Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.320 N 7th St.0019-2023-BCHO (7)
TECHNICAL INFORMATION SHEET VZ> PRODUCT DATA Color: 32 standard colors;see current Ultra-Clad Color Chart Finish: Extra Smooth Matte-Low to Medium Gloss Optional Finish: Inquire COATED METALS GROUP Wash Coat: Polyester Kynar 500/Hylar 5000 Weight: Pre-Finished Galvalume® Steel Gauge: lb/SF: Architectural Sheet& Coil 22ga 1.25 .0285min-.0313max 24ga 1.00 .0225min-.0254max DESCRIPTION: 26ga 0.75 .0172min-.0194max CMG Ultra-Clad PVDF Coated Steel Architectural Sheet&Coil is extra smooth, tension leveled,hot-dipped 55%Al-ZN coated steel that is primed and coated on Dimensions: one side with Ultra-Clad full strength Hylar 5000/Kynar 500®(contains a minimum Gauge In: Slit Coil: Sheet of 70%Hylar/Kynar polyvinylidene fluoride(PVDF)resins)premium fluoropolymer 22,24,26ga 4"-48" 48"x 96",120,&144"* coating system of 1.0(±0.1)mil total dry film thickness.For additional protection a wash coat of.03-.04 mil dry film thickness is applied to the reverse side.An (10.16cm -121.92cm) (1.2m x 2.4,3.1,&3.7m) optional strippable protection film is applied for protection during fabircation and installation.Coated Metals Group Ultra-Clad PVDF Coated Galvalume®Steel Physical Properties of Fluoropolymer Coating: Architectural Sheet&Coil is for general sheet metal use in building applications and can be utilized for fascia panels,soffits,gravel stops,copings,and roofing such Property Test Method Typical as flat seam,standing seam,batten seam,and mansards. Abrasion ASTM D968 Coefficient of sand Resistance abrasion 65±10 liters METHOD OF APPLICATION 1.Install in accordance with recognized sheet metal practices. Accelerated ASTM D4587 Chalk:rating of 8 or 2. CMG Ultra-Clad can be cut,formed,and fastened using conventional hand or Weathering Condition B or ASTM better per ASTM D4214 power tools. G23, Method 1 or 2, method A(ASTM D659) 3. For best results cutting tool edges should be kept sharp,clean,properly Type EH apparatus Color:<24E Hunter units dressed,and closely aligned. or ASTM G151 for per ASTM D2244, 4. Fabrication and erection can be accomplished with strippable plastic film in 5000 hours exposure No loss of adhesion place.Film should be removed from ares of concealed or joined pieces. ASTM D4587 Chalk:rating of 8 or STORAGE AND PACKAGING: Condition B or ASTM better per ASTM D4214 1.CMG metal sheet and coil should be stored in a well ventilated,dry place where G53,Method 1 or 2, method A(ASTM D659) no moisture can contact the sheet.Moisture(from rain,snow,condensation,etc.) Type EH apparatus or Color:<24E Hunter units trapped between layers of material may cause water stains or white rust,which ASTM G154 for 5000 per ASTM D2244, can affect the service life of the material and will detract from its appearance. hours exposure No loss of adhesion 2. If outdoor storage cannot be avoided,protect the sheet and coil with a ASTM D4587, Chalk:rating of 8 or ventilated canvas or waterproof paper cover.Do not use plastic,which can cause Condition B or ASTM better per ASTM D4214 condensation.Keep the material off the ground in an inclined position with an G23,Method 1 or 2, method A(ASTM D659) insulator such as wood. Type EH appartus or Color:<24E Hunter units 3. Maximum 2,000 lbs of sheets per pallet. ASTM G151 for 2000 per ASTM D2244, hours exposure No loss of adhesion PRECAUTIONS&LIMITATIONS: 1. Protective film may degrade or become brittle with exposure to direct sunlight. *May not be available in all colors,gauges,or widths. 2. The performance of this material in the field depends substaintially on the Additional lead times may apply.Contact Coated Metals Group for additional integrity of the paint film and on the underlying zinc-aluminum coating being information intact.Therefore,this Ultra-Clad product should not be used in areas of high abrasion or where it is subject to mechanical damage. 3. Product is pre-finished material;care must be exercised during fabrication and erection to avoid surface damage. 4.Attention should be paid to good house-keeping practices. Compliance: 5.Tools must be clean and properly dressed. Kynar 500/Hylar 500 Paint Finish:AAMA 621-02 6. Avoid dragging sheets over surfaces which may scratch or mar the finish. 7. For general sheet metal use in building applications. 8.Do not use with power saws or abrasive blade. RECEIVED R03/28/2023M 03/28/2023 IUROULOINAME ASPEN ""° BUILOINO DEPARTMENT TECHNICAL INFORMATION SHEET °K( PRODUCT DATA(cont.) Tunnel Test ASTM E84 Class A coating COATED METALS GROUP UV Exposure ASTM D2244 Chalk:rating of 8 or better Kynar 500/Hylar 5000 per ASTM D4214, Pre-Finished Galvalume® Steel method A(ASTM D659) Architectural Sheet& Coil Color:<5.E Hunter units per ASTM D2244; PRODUCT DATA(cont.) no loss of adhesion Adhesion ASTM D3359 No adhesion loss Wet Adhesion ASTM D 1500 hours of water Chalk Resistance ASTM D4214 Method A Maximum Chalk rating immersion,no loss of and ASTM D659 of B adhesion,no blistering Chemical/Acid ASTM D1308 20%sulfuric acid, Pollution Resistance 18 hours No effect 10/muriatic acid Physical Properties of Base Metal: 15 minutes No effect Base Metal: AZ50 coated Galvalume steel sheet; Cyclic Salt Fog ASTM B5894 2016 hours Passess commercial weight,meeting Scribe:Rating of 8(1/8" ASTM A 792 CS Type B for Zincalum coated creepage)per ASTM D1654 steel sheets&coil procedure A Field:rating of 10 Minimum Yield: 33 to 50 KSI(227 to 310 MPa) (no blistering)per ASTM D1654 procedure B Coefficient of 06.7 x 10-6 in/in/F°(13.9m/m.K x 10-6) Thermal Expansion: Formability ASTM D522 180°bend around%" mandrel no cracking Modules of Elasticity: 29.0 x 106 x KSI(200 GPa) No adhesion loss 1-2T bend ASTM D4145 Specification: ASTM E111-04 Specular Gloss ASTM D523 25-35 at 60 degrees Measured at 60' Hardness ASTM D3363 HB-2H eagle turquoise Humidity Resistance ASTM D2247 Rating of 10;no blistering, no loss of adhesion Impact Resistance ASTM D2794 Reverse and Direct Impact no cracing,no loss of adhesion COATED METALS GROUP Salt Spray Resistance ASTM B117 5%Salt Fog 1000 hours exposure 301 Yard Dr.•Verona,WI 53593 @95'F Scribe:Rating of 7 800-784-0356•608-826-0356•FAX 608-826-4264 (1/16"creeapage)per www.cmgmetals.com ASTM D1654 procedure A Field:rating of 10 (no blistering)per ASTM D1654 procedure B RECEIVED 1103/28/2023 03/28/2023 mcoecamma ASPEN ""° BUILDING DEPARTMENT Lear ab0Ut vERsAsHIELD0 Le f peck 00° eti°n Fire-Resistant Roof Deck Protection prate Helps Protect Your Roo From Moisture While Improving Fire • , Resistance With iii& _,,,L..... L ASS A , a' — Roof Deck . - I • °I I I°in 1 tec4--- .-1-4'..4. .._...._ ._.. ............ _... :,....... ...,............_ . ..,,..........„................. . .4.,,,,..:„..., _ __,.. ..... ,.......,...„ .... L[5...... 11lt.Y WMrMe�� Quality Roof Deck Protection provides an extra layer of moisture ,�,r,.�_.,,._� protection between your roofing material and the roof deck. =``"— However, in some jurisdictions, roof assemblies are also required v, ...so."•f to be fire resistant. A Fire-Resistant Roof Deck Protection: -� h • Should provide the very best fire protection: a UL Class A rating ..,,�.W,...--I° on most homes and properties • Helps protect against dangerous flame spread and penetration into .0 t... .a.. _ the interior of the property It[ 3.5 • Upgrades UL classification of most metal roofs to a UL Class A rating ;=i� ;'•"'' • Helps provide temporary moisture resistance while the roofing system is being installed ® VersaShield®Fire-Resistant Roof Deck Protection •GOOD• /± HOUSEKEEPING is a key part of the GAF Lifetime Roofing GAF °.ea;* �.M°� System, and has even earned the prestigious U.S. Only Good Housekeeping Seal (see reverse). RECEIVED 03,2,,,o23� 03/28/2023 I..CUottr.t ASPEN " BUILDING DEPARTMENT _ N II® ■ Fire-Resistant Roof Deck Protection Property Owner's Best Choice TYPICAL APPLICATIONS FOR COMBUSTIBLE DECKS -Maximum Protection... Against fire spread and penetration. -Looks Better... Fiberglass reinforced,so it Iriorp* lies flatter for a better-looking roof(compared I to typical asphalt felts). •Peace Of Mind... Up to a = Roof covering will Lifetime ltd.warranty when Lifetime determine actual assembly* installed on Lifetime Shingle roofs.t L1D.WARRAN1YIERM 'See GAF Shingle&AccessoryLtd.Warranty for complete coverage and restrictions.The VERSASHIELD® FIRE-RESISTANT ROOF DECK PROTECTION word"Lifetime'refers to the length of coverage provided by the GAF Shingle&Accessory Ltd.Warrantyand means as long as the original individual owner(s)of a single-family PHYSICAL/PERFORMANCE PROPERTIES detached residence[or the second owners in certain circumstances]owns the property where the shingles and accessories are ins ailed.For owners/structures not meeting the Tensile above criteria,Lifetime coverage is not applicable.Lifetime Ltd.Warranty on accessories requires the use of at least three qualifying GAF accessories and the use of Lifetime Shingles. MD 60 lb./in.width Contact GAF Technical Services at 1-800-ROOF-411 or visit gaf.com for ASTM D146/D828 acceptable non-asphaltic roofing systems and limited warranty coverage. CMD 30 lbfin.width Tear Professional's Best Choice MD ASTM D1922 400grams — 'Increased Productivity... Fire-resistant slip CMD 550 grams sheet AND roof deck protection in one roll. Water Vapor Transmission •Convenient... Will upgrade the UL fire Permeance ASTM E96 3 Perms minimum classification of almost any type of roof. Liquid Water Transmission Test ASTM D4896 I Pass -Great Walkability... Slip-resistant walking surface improves traction on steep slopes. -Easier To Use... Light color provides a cooler VERSASHIELD' FIRE-RESISTANT ROOF DECK PROTECTION working surface. CLASS A RATING LAYER REQUIREMENTS •U.V.Resistant... Resists UV degradation for Wood g up to 60 days** Roofing Roof Min. 15/32" Shake/ Spaced .11010 jape Thickness Plywood Shingle Sheathing UL Listed Stone Direct to 0.013" 1 Layer N/A 1 Layer Specifications (nom.) Coated Steel deck shingle UL Classified or Direct to 0.013" 1 Layer+ N/A 1 Layer+ •3.5 squares(32.5 m2)per roll(excludes laps) Listed Steel deck shingle 30 Felt 30 Felt Any UL•42"(1.07 m)wide, 100 ft. (30.48 m)long Listed Steel lssified or shingle hBa ngleten required 0.013" 1 Layer 2 Layers 1 Layer •Approx.52.5 lb.per roll Any UL Classified or Panel of 0.015" 1 Layer N/A 1 Layer Listed Steel standing seam •Meets or exceeds ASTM D146, Any UL Classified or Panel of 0.016" 1 Layer N/A 1 Layer D226 Type II, D828, D4869 Type IV, Listed Copper standing seam D6757 T e I or T e II Any UL Classified or Shingle 0.016" 1 Layer+ 2 Layers 1 Layer+ yp yp Listed Copper 30 Felt 30 Felt ....". _� • UL Listed Any UL Classified or Panel or 0.018" 2 Layers N/A N/A — Listed Aluminum shingle --- -- •Miami-Dade County - _ Product Control Approved When installed in accordance with section 4.2.1 of GAF's ESR-2053,VersaShield® Fire-Resistant Roof Deck Protection can be used over existing wood shakes or shingles �..,......y • Florida Building Code Approved as an alternative to the covering materials specified in section 1510.4 of the IBC, -„�_ section R907.4 of the IRC,or section 1513.3 of Chapter 15 Appendix to the UBC. •ICC ESR-2053 •ICC AC-160 VERSASHIELD®FIRE-RESISTANT ROOF DECK PROTECTION �—- *Please refer to Underwriters Laboratories Certifications PACKAGING AND STORAGE Directory for actual assemblies. 3-15 **60-day UV resistance refers to standardized testing conducted i''" to ensure the product will not physically degrade when exposed 25 rolls per pallet to UV.It is NOT related to withstanding water,snow,or wind. 24 pallets per truck,single stacked,600 rolls/truck While VersaShield®Fire-Resistant Roof Deck Protection is water resistant,it is NOT waterproof.DO NOT USE VersaShield® Do NOT double stack Fire Resistant Roof Deck Protection as a temporary roof to Protect from precipitation,moisture,sunlight,and extreme temperatures while in storage protect property or possessions. ® The GAF Lifetime Roofing System pUA��TT TEFTFp has earned the prestigious Good GAF 'GOOD' Housekeeping Se al,which means that HOUSEKEEPING Good Housekeepingstandsbehind theproducts in thissystem.(Referto ecy sm..*,,OF ,09 Good HousekeepingMagazrneforits RECEIVED -k'4FFANT.....,,,la inUS.oprotectaon pollacy.Applicable visit afcom ©2015 =`:al'dL"`.#60803 F�ySAl�l�22 7� g o3,,.,,0=3 t WRC.EiIEEilVa ASPEN ""O BUILDING DEPMTMEM RESISTO •v .."...., ..„...„ i! LASTOBOND .. . ,„.... ......... ,...., pR . ••- ..., ....... „.. 0 HT-S , , . .„1,,,iv ,,, :............„ , /., -,...,. EAVE PROTECTOR I UNDERLAYMENT ���11h1N. Inil ; High performance self-adhesive underlayment for metal roofs,or as a perimeter membrane under one-ply roofing system and asphalt shingles.It is designed to withstand temperature variations from-45°C to 126° C(-49 °F to 260°F). • Excellent resistance to temperature variations • Easy Installation • UV resistant; 90-day exposure PRODUCT PURPOSE PRODUCT CHARACTERISTICS II pp ication All Waterproofing Techn SBS modified bitumen [Building Part 111.Roofing Surface-mmiTrilaminate woven polyethylene types of slope _Outside steep slope Outside low slope Underface Two parts silicone release film pe of covering 1111 Metal roofing Asphalt shingles (split back) Bitumen membrane Installation Method Self-adhesive pirate Plywood Asphaltic panel Operating tempera -45°C to 126°C(-49°F to 260°F) AMIL OSB Gypsum Maximum expos 90 days PACKAGING Width Length Thickness Gross Area Cod• Quantity (per pallet cm in m ft mm mils m2 ft2 10108(With box) 91 36 20 65.6 1 40 18 195 25 10009(Without box) 91 36 20 65.6 1 40 18 195 36 PROPERTIES 'roperties STANDARDS LASTOBOND PRO HT-S Thickness - 1.0 mm(40 mils) Roll Weight - 20 kg(44 lbs) Breaking Strength,MD/XD ASTM D1970 11/12 kN/m(63/68 lbf/in) Elongation at break,MD/XD ASTM D1970 30/20% Tear Resistance,MD/XD ASTM D1970 375/400 N(84/90 lbf) Static Puncture ASTM D5602 400 N(90 lbf) Adhesion to plywood,4,5°C(40°F) ASTM D1970 1.6 kgf/30.5 c,(3.5 lbf/in) Adhesion to plywood,24°C(75°F) ASTM D1970 25 kgf/30.5 cm(55 lbf/in) Low Temperature Flexibility ASTM D1970 Pass at-30°C(-22°F) Water vapour permeance ASTM E96(PROCEDURE B) <2.1 ng/Pa.s.m2(<0.037 perm) Nail Sealability ASTM D1970 Pass For CCMC product evaluation in compliance with CSA A123.22-08,see CCMC Evaluation Listing#13570-L. (All values are nominal) RECEIVED k°3 2_02311 03/28/2023 IURLAOicarNma ASPEN ""° BUILDING DEPARTMENT RESISTO LASTOBOND PRO HT-S INSTALLATION Storage Rolls should be stored upright,tape side up.If the products are stored outdoors,cover them with an opaque protective cover after removing the delivery packaging. I Can withstand freezing but must be reactivated to at least 10°C(50°F) before installation. Minimum Application 10°C(50°F) Temperature Lomplementary Prod EXTERIOR PRIMER OR H2O PRIMER ols Required �. Knife Smoothing roller a, Tape measure FSurface Preparation The substrate must be clean,dry and free of dust,grease or other contaminants. (Installation Prerequisite The use of EXTERIOR PRIMER or H2O PRIMER is not required on most surfaces when the membrane is covered within 24 hours of installation.However,primer is mandatory when membrane is used as underlayment in a RESISTO single-ply roofing system. Ration 1. If conditions require,prepare the substrate with EXTERIOR PRIMER or H2O PRIMER. 2. Position the membrane parallel to the roof edge while leaving about 8 cm(3.2 in) at the front where the gutter will be installed. 3. Fold back on itself,by half of its width,or 50 cm(20 in)over the whole length already positioned.It is recommended to kneel on the unfolded portion of the membrane to keep it in place during this operation. 4. Remove the protective film from the folded section while placing the membrane on the support.The self- adhesive portion then adheres to the support. 5. Then take the other side of the membrane and repeat the previous two steps. 6. Immediately apply pressure on the membrane using a heavy metal roller or a hard rubber roller to ensure adhesion between the support and the membrane and avoid forming bulges,folds or gaps. Note: The transverse overlap should be 150 mm(6 in)and longitudinal overlap should be 75 mm(3 in). Refer to ROOF SYSTEM INSTALLATION for waterproofing membrane installation to roof details and upstands. LItRecommendations/ is not recommended to use a product containing bitumen directly on softwood boards or flexible polyvinyl imitations 1 chloride. For UL product evaluation,see UL Evaluation ER-21824-01 cz MIAMI•DADE COUNSYMS UA7SEMEENVIRONNEMET 1SJ1!! APPROVED I 0 I014 EU1EXA FLORIDA BUILDING CODE �� QUALITY SYSTEM ENVIRONMENT SYSTEM) resisto.ca I resisto.us 1Ewa RECEIVED 3,2"20230 03/28/2023 10,100.YYllI. ASPEN "•O BUILDING DEPARTMENT Product Data Sheet MULE-HIDE M EMULE-HIDE POLY ISO1 TM ROOF INSULATION PRODUCTS '116.41 PRODUCT DESCRIPTION The Mule-Hide Poly ISO 1 TM polyisocyanurate insulation (flat or tapered) is a closed-cell polyisocyanurate foam core laminated to (non-asphaltic) glass fiber reinforced felt facers. The Mule-Hide Poly ISO 1 is compatible with all Mule- Hide membranes and accessories.Available in 20 psi and 25 psi. BASIC USES The Mule-Hide Poly ISO 1 TM insulation board may be used for ballasted, mechanically attached and fully adhered single- ply roofing systems. The Poly ISO 1 TM insulation board may be installed over approved decks and substrates on new construction, tearoffs, and recover (retrofit) projects. The Poly ISO 1 TM insulation board may be used in UL Class A and FM Class 1 assemblies. BENEFITS & SUPPLEMENTAL STATEMENTS • Approved for direct application to steel decks • Mule-Hide Poly ISO 1 TM is manufactured with NexGen Chemistry: Contains no CFCs, HCFCs, is Zero ODP, EPA Compliant and has virtually no GWP • Available as 4'x 4' or 4' x 8' panels in Grade 2 (20 psi)or Grade 3 (25 psi) • Thicknesses range from 1"to 4.5" TYPICAL PHYSICAL PROPERTIES Property I Test Method Typical Results Dimensional Stability ASTM D-2126 2% Linear Change (7 days) Compressive Strength ASTM D-1621 20 PSI (Grade 2)25 PSI (Grade3) Water Absorption ASTM D-209 Less than 1% By Volume Moisture Vapor Transmission ASTM E-96 Less than One(1)Perm Service Temperature --- -100°F to 250°F Max Flame Spread (foam core) ASTM E 84 < 75** Smoke Development ASTM E 84 <450** *The physical properties above are presented as typical average values as determined by accepted ASTM test methods and are subject to change. All information can be confirmed by contacting Mule- Hide Products. **The numerical ratings are determined by ASTM Test Method E-84 are not intended to reflect hazards presented by this or any other material under actual fire conditions. A flame spread index of 75 or less and smoke development of 450 or less meet code requirements regarding flame spread and smoke development for foam plastic roof insulation. However,the codes exempt foam plastic insulation when used in roof deck constructions that comply as an assembly with FM 4450 or UL 1256(see IBC,NBC, UBC and SBS Sections on Foam Plastic Insulation(Chapter 26). Smoke development does not apply to roofing LTTR ASTM C1289-11 PolyISO TM Recycle Content Value (revised Jan-2014) 20 2 layers of 1.8" Poly ISO Between 16% and 43 % by weight, depending upon 25 2 layers of 2.2" Poly ISO thickness (55% post consumer and 45% post industrial). 30 2 layers of 2.6" Poly ISO Refer to Mule-Hide LEED memo. 35 2 layers of 3.1" Poly ISO 40 2 layers of 3.5" Poly ISO Revised: March-2017 PDS 09-6210 Page 1 of 3 -6 � RECEIVED it o3i2,.3 03/28/2023 PACas°- ASPEN '" BUILDING DEPARTMENT Product Data Sheet MULE-HIDE POLY ISO1 TM ROOF INSULATION mmEmmEmmEmmEmmEmm TYPICAL PHYSICAL PROPERTIES (Continued) Poly ISO I TM Nominal Thickness** (mm) LTTR R-Value C-Value Metal Deck Max. Flute (Inches) (revised Jan-2014) 1.0 25 5.7 .175 2% 1.5 38 8.6 .116 4% 1.8 46 10.3 .097 4% 2.0 51 11.4 _ .088 _ 4% 2.5 64 14.4 _ .069 _ 4% 2.6 66 15.0 .067 4% 3.0 76 17.4 .057 4% 3.5 89 20.5 .049 4% 3.8 97 22.3 _ .045 _ 4% 4.0 102 23.6 .042 4% 4.3 109 25.5 .039 4% 4.5 114 26.8 .037 4% *Long Term Thermal Resistance Values are based on ASTM C1289(revised Jan-2014)and CAN/ULC S770 which provides for a 15-year time weighted average. **Other thicknesses available upon special request. SUPPLIMENTAL INFORMATION PROFILES • 2.5" 6.5" 1 .0" 2.0" 3.0•' 1 .5" 3.5" • 0.5" 4.5" 0.5" 1 .5" 2.5" 3.5" 0.5" 2.5" 4.5" • O 01 02 AA A B C AA1 Al X Y X1 Y1 • • FILL BELOW FILL BELOW FILL BELOW • OQ • E • Q : /Z 51-OPE Q 2.o SLOPES `...a A *1/4.. Y • • • O 2.0" ISO 2.0" ISO y 2.0" ISO • • • • • PACKAGING Factory applied packaging is only intended for protection during transit.When stored outside or at the job site, the insulation must be stored at least 4"above ground level and completely covered with a weatherproof covering such as a tarpaulin. Warning -Do Not Leave Exposed: This product will burn if exposed to an ignition source of sufficient heat and intensity, or an open flame. CODE APPROVALS/COMPLIANCE Poly ISO 1 TM complies with the requirements of the following specifications, test and code requirements when properly installed. * Federal Specification HH-I-1972/GEN and HH-I-1972/2, Class 1 *ASTM C 1289-05a, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) * FM Standard 4450/4470 Approval, Class 1 * UL Standard 1256 Classification Page 2 of 3 PDS 09-6210 Revised March-2017 u l RECEIVED R.o3i28/2o21 03/28/2023 ASPEN '••` BUIL01NGDEPSPTMEM Product Data Sheet MULE-HIDE POLY ISO1 TM ROOF INSULATION CODE APPROVALS/COMPLIANCE (continued) * UL Standard 790 Classification * UL Standard 263 Fire Resistance Classification INSTALLATION INSTRUCTIONS Ballasted Single-Ply Membrane Systems - Mule-Hide Poly ISO 1 TM does not require attachment to the deck in this system.All boards must be tightly fitted together to prevent movement, separation or damage during the installation of the membrane system.All gaps greater than 1/4" must be filled.After the membrane is installed, sufficient amounts of ballast must be applied to prevent membrane and insulation movement. Refer to the Mule- Hide Manual and FM Loss Prevention Data Sheet 1-29 for information regarding ballasting guidelines. Mechanically Attached Single-Ply Membrane Systems-Mule-Hide Poly ISO 1 TM should be attached with Mule-Hide fasteners and insulation plates (or FM Approved fasteners) using a minimum of 4 fasteners per 4'x 4' board (1 fastener per 4 square feet)and a minimum of 6 fasteners per 4'x 8' board (1 fastener per 5.33 square feet). Refer to the Mule-Hide Manual for proper fastener placement. Fully Adhered Single-Ply Membrane Systems-Mule-Hide Poly ISO 1 TM should be installed with the perforated side down. Insulation attachment will vary depending upon insulation thickness and job requirements. If the top layer is less than 2"thick, install a minimum of 8 fasteners per 4'x 4' board (1 fastener per 2 square feet)and a minimum of 16 fasteners per 4'x 8' board (1 fastener per 2 square feet). If the top layer is 2"thick or thicker, install 4 fasteners per 4'x 4' or 8 fasteners per 4'x 8' insulation board. Refer to the Mule-Hide Manual for proper fastener density and placement. Additional fastening may be required for certain job conditions. In some instances hot steep asphalt or insulation adhesive may be used to attach the Mule-Hide Poly ISO 1❑❑to approved concrete decks. Only 4'x 4' boards may be used. Contact Mule-Hide's Technical Department for specific requirements and procedures. PROTECTION & SAFETY Mule-Hide maintains Safety Data Sheets on all of its products. Safety Data Sheets contain health and safety information for your development of appropriate product handling procedures to protect your employees and customers. Mule-Hide's Safety Data Sheets should be read and understood by all of your supervisory personnel and employees before using Mule-Hide products in your facilities. ADDITIONAL INFORMATION The information given on this PDS is subject to change without notice. Always check the Mule-Hide website at www.mulehide.com for the latest information, changes and updates or contact Mule-Hide Products Company at 800-786-1492. DISCLAIMER The statements provided concerning the material shown are intended as a guide for material usage and are believed to be true and accurate at the time of printing. No statement made by anyone may supersede this information,except when done in writing by Mule-Hide Products Co., Inc. Since the manner of use is beyond our control, Mule-Hide does not authorize anyone to make any warranty of merchantability or fitness for any particular purpose or any other warranty,guarantee or representation,expressed or implied,concerning this material. Buyer and user accept the product under these conditions and assume the risk of any failure,any injury person or property(including that of the user),loss or liability resulting from the handling,storage or use of the product whether or not it is handled,stored or used in accordance with the directions or specifications. Mule-Hide must be notified in writing of any claims and be given the Revised: March-2017 PDS 09-6210 Page 3 of 3 ,''f RECEIVED 03/2e/2023 J 03/28/2023 OPOCC.... ASPEN ""O BUILDING DEPARTMENT