Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.630 W Hopkins Ave.0052-2020-BRES (9)
REScheck Software Version 4.6.5 Compliance Certificate Project 630 W. Hopkins Remodel Energy Code: 2015 IECC Location: Aspen, Colorado g lEV Construction Type: Single-family n12/03/2020 J Project Type: Alteration bonniem Climate Zone: 7 (9922 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 630 W Hopkins Total UA = 688. Nate Radomski Aspen, CO 81611 Using proposed Architectural Engineering Consultants assembly values. 40801 HWY-6 Compared to code Avon, CO 81620 nathan@aec-vail.com reference this passes by %7.1 Compliance: Passes using prescriptive requirements for alteration projects Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter East wall: Wood Frame, 24" o .c. 1,101 32.0 0.0 0.045 43 Window 1: Metal Frame with Thermal Break:Triple Pane with Low-E 57 0.320 18 Door 1: Glass 91 0.320 29 North wall: Wood Frame, 24" o .c. 990 32.0 0.0 0.045 29 Window 2: Metal Frame with Thermal Break:Triple Pane with Low-E 206 0.320 66 Door 2: Glass 140 0.320 45 South Wall: Wood Frame, 24" o .c. 999 32.0 0.0 0.045 14 Window 3: Metal Frame:Triple Pane with Low-E 227 0.320 73 Door 3: Glass 467 0.320 149 West Wall: Wood Frame, 24" o .c. 1,159 32.0 0.0 0.045 44 Window 4: Metal Frame with Thermal Break:Triple Pane with Low-E 175 0.320 56 R-1 Flat roof: Flat Ceiling or Scissor Truss 223 39.0 10.0 0.023 5 R-2 Main Gable: Cathedral Ceiling 1,877 51.0 18.0 0.015 28 R-3 Main level roof: Cathedral Ceiling 549 51.0 0.0 0.021 12 Basement Wall 1: Solid Concrete or Masonry 1,877 0.0 15.0 0.041 77 Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' Project Title: 630 W. Hopkins Remodel Report date: 10/16/20 Data filename: P:\Current Projects\20007.00 - Ski Haus Remodel at 630 W Hopkins\Calculations\20007- Page 1 of 2 630 W Hopkins rescheck- updated.rck Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Nate Radomski - Mechanical engineer , — -----` 10/16/20 Name-Title Signature Date Project Title: 630 W. Hopkins Remodel Report date: 10/16/20 Data filename: P:\Current Projects\20007.00 - Ski Haus Remodel at 630 W Hopkins\Calculations\20007- Page 2 of 2 630 W Hopkins rescheck- updated.rck REScheck Software Version 4.6.5 Compliance Certificate Project 630 W. Hopkins Remodel Energy Code: 2015 IECC Location: Aspen, Colorado Construction Type: Single-family Project Type: Alteration Climate Zone: 7 (9922 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 630 W Hopkins Nate Radomski Aspen, CO 81611 Architectural Engineering Total UA = 642 Consultants Using code R-values 40801 HWY-6 and 0.28 u-value. Avon, 81620 nathan©aec-vail.com Compliance: Passes using prescriptive requirements for alteration projects Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter East wall: Wood Frame, 24" o .c. 1,101 20.0 5.0 0.043 41 Window 1: Metal Frame with Thermal Break:Triple Pane with Low-E 57 0.280 16 Door 1: Glass 91 0.280 25 North wall: Wood Frame, 24" o .c. 990 20.0 5.0 0.043 28 Window 2: Metal Frame with Thermal Break:Triple Pane with Low-E 206 0.280 58 Door 2: Glass 140 0.280 39 South Wall: Wood Frame, 24" o .c. 999 20.0 5.0 0.043 13 Window 3: Metal Frame:Triple Pane with Low-E 227 0.280 64 Door 3: Glass 467 0.280 131 West Wall: Wood Frame, 24" o .c. 1,159 20.0 5.0 0.043 42 Window 4: Metal Frame with Thermal Break:Triple Pane with Low-E 175 0.280 49 R-1 Flat roof: Flat Ceiling or Scissor Truss 223 49.0 0.0 0.026 6 R-2 Main Gable: Cathedral Ceiling 1,877 49.0 0.0 0.022 41 R-3 Main level roof: Cathedral Ceiling 549 49.0 0.0 0.022 12 Basement Wall 1: Solid Concrete or Masonry 1,877 19.0 0.0 0.041 77 Wall height: 9.0' Depth below grade: 9.0' Insulation depth: 9.0' Project Title: 630 W. Hopkins Remodel Report date: 10/19/20 Data filename: P:\Current Projects\20007.00 - Ski Haus Remodel at 630 W Hopkins\Calculations\20007- Page 1 of 2 630 W Hopkins rescheck- code reference.rck