" CENTER SET MSB-1 MOP SERVICE BASIN ---FIAT TSB - 700 AMERICAN 8344.012 INTEGRAL P-TRAP 1453-BB 1/2" 1/2" 3" 2" 3.0 GPM 1 TERRAZO 36"x24"x12" STANDARD ORD-1 OVERFLOW ---J.R. SMITH 1070 --- --- --- --- --- --- --- SEE --- --- PROVIDE W/WATER DAM ROOF DRAIN JOSAM 21500-16 PLANS ORD-2 OVERFLOW ---J.R. SMITH 1560 --- --- --- --- --- --- --- SEE --- --- OVERFLOW TO BE INSTALLED 2" ABOVE ROOF DRAIN PLANS PRIMARY DRAIN RD-1 ROOF DRAIN ---J.R. SMITH 1010 --- --- --- --- --- --- --- SEE --- --- JOSAM 21500 PLANS RH-1 ROOF HYDRANT ---WOODFORD RHY2-MS --- --- --- --- --- 1" --- SEE --- --- PLANS PD-1 PLANTER DRAIN ---J.R. SMITH 1930 --- --- --- --- --- --- --- SEE --- --- PLANS PD-2 PLANTER/ PLAZA DRAIN ---J.R. SMITH 1920 --- --- --- --- --- --- --- SEE --- --- PLANS PRV-1 WATER PRESSURE REDUCING ---CLA-VAL 90-01 --- --- W/ISO. --- --- SEE --- --- --- --- 2, W/STRAINER, PRESSURE "WATER CONTROL" VALVE VALVE PLANS GUAGE & RELIEF VALVE SA-1 SHOCK ABSORBER ---JOSAM 75000 --- --- --- --- --- SEE SEE --- --- --- 2 (WTR-HAMMER ARRESTERS)PLANS PLANS TD-1 TRENCH DRAIN ---MEA-JOSAM J1000 --- --- --- P-TRAP INTEGRAL --- --- SEE SEE ---9, PROVIDE SEDIMENT (CHANNEL DRAINAGE)PLANS PLANS INTERCEPTOR WHERE NOTED TP-1 TRAP PRIMER ---WATTS A200 --- --- --- --- --- 1/2" --- --- ---2 UR-1 URINAL YES - ANSI A117.1 SLOAN --- SLOAN WEUS-1000 --- --- INTEGRAL 3/4" --- 2" 1-1/2"0.13 GAL 7 WM, INTEGRAL SHIELDS COMPLIANT ECOS 140#-.013 PER FLUSH WC-1 WATER CLOSET --- SLOAN --- SLOAN WETS 2452.1101 --- --- --- 1" --- 4" 2" 1.1 GAL W/OPEN FRONT NO LID SEAT WM, FV PER FLUSH 7, MOUNTING HEIGHT PER ARCH WC-2 WATER CLOSET YES - ANSI A117.1 SLOAN --- SLOAN WETS 2751.1101 --- --- --- 1" --- 4" 2" 1.1 GAL W/OPEN FRONT NO LID SEAT WM, FV COMPLIANT PER FLUSH 7, MOUNTING HEIGHT PER ARCH WH-1 WALL HYDRANT ---WOODFORD B65 --- --- W/ISO. --- --- 3/4" --- --- --- --- 2, MOUNT 18" ABOVE FIN. GRADE FROST PROOF VALVE WM-1 WATER METER ---MUELLER SERIES IIS --- --- W/ISO. --- --- SEE --- --- --- --- W /ELECTRONIC READING SYSTEM DISPLACEMENT VALVE PLANS FOR CONTROL CONNECTION WMV-1 THERMAL MIXING ---WATTS LFUSG-B --- --- --- -- --- 3/8" 3/8" --- --- --- INSTALL DOWNSTREAM OF VALVE, FIXTURE FIXTURE STOPS WMV-2 THERMAL MIXING ---LEONARD VALVE TM-420B-LF --- --- W/ISO. -- --- SEE SEE --- --- --- 2, PROVIDE WITH INLET STOPS VALVE, FIXTURE(S)HIGH-LOW VALVE PLANS PLANS AND STRAINERS LEGEND:CH = CHILD HEIGHT, CM = CEILING MOUNTED, CP = CHROME PLATED, CT = COUNTERTOP, FM = FLOOR MOUNTED, FV = FLUSH VALVE, PA = PRESSURE ASSIST, SS = STAINLESS STEEL, TP = PROVIDE TRAP PRIMER (TP-1) ADJACENT TO FIXTURE, WM = WALL MOUNTED (PROVIDE WITH A FLOOR MOUNTED CONCEALED CARRIER), UCT = UNDER COUNTERTOP GENERAL NOTES: 1.WHERE FIXTURE/EQUIPMENT MODEL NUMBERS ARE GIVEN THESE ARE FOR REFERENCE ONLY. WRITTEN # WHERE NOTED THE PLUMBING FIXTURE, EQUIPMENT AND ASSOCIATED ACCESSORIES SPECIFICATION REQUIREMENTS AND SCHEDULE NOTES HOLD PRESIDENCE. THE MORE STRIGENT SHALL APPLY SHALL BE ICC/ANSI A117.1 (ADA) COMPLIANT. EXPOSED CW, HW AND W PIPING ALONG WITH 2.SEE ARCHITECTURAL DWGS FOR MOUNTING HEIGHTS ON ALL WALL MOUNTED FIXTURES/EQUIPMENT,MIXING VALVE SHALL INSULATED. PIPING WITHIN CASEWORK THAT OPENS FOR FIXTURE ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER ANY VALUES WITHIN THIS SCHEDULE.USE IS CONSIDERED EXPOSED. 3.THE MINIMUM WASTE/VENT PIPE SIZE FOR BURIED PIPE SHALL BE 2". 4.ALL ACCESIBLE FIXTURES SHALL COMPLY WITH ICC/ANSI A117.1 (ADA), REFERENCE ARCH DWGS FOR SPECIFIC LOCATIONS. SEE NOTE # 5.ALL FIXTURES AND EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. SPECIFIC NOTES: 1.PROVIDE WITH STAINLESS STEEL RIM GUARDS, STAINLESS STEEL WALL PANELS, MOP BRACKET, HOSE, DOME STRAINER AND DRAIN CONNECTOR. 2.EQUIPMENT AND/OR ISOLATION VALVE SHALL BE CONCEALED (WITHIN ADJACENT WALL OR WITHIN CASEWORK). WHERE LOCATED IN WALL/CEILING COORDINATE FINAL DEVICE AND ACCESS DOOR LOCATION WITH ARCHITECT. 3.PRESSURE BALANCE &/OR THERMOSTATIC MIXING VALVE WITH INTEGRAL STOPS, WALL SHOWER, AND DRAIN. ANSI A112.18.1 OR ASSE 1016 RATED. 4.PRESSURE BALANCE &/OR THERMOSTATIC MIXING VALVE WITH INTEGRAL STOPS, DIVERTER VALVE, WALL SHOWER, WALL/HAND SHOWER THAT HAS NONPOSITIVE SHUT-OFF, 60" FLEXIBLE METAL HOSE, 36" SLIDE BAR AND DRAIN. ANSI A112.18.1 OR ASSE 1016 RATED. 5.SHOWER BASE (UNLESS NOTED), BENCH, GRAB BARS, WALL SURROUND, DOOR/CURTAIN AS REQUIRED BY ARCHITECT. PROVIDE DRAIN FOR SHOWER BASE OR TILE INSTALLATION COORDINATE WITH SELECTED BASE MANUFACTURER. 6. LOCATE SHOWER DISCHARGE ABOVE AN ADJACENT 2" FLOOR DRAIN. 7.PROVICE WITH AUTOMATIC-TYPE ELECTRONIC SENSOR TRIM, BATTERY POWERED. 8.PROVIDE WITH AUTOMATIC-TYPE ELECTRONIC SENSOR TRIM, 115/1v POWERED AND PROVIDE WITH BATTERY BACKUP (OR NON-POWER MANUAL OVERRIDE) 9.PROVIDE 1/2" TRAP PRIMER CONNECTION. PROVIDE TRAP PRIMER (TP-1) AND PIPING BETWEEN PRIMER AND DRAIN. CONNECT TRAP PRIMER TO DOMESTIC COLD WATER MAIN IN ACCORDANCE WITH MANUFACTER'S INSTRUCTION. PRIMER CAN BE OMITTED WHERE DRAIN IS PROVIDED WITH AN ASSE 1072 CERTIFIED TYPE TRAP SEAL THAT HAS BEEN APPROVED BY THE AUTHORITY HAVING JURISDICTION. 10.PROVIDE WITH ASSE 1070 RATED THERMAL MIXING VALVE (WMV-1) LOCATED DOWNSTREM OF FIXTURE STOPS UNLESS SERVED FROM AN ASSE 1070 RATED GROUP-FIXTURE THERMAL MIXING VALVE. 11. COOLING CAPACITY: 7.5 GPH COOLED TO 50ºF AT AN AMBIENT AIR TEMPERATURE OF 90ºF AND ENTERING WATER TEMPERATURE OF 80ºF. 12.PROVIDE SHOCK ARRESTOR(S) ON HW, CW AND TEPID SUPPLIES. 13.PROVIDE AN ASSE 1022 BEVERAGE DISPENSING BACKFLOW PREVENTOR (BFP-3) FOR EACH BEVERAGE DISPENING OUTLET BOX. CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 4 1 P M P5.01 2016.01.0223 PLUMBING SCHEDULES AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 DOMESTIC WATER HEATER SCHEDULE ITEM SERVICE TANK CAP. [GAL] HEATING CAPACITY ELECTRICAL DATA OPERATING WEIGHT [LBS] MANUFACTURER & MODEL NO. NOTES CONTROLS ELEC OUTPUT [kW] RECOVERY [GPH] TEMP RISE [°F]FLA V-PH WH-1 Buidling 105 24 99 100 76 208-3 185 RHEEM -ECLIPSE ME 105 1, 2 INTEGRAL GENERAL NOTES (APPLY TO ALL PRODUCT): 1) CONTROLS: INTEGRAL = INTERNAL CONTROLS PROVIDED WITH UNIT, DDC = DIRECT DIGITAL CONTROLS BY 23 0900, OTHER = SEE NOTES 3) INSTALL WATER HEATER AND PIPING PER SELECTED MANUFACTURES WRITTTEN INSTRUCTIONS SPECIFIC NOTES (APPLY WHERE NOTED): 1) ALL ELEMENTS RUN SIMULTANEOUSLY. kW AND AMPERAGE LISTED ARE FOR ALL ELEMENTS BEING ON. 2) PROVIDE SINGLE POINT ELECTRICAL POWER CONNECTION WITH FACTORY INSTALLED FUSED DISCONNECT FOR HEATING ELEMENTS AND CONTROLS. PUMP SCHEDULE ITEM TYPE SERVICE GPM TOTAL MOTOR DATA OP MANUFACTURER NOTES CON- HEAD HP BHP RPM V-PH STRTR WGT & MODEL NO.TROLS FT. W.C.LBS RCP-1 INLINE DOM H.W. 7.5 16.0 1/25 3250 115 8 TACO 008-F6 DDC NOTES: SALT BRINE TANK ITEM TYPE SERVICE PIPE TANK RESIN EXCHANGE CAPACITY FLOW PRESSURE MANUFACTURER NOTES SIZE SIZE @ SALT DOSAGE DROP & MODEL NO. IN IN FT^3/L MAX kgr/lb MIN kgr/lb GPM PSI BT-1 SIDE MOUNT DOM. WATER 3 30 10.0 300 200 86 15 CULLIGAN CSM 300-3 1 NOTES:1. REFER TO MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION VENDOR: CULLIGAN COMMERICAL: MIKE DEGROOT Mdegroot@hallswater.com, 303-419-6757 SEWAGE AND SUMP PUMP SCHEDULE ITEM TYPE SERVICE NO. GPM HEAD MOTOR SUMP MANUFACTURER & MODEL # CONTROLS NOTESHP RPM V-PH STRTR DIA. DEPTH INCHES INCHES SP-1 SEWAGE ELEVATOR SUMP 1 55.0 25 0.5 3450 115-1 CONTROLLER - - MYERS ME50S-11 EPC SERIES CONTROL PANEL 1, 2 SP-2 SEWAGE ELEVATOR SUMP 1 55.0 25 0.5 3450 115-1 CONTROLLER - - MYERS ME50S-11 EPC SERIES CONTROL PANEL 1, 2 SP-3 SEWAGE BUILDING SEWAGE 2 55.0 30 0.5 3450 208-3 CONTROLLER - - MYERS MWH50-23 DUPLEX PANEL CONTROL PANEL CE-23DW 1, 2 NOTES:SP-1 & 2 UTILIZE CONCRETE SUMP IN ELEVATOR PIT. PIT COVER PROVIDED BY ARCHITECTURAL DIVISION 1. REFER TO DETAIL FOR ALL DIMENSIONS. 2. PROVIDE PUMP GUIDE RAIL AND DISCONNECT SYSTEM PROVIDE HIGH WATER ALARM ZOELLER MODEL:10-0126 WATER SOFTENER TANKS ITEM TYPE SERVICE PIPE TANK RESIN EXCHANGE CAPACITY FLOW PRESSURE MANUFACTURER NOTES SIZE SIZE @ SALT DOSAGE DROP & MODEL NO. IN IN FT^3 MAX kgr/lb MIN kgr/lb GPM PSI WS-1 SIDE MOUNT DOM. WATER 3 30x60 20.0 300 200 169 15 CULLIGAN CSM-300-3 1, 2 WS-2 SIDE MOUNT DOM. WATER 3 30x60 20.0 300 200 169 15 CULLIGAN CSM-300-3 1, 2 NOTES:1. REFER TO MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION 2. PROVIDE 120V OUTLET . VENDOR: CULLIGAN COMMERICAL: MIKE DEGROOT Mdegroot@hallswater.com, 303-419-6757 PLUMBING INSULATION SCHEDULE SYSTEM INSULATION TYPE FLUID TEMPERATURE RANGE PIPE SIZES SPECIFIC NOTES <1"1" to 1-1/4" 1-1/2" to 3" 4" to 6" 8" and Larger DOMESTIC COLD WATER FLEXIBLE ELASTOMERIC OR GLASS FIBER PREFORMED PIPE INSULATION --- 1/2" 1/2" 1" 1" 1"1 DOMESTIC HOT WATER AND DOMESTIC HOT WATER RECIRC GLASS FIBER OR MINERAL FIBER PREFORMED PIPE INSULATION 141 TO 200 DEG F 1-1/2" 1-1/2" 2" 2" 2" < 140 DEG F 1" 1" 1-1/2" 1-1/2" 1-1/2" STORM AND OVERFLOW FLEXIBLE ELASTOMERIC OR GLASS FIBER PREFORMED PIPE INSULATION --- 1/2" 1/2" 1" 1" 1"1 CONDENSATE AND EQUIPMENT DRAIN WATER FLEXIBLE ELASTOMERIC OR GLASS FIBER PREFORMED PIPE INSULATION < 60 DEG F 1/2" 1" 1" 1" 1" GENERAL NOTES: 1) FOR PIPING EXPOSED TO THE OUTSIDE AMBIENT CONDITIONS OR PIPING PROVIDED WITH HEAT TRACE, INCREASE THICKNESS OF INSULATION BY 1/2". 2) FOR PIPING EXPOSED TO THE OUTSIDE AMBIENT CONDITIONS PROVIDE PROTECTIVE JACKET (SEE SPECIFICATIONS). 3) ALL INSULATION EXPOSED TO UV CONDITIONS SHALL BE PROTECTED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS. SPECIFIC NOTES: 1) PROVIDE PIPE INSULATION WICKING SYSTEM ON ALL EXISTING SYTEMS THAT ARE OPERATIONAL DURING INSULATION. CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 4 2 P M P5.02 2016.01.0223 PLUMBING SCHEDULES AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019 MSB-1 MSB-1 MSB-1 EWC-1 EWC-1 EWC-1 L-1 WC-2 FD-1 FD-1 4" WCO FD-1 WC-1 UR-1 4" VTR 2" V 44.5 DFU'S 44.5 DFU'S 44.5 DFU'S WC-2 WC-1 WC-1 2" SAN FROM EWC-1 ON MIDDLE LEVEL SEE P1.01 FOR CONTINATUION SEE P1.01 FOR CONTINATUIONSEE P1.01 FOR CONTINATUION L-1 L-1 L-1 2" V TO TD-1 L-1 WC-2 FD-1 FD-1 4" WCO WC-1 UR-1 WC-2 WC-1 WC-1 L-1 L-1 L-1 L-1 WC-2 FD-1 4" WCO WC-1 UR-1 WC-2 WC-1 WC-1 L-1 L-1 L-1 2" V FROM EWC-1 ON MIDDLE LEVEL UPPER FLOOR MIDDLE LEVEL MAIN LEVEL BASEMENT LEVEL 4" V 4" V 4 " S A N 4 " S A N 4 " S A N 4 " S A N 4 " S A N 4 " S A N 4" V 2" V 4" SAN 4" V 4" V 2" V 1 1/2" V 1 1/2" V 3" SA N 3" SA N 3" SA N 4" SAN 2" V2" V 2" V 3" SAN 3" SAN 3" SAN 134 DFU'S MSB-1 MSB-1 MSB-1 EWC-1 EWC-1 EWC-1 L-1 L-1 56 WSFU'S WC-2 WC-1 UR-1 L-1 L-1WC-1 WC-2 WC-1 1-1/2" DCW 1" DHW FOR FUTURE 3/4" DHW 1/2" DCW 1/2" DHW 1/2" DHWC 3/4" DCW 1" DCW 1 1/2" DCW 1" DHW 2" DCW 2" DCW 1 1/2" DCW SA-1 60 WSFU TO ROOF AND WALL HYDRANT 3/4" DHW 1" DHW1/2" DHW 2" DCW 1 1/2" DHW 2 1/2" DCW 1 1/2" DHW 3" DCW 1 1/2" DHW 1 1/2" DHW 3/4" DHWC 3" DCW 56 WSFU'S 56 WSFU'S L-1 L-1 WC-2 WC-1 UR-1 L-1 L-1 WC-1 WC-2 WC-1 L-1 L-1 WC-2 WC-1 UR-1 L-1 L-1 WC-1 WC-2 WC-1 3/4" DCW TO EWC-1 3/4" DCW TO WH-1 1 1/2" DCW 2" DCW 1/2" DHW 1" DHW 3/4" DHW 2" DCW 3/4" DCW 1" DCW 3/4" DHW 1/2" DHWC 2" DCW 1 1/2" DCW 1/2" DHW 1" DHW 3/4" DHW 1/2" DHWC 3/4" DHW 1" DCW CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC SHEET NO. JOB NO. 2/ 6 / 2 0 1 8 4 : 4 5 : 4 4 P M P6.01 2016.01.0223 ISOMETRICS AS P E N C I T Y O F F I C E S 42 5 R I O G R A N D E P L A C E AS P E N , C O 1 Isometric A 2 Isometric B ISSUE: DATE: 50% DD 10/30/17 100% DD 12/12/17 PERMIT 02/07/18 03/16/2019