Loading...
HomeMy WebLinkAboutCO.320 W Bleeker St.0019-2021-BRES (4) 0019-2021 -BRES_320 W Bleeker_BuildingCommentl 30.fenestration U-factor SKYLIGHT.20200728.pdf(1) Subject: PlanCheck This seems to just be a glass U Page: 1 Author:justinh value, provide overall U value for Color: • the skylight unit. File Name: 30.fenestration U-factor SKYLIGHT.20200728.pdf 1. 30.Fenestration U-factor windows and doors.20200728.pdf(1) Subject: PlanCheck Page: 1 Verify whether or not these all Author:justinh new door/windows will be NFRC =—= Color: • labeled at inspection. Providing ® a CPD report rather than a File Name: 30.Fenestration U-factor windows and NFRC spec seems to imply they doors.20200728.pdf will not. 2 If not, confirm that you will either provide a NFRC label certificate for the project at inspection or a signed affidavit/statement from the window provider that what was supplied matches what was specified at plan review to document the chain of custody. See our fenestration U factor documentation policy for more info(attached). 90.Architectural plans REVISED.20200728.pdf(3) Subject: PlanCheck �.Po.,,.. w Page:A-002 RREMP PLAN You are not including the upper Author:justinh level snowmelt in your m I Color: • calculation. �^ p 'j:jtee File Name: 90.Architectural plans REVISED.20200728.pdf N Snowmelt zone E is not shown jlllM ° as the same square footage in 1_Ih! _. 3. the drawing and table. Mechanical plan has a different i total snowmelt square footage -- """ than is shown here. Revise mechanical schedules, architectural plan and table and REMP worksheet so that snowmelt square footage is consistent in all plans/docs. — Subject: PlanCheck Office°a°y Drina originalper.ror Iola Page:A 002 RREMP PLAN Office copy of the original permit home(OM 20"pRBK'p°"a°°'"a"° Author:justinh for this home(0188.2017.ARBK) —ap.fl.°f appoveE anowmelt.Revlse ° ^°��"'a'°m«�'nar° onlyshows710 ft.of 7 Color: • • sq.ft. 10 00 File Name: 90.Architectural plans REVISED.20200728.pdf approved snowmelt. Revise existing plan and table to match that plan. o ,E. et 4. D.. RECEIVED 07/30/2021 ASPEN BUILDING DEPARTMENT ° -- Subject: PlanCheck "°°`�°'ersR`em�R o`rEo, Page:A-505 ADDITION DETAILS Wall sections need to show ,a„ER, Author:justinh thermal envelope energy code " Color: • compliance for the basement Wall sections need to snow Mermal envelope energy code File Name: 90.Architectural plans REVISED.20200728.pdf walls. No insulation values are compliance for the basemen walls.No insulation values called out, revise to demonstrate are call.out revise to demonstrate compliance. compliance. A DITON MAIN FLOOR TO FDN N/5 5 v 90.Mechanical Plans.20200628.pdf(1) Subject: PlanCheck Page: M100 MECHANICALSCHEDULES Environmental health limits Author:justinh mechanical noise to 55dBA I Color: • (daytime)and 50dBA(nighttime) ire measured at the property line. =_ , File Name: 90.Mechanical Plans.20200628.pdf = E. k Provide a spec on the new oo=000000 _.`� 7 6 9.li condensing unit that demonstrates compliance as this 6. is proposed just a few feet from o �— the property line. RECEIVED 07/30/2021 ASPEN BUILDING DEPARTMENT