Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (76).ACBKWELS Markup #1 425 Rio Grande Page: IR-0 - IRRIGATION LEGEND & NOTES Author: rickma Date: 3/28/2019 2:22:34 PM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf Areas of irrigated public ROW can be excluded from the water budget calculations IR-0 - IRRIGATION LEGEND & NOTES (5) Page: IR-0 - IRRIGATION LEGEND & NOTES Author: rickma Date: 3/26/2019 10:59:11 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf Update all WELS numbering to most recent Section numbering Page: IR-0 - IRRIGATION LEGEND & NOTES Author: rickma Date: 3/26/2019 4:40:48 PM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf A1 is shown to be serving CST overhead on Sheet IR-4. Please revise accordingly. Page: IR-0 - IRRIGATION LEGEND & NOTES Author: rickma Date: 3/26/2019 10:39:32 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf The Maximum Applied Water Budget is 7.5 gal/sq.ft./season, unless "Special Features" are utilized. (See Section 4.3.1 for more information) Please revise all plans accordingly. Areas of irrigated public ROW can be excluded from the water budget calculations Update all WELS numbering to most recent Section numbering A1 is shown to be serving CST overhead on Sheet IR-4. Please revise accordingly. The Maximum Applied Water Budget is 7.5 gal/sq.ft./season, unless "Special Features" are utilized. (See Section 4.3.1 for more information) Please revise all plans accordingly. Page: IR-0 - IRRIGATION LEGEND & NOTES Author: rickma Date: 3/26/2019 10:58:40 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf The trees proposed (Aspen and Cottonwood) are medium water use plants, not high. Revise plans and calculations accordingly. Page: IR-1 - IRRIGATION PLAN Author: rickma Date: 3/27/2019 9:27:23 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf Soil moisture sensors are required for all irrigated green roofs as per WELS Section 5.1.7 IR-1 - IRRIGATION PLAN (4) Page: IR-1 - IRRIGATION PLAN Author: rickma Date: 3/29/2019 10:44:09 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf As per Section 5.1.6, Sensors (e.g., rain, freeze,wind/or soil moisture, etc.) that suspend or alter irrigation operation during unfavorable weather conditions or when sufficient moisture is present shall be required on all irrigation systems. Please identify the sensors employed, and their location on the plans. Page: IR-1 - IRRIGATION PLAN Author: rickma Date: 3/29/2019 10:48:43 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf Trees (24) should be on separate valves from turf grass areas where feasible, as per Section 5.2.7 The trees proposed (Aspen and Cottonwood) are medium water use plants, not high. Revise plans and calculations accordingly. 411" 1" A2 24.4 Turf 1" A3 6.19 Turf 1" A4 21.6 Turf 30 55 55 3.0 3.0 3.0 Soil moisture sensors are required for all irrigated green roofs as per WELS Section 5.1.7 As per Section 5.1.6, Sensors (e.g., rain, freeze,wind/or soil moisture, etc.) that suspend or alter irrigation operation during unfavorable weather conditions or when sufficient moisture is present shall be required on all irrigation systems. Please identify the sensors employed, and their location on the plans. CONTROLLER 120 VAC POWER REQUIRED 411"411" 4" 411" 1" A2 24.4 Turf 1" A3 6.19 Turf 1" A4 21.6 Turf 1" A57.25 Inline 6 3 30 30 55 55 3.03.0 3.0 3.0 3.0 3.0 3.0 1.5 2 3.0 3.0 3.0 3.03.0 6.0 6.0 MA IRRI Trees (24) should be on separate valves from turf grass areas where feasible, as per Section 5.2.7 Page: IR-1 - IRRIGATION PLAN Author: rickma Date: 4/1/2019 3:34:41 PM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf As per WELS Section 5.1.4, dedicated water meters/sub-meters shall be installed for all non-residential irrigated landscapes of 5,000 sq.ft. or more. Page: IR-3 - IRRIGATION PLAN Author: rickma Date: 3/27/2019 9:36:22 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf As per WELS Section 5.2.3, narrow areas less than 10 feet in dimension, including turf grass areas, shall not use overhead sprinkler irrigation. Revise plans accordingly. IR-3 - IRRIGATION PLAN (3) Page: IR-3 - IRRIGATION PLAN Author: rickma Date: 4/1/2019 3:28:58 PM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf What are the zone design pressures for all the valves on this system? Page: IR-3 - IRRIGATION PLAN Author: rickma Date: 4/1/2019 8:14:36 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf All trees (8) should be on separate valves from turf grass areas where feasible, as per Section 5.2.7 POC SIZE: 2-INCH PRESSURE: 75 PSI FLOW: 50 GPM A 1 4 As per WELS Section 5.1.4, dedicated water meters/sub-meters shall be installed for all non-residential irrigated landscapes of 5,000 sq.ft. or more. 411" 411" 1" A22 23.5 Turf " 23 75 ne RI O G R A N D E P L A C E As per WELS Section 5.2.3, narrow areas less than 10 feet in dimension, including turf grass areas, shall not use overhead sprinkler irrigation. Revise plans accordingly. 1" A18 3.50 Inline 4 What are the zone design pressures for all the valves on this system? 411" 411" 1" A2223.5 Turf 1" A23 6.75 Inline 10 RI O G R A N D E P L A C E All trees (8) should be on separate valves from turf grass areas where feasible, as per Section 5.2.7 Page: IR-4 - IRRIGATION PLAN Author: rickma Date: 4/1/2019 9:21:23 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf What is the available static water pressure at this POC (point of connection)? Describe the water source, design water pressure, and operational characteristics for this system, and the location of system components such as irrigation controller, back-flow prevention device, flow sensor, etc. IR-4 - IRRIGATION PLAN (4) Page: IR-4 - IRRIGATION PLAN Author: rickma Date: 4/1/2019 9:41:36 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf All trees (12) should be on separate valves from turf grass areas where feasible, as per Section 5.2.7 Page: IR-4 - IRRIGATION PLAN Author: rickma Date: 3/21/2019 1:48:24 PM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf As per WELS Section 5.2.3, narrow areas including turf grass areas less than 10 feet in dimension shall not use overhead sprinkler irrigation. Revise plans accordingly. Page: IR-4 - IRRIGATION PLAN Author: rickma Date: 4/1/2019 8:58:03 AM File Name: Plan Set.Irrigation.425 Rio Grande Place.2019.03.pdf As per WELS Section 5.2.3, narrow areas including turf grass areas less than 10 feet in dimension shall not use overhead sprinkler irrigation. Revise plans accordingly. 2 8 10 What is the available static water pressure at this POC (point of connection)? Describe the water source, design water pressure, and operational characteristics for this system, and the location of system components such as irrigation controller, back-flow prevention device, flow sensor, etc. 411" 411" 2"411"411" 411" 1" 222.2 Turf1.5" 343.9 Turf 1" 4 17.7 Turf 9 9 MA T C H L I N E : S E E S H E E T I R - 3 RI O G R A N D E P L A C E N. M I L L S T R E E T All trees (12) should be on separate valves from turf grass areas where feasible, as per Section 5.2.7 411" As per WELS Section 5.2.3, narrow areas including turf grass areas less than 10 feet in dimension shall not use overhead sprinkler irrigation. Revise plans accordingly. 411" As per WELS Section 5.2.3, narrow areas including turf grass areas less than 10 feet in dimension shall not use overhead sprinkler irrigation. Revise plans accordingly. Page: L0-04 - GENERAL INFORMATION Author: rickma Date: 3/26/2019 11:05:34 AM File Name: Plan Set.Landscape.425 Rio Grande Place.2019.03.pdf Please include the language of WELS Sections 4.1 and 4.2 regarding soil and mulch. L0-04 - GENERAL INFORMATION (1) Page: L7-10 - SITE DETAILS Author: rickma Date: 3/26/2019 4:09:44 PM File Name: Plan Set.Landscape.425 Rio Grande Place.2019.03.pdf Please indicate the location and extent of the bioswales on planting plans L7-10 - SITE DETAILS (1) Page: L8A-01 - PLANTING PLAN Author: rickma Date: 4/1/2019 8:12:39 AM File Name: Plan Set.Landscape.425 Rio Grande Place.2019.03.pdf As per WELS Section 5.2.8, Hydrozone areas shall be "designated...on the landscape design plan and irrigation design plan". Please provide this information on the landscape plans or on separate sheets. Hydrozones areas are not necessary on the irrigation design plans in this case. L8A-01 - PLANTING PLAN (1) ents at 90 degree angles to each other unless otherwise noted. s where concrete flatwork meets vertical structures such as walls, curbs, ments. cated from finished face of buildings. kways shall be located as shown on plan. OTES ovided mixed and ready for installation. nate with Owner's Representative for location of stockpile areas for stripped products. Contractor shall ensure area is protected and contamination or roducts is not allowed. subgrade is scarified prior to installing planting soil and blend with initial lift or planting soil. is larger than 2-inch diameter shall be removed and legally disposed of offsite d planting soil. Please include the language of WELS Sections 4.1 and 4.2 regarding soil and mulch. swale Please indicate the location and extent of the bioswales on planting plans AS PLANTING PLAN As per WELS Section 5.2.8, Hydrozone areas shall be "designated...on the landscape design plan and irrigation design plan". Please provide this information on the landscape plans or on separate sheets. Hydrozones areas are not necessary on the irrigation design plans in this case. Page: L8A-02 - PLANTING PLAN Author: rickma Date: 4/1/2019 3:58:15 PM File Name: Plan Set.Landscape.425 Rio Grande Place.2019.03.pdf These areas are called out as bio-retention ponds in the Civil drawings (C19, C20). Please delineate them as bio-retention areas on this plan. Planting trees in these features may affect desired effectiveness due to tree roots dominating the spaces over time. Consider keeping trees on upper perimeter of the ponds and reducing the number of trees per feature. L8A-02 - PLANTING PLAN (1) 7884 788 5 7 8 8 3 7 8 8 4 7 8 8 2 P R O P E R T Y B O U N D A R Y (4) XX-3 9.5 (1002 SF) XX-1 TYP. (4) XX-2.5 (205 SF) XX-1 These areas are called out as bio-retention ponds in the Civil drawings (C19, C20). Please delineate them as bio-retention areas on this plan. Planting trees in these features may affect desired effectiveness due to tree roots dominating the spaces over time. Consider keeping trees on upper perimeter of the ponds and reducing the number of trees per feature.