HomeMy WebLinkAboutCO.320 W Bleeker St.0019-2021-BRES City of Aspen Area Weighted U Value Calculator V2 modified 12/10/13 Use this to calculate the actual U value of a framed assembly.The R value of cavity insulation is less than continuous insulation because it is broken up by studs,joists, or rafters.This calculator will figure out the actual R and U values of your assembly for use in the 2009 IECC U-factor alternative or for'other' assemblies in Rescheck and Comcheck dimensional lumber R value/inch 1.88 framing member depth (actual, inches) 5.5 framing member R value 10.34 framing member U value 0.096712 framing member width (actual, inches) 1.5 framing member spacing (inches o.c.) 16 cavity width 14.5 cavity insulation R value/inch 6.25 cavity insulation depth 5.5 cavity insulation R value 34.375 cavity insulation U value 0.029091 Area weighted avg R value 32.12172 Area weighted avg U value 0.03543 The City of Aspen has created and provided this software solely as a reference. Users should obtain assistance from a qualified professional to verify accuracy and applicability before proceeding. The City of Aspen makes no express or implied warranty with respect to this software or any information contained herein. To the full extent permissible by law, the City of Aspen disclaims all responsibility for any damages or losses (including, without limitation, structural damage, building defects, financial loss, damages for loss in business projects, loss of profits or other consequential losses) arising in contract, tort or otherwise from the use of or inability to use this software, or from any action or decision taken as a result of using this software.