HomeMy WebLinkAboutCO.320 W Bleeker St.0019-2021-BRES (4) 0019-2021 -BRES_320 W Bleeker_BuildingCommentl
30.fenestration U-factor SKYLIGHT.20200728.pdf(1)
Subject: PlanCheck This seems to just be a glass U
Page: 1 Author:justinh value, provide overall U value for
Color: • the skylight unit.
File Name: 30.fenestration U-factor SKYLIGHT.20200728.pdf
1.
30.Fenestration U-factor windows and doors.20200728.pdf(1)
Subject: PlanCheck
Page: 1 Verify whether or not these all
Author:justinh new door/windows will be NFRC
=—= Color: • labeled at inspection. Providing
® a CPD report rather than a
File Name: 30.Fenestration U-factor windows and NFRC spec seems to imply they
doors.20200728.pdf
will not.
2 If not, confirm that you will either
provide a NFRC label certificate
for the project at inspection or a
signed affidavit/statement from
the window provider that what
was supplied matches what was
specified at plan review to
document the chain of custody.
See our fenestration U factor
documentation policy for more
info(attached).
90.Architectural plans REVISED.20200728.pdf(3)
Subject: PlanCheck
�.Po.,,.. w Page:A-002 RREMP PLAN You are not including the upper
Author:justinh level snowmelt in your
m I Color: • calculation.
�^ p 'j:jtee File Name: 90.Architectural plans REVISED.20200728.pdf
N Snowmelt zone E is not shown
jlllM ° as the same square footage in
1_Ih! _. 3. the drawing and table.
Mechanical plan has a different
i total snowmelt square footage
-- """ than is shown here.
Revise mechanical schedules,
architectural plan and table and
REMP worksheet so that
snowmelt square footage is
consistent in all plans/docs.
— Subject: PlanCheck
Office°a°y Drina originalper.ror Iola
Page:A 002 RREMP PLAN Office copy of the original permit
home(OM
20"pRBK'p°"a°°'"a"° Author:justinh for this home(0188.2017.ARBK)
—ap.fl.°f appoveE anowmelt.Revlse
° ^°��"'a'°m«�'nar° onlyshows710 ft.of
7 Color: •
• sq.ft.
10 00 File Name: 90.Architectural plans REVISED.20200728.pdf approved snowmelt. Revise
existing plan and table to match
that plan.
o ,E. et
4.
D.. RECEIVED
07/30/2021
ASPEN
BUILDING DEPARTMENT
° -- Subject: PlanCheck
"°°`�°'ersR`em�R o`rEo, Page:A-505 ADDITION DETAILS Wall sections need to show
,a„ER, Author:justinh thermal envelope energy code
" Color: • compliance for the basement
Wall sections need to snow Mermal envelope energy code File Name: 90.Architectural plans REVISED.20200728.pdf walls. No insulation values are
compliance for the basemen walls.No insulation values called out, revise to demonstrate
are call.out revise to demonstrate compliance.
compliance.
A DITON MAIN FLOOR TO FDN N/5 5 v
90.Mechanical Plans.20200628.pdf(1)
Subject: PlanCheck
Page: M100 MECHANICALSCHEDULES Environmental health limits
Author:justinh
mechanical noise to 55dBA
I Color: • (daytime)and 50dBA(nighttime)
ire measured at the property line.
=_ , File Name: 90.Mechanical Plans.20200628.pdf
= E. k Provide a spec on the new
oo=000000 _.`� 7 6 9.li
condensing unit that
demonstrates compliance as this
6.
is proposed just a few feet from
o �— the property line.
RECEIVED
07/30/2021
ASPEN
BUILDING DEPARTMENT