Loading...
HomeMy WebLinkAboutFile Documents.630 W Hopkins Ave.0052-2020-BRES (30) Residential Design Standards ;4 ; Administrative Compliance Review Staff Checklist - Single Family and Duplex uTYQF ASPEN Address:630 W. Hopkins Parcel ID:2735-124-48-520 Digitally signed by Zone District/PD:R-6 Approved: Garrett Larimer Joseph Spears Approved: Garrett Larimer DN:CN=Garrett Larimer Representative: A roved laps/elevations attached Date:2020.02.10 Email:Joseph@s2architects.com ( pP P ) 16:26:47-07'00' Phone:970-544-4856 Disclaimer: This application is only valid for the attached design.If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Standard Complies N/A Sheet#(s)/Notes Compliance Com r Measurement of front most wall to rear wall is unchanged. B.1.Articulation of Building Mass (Non-flexible) r No change in building orientation. B.2.Building Orientation (Flexible) v No change proposed. B.3.Build-to Requirement (Flexible) B.4.One StoryElement Projecting one story element meets minimum depth and width (Flexible) ✓ requirements. Is less than one story. and is open on three sides. C.1.Garage Access Garage accessed from alley, no change proposed. (Non-flexible) ✓ C.2.Garagery (Non- Placement Garage access from alley. (Non-flexible) C.3.Garage Dimensions I Garage measures 16'2", less than the 24' max allowed. RECEIVED (Flexible) 06/30/2020 2 ASPEN BUILDING DEPARTMENT p"lel"sbnes", Os.Lnner °'rretWiner u r .ret` Residential Design Standards OOT7 Administrative Compliance Review Staff Checklist THE CITY OF ASPEN Disclaimer: This application is only valid for the attached design.If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Complian FA I Sheet#(s)/Notes C.4.Garage Door Design I A one foot separating element is used. (Flexible) ✓ D.1.Entry Connection A street oriented entrance is proposed. (Non-flexible) D2.Door Height All street facing doors shown at less than 8'. (Flexible) ✓ D.3.EntryPorch (Flexible) Entry porch shown at 9'7". ✓ E.1.Principle Window Principal window shown above front entry door that meets the minimum (Flexible) ✓ size requirements. E.2.windo Placement All street facing windows measure less than 10' and no windows span (Flexible) ✓ two stories. E.3.Nonorthogonal Window Limit A large non orthogonal window is proposed in the gable end on the street (Flexible) facing facade. Window is broken up by mullions and meets the requirements of this section. E.4.Lightwell/Stairwell Location No lightwell or stairwells are proposed between the front most facade of (Flexible) the structure and the street. E.5.Materials Materials are used true to their characteristics and consists4U9Q - ,leiVE (Flexible) sides. Kt' D 06/30/2020 Pa<<< 2 ()t 2 ASPEN BUILDING DEPARTMENT