Asbestos Sampling Report Aspen Courthouse
Date:03/05/2024 530 E. Main St.
U
v; Aspen, CO 81611
+1 Date of Inspection: 03/04/2024
3
c Client: Element Environmental Project#:
u City of Aspen 030424 Main
jjC City of Aspen
E
aJ
Client Job Name
Meeting Room Wall
Attn:
Jodie Grady TABLE OF CONTENTS
Z
O 1.0 -Scope of Work
2.0 -Sampling Requirements
O 3.0 -Sampling Methodology
v) Building Inspector: 4.0 - Laboratory
5.0 -Suspect Materials Sampled
Scott Roahrig 6.0 -Table of Results
H 7.0 - Description of Sampling Area
CDPHE#29245 8.0 -Conclusion
9.0 - Lab Report
= Joshua Johnson 10.0 - Certificates
CDPHE #18401
OAsbestos Samples Analyzed: 3
J Positive Asbestos Samples: 0
��
O RE`s.�1 ED
N
Q 03/15/2024
ASPEN
BUILDING DEPARTMENT
2
1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel.
Element Environmental conducted a visible inspection for visible materials that would
be impacted during the remodel. This inspection was limited to the areas found in the
Description of the Sampling Area 7.0. Although sampling is destructive in nature, this
was a non-invasive inspection. It was of materials that were accessible. If other suspect
materials become visible/apparent during demolition or construction activities, work in
that area should be halted and more sampling/testing must take place, per Colorado
regulations. Any suspect materials that were not tested are to be assumed to contain
asbestos.
2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with
Colorado State Requirements. The minimum number of samples per homogenous areas
are as follows:
-Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples
1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples
>5,000 sq.ft. Minimum of 7 samples
-Miscellaneous materials- Minimum of 2 samples
2.3-Thermal Systems Insulation(TSI)- Minimum of 3 samples
3.0- The purpose of the inspection is to identify materials that are homogenous. A
homogeneous area is defined as one which shares suspect material, texture, color,
location, and/or apparent time of construction. The materials are touched to determine
friability. Friable ACM is material that can be crushed or reduced to powder by hand
pressure. The friable materials are segregated into separate homogenous areas. The size
of the sampling area is determined. Samples are taken according to a random numerical
sequence of the subareas, following guidelines per the EPA Pink Book: Asbestos in
Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
4.0- Scott Roahrig, a Colorado Department of Public Health & Environment certified building
inspector, certification number: 29245, performed the inspection. The findings were
reviewed by Josh Johnson, a Colorado Department of Public Health & Environment
certified building inspector, certification number: 18401. Samples taken were sent to
CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light
Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be
trace, or<1% asbestos, is considered to be ACM material. This material would still be a
regulated material by CDPHE. The sample must have an additional "point count"
performed to be considered less than 1% and not be regulated by the CDPHE. The lab's
documents with analyses and findings are found below. RECEIVED
e e m en - 189 county rd 135 gLenwood springs,co 81601 970.2743139 2 4
,vww.elementconsutts.com
ENVIRONMENTAL INC
Project#-City of Aspen 030424 Main LEAD ASBESTOS I T
� IN; "Vi-MENT
5.0- SUSPECT MATERIALS SAMPLES
• Drywall
• Tape
• Joint Compound
• Texture
6.0- TABLE OF RESULTS
HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF
AREA OF SQ.FT.* ASBESTOS FOUND
SAMPLES
(A) Skip Trowel Texture on wall Surfacing 3 —50 sq.ft. Friable Non-ACM No Asbestos Detected
between BOCC meeting room
and Roaring Fork room
Key:
ACM Assessment Categories:
1-Damaged or significantly damaged Thermal Systems Insulation 7-Friable ACM with low potential for damage
(TSI)ACM Other-ACM not classified in the above Assessment Categories
2-Damaged friable surfacing ACM N/A-Not Applicable
4-Damaged or significantly damaged friable Miscellaneous ACM
5-ACM with potential for damage *Square footage is estimated and not for bidding purposes
6-ACM with potential for significant damage
7.0- DESCRIPTION OF SAMPLING AREA
• The Skip Trowel Texture on wall between BOCC meeting room and Roaring Fork meeting room
to install a door
RECEIVED
03/15/2024
ASPEN
BUILDING DEPARTMENT
4
Sampling Locations
N A
I i + ' ' , f j �;-
1
41 o t�
A3le dIO
A2�
I I i i
NTS
8.0- CONCLUSION:
No asbestos was detected in any of the samples taken.
Sincerely,
Scott Roahrig
e e m e n t 18.3 county rd 135 glenwood springs,co 81€" .274: 3 i ED
www.elementconsults.com
Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0
� ��°%���24
ASPEN
BUILDING DEPARTMENT
5
9.0- LAB REPORT
tiff• eurofins
CEI
ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Element Environmental LLC
CLIENT PROJECT: City of Aspen 030424 Main
LAB CODE: B244420
TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORT DATE: 03/05/24
TOTAL SAMPLES ANALYZED: 3
#SAMPLES>1%ASBESTOS:
730 SE Maynard Road •Cary, NC 27511 •919.481.1413
e e m e n t 189 county rd 135 gLenwood springs,co 81€„ .274::3 i ED
,www.elementconsults.com
Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAM 0
��3/��D%��o 2 4
ASPEN
BUILDING DEPARTMENT
6
eurofins Asbestos Report Summary
ti By: POLARIZING LIGHT MICROSCOPY
CEI
PROJECT: City of Aspen 030424 Main LAB CODE: B244420
METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
ASBESTOS
Client ID Layer Lab ID Color Sample Description
530 Al B244420.01 Gray,White Skip Trowel Texture None Detected
530 A2 B244420.02 Gray,White Skip Trowel Texture None Detected
530 A3 B244420.03 Gray,White Skip Trowel Texture None Detected
730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 1
e e m e n t 18g county rd 135 glenwood springs,co 81€" .274:13 ID)
www.elementconsults.com �n
Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0
��3/y�D%��o24
ASPEN
BUILDING DEPARTMENT
7
.:.• eurofins ASBESTOS BULK ANALYSIS
ti• By: POLARIZING LIGHT MICROSCOPY
CEI
Client: Element Environmental LLC Lab Code: B244420
2314 Stone Creek Court Date Received: 03-05-24
Grand Junction, CO 81507 Date Analyzed: 03-05-24
Date Reported: 03-05-24
Project: City of Aspen 030424 Main
ASBESTOS BULK PLM, EPA 600 METHOD
Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS
Lab ID Description Attributes Fibrous Non-Fibrous
530 Al Skip Trowel Texture Heterogeneous <1% Cellulose 20% Paint None Detected
B244420.01 Gray,White 50% Binder
Non-fibrous 30% Calc Carb
Bound
530 A2 Skip Trowel Texture Heterogeneous <1% Cellulose 20% Paint None Detected
B244420.02 Gray,White 50% Binder
Non-fibrous 30% Calc Carb
Bound
530 A3 Skip Trowel Texture Heterogeneous <1% Cellulose 20% Paint None Detected
B244420.03 Gray,White 50% Binder
Non-fibrous 30% Calc Carb
Bound
730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 2
e e m e n t 189 county rd 135 glen,wood springs,co 81€�^ .27q: 3
www.elementconsuLts.com
Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAM tisto7To
ASPEN
BUILDING DEPARTMENT
8
eurofins
CEI
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite
Non-Trem = Non-Asbestiform Tremolite
Calc Carb =Calcium Carbonate
METHOD: EPA 600/R93/116 and EPA 600/M4-82/020
REPORTING LIMIT: <1%by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points
REGULATORY LIMIT: >1%by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as
vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that
all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission
Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is
not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on
inquest.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full,
without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding
the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in
acceptable condition unless otherwise noted. This report may not be used by the client to claim
product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: /( APPROVED BY: 44",.
Nicholas Moore Tianbao Bai,Ph.D.,CIH
Laboratory Director
NVLA
TESTING
NVLAP LAB CODE 101768-0
730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 2 of 2
e e m en 189 county rd 135 glenwood springs,co 81€„ 274 13 I i
www.elementconsults.com I.•�w
Project#-City of Aspen 030424 Main ENVIRONMENTAL NE
LEAD ASBESTOS HAZ 0
ASPEN
BUILDING DEPARTMENT
9
ASBESTOS
SAMPLING FORM
CE .LABS
COMPANY CONTACT INFORMATION
Company:Element Environmental Job Contact:Josh Johnson
Project Name:C.0 01,qQn 030 I t'4 M01/1
Project ID#: Tel:970-274-3139
SAMPLE ID# _ DESCRIPTION/LOCATION _ TEST -- - -
Si AI ))up re I NCI PLM I ITEM
AL " �• 1 I PLM E]TEM
PLM ( I TEM
PLM I ITEM
I I PLM I ITEM
I I PLM TEM
I I PLM 1 ITEM
n PLM 1 ITEM
I I PLM I ITEM
I PLM I ITEM
r� PLM I ITEM
PLM E]TEM
r� PLM I ITEM
l I PLM ET TEM
I I PLM I ITEM
J PLM I-1TEM
�-1 PLM I ITEM
I PLM I I TEM
I PLM I I TEM
I I PLM ITEM
I I PLM I—I TEM
I I PLM I I TEM
PLM f I TEM
PLM I ITEM
I J PLM I ITEM
I I PLM I ITEM
I I PLM [1 TEM
I I PLM [—ITEM
Page of I
VERSION CCOC.0215.2/2.LD
Customer COC Page 2
e e m e n t 18g county rd 135 glenwood springs,co 81€" .274
www.elementconsults.com LLss�i 66JJ
Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0
��3/��D%��o24
ASPEN
BUILDING DEPARTMENT
10
10.0- CERTIFICATES
,,:„.....,,_, ,a,.
o Colorado Department � i4 I ,{ i.
>\ 5.- of Public Health b tr, k' Colorado�!Publ
ic t
6-- (.p and Environment !�N x ' (0 d Environment
7sr a,�
r' • ASBESTOS a, 7 ASBESTOS
�„ CERTIFICATION* r= t CERTIFICATION*
�y, Ibis certifies that u; -, l his cenities that
I� .f ui 1" 'a
.'r, » Joshua Jay Johnson a 4 , Scott Roahrig
i.
Certification No.:18401 ("`_ -Q; Certification No.:29245 r '
-I has met the requirements of 25 7 507,C.R.S.and Air Quality Control it h t the requirements of''S 7 507,('.R.S d 1 Quality Control '
e 't Commt.Sinn Regulation No 8,i'a I B,and h by n 0ed by the C mmfss on Regulation No 8,Part B.and hereby certified by the S
`-�' (u. state fit C olorado III the followingdisci line. t
liggi state of Colorado m the follow fig disctpltne r P
K ' I:' Building Inspector* 4 T Building Inspector* -
Z. Issued: August 28,2023 issued: September 22,2023i
'�. m f ., , -- Emmet, September 22.2024
yra '!Expires: August 31,2024 _- �`
ff- ' e ,,, „its',, :R , „:��.:;,�. A 7_ ''
ex- n� ,. to k l ..;M:.M.,rw. sets - 4"i
a . } m a a a
d M!: to 1
• f-
t eN,♦" tff WIc\ liffi.'1V }4W qn V .a° ' a "��r„ J . � : ' ' .4 . JIB i'i ,7'Z h ..,w:..,: .„,,,,.e.; +�� . !`y=. 4f+ �,s.... k•v
•
c,,,,,,,,,,....i.):-...„
Colorado Department
of Public Health
and Environment
ASBESTOS CONSULTING FIRM
This certifies that
Element Environmental,Inc.
Registration No.:ACF-21640
has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control
Commission Regulation No.8.Pan B.and is hereby authorized to perform asbestos consulting
arts,sties as required under Regulation No 8,Part B.in the state of Colorado.
I.,ucd: human" '0'i
3spo,.. lams n 31,,2025
d'ir .,,,,_
e e m e n t18g county rd 135 glenwood springs,co 81€ 27q 3 ) r)
www.elementconsults.comEID
Project#-City of Aspen 030424 Main ENVIRONMENTAL LEAD ASBESTOS HAZ tt /yst°% 0� o24
ASPEN
BUILDING DEPARTMENT