HomeMy WebLinkAboutFile Documents.210 W Main St.0056.2019 (92).ARBKWELS Markup #1 210 W Main
Page: [1] 2019-0009 B-IR-1 (Irrigation Plan)
Author: rickma
Date: 3/29/2019 1:39:24 PM
File Name: DR 09.IRRIGATION - 2019-0014 Submittal
Set-20190305.pdf
As per WELS Section 5.2.7, trees should be on separate valves from turf grass, where feasible.
[1] 2019-0009 B-IR-1 (Irrigation Plan) (3)
Page: [1] 2019-0009 B-IR-1 (Irrigation Plan)
Author: rickma
Date: 3/19/2019 3:27:55 PM
File Name: DR 09.IRRIGATION - 2019-0014 Submittal
Set-20190305.pdf
As per WELS Section 5.2.3, areas less than 10 feet in any direction shall not utilize overhead sprinklers. Revise plan accordingly.
Page: [1] 2019-0009 B-IR-1 (Irrigation Plan)
Author: rickma
Date: 3/21/2019 10:35:06 AM
File Name: DR 09.IRRIGATION - 2019-0014 Submittal
Set-20190305.pdf
There is a proposed Cottonwood in this general location on Sheet L4.03. Please revise this plan to irrigate tree on separate zone
from turf.
4 0.59
1"
4 5 1.93
1"5
6 0.73
1"6
7 1.63
1"
7
1"
1"1"
1"
114"
VALVE SCHEDULE
As per WELS Section
5.2.7, trees should be
on separate valves from
turf grass, where
feasible.
310.6
1"
3
4 0.59
1"
4 5 1.93
1"5
6 0.73
1"6
7 1.637
1"
1"1"
1"
SYMBOL MANUFACTURER/MODEL
Rain Bird XCZ-100-PRB-LC
Wide Flow Drip Control Kit
Pressure Regulating 40psi
Pipe Transition Point in Dri
Pipe transition point from P
box.
Area to Receive Dripline
Rain Bird XFS-06-12
XFS Sub-Surface Pressure
0.6 GPH emitters at 12" O.
for triangular pattern. UV R
Area to Receive Dripline
Rain Bird XFS-06-18
XFS Sub-Surface Pressure
0.6 GPH emitters at 18" O.
for triangular pattern. UV R
SYMBOL MANUFACTURER/MODEL
Rain Bird DVF - 1"
Standard configuration, ele
With Flow Control.
Rain Bird 33-DRC - 3/4"
3/4" Brass Quick-Coupling
Spring, Thermoplastic Rub
Lockable Shut Off Valve
Rain Bird 100-PEB Master
1" Plastic Industrial Valves.
Configuration.
Febco 825YA - 1"
Reduced Pressure Backflo
Hunter PRO HC-1200
Wi-Fi enabled, full-function
controller, 120 VAC, Outdo
Hunter HC-100-FLOW
1" Flow meter for use with
and provide system alerts.
on any residential or comm
C
FS
As per WELS Section 5.2.3,
areas less than 10 feet in any
direction shall not utilize
overhead sprinklers. Revise
plan accordingly.
6 0.73
1"6
7 1.63
1"
7
1"
There is a proposed Cottonwood in
this general location on Sheet
L4.03. Please revise this plan to
irrigate tree on separate zone from
turf.
Page: 1
Author: rickma
Date: 3/21/2019 10:35:38 AM
File Name: DR 08. LANDSCAPE PLAN - King Louise
013119.pdf
There is a proposed Cottonwood in this general location on Sheet L4.03. Please include on this plan.
1 (7)
Page: 1
Author: rickma
Date: 3/19/2019 3:52:06 PM
File Name: DR 08. LANDSCAPE PLAN - King Louise
013119.pdf
Please include the irrigation valve numbers for each hydrozone. For example: Hydrozone B (A1, A5, etc.)
Page: 1
Author: rickma
Date: 3/19/2019 4:34:00 PM
File Name: DR 08. LANDSCAPE PLAN - King Louise
013119.pdf
The Maximum Applied Water Budget is 7.5/gal/sq.ft./season. If "Special Features" are being utilized to increase the allowable water
budget, those features need to be identified and accounted for. See WELS Section 4.3.1 (b) for information.
Page: 1
Author: rickma
Date: 3/19/2019 3:30:26 PM
File Name: DR 08. LANDSCAPE PLAN - King Louise
013119.pdf
Designer's signature will be required prior to approval
There is a proposed Cottonwood
in this general location on Sheet
L4.03. Please include on this
plan.
oil
d
Please include the irrigation valve
numbers for each hydrozone. For
example: Hydrozone B (A1, A5, etc.)
Property Line
Parking / Pervious Pavement
Edge of Green Roof Above
Proposed Hardscape
Proposed Small Shrub
Proposed Medium Shrub
Proposed Lawn in Right o
Existing Sid
Proposed Street Tree Per Parks Depa
Proper
Proposed Lilac S
Proposed W
The Maximum Applied Water
Budget is 7.5/gal/sq.ft./season. If
"Special Features" are being
utilized to increase the allowable
water budget, those features need
to be identified and accounted for.
See WELS Section 4.3.1 (b) for
information.
PROPERTY LINE
aping
e Designer's signature
will be required prior
to approval
Page: 1
Author: rickma
Date: 3/19/2019 4:11:03 PM
File Name: DR 08. LANDSCAPE PLAN - King Louise
013119.pdf
Is this seed mix being utilized for this project? If so, identify the location of seeded areas
Page: 1
Author: rickma
Date: 3/19/2019 4:25:11 PM
File Name: DR 08. LANDSCAPE PLAN - King Louise
013119.pdf
Please revise legend or add notations to clearly indicate the locations of these zones on the plan
Page: 1
Author: rickma
Date: 3/19/2019 4:20:09 PM
File Name: DR 08. LANDSCAPE PLAN - King Louise
013119.pdf
Please provide more information on the "green roof", including but not limited to: exact locations, planting plan/list, hydrozone
designation, provisions for irrigation, etc.
Native Grass MIx
Common Name Scientific Name % of Mix
CrestedWheat, Ephraim Agropyron cristatum 30 Sheep Fescue Festuca ovina 20
Perennial Ryegrass Lolium perenne 25
Canada Blue, Talon Poa compressa 15
Chewings Fescue Festuca rubra commutata 10
Revegetate disturbed areas by hand seeding with a certified weed free straw.
A Plantago-based tackifier, or similar approved product,
should be applied on all straw at the rate of 150 lbs per
acre to prevent wind from blowing straw off the
revegetated areas.
Seed Mix
Is this seed mix being
utilized for this project?
If so, identify the
location of seeded
areas
6. Quality Of Plant Material Is To Be Approved By The Contractor Before Installation.
7. All Planted Areas To Be Covered With Mini Pine Bark Nuggets Only (No Debris Mixed In). Mulch To Be A
Minimum Depth Of 4". Mulch To Be Applied To Soil Surface Only, Not Against Stems Or Tree Trunk Base.
8. Planting Beds Are To Contain "Pre-mixed" Planting Mixture To A Minimum Depth Of 12"
9. All Planting Beds Are To Be Contained By 4" Metal Edging.
10. Irrigate All Disturbed Areas With An Automatic Irrigation System.
11. Layout All Planting Beds And Edge Prior To Plant Installation.
12. All Plerennials Are To Be Layed Out With Uniform Spacing. Layout To Be Approved By Contractor Prior To
Installation.
13. Contractor To Provide & Install Drainage And Irrigation/ Lighting Sleeves As Needed For All Planting Areas.
“I have complied with the criteria of the Water Efficient Landscaping
Standards and applied them for the efficient use of water in the
landscape design plan”.
Ben Morgan RLA
Water Usagage Legend
HZ 'C' - VeryHigh/Sod - Drip
HZ 'B' - Medium/Flower Beds - Drip
HZ 'A' - Low/Flower Beds - Drip
Hydrozones
Right of Way - Spray
Please revise legend
or add notations to
clearly indicate the
locations of these
zones on the plan
Property Line
Parking / Pervious Pavement
Edge of Green Roof Above
Proposed Hardscape
Proposed Small Shrub
Proposed Medium Shrub
Proposed Lawn
Proposed L
Proposed Street Tree P
P
Propo Please provide more information
on the "green roof", including but
not limited to: exact locations,
planting plan/list, hydrozone
designation, provisions for
irrigation, etc.