HomeMy WebLinkAboutFile Documents.834 W Hallam St.0010.2018 (89).ARBKSPECIFICATION SHEET
TAG _______
Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice
* Regularly furnished unless otherwise specified.
Zurn Industries, LLC | Specification Drainage Operation
1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929
In Canada | Zurn Industries Limited
3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292
www.zurn.com
Rev. AD
Date:07/18/14
C.N. No.131244
Prod. | Dwg. No. Z806
ENGINEERING SPECIFICATION: Zurn Z806
Channels shall be 120 [3048] long, 6 [152] wide and have a 4 [102] throat. Modular channel sections shall be made of Fiber Reinforced Polymer
(FRP). Shall have a positive mechanical connection between channel sections that will not separate during the installation and shall mechanically
lock into the concrete surround every 10 [254]. Channels shall weigh less than 2.31 lbs.[1.05kg] per linear foot, have a smooth, 1-1/2 [38] radiused
self cleaning bottom with a Manning’s coefficient of .009 and .75% or neutral 0% built in slope. Shall be provided with standard DGC grates that
lock down to frame. Zurn 6 [152] wide reveal Ductile Iron Slotted Grate conforming to ASTM specification A536-84, Grade 80-55-06. Ductile Iron
grate is rated class C per the DIN EN1433 top load classifications. Supplied in 20 [508] nominal lengths with 1/2 [13] wide slots, and 3/4 [19] bearing
depth. Grate has an open area of 18.57 sq. in per ft. [39,307 sq. mm per meter]. The 1/4 [6] thick Heavy-Duty Carbon Steel Frame Assembly conforms
to ASTM specification A36 with 12-4 [102] long concrete anchors per 120 [3048]. Grate lockdown bars are to be integral to the frame. The frame
is supplied with a powder coated finish. All welds must be performed by a certified welder per ASTM standard AWS D1.1. Frames Shall be produced
in the U.S.A.
Trench 'A' 'B'Flow
No. Shallow Inv. Deep Inv.(cfs)(gpm)(lps)
1001 3.50 [89] 4.40 [112] .196 88 6
1002 4.40 [112] 5.30 [135] .296 133 8
1002N 5.30 [135] 5.30 [135] - - -
1003 5.30 [135] 6.20 [157] .397 178 11
1004 6.20 [157] 7.10 [180] .501 225 14
1004N 7.10 [180] 7.10 [180] - - -
1005 7.10 [165] 8.00 [203] .604 271 17
1006 8.00 [203] 8.90 [203] .711 319 20
1007 8.90 [226] 9.80 [249] .816 366 23
1008 9.80 [249] 10.70 [272] .922 414 26
1008N 10.70 [272] 10.70 [272] - - -
1009 10.70 [272] 11.60 [295] 1.029 462 29
1010 11.60 [295] 12.50 [318] 1.136 510 32
NOTE: + Actual Channel length is 122 1/2 [3112] to allow for overlap.
PREFIX OPTIONS (Check/specify appropriate options)
____Z Ten-foot Fiber Reinforced Polymer (FRP)*
____ ZV Ten-foot Fiber Reinforced Vinylester
SUFFIX OPTIONS (Check/specify appropriate options)
Outlet Adapters Add/Each
____-E1 Closed End Cap ___ -U2 2 [51] No-Hub Bottom Outlet
____ -E2 2 [51] No-Hub End Outlet ___ -U3 3 [76] No-Hub Bottom Outlet
____ -E3 3 [76] No-Hub End Outlet ___ -U4 4 [102] No-Hub Bottom Outlet
____ -E4 4 [102] No-Hub End Outlet ___ -U6 6 [152] No-Hub Bottom Outlet
____ -E6 6 [152] No-Hub End Outlet
Z806
6 [152] WIDE REVEAL FIBER REINFORCED
POLYMER TRENCH DRAIN SYSTEM
Frame Options
____ -CBF Black Acid Resistant Coated Frame
____ -HD Extra-Heavy-Duty Frame Assembly with Anchor Studs *
Grate Options (Load Classifications are per DIN EN1433)
____ -BDC Black Acid Resistant Epoxy Coated Ductile Grate - Class C
____ -BDE Black Acid Resistant Epoxy Coated Ductile Grate - Class E
____ -BG Galvanized Ductile Iron Cast Bar Grate - Class C
____ -DBG Ductile Iron Cast Bar Grate - Class C
____ -DC Ductile Iron Solid Cover - Class C
____-DGC Ductile Iron Slotted Grate - Class C *
____ -DGE Ductile Iron Slotted Grate - Class E
____-DGE-NA Ductile Iron Slotted Grate - Class E - North American
____-GDC Galvanized Ductile Slotted Grate - Class C
____ -GDE Galvanized Ductile Slotted Grate - Class E
____ -GG Fiberglass Grate - Class A
____ -GHPD Galvanized Heel-Proof Ductile Grate - Class B
____-GHPDE Galvanized Heel-Proof Ductile Grate - Class E
____ -HPD Heel-Proof Ductile Slotted Grate - Class B
____ -HPDE Heel-Proof Ductile Slotted Grate - Class E
____ -HPP Heel-Proof Polyethylene Grate - Class A
____ -LD Ductile Iron Longitudinal Slotted Grate - Class B
____ -RFG Reinforced Galvanized Steel Slotted Grate - Class B
____ -RPG Reinforced Galvanized Perforated Grate - Class B
____-RFGC Reinforced Slotted Galvanized Grate - Class C
____ -RFSC Reinforced Slotted Stainless Steel Grate - Class C
____ -RPGC Reinforced Perforated Galvanized Grate - Class C
____ -RPGR Reinforced Galvanized Perforated Reverse Punch
Anti-Slip ADA Grate - Class C
____ -RPGRC Reinforced Perforated Galvanized Reverse Punch Grate -Class C
____ -RPSC Reinforced Perforated Stainless Steel Grate - Class C
____ -RPSR Reinforced Stainless Steel Perforated Reverse Punch
Anti-Slip ADA Grate - Class B
____ -RPSRC Reinforced Perforated Stainless Steel Reverse Punch Grate - Class C
Decorative Grate Options (Load Classifications are per DIN EN1433)
____ -BCD Bronze Circular Decorative Grate - Class A
____ -BDD Bronze Diagonal Decorative Grate - Class A
____-DCD Ductile Iron Circular Decorative Grate - Class C
____-DDD Ductile Iron Diagonal Decorative Grate - Class A
____ -DOG Ductile Iron Decorative Grate - Class A
____ -DTW Ductile Iron Tidal Wave Grate - Class C
____-DWV Ductile Wave Decorative Grate - Class A
____ -HPB Heel-Proof Bronze Slotted Grate - Class A
____ -HPS Heel-Proof Stainless Steel Slotted Grate - Class A
____-SBG Stainless Steel Bar Grate - Class E
MADE in the U.S.A. (Load Classifications are per DIN EN1433)
____ -AWG Aluminum Wire Grate - Class A
____ -BDE-USA Black Acid Resistant Epoxy Coated Ductile Grate -
Class E
____-DCE-USA Ductile Iron Solid Cover - Class E
____-DGC-USA Ductile Iron Slotted Grate - Class C
____ -DGE-USA Ductile Iron Slotted Grate - Class E
____ -FG Fabricated Galvanized Steel Slotted Grate - Class A
____ -FS Fabricated Stainless Steel Slotted Grate - Class A
____-GDC-USA Galvanized Ductile Slotted Grate - Class C
____ -GDE-USA Galvanized Ductile Slotted Grate - Class E
____ -GHPDE-USA Galvanized Heel-Proof Grate - Class E
____-GMG Galvanized Steel Mesh Grate - Class B
____ -HPDE-USA Heel-Proof Ductile Slotted Grate - Class E
____ -PG Perforated Galvanized Steel Grate - Class A
____ -PGR Galvanized Perforated Reverse Punch
Anti-Slip ADA Grate - Class A
____ -PPC Plastic Perforated Grate - Class C
____ -PS Perforated Stainless Steel Grate - Class A
____ -PSR Stainless Steel Perforated Reverse Punch Anti-Slip
Grate - Class A
Decorative MADE in the U.S.A. (Load Classifications are per DIN EN1433)
____ -BZ Bronze Decorative Grate - Class A
____ -NBZ Nickel Bronze Decorative Grate - Class A
____ -PDE-USA Ductile Iron Perforated ADA Grate - Class E
____ -PSR Stainless Steel Perforated Reverse Punch
Anti-Slip Grate - Class A
____ -SWG Stainless Steel Wire Grate - Class A
____ -SCD Stainless Steel Circular Decorative Grate - Class B
____ -SDD Stainless Steel Diagonal Decorative Grate - Class B
____-SMG Stainless Steel Mesh Grate - Class B
____-SOG Stainless Steel Decorative Grate - Class B
Miscellaneous Options
____ -DB Bottom Dome Strainer
____ -JC Joint Connector
____ -RC Rebar Clip (Set of 2)
____ -SW 8.1 [206] High Sidewall Extension Adapter (Per Pair)
____ -VP Vandal-Proof Lockdown
The Q100 for Basin-D is only 0.19 cfs which is less than
50% of the capacity of 0.50 cfs indicated below.
04/13/2018