Loading...
HomeMy WebLinkAboutFile Documents.530 E Main St.0009-2024-BCOM (3) e e rn e n t ENVIRONMENTAL INC PO Box 2043 Glenwood Springs,CO 81602 josh@elementconsults.com (970) 274-3139 Property Address Asbestos Sampling Report Aspen Courthouse Date:03/05/2024 530 E. Main St. U v; Aspen, CO 81611 +1 Date of Inspection: 03/04/2024 3 c Client: Element Environmental Project#: u City of Aspen 030424 Main jjC City of Aspen E aJ Client Job Name Meeting Room Wall Attn: Jodie Grady TABLE OF CONTENTS Z O 1.0 -Scope of Work 2.0 -Sampling Requirements O 3.0 -Sampling Methodology v) Building Inspector: 4.0 - Laboratory 5.0 -Suspect Materials Sampled Scott Roahrig 6.0 -Table of Results H 7.0 - Description of Sampling Area CDPHE#29245 8.0 -Conclusion 9.0 - Lab Report = Joshua Johnson 10.0 - Certificates CDPHE #18401 OAsbestos Samples Analyzed: 3 J Positive Asbestos Samples: 0 �� O RE`s.�1 ED N Q 03/15/2024 ASPEN BUILDING DEPARTMENT 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: -Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.-5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples -Miscellaneous materials- Minimum of 2 samples 2.3-Thermal Systems Insulation(TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The friable materials are segregated into separate homogenous areas. The size of the sampling area is determined. Samples are taken according to a random numerical sequence of the subareas, following guidelines per the EPA Pink Book: Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials. 4.0- Scott Roahrig, a Colorado Department of Public Health & Environment certified building inspector, certification number: 29245, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or<1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional "point count" performed to be considered less than 1% and not be regulated by the CDPHE. The lab's documents with analyses and findings are found below. RECEIVED e e m en - 189 county rd 135 gLenwood springs,co 81601 970.2743139 2 4 ,vww.elementconsutts.com ENVIRONMENTAL INC Project#-City of Aspen 030424 Main LEAD ASBESTOS I T � IN; "Vi-MENT 5.0- SUSPECT MATERIALS SAMPLES • Drywall • Tape • Joint Compound • Texture 6.0- TABLE OF RESULTS HOMOGENOUS DESCRIPTION OF AREA ACM CATEGORY NUMBER APPROXIMATE ACM ASSESSMENT CATEGORIES %AND TYPE OF AREA OF SQ.FT.* ASBESTOS FOUND SAMPLES (A) Skip Trowel Texture on wall Surfacing 3 —50 sq.ft. Friable Non-ACM No Asbestos Detected between BOCC meeting room and Roaring Fork room Key: ACM Assessment Categories: 1-Damaged or significantly damaged Thermal Systems Insulation 7-Friable ACM with low potential for damage (TSI)ACM Other-ACM not classified in the above Assessment Categories 2-Damaged friable surfacing ACM N/A-Not Applicable 4-Damaged or significantly damaged friable Miscellaneous ACM 5-ACM with potential for damage *Square footage is estimated and not for bidding purposes 6-ACM with potential for significant damage 7.0- DESCRIPTION OF SAMPLING AREA • The Skip Trowel Texture on wall between BOCC meeting room and Roaring Fork meeting room to install a door RECEIVED 03/15/2024 ASPEN BUILDING DEPARTMENT 4 Sampling Locations N A I i + ' ' , f j �;- 1 41 o t� A3le dIO A2� I I i i NTS 8.0- CONCLUSION: No asbestos was detected in any of the samples taken. Sincerely, Scott Roahrig e e m e n t 18.3 county rd 135 glenwood springs,co 81€" .274: 3 i ED www.elementconsults.com Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 � ��°%���24 ASPEN BUILDING DEPARTMENT 5 9.0- LAB REPORT tiff• eurofins CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Element Environmental LLC CLIENT PROJECT: City of Aspen 030424 Main LAB CODE: B244420 TEST METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORT DATE: 03/05/24 TOTAL SAMPLES ANALYZED: 3 #SAMPLES>1%ASBESTOS: 730 SE Maynard Road •Cary, NC 27511 •919.481.1413 e e m e n t 189 county rd 135 gLenwood springs,co 81€„ .274::3 i ED ,www.elementconsults.com Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAM 0 ��3/��D%��o 2 4 ASPEN BUILDING DEPARTMENT 6 eurofins Asbestos Report Summary ti By: POLARIZING LIGHT MICROSCOPY CEI PROJECT: City of Aspen 030424 Main LAB CODE: B244420 METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 ASBESTOS Client ID Layer Lab ID Color Sample Description 530 Al B244420.01 Gray,White Skip Trowel Texture None Detected 530 A2 B244420.02 Gray,White Skip Trowel Texture None Detected 530 A3 B244420.03 Gray,White Skip Trowel Texture None Detected 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 1 e e m e n t 18g county rd 135 glenwood springs,co 81€" .274:13 ID) www.elementconsults.com �n Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 ��3/y�D%��o24 ASPEN BUILDING DEPARTMENT 7 .:.• eurofins ASBESTOS BULK ANALYSIS ti• By: POLARIZING LIGHT MICROSCOPY CEI Client: Element Environmental LLC Lab Code: B244420 2314 Stone Creek Court Date Received: 03-05-24 Grand Junction, CO 81507 Date Analyzed: 03-05-24 Date Reported: 03-05-24 Project: City of Aspen 030424 Main ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON-ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non-Fibrous 530 Al Skip Trowel Texture Heterogeneous <1% Cellulose 20% Paint None Detected B244420.01 Gray,White 50% Binder Non-fibrous 30% Calc Carb Bound 530 A2 Skip Trowel Texture Heterogeneous <1% Cellulose 20% Paint None Detected B244420.02 Gray,White 50% Binder Non-fibrous 30% Calc Carb Bound 530 A3 Skip Trowel Texture Heterogeneous <1% Cellulose 20% Paint None Detected B244420.03 Gray,White 50% Binder Non-fibrous 30% Calc Carb Bound 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 1 of 2 e e m e n t 189 county rd 135 glen,wood springs,co 81€�^ .27q: 3 www.elementconsuLts.com Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAM tisto7To ASPEN BUILDING DEPARTMENT 8 eurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb =Calcium Carbonate METHOD: EPA 600/R93/116 and EPA 600/M4-82/020 REPORTING LIMIT: <1%by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25%by 400 Points or 0.1%by 1,000 Points REGULATORY LIMIT: >1%by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials(NOBs)such as vinyl floor tiles can be difficult to analyze via polarized light microscopy(PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on inquest. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: /( APPROVED BY: 44",. Nicholas Moore Tianbao Bai,Ph.D.,CIH Laboratory Director NVLA TESTING NVLAP LAB CODE 101768-0 730 SE Maynard Road•Cary,NC 27511 •919.481.1413 Page 2 of 2 e e m en 189 county rd 135 glenwood springs,co 81€„ 274 13 I i www.elementconsults.com I.•�w Project#-City of Aspen 030424 Main ENVIRONMENTAL NE LEAD ASBESTOS HAZ 0 ASPEN BUILDING DEPARTMENT 9 ASBESTOS SAMPLING FORM CE .LABS COMPANY CONTACT INFORMATION Company:Element Environmental Job Contact:Josh Johnson Project Name:C.0 01,qQn 030 I t'4 M01/1 Project ID#: Tel:970-274-3139 SAMPLE ID# _ DESCRIPTION/LOCATION _ TEST -- - - Si AI ))up re I NCI PLM I ITEM AL " �• 1 I PLM E]TEM PLM ( I TEM PLM I ITEM I I PLM I ITEM I I PLM TEM I I PLM 1 ITEM n PLM 1 ITEM I I PLM I ITEM I PLM I ITEM r� PLM I ITEM PLM E]TEM r� PLM I ITEM l I PLM ET TEM I I PLM I ITEM J PLM I-1TEM �-1 PLM I ITEM I PLM I I TEM I PLM I I TEM I I PLM ITEM I I PLM I—I TEM I I PLM I I TEM PLM f I TEM PLM I ITEM I J PLM I ITEM I I PLM I ITEM I I PLM [1 TEM I I PLM [—ITEM Page of I VERSION CCOC.0215.2/2.LD Customer COC Page 2 e e m e n t 18g county rd 135 glenwood springs,co 81€" .274 www.elementconsults.com LLss�i 66JJ Project#-City of Aspen 030424 Main ENVIRONMENTAL INC LEAD ASBESTOS HAZ 0 ��3/��D%��o24 ASPEN BUILDING DEPARTMENT 10 10.0- CERTIFICATES ,,:„.....,,_, ,a,. o Colorado Department � i4 I ,{ i. >\ 5.- of Public Health b tr, k' Colorado�!Publ ic t 6-- (.p and Environment !�N x ' (0 d Environment 7sr a,� r' • ASBESTOS a, 7 ASBESTOS �„ CERTIFICATION* r= t CERTIFICATION* �y, Ibis certifies that u; -, l his cenities that I� .f ui 1" 'a .'r, » Joshua Jay Johnson a 4 , Scott Roahrig i. Certification No.:18401 ("`_ -Q; Certification No.:29245 r ' -I has met the requirements of 25 7 507,C.R.S.and Air Quality Control it h t the requirements of''S 7 507,('.R.S d 1 Quality Control ' e 't Commt.Sinn Regulation No 8,i'a I B,and h by n 0ed by the C mmfss on Regulation No 8,Part B.and hereby certified by the S `-�' (u. state fit C olorado III the followingdisci line. t liggi state of Colorado m the follow fig disctpltne r P K ' I:' Building Inspector* 4 T Building Inspector* - Z. Issued: August 28,2023 issued: September 22,2023i '�. m f ., , -- Emmet, September 22.2024 yra '!Expires: August 31,2024 _- �` ff- ' e ,,, „its',, :R , „:��.:;,�. A 7_ '' ex- n� ,. to k l ..;M:.M.,rw. sets - 4"i a . } m a a a d M!: to 1 • f- t eN,♦" tff WIc\ liffi.'1V }4W qn V .a° ' a "��r„ J . � : ' ' .4 . JIB i'i ,7'Z h ..,w:..,: .„,,,,.e.; +�� . !`y=. 4f+ �,s.... k•v • c,,,,,,,,,,....i.):-...„ Colorado Department of Public Health and Environment ASBESTOS CONSULTING FIRM This certifies that Element Environmental,Inc. Registration No.:ACF-21640 has met the registration requirements of 25-7-507,C.R.S.and the Air Quality Control Commission Regulation No.8.Pan B.and is hereby authorized to perform asbestos consulting arts,sties as required under Regulation No 8,Part B.in the state of Colorado. I.,ucd: human" '0'i 3spo,.. lams n 31,,2025 d'ir .,,,,_ e e m e n t18g county rd 135 glenwood springs,co 81€ 27q 3 ) r) www.elementconsults.comEID Project#-City of Aspen 030424 Main ENVIRONMENTAL LEAD ASBESTOS HAZ tt /yst°% 0� o24 ASPEN BUILDING DEPARTMENT