HomeMy WebLinkAboutFile Documents.320 N 7th St.0111-2021-BRES (8) 0111 -2021 -BRES_ZoningComments_1 90.Architectural Plans.20210727.pdf(25) -r Subject: Cloud+ Page:Z-000 ZONING SUMMARY Need height of planter-is it Page Index: 3 greater than 30"? --_- -_- Author: haleyh Color: • File Name: 90.Architectural Plans.20210727.pdf Response: Planter removed&deck calculations updated. Detail/Page:A-002 Subject:Text Box FI°°rArea Summa Page:Z-000-ZONING SUMMARY Cannot determine if the roof Unil 1 Main Level Unit z Main Level overhangs are greater than 4'-if Gnit3G ,Laval Page Index: 3 Und]Ga Lori so that area is deck. Author: haleyh Unit,PataArea Color: • zPa°a Area File Name: 90.Architectural Plans.20210727.pdf Un l Area Una il l Deck Area Unit,Sae'Are° Response: Roof overhangs dimensioned for clarity. Unit I Shed Area Unit,ExledorAree Detail/Page:A-002E,A-120E,A-002,A-120 Una 2 Exterior Area Subject: Cloud+ Page:Z-000-ZONING SUMMARY 44?993.88?See A 002 for -_ - Page Index: 3 calculations. Author: haleyh asNIX6 Color: • -- �t_� File Name: 90.Architectural Plans.20210727.pdf l��N� �,:„e r NCTIIM z-000 Response:Proposed floor areas&calculations revised. —„— Detail/Page:Z-000,A-002 o A_00 Subject: Cloud+ o A-0O Page:Z-000-ZONING SUMMARY Update N/A A-0o Page Index: 3 Aazoe A-oo Author: haleyh Color: ■ File Name: 90.Architectural Plans.20210727.pdf Update Response:Proposed floor areas&calculations revised. Detail/Page:Z-000,A-002 Subject: Image Page:Z-000-ZONING SUMMARY Page Index: 3 -- --- _ Author: haleyh Color: ■ File Name: 90.Architectural Plans.20210727.pdf Response:N/A Detail/Page:N/A RECEIVED 05/23/2022 ASPEN BUILDING DEPARTMENT Subject: Cloud+ Page:Z-000-ZONING SUMMARY I am getting 998.52 use one hundredth percent decimal when Page Index: 3 calculating-this means the total pp Author: haleyh == Color: ■ would be 999 sf File Name: 90.Architectural Plans.20210727.pdf Response:Proposed&Existing floor areas&calculations revised.We are using the one hundredth decimal place in updated calculations. Detail/Page:Z-000,A-002E,A-002 Subject: Cloud+ Page:Z-000-ZONING SUMMARY 3601.8*15%=540sf Page Index: 3 Author: haleyh Color: ■ � � __� File Name: 90.Architectural Plans.20210727.pdf Response: N/A Detail/Paqe: N/A Subject: Cloud+ Page:Z-000-ZONING SUMMARY It is 3,601.8 Page Index: 3 11s3,601.8 Author: haleyh Color: • File Name: 90.Architectural Plans.20210727.pdf Reforence M in Nei Lot Area.up me mrnm 3.�a 36.313.030.E 28.710.010 Response: N/A vntb.d.ne require Co. Detail/Page:N/A Subject: Cloud+ - _ Page:Z-000-ZONING SUMMARY How is the area of the building __ _ Page Index: 3 footprint changing for Unit 1 if ri ,M .M. 3 Author: haleyh this is a permit for Unit 2 and - Color: ■ they are detached? File Name: 90.Architectural Plans.20210727.pdf ti Response:The shed is in the common area between the units&is being modified.We have submitted a letter from the owner of Unit - _ 1 approving the shed modifcation. --- Detail/Page:A-110E,A-110 0 7 Subject: Cloud+ 40 18 Page:Z-000-ZONING SUMMARY Update N/A 216 Page Index: 3 N/A 171 Author: haleyh 3404 3818 Color: ■ File Name: 90.Architectural Plans.20210727.pdf Update Response:Proposed&Existing floor areas&calculations revised. Detail/Page:Z-000,A-002E,A-002 RECEIVED 05/23/2022 ASPEN BUILDING DEPARTMENT Subject: Cloud+ Page:Z-000-ZONING SUMMARY Page Index: 3 Author: haleyh Color: • File Name: 90.Architectural Plans.20210727.pdf Response: N/A Detail/Page: N/A Subject: Cloud+ • Page:Z-000-ZONING SUMMARY Update because allowed FA Page Index: 3 calculations are off. Author: haleyh Color: ■ File Name: 90.Architectural Plans.20210727.pdf �laen^^BeR Response: Existing floor areas&calculations revised. Detail/Page:Z-000,A-002E Countable Area(Sq Ft) Comments Subject: Cloud+ 1558 Update 1535 Page:A-002E-EXISTING FLOOR AREA CALCULATIONS p 263 Page Index: 8 40 Author: haleyh EA 3404 INON-CONFORMING Color: ■ H Update File Name: 90.Architectural Plans.20210727.pdf Response:Proposed&Existing floor areas&calculations revised. Detail/Page:Z-000,A-002E,A-002 Subject:Text Box Unit 2? Page:A-002E-EXISTING FLOOR AREA CALCULATIONS Page Index: 8 Author: haleyh Unit 2? Color: • File Name: 90.Architectural Plans.20210727.pdf Response:Unit 2 note added for clarity. Detail/Page:A-002E,A-002 1.6 Subject: Cloud+ ea Ma „ Page:A-002E-EXISTING FLOOR AREA CALCULATIONS I am getting 998.52; exposed I'°la'•5.are.' Page Index: 8 wall area percentage is 94.22 saxGRADE FLOOR AREA CALC Author: haleyh ;Zrn=n-417, 1= ,44N Color: ■ l area exposed wall areamgetling 9 File Name: 90.Architectural Plans.20210727.pdf percentage Is 94.22 Response:Existing subgrade calculations revised. Detail/Page:A-002E RECEIVED 05/23/2022 ASPEN BUILDING DEPARTMENT Subject:Text Box I Page:A-002E-EXISTING FLOOR AREA CALCULATIONS Is this roof projection greater I Page Index: 8 than 4'? If so, it counts as deck Is Inge roof prole.,Srea FA. Author: haleyh 26.575.020.0.6.:When roof Color: • �l a"J,e°"9BX0ee°s w'a,'eB""e 26.575.020.D.6.:When roof °'OfeCOO` °F'°°' File Name: 90.Architectural Plans.20210727.pdf nree.Re ermaermefixed galls overhangs or similar see11n8.permanently fixed galls, Response:Roof overhangs dimensioned for clarity.The architectural projections exceed f 202102-22 roof projection in question does not exceed 4'. four(4)feet,the entire feature ISSUE Detail/Page:A-002E,A-120E,A-002,A-120 counts toward Floor Area. rrrr PERMIT SET Railing, permanently fixed seating, permanently fixed grills, and similar permanently fixed features located on patios shall count toward deck calculation SubjPage:ect:A-002E- 3/16"Scale EXISTING FLOOR AREA CALCULATIONS 4'-1" \ Page Index: 8 Author: haleyh x-/ / , Color: • 4'-1° File Name: 90.Architectural Plans.20210727.pdf Response: Roof overhangs dimensioned for clarity.The roof projection in question does not exceed 4'. I Detail/Page:A-002E,A-120E,A-002,A-120 — °w° Subject: Cloud+ Page:A-100E-SITE PLAN-EXISTING Demo? Please give detail about 1 the extent of refinishing. If going Page Index: 9 Author: haleyh down to stud, this will constitute demo. Color: • � � `' File Name: 90.Architectural Plans.20210727.pdf Response:We are replacing the wood decking&sleepers and applying a new membrane over the existing framing.The existing "�; roof sheathing and framing will remain. Detail/Page: F3E/A-500 Subject: Cloud+ Per Sheet A 510,these planters — ——I , I � � I �� Page:A-002-PROPOSED FLOOR AREA CALCULATIONS Page Index: 17 are not 30" in height,therefore _; are not exempt. ..p- _. Author: haleyh n µ E Color: • 4m_ ' m € File Name: 90.Architectural Plans.20210727.pdf 26.575.020 D.4 e.The area of i .,,,-7,7 ,.„,-,ilthe following features count -0 I I� l �� Response: Planter removed&deck calculations toward deck calculation: railing, -0 II ° updated. permanently fixed seating, -0 Detail/Page:A-002 permanently fixed grills, and similar permanently fixed features. Permanent planter boxes and green roofs that are a minimum of thirty(30)inches in height above or below the deck surface, measured from the deck surface to the bottom of the planter box or green roof surface, and that are permanently built into the structure of the roof or deck are not included in the deck calculation. Permanent planter boxes and green roofs that do not meet the minimum i - f\ i t_ ' requirement count tic/t i rd kler4( L;i calculation. 05/23/2022 ASPEN BUILDING DEPARTMENT Subject: Cloud+ Page:A-002-PROPOSED FLOOR AREA CALCULATIONS 1. Garage exemption: g (250+44=294) Page Index: 17 ��- I' Author: haleyh 338-294=44 m.uvw Color: ■ File Name: 90.Architectural Plans.20210727.pdf 2•Add garage with exemption to total main floor's FA: Response:Proposed subgrade floor area calculations 44+987=1031 I I I I revised. Detail/Page:A-002 3.THEN apply subgrade \\\ exposed wall percentage: 1031*.036=37.12 1031-37.12=993.88 Per 26.575.020.D.8 Subgrade Areas: For garages that are part of a subgrade area, the garage exemption is taken from the total gross below-grade area prior to calculating the subgrade exemption. z, P =FE ,„, Subject: Cloud+ e"'OROD" Page:A-002-PROPOSED FLOOR AREA CALCULATIONS Update IEA CALCULATION Page Index: 17 re"°Fl` m, Author: haleyh RARE, ddPORM Color: • File Name: 90.Architectural Plans.20210727.pdf trade. Response:Proposed floor areas&calculations revised. Detail/Page:A-002 <:r poi P® jra Subject: Cloud+e' \y Need more detail for all of the g Pa e:A-002-PROPOSED FLOOR AREA CALCULATIONS I I >� PROP Page Index: 17 covered patio areas. `"- Author: haleyh �.1__,UX_ J 1.J Color: ■ LJ A File Name: 90.Architectural Plans.20210727.pdf PROPOSED M N LEVEL FLOOR EEEEd l _tt." Response:Roof overhangs dimensioned for clarity. Detail/Page:A-002,A-120 fav Subject: Cloud+ ` No permanent affixed grills on a �- - Page:A-100-SITE PLAN -PROPOSED Page Index: 18 deck that is street-facing.You E __- i, Author: haleyh can put a movable grill that is not -7--,ust7 - Color: • hard-lined if you would like. Ik File Name: 90.Architectural Plans.20210727.pdf 26.575.020: ' /L Response:Grill removed7 m.Hot tubs, spas, pools,water _ r;411 =_ Detail/Page:A-100 features, and permanently ,440111111 affixed outdoor grills,furniture, seating areas, and similar permanent structures shall have the following requirements:l.Prohibited between any lot line adjacent to a street and any structure RECEIVED 05/23/2022 ASPEN BUILDING DEPARTMENT - Subject: Cloud+ Page:A-111 -UPPER LEVEL PLAN-PROPOSED Cannot be built in Page Index: 21 Cannot be built in Author: haleyh Color: ■ File Name: 90.Architectural Plans.20210727.pdf BUILT-IN -S BBQ GRILL,RE: - ArP A C SCHEDULE Response:Grill removed. WOOD FRAMED STEPS TO Detail/Page:A-100 ART STUDIO LEVEL.3 RISERS AT 6 7/8"EA. GOROH ROOF DETAIL it EMT WITH DRIP Subject: Cloud+ Page:A-510-DETAILS Must be greater than 30"to be Page Index: 29 exempt from deck FA. If you Author: haleyh want to exempt this, increase the mrtw— j� Color: • height or depth. File Name: 90.Architectural Plans.20210727.pdf * ■ ■ Response:Planter removed&deck calculations ■ ■ updated. AM. YF ,ham �F Detail/Page:A-002 90.Landscape Plans.20210727.pdf(1) Subject: Cloud+ Front fence cannot exceed 42" in Page: 1 front: _ Page Index: 1 Author: haleyh Its 26.575.020.4.D. Fences and I� Color: ■ p File Name: 90.Landscape Plans.20210727.pdf hedges less than forty-two(42) inches in height, as measured r Response:Proposed fence height revised from finished grade, are • d " Detail/Pa e:L.2.001 permitted in all required yard 7.'°;4.4), g setbacks. Fences and hedges up to six(6)feet in height, as measured from finished grade, are permitted only in areas entirely recessed behind the vertical plane established by the portion of the building facade which is closest to the Street. This restriction applies on all Street-facing facades of a parcel. (Also see Section 26.575.050—Supplementary Regulations for limitations on fence materials.) Additional Comments 1/20: 1. Need a signed City of Aspen HOA form in your second submittal. Response: Form submitted with initial application(file name: 10.Permit Application Packet.20210727 Page 2) 2. I missed the note you had put under allowable floor area -good call -you are correct, this would fall under the non-conformity language and you would have an allowable FA under the single-family residential standards. Please disregard my comments on your allowable floor area. Response:Comments disregarded. 3. It looks like there is a shed on the property of Unit 1 that looks like it is going to be torn down and redone.This shed is within the 10' separation setback between the two dwelling units.This shed cannot project into this 10' separation setback. Please either remove it and replace it not within a setback, or not touch it at all. Response:The shed is being rebuilt to provide the 10'separation distance.We have submitted a letter from the owner of Unit 1 approving the shed modification. Detail/Page:A-100 ' I 41 I.[— 4. Please show you are not extending any removed and replaced fascia or the siding of the house (ie: you canhof exte d i non-conforming elements and these are already projecting into 10' separation setback) 05/23/2022 Response:Detail added to show that that we will not increase the existing non-conforming condition. Detail/Page:4/A-510 ASPEN BUILDING DEPARTMENT