Loading...
HomeMy WebLinkAboutFile Documents.210 W Main St.0056.2019 (94).ARBKZoning 1_0056.2019.ARBK - 210 W Main 4-26-2019 Page Label: A.1.01 ZONING SUMARY Page Index: 5 Author: sophiev Date: 4/26/2019 1:28:54 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please update these to match sheets referenced. DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf (8) Page Label: A.1.04 PROPOSED SITE PLAN Page Index: 8 Author: sophiev Date: 4/26/2019 2:12:44 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please provide this for the east and west sideyard setbacks in all applicable sheets. Page Label: A.1.06 EXISTING FAR CALCULATIO NS Page Index: 10 Author: sophiev Date: 4/26/2019 1:30:04 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please update all existing and proposed FAR and Net Leasable/Livable sheets per our meeting 04/23/2019 Page Label: A.1.1 HEIGHT OVER TOPOGRAPH Y-ROF Page Index: 15 Author: sophiev Date: 4/26/2019 3:19:09 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please rectify the natural grade to match the survey. See attached survey for example points where survey and table don't appear to match. Page Label: A.2.02 EXISTING MAIN LEVEL PLAN Page Index: 23 Author: sophiev Date: 4/26/2019 1:39:54 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please update as commercial space. Page Label: A.2.06 PROPOSED MAIN LEVEL PLAN Page Index: 27 Author: sophiev Date: 4/16/2019 12:53:02 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please show compliance with 26.515.070 - Off-Street Parking Requirements. Page Label: A.3.03 PROPOSED ELEVATIONS: NORTH & EAST Page Index: 33 Author: sophiev Date: 4/16/2019 12:53:15 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please show compliance with 26.515.070 - Off-Street Parking Requirements. 26.575.020.D.7. isting Floor Area s.f.Proposed Gross s.f.Proposed Floor Area s.f. Reference for math 710 2144 0 A.1.05, A.1.6, A1.7, A1.8 1742 2615 2444 A.1.05, A.1.6, A1.7, A1.8 964 3053 3008 A.1.05, A.1.6, A1.7, A1.8 1768 1818 A.1.05, A.1.6, A1.7, A1.8 0 948 0 A.1.05, A.1.6, A1.7, A1.8 3416 10528 7270 Street facing porched, gazebos and similar features, unless the nt (15%) of the allowable floor area for the propoerty and the 75.020.D.7: For all multifamily building, parcels containing more e garage or carpost area shall be exluded from the calculation of Please update these to match sheets referenced. S KING LOUISE H IF THENOTEXAHARE PR S DATE 11/22/ 03/05/ MAIL BOX18"D X 30 1/2"WX62"H BRONZE EXISTING TREE LAWN LAWN PORCH WALKWAY WALKWAY PORCH MAIN STREET F 65 D G E SETBACK LINE PROPERTY LINE PATIO/BALCONY SETBACK LINE (HPC RESOLUTION #12 OF 2018) Please provide thisfor the east and west sideyard setbacks in all applicable sheets. TOT Please update all existing and proposed FAR and Net Leasable/Livable sheets per our meeting 04/23/2019 2A 3.1 6 3 5 4 P SCALE: 3/16" = 1'-0" ROOF PLAN Please rectify the natural grade to match the survey.See attached survey for example points where surveyand table don't appear to match. 1 2 3 4 5 UP Custom T 2A 3.1 BEDROOM BATH KITCH APT. 4 BEDROOM BATH KITCH LIVING APT. 3 CLOSET APT. 8 APT. 7 KITCHEN BATH KITCHEN STUDIO BATH GRAVELPARKING UPDN 1A 5.3 1A 5.3 A SETBACK LINE PROPERTY LINE Please update ascommercial space. 12345678910111213141516 101-06 101-05 101-01 101-05 101-04 101-03 101-11 101-01 101-02 103-08 103-07103-10 103-09 103-11 102-07 101-10 101-08 101-03 101-04 10102-03 103-07 103-08 103-06 103-02 101-02 101-06 101-04 101-09 101-07 103-05 103-04 103-03 00-12 N D F W W D RG 1A.6.06 2A.6.06 80'-11" 80'-11" 49'-3" 12'-9 1/2"24'-2 1/2"5'-0"16'-8 1/2" 12'-9 1/2"24'-2 1/2"5'-0"16'-8 1/2" 5'-0"3'-8 1/2" 3 1/2"8'-0" 3 1/2"11'-11"3 1/2"11'-5"3 1/2"3 1/2" 12'-10" 5 1/2" 7'-11 1/2" 3 1/2" 22'-9" 3 1/2"11'-4"3 1/2"10'-4"3 1/2 3 1/2"11'-4"5 1/2"5'-10 1/2"3 1/2"9'-0 3 1/2"11'-1 3 1/2" 3 1/2" 2'-8"3 1/2"5'-5 3 1/2" 4'-1" 3 1/2" 3 1/2"4'-4"3 1/2" 4'-0" 2'-6" 3 1/2"3'-1 1/4" 3'-1 1/4" 2'-0" 5'-0" 10'-8 1/2" 3 1/2" 6'-10 1/2" 3 1/2"2'-4 3/4"3 1/2" 3 1/2"2'-7 1/4" 3 1/2" 12'-9" 3 1/2"2'-1"3 1/2" 5'-11" 3 1/2" 4'-0" 2'-6"4'-0" 2'-6" 5'-5" 2'-0" 3'-8"3 1/2"6'-4 1/2" 3 1/2" 11'-9 3/4" 3 1/2"2'-2"3 1/2" 9'-6 1/4" 3 1/2" 14'-5 1/4" 3 1/2" 9'-6 3/4" 3 1/2" 7'-4 1/2"3 1/2"3'-8" 3 1/2" 14'-11 1/2" 3 1/2" 3'-0 3/4"3 1/2"11'-11 3/4" 3 1/2"10'-8 1/2" 2'-8"3 1/2"3 1/2" 4'-1" 8'-0"3 1/2"3'-7"3'-10 1/2"3 1/2"7'-2" 3 1/2"2'-1" 7'-6" 8'-6" T GYP100'-0"T PLY99'-10 1/2" 2A 3.1 2A 3.1 2A 3.1 1 HR FIREWALL HALL BEDROOM 2 BEDROOM 1 BATH 1 LAUNDRY BEDROOM 2BEDROOM 1 LIVING DINING KITCHEN BATH(ADA TYPE B) PANTRY UNITSTORAGE UNITSTORAGE TRASH HALL POWD BATH 2(ADA TYPE B) * NOTE:CLOSET DOOR TO HAVE 31 3/4"DOOR CLEARANCE * NOTE:CLOSET DOOR TO HAVE 31 3/4"DOOR CLEARANCE * NOTE:CLOSET DOOR TO HAVE 31 3/4" DOORCLEARANCE * NOTE:CLOSET DOOR TO HAVE 31 3/4" DOORCLEARANCE UPDN UTILITIES 00-14 00-15 00-13 F 2 2 A 3 3 5 5 B C D G E 4 4 1 1 1A 5.1 2A 5.1 3A 5.2 4A 5.2 1A 5.3 1A 5.3 1A 5.3 1A 5.3 SETBACK LINE PROPERTY LINE PROPERTY LINE UNIT 101 ST-101 ST-103 GARBAGE SCALE: 1/4" = 1'-0"1 PROPOSED GROUND LEVEL Please showcompliance with26.515.070 -Off-Street ParkingRequirements. 2 1 7'-8" B SIDING TYP. T.O. F.F @ GROUND LEVEL100'-0" T.O. F.F. @ SECOND LEVEL109'-4" T.O. BASEMENT SLAB89'-8" Please show compliance with 26.515.070 - Off-Street Parking Requirements. Page Label: A.8.0 RCP PLANS Page Index: 51 Author: sophiev Date: 4/9/2019 1:29:44 PM File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Submittal 030519.pdf Please show compliance with 26.575.150.E.b. - Nonresidential Lighting Standards; if outdoor lighting is above 12' high, the light must be both fully shielded and the point light is not visible beyond the boundaries of the property OR it is otherwise approved in Subsection 27.575.150.K Page Label: 5 Page Index: 5 Author: sophiev Date: 4/26/2019 1:19:43 PM File Name: DR 04. MECHANICAL Plans.pdf Please show the location of the outdoor units for AC-1 and HP-1 and any other exterior mechanical equipment. DR 04. MECHANICAL Plans.pdf (1) G LOUISE HOUSING 210 WEST MAIN STREET ASPEN, CO 81611 ALL DESIGNS, IDEAS ARRANGEMENTSAND PLANS INDICATED BY THESEDRAWINGS AND SPECIFICATIONS ARETHE PROPERTY AND COPYRIGHT OF KIMRAYMOND ARCHITECTS, INC. ANDSHALL NEITHER BE USED ON ANY OTHERWORK NOR BE USED BY ANY OTHERPERSON FOR ANY USE WHATSOEVERWITHOUT WRITTEN PERMISSION.WRITTEN DIMENSIONS SHALL TAKEPRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECTPRIOR TO COMMENCEMENT OF WORK. KIM RAYMOND ARCHITE | 300 E. HYMAN AVENUE, SUI | www.kimraymondarchitects | 970-925-2252 | 6354 12345678910111213141516 CEILING: 8' CEILING: 8' CEILING: 8' CEILING: 8' CEILING: 8' CEILING: 8'CEILING: 8'CEILING: 8' SIDEWALK LIVING DINING KITCHEN PORCH DININGHALL BEDROOM 2 BEDROOM 1 BATH 1 LAUNDRY LIVING KITCHEN PORCH UP POWDER BATH 2(ADA TYPE B) * NOTE:CLOSET DOOR TO HAVE 31 3/4"DOOR CLEARANCE * NOTE:CLOSET DOOR TO HAVE 31 3/4"DOOR CLEARANCE * NOTE:3/4" DOORCLEARANCE UPDN S S S R SS S S S S S S S S R R R R R R R R SD+CO2 SD+CO SD+CO MAIL BOXES SETBACK LINE PROPERTY LINE PROPERTY LINE PATIO/BALCONY SETBACK LINE (HPC RESOLUTION #12 OF 2018) UNIT 102 UNIT 103 +6'-3" SINGLE SWITCH THREE-WAY SWITCH PHONE FEED COMPUTER DATA OUTLET SMOKE DETECTOR+CARBON MONOXIDE WALL SCONCE HEAT RECOVERY VENTILATOR SD+CM Please showcompliance with26.575.150.E.b. - NonresidentialLighting Standards; ifoutdoor lighting isabove 12' high, thelight must be both fully shielded and thepoint light is notvisible beyond the boundaries of theproperty OR it isotherwise approved in Subsection27.575.150.K Please show the location of the outdoor units for AC-1 and HP-1 andany other exterior mechanical equipment.