HomeMy WebLinkAboutFile Documents.210 W Main St.0056.2019 (92).ARBKWELS Markup #1 210 W Main Page: [1] 2019-0009 B-IR-1 (Irrigation Plan) Author: rickma Date: 3/29/2019 1:39:24 PM File Name: DR 09.IRRIGATION - 2019-0014 Submittal Set-20190305.pdf As per WELS Section 5.2.7, trees should be on separate valves from turf grass, where feasible. [1] 2019-0009 B-IR-1 (Irrigation Plan) (3) Page: [1] 2019-0009 B-IR-1 (Irrigation Plan) Author: rickma Date: 3/19/2019 3:27:55 PM File Name: DR 09.IRRIGATION - 2019-0014 Submittal Set-20190305.pdf As per WELS Section 5.2.3, areas less than 10 feet in any direction shall not utilize overhead sprinklers. Revise plan accordingly. Page: [1] 2019-0009 B-IR-1 (Irrigation Plan) Author: rickma Date: 3/21/2019 10:35:06 AM File Name: DR 09.IRRIGATION - 2019-0014 Submittal Set-20190305.pdf There is a proposed Cottonwood in this general location on Sheet L4.03. Please revise this plan to irrigate tree on separate zone from turf. 4 0.59 1" 4 5 1.93 1"5 6 0.73 1"6 7 1.63 1" 7 1" 1"1" 1" 114" VALVE SCHEDULE As per WELS Section 5.2.7, trees should be on separate valves from turf grass, where feasible. 310.6 1" 3 4 0.59 1" 4 5 1.93 1"5 6 0.73 1"6 7 1.637 1" 1"1" 1" SYMBOL MANUFACTURER/MODEL Rain Bird XCZ-100-PRB-LC Wide Flow Drip Control Kit Pressure Regulating 40psi Pipe Transition Point in Dri Pipe transition point from P box. Area to Receive Dripline Rain Bird XFS-06-12 XFS Sub-Surface Pressure 0.6 GPH emitters at 12" O. for triangular pattern. UV R Area to Receive Dripline Rain Bird XFS-06-18 XFS Sub-Surface Pressure 0.6 GPH emitters at 18" O. for triangular pattern. UV R SYMBOL MANUFACTURER/MODEL Rain Bird DVF - 1" Standard configuration, ele With Flow Control. Rain Bird 33-DRC - 3/4" 3/4" Brass Quick-Coupling Spring, Thermoplastic Rub Lockable Shut Off Valve Rain Bird 100-PEB Master 1" Plastic Industrial Valves. Configuration. Febco 825YA - 1" Reduced Pressure Backflo Hunter PRO HC-1200 Wi-Fi enabled, full-function controller, 120 VAC, Outdo Hunter HC-100-FLOW 1" Flow meter for use with and provide system alerts. on any residential or comm C FS As per WELS Section 5.2.3, areas less than 10 feet in any direction shall not utilize overhead sprinklers. Revise plan accordingly. 6 0.73 1"6 7 1.63 1" 7 1" There is a proposed Cottonwood in this general location on Sheet L4.03. Please revise this plan to irrigate tree on separate zone from turf. Page: 1 Author: rickma Date: 3/21/2019 10:35:38 AM File Name: DR 08. LANDSCAPE PLAN - King Louise 013119.pdf There is a proposed Cottonwood in this general location on Sheet L4.03. Please include on this plan. 1 (7) Page: 1 Author: rickma Date: 3/19/2019 3:52:06 PM File Name: DR 08. LANDSCAPE PLAN - King Louise 013119.pdf Please include the irrigation valve numbers for each hydrozone. For example: Hydrozone B (A1, A5, etc.) Page: 1 Author: rickma Date: 3/19/2019 4:34:00 PM File Name: DR 08. LANDSCAPE PLAN - King Louise 013119.pdf The Maximum Applied Water Budget is 7.5/gal/sq.ft./season. If "Special Features" are being utilized to increase the allowable water budget, those features need to be identified and accounted for. See WELS Section 4.3.1 (b) for information. Page: 1 Author: rickma Date: 3/19/2019 3:30:26 PM File Name: DR 08. LANDSCAPE PLAN - King Louise 013119.pdf Designer's signature will be required prior to approval There is a proposed Cottonwood in this general location on Sheet L4.03. Please include on this plan. oil d Please include the irrigation valve numbers for each hydrozone. For example: Hydrozone B (A1, A5, etc.) Property Line Parking / Pervious Pavement Edge of Green Roof Above Proposed Hardscape Proposed Small Shrub Proposed Medium Shrub Proposed Lawn in Right o Existing Sid Proposed Street Tree Per Parks Depa Proper Proposed Lilac S Proposed W The Maximum Applied Water Budget is 7.5/gal/sq.ft./season. If "Special Features" are being utilized to increase the allowable water budget, those features need to be identified and accounted for. See WELS Section 4.3.1 (b) for information. PROPERTY LINE aping e Designer's signature will be required prior to approval Page: 1 Author: rickma Date: 3/19/2019 4:11:03 PM File Name: DR 08. LANDSCAPE PLAN - King Louise 013119.pdf Is this seed mix being utilized for this project? If so, identify the location of seeded areas Page: 1 Author: rickma Date: 3/19/2019 4:25:11 PM File Name: DR 08. LANDSCAPE PLAN - King Louise 013119.pdf Please revise legend or add notations to clearly indicate the locations of these zones on the plan Page: 1 Author: rickma Date: 3/19/2019 4:20:09 PM File Name: DR 08. LANDSCAPE PLAN - King Louise 013119.pdf Please provide more information on the "green roof", including but not limited to: exact locations, planting plan/list, hydrozone designation, provisions for irrigation, etc. Native Grass MIx Common Name Scientific Name % of Mix CrestedWheat, Ephraim Agropyron cristatum 30 Sheep Fescue Festuca ovina 20 Perennial Ryegrass Lolium perenne 25 Canada Blue, Talon Poa compressa 15 Chewings Fescue Festuca rubra commutata 10 Revegetate disturbed areas by hand seeding with a certified weed free straw. A Plantago-based tackifier, or similar approved product, should be applied on all straw at the rate of 150 lbs per acre to prevent wind from blowing straw off the revegetated areas. Seed Mix Is this seed mix being utilized for this project? If so, identify the location of seeded areas 6. Quality Of Plant Material Is To Be Approved By The Contractor Before Installation. 7. All Planted Areas To Be Covered With Mini Pine Bark Nuggets Only (No Debris Mixed In). Mulch To Be A Minimum Depth Of 4". Mulch To Be Applied To Soil Surface Only, Not Against Stems Or Tree Trunk Base. 8. Planting Beds Are To Contain "Pre-mixed" Planting Mixture To A Minimum Depth Of 12" 9. All Planting Beds Are To Be Contained By 4" Metal Edging. 10. Irrigate All Disturbed Areas With An Automatic Irrigation System. 11. Layout All Planting Beds And Edge Prior To Plant Installation. 12. All Plerennials Are To Be Layed Out With Uniform Spacing. Layout To Be Approved By Contractor Prior To Installation. 13. Contractor To Provide & Install Drainage And Irrigation/ Lighting Sleeves As Needed For All Planting Areas. “I have complied with the criteria of the Water Efficient Landscaping Standards and applied them for the efficient use of water in the landscape design plan”. Ben Morgan RLA Water Usagage Legend HZ 'C' - VeryHigh/Sod - Drip HZ 'B' - Medium/Flower Beds - Drip HZ 'A' - Low/Flower Beds - Drip Hydrozones Right of Way - Spray Please revise legend or add notations to clearly indicate the locations of these zones on the plan Property Line Parking / Pervious Pavement Edge of Green Roof Above Proposed Hardscape Proposed Small Shrub Proposed Medium Shrub Proposed Lawn Proposed L Proposed Street Tree P P Propo Please provide more information on the "green roof", including but not limited to: exact locations, planting plan/list, hydrozone designation, provisions for irrigation, etc.