Loading...
HomeMy WebLinkAboutFile Documents.320 N 7th St.0111-2021-BRES (12) Engineering 1 - 320 N 7th St - 0111 -2021 -BRES 90.Civil Plans.20210727.pdf(5) 4r Page: 1 i �, �� Author:wyatty Portion of snowmelted driveway ' j File Name: 90.Civil Plans.20210727.pdf and curb wall in ROW will need +! a permanent encroachment g `0 s. license. r �, =.e v SE:An application for a permanent ,�- encroachment license will be '�. submitted to the City during the ,/. 0y,, ' sys' Certificate of Occupancy process. Page: 1 Author:wyatty This property is outside of the j File Name: 90.Civil Plans.20210727.pdf sidewalk and curb and gutter .,_,E deferred zones. SE:Sopris Engineering and City of Aspen representatives met onsite 05/11/2022 to discuss sidewalk and curb deferral. Sidewalk and curb and gutter will — It was mutually agreed upon that the building permit resubmittal can need to be installed along the —occur without including the sidewalk curb and gutter improvements. extent of the property line bordering the ROW along N 7th If the CityEngineering Department determines that the sidewalk with ------- 9� 9 p St to bring this property into curb and gutter is required,SE can provide design and incorporate into compliance with all capital plans and issue as Additional Information for review and approval. improvements. Page: 1 Call out that this section of Author:wyatty gravel will also be removed and l _,_____ --- --- File Name: 90.Civil Plans.20210727.pdf - , re-vegetated. ,,== ' SE: Noted,and the plans have been 1s 41. updated accordingly. II Page: 2 k % Existing water service line size o , - Author:wyatty t: " li �y' = File Name: 90.Civil Plans.20210727.pdf and material needs to be called t r .� Ai '111 1— out. : bbbt�� SE: Fire flow calculations are not provided as there is ii �g .L not an existing sprinkler system and one is not Fire flow calculations need to be proposed with the remodel improvements. In addition, { provided to confirm capacity. the proposed interior remodel will not increase fixture SE:Existingwater service size and .•.i7 counts. Therefore,the existing water service is ..v...::. ,,,,,/ material added to plans. Information ; 1-. I adequate to continue to serve the subject property. '�11 provided to Sopris Engineering by City of Aspen Engineering Department. �� \1j//1/ Page:4 Variance request letter needs to j' 9 Author:wyatty 2 ,, File Name: 90.Civil Plans.20210727.pdf follow guidelines set forth in the COA municipal code Title 29 } Sec. 29.01.070-Variances. , The engineering standard that is r �arr being varied from needs to be lit�' : Il clearly defined. Ili+ .;I SE:A variance request letter was included with the original building permit application as part of the drainag- -.•• -•• That variance requesi r-` ::I ' D as part of this resubm .- •- -- standalone document. 05/23/2022 ASPEN BUILDING DEPARTMENT