HomeMy WebLinkAboutFile Documents.234 W Francis St.0118-2020-BRES (45) 2015 IECC REMP WORKSHEET INSTRUCTIONS CITY OF ASPEN VERSION 113 UPDATED DECEMBER 13, 2017 As adopted by Ordinance 40, 2016 1 REMP Submittal Requirements: * Contact a Permit Coordinator for requirements for all departments including Zoning, Parks, Utilities, and Engineering. See the following checklists and submittal guides for building department requirements: IRC Checklist IRC Submittal guide IBC Checklist IBC Submittal guide 2 Worksheet Instructions: * Find the appropriate worksheet in the tabs below. (R-REMP sheet for residential) (C-REMP sheet for commercial or 4+story residential) * Complete the upper half of the worksheet, including the project address, permit number, parcel ID and all contact information * List all drawing sheets that have REMP information, such as site plans and mechanical plans. * The building official may approve an exemption from REMP in certain cases as described in Ordinance 40, 2016. If you have received approval for this exemption, check the 'yes' box and enter the exempt sqft portions in the new (exempt) row. * Enter all existing onsite snowmelt/spa/pool areas and amounts to be removed or replaced. * Enter new square footages (snowmelt, spa and/or pool) including replaced areas. * The intent is to document all snowmelt, spa, and pool areas on the entire site. Change orders should show the complete picture, including previous change orders and the master permit. * Enter the boiler efficiency being used per manufacturer specifications Note: Boiler efficiency is a minimum of 75%. Electric snowmelt automatically gets 100%. * The mitigation payment due will be shown in the green-tinted box. * If you are planning to install supplemental energy systems: * Determine the type(s)of system and use the appropriate worksheet in the tabs below. PV Worksheet for photovoltaic solar systems Solar Thermal Worksheet for solar hot water systems GSHP Cert for groundsource heat pump systems * The mitigation credits for each system will be automatically entered into your RREMP or CREMP form. If your project has both RREMP and CREMP, it will automatically divide the credits up, with priority given to mitigating the CREMP payment. * The total mitigation credits are subtracted from the total mitigation payment to give you a total REMP payment. * If you previously paid a REMP payment as part of this project, enter the amount previously paid. If a refund is due, it will be displayed. Note that per policy, $750 is deducted from refunds for administrative expenses. Expires 180 days after certificate of occupancy. 2015 IECC RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM CITY OF ASPEN VERSION 11,3 UPDATED DECEMBER 13, 2017 PROJECT ADDRESS: 234 W. Francis St. Aspen Parcel ID#: 2735 - 124- 17-003 Permit Number: CONTACT INFORMATION : Owner: Name: City: Address: State: Email: Zip Code: Phone: Cell Phone: Owner's Representative: Name: Derek Skalko City: Aspen Address: 1 FRIDAY DESIGN, PO Box 7928, State: CO Email: derek@lfriday.com Zip Code: 81612 Phone: 970.309.0695 Cell Phone: A. RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM Sheets showing snowmelt, pool, spa, and solar/GSHP information: M0.02, M1.01, M1.02, M2.01, M2.03 Do you have snowmelt or a spa that has been exempted by the buiding official? 0 Yes(enter sqft below on the exempt row) @ No Hydro Snowmelt Electric Snowmelt Pool Spa Existing To be Demoed Existing to Remain 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft New(non-exempt) 1015.00 sqft 56.00 sqft New(exempt) Total New 1015.00 sqft 0.00 sqft 0.00 sqft 56.00 sqft J Total on site 1015.00 sqft 0.00 sqft 0.00 sqft 56.00 sqft Total Snowmelt on site 1015.00 sqft Boiler Efficiency 95.0% I 100% 75.0% 95.0% Mitigation Payment $36,326.32 $ - $ 10,374.74 Total Payment for Mitigation: $ 46,701.05 B. ON-SITE RENEWABLE CREDITS Supplemental System REMP Credit Use PV Worksheet Photovoltaic System $ 35,436.79 Use Thermal Worksheet Hot Water Panels $Use GSHP Cert Ground Source Heat Pump $ - Other Approved System $ - RECEIVED Total Mitigation Credits: $ 35,436.79 Onsite Renewable Offsets: How many Kilo Watts of PV(solar electric)would I need? 6.80 or How many square feet of SHW(solar hot water)would I need? 207.88 02/10/2022 R-REMP Payment: $ 11,264.26 ASPEN Amount Previously Paid on This Permit: BUILDING DEPARTMENT I TOTAL R-REMP PAYMENT: $ 11,264.26 Refund (includes minus$750): $ - C. PREPARED BY: Date: 12/2/2021 Print Name: Dodson Harper, PE Signature: gdodsonharper Phone& EMail: 970.349.1216, dodson@reginc.com REVIEWED: Date: 2015 IECC COMMERCIAL RENEWABLE ENERGY MITIGATION PROGRAM CITY OF ASPEN VERSION 1,1,3 UPDATED DECTMB'E.7 13, 2017 PROJECT ADDRESS: Parcel ID#: Permit Number: CONTACT INFORMATION : Owner: Name: City: Address: State: Email: Zip Code: Phone: Cell Phone: Owner's Representative: Name: City: Address: State: Email: Zip Code: Phone: Cell Phone: A. COMMERCIAL RENEWABLE ENERGY MITIGATION PROGRAM Sheets showing snowmelt, pool, spa, and solar/GSHP information: Do you have snowmelt or a spa that has been exempted by the buiding official? 0 Yes(enter sqft below on the exempt row) 0 No Hydro Snowmelt Electric Snowmelt Pool Spa Existing To be Demoed Existing to Remain 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft New(non-exempt) New(exempt) Total New 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft Total on site 0.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft Total Snowmelt on site 0.00 sqft Boiler Efficiency 75.0% 100% 75.0% 75.0% Mitigation Payment $0.00 $ - $ - Total Payment for Mitigation: $0.00 B. ON-SITE RENEWABLE CREDITS Supplemental System REMP Credit Use PV Worksheet Photovoltaic System $Use Thermal Worksheet Hot Water Panels $Use GSHP Cert Ground Source Heat Pump $ - Other Approved System $ - Total Mitigation Credits: $ - Onsite Renewable Offsets: How many Kilo Watts of PV(solar electric)would I need? 0.00 or How many square feet of SHW(solar hot water)would I need? 0.00 C-REMP Payment: $ - Amount Previously Paid on This Permit: $ - TOTAL C-REMP PAYMENT: $ - Refund (includes minus$750): $C. PREPARED BY: Date: Print Name: Signature: Phone&EMail: REVIEWED: Date: PV WORKSHEET CITY OF ASPEN VERSION 11.5 UPDATED MAY 14,2021 PROJECT ADDRESS: 234 West Francis,Aspen CO 81611 Parcel ID#: 2735-124-17-003 Permit Number: Collector Solar Aspect,Degrees Collector Tilt, Orientation from True South Degrees From Adjustment DC side capacity Inverter capacity kW for kW Mitigation Horizontal Factor (kW) (kW) credit Credit Collector Group 1 15 0 87.00% 6.55 5.933 5.933 5.16 kW Collector Group 2 87.00% 0 0.00 kW Collector Group 3 87.00% 0 0.00 kW Collector Group 4 87.00% 0 0.00 kW Collector Group 5 87.00% 0 0.00 kW Collector Group 6 87.00% 0 0.00 kW Collector Group 7 87.00% 0 0.00 kW Collector Group 8 87.00% 0 0.00 kW Collector Group 9 87.00% 0 0.00 kW Collector Group 10 87.00% 0 0.00 kW Collector Group 11 87.00% 0 0.00 kW Collector Group 12 87.00% 0 0.00 kW Collector Group 13 87.00% 0 0.00 kW Collector Group 14 87.00% 0 0.00 kW Collector Group 15 87.00% 0 0.00 kW Collector Group 16 87.00% 0 0.00 kW Collector Group 17 87.00% 0 0.00 kW Collector Group 18 87.00% 0 0.00 kW Collector Group 19 87.00% 0 0.00 kW Collector Group 20 87.00% 0 0.00 kW Total: 5.16 kW $Mitigation Credit: $ 35,436.79 Instructions: 1) Determine how many collector groups you have.Groups are used to differentiate between collectors (panels)with different tilts,aspects,sizing,or inverters. If all your collectors are installed similarily,you might have just one group. 2) Enter the aspect and tilt for each group.The solar orientation adjustment factor is automatically calculated. 3) DC side capacity is the total labled panel output kW in a group. 4) Inverter capacity is the recommended output power in kW of your inverter(s). 5) You will be given credit for the lesser of the labeled panel output or the inverter. 6) The kW for credit is multiplied by the solar orientation adjustment factor to get kW mitigation credit. 7) The kW mitigation credit is totalled and multiplied by$6865.32/kW to get the$Mitigation Credit 8) The mitigation credit will be automatically entered into your RREMP or CREMP form. If your project has both RREMP and CREMP,it will automatically divide the credits up,with priority given to mitigating the CREMP payment. PREPARED BY: Date: 12/2/2021 Print Name: Greg Peterson Signature: Greg K Peterson Phone&EMail: 970.963.1420; greg@sunsensesolar.com REVIEWED: Date: RECEIVE _, 02/10/2022 ASPEN BUILDING DEPARTMENT SOLAR THERMAL WORKSHEET CITY OF ASPEN VERSION 11.3 UPDATED DECEA BER 13, 2017 PROJECT ADDRESS: Parcel ID#: Permit Number: Collector Solar Aspect, Collector Tilt, Orientation Degress from Degrees From Adjustment Square feet of Sqft Mitigation True South Horizontal Factor collectors Credit Collector Group 1 87.00% 0.00 sqft Collector Group 2 87.00% 0.00 sqft Collector Group 3 87.00% 0.00 sqft Collector Group 4 87.00% 0.00 sqft Collector Group 5 87.00% 0.00 sqft Collector Group 6 87.00% 0.00 sqft Collector Group 7 87.00% 0.00 sqft Collector Group 8 87.00% 0.00 sqft Collector Group 9 87.00% 0.00 sqft Collector Group 10 87.00% 0.00 sqft Collector Group 11 87.00% 0.00 sqft Collector Group 12 87.00% 0.00 sqft Collector Group 13 87.00% 0.00 sqft Collector Group 14 87.00% 0.00 sqft Collector Group 15 87.00% 0.00 sqft Collector Group 16 87.00% 0.00 sqft Collector Group 17 87.00% 0.00 sqft Collector Group 18 87.00% 0.00 sqft Collector Group 19 87.00% 0.00 sqft Collector Group 20 87.00% 0.00 sqft Total: 0.00 sqft $ Mitigation Credit: $ - Instructions: 1) Determine how many collector groups you have. Groups are used to differentiate between collectors (panels)with different tilts, aspects, sizing, or inverters. If all your collectors are installed similarily, you might have just one group. 2) Enter the aspect and tilt for each group. The solar orientation adjustment factor is automatically calculated. 3) Enter the square the total panel square footage in each group. 4) The square footage is multiplied by the solar orientation adjustment factor to get Sqft mitigation credit. 5) The kW mitigation credit is totalled and multiplied by$224.65/sqft to get the $ Mitigation Credit 6) The mitigation credit will be automatically entered into your RREMP or CREMP form. If your project has both RREMP and CREMP, it will automatically divide the credits up, with priority given to mitigating the CREMP payment. PREPARED BY: Date: Print Name: Signature: Phone& EMail: REVIEWED: Date: GROUND SOURCE HEAT PUMP SOURCE CERTIFICATION CITY OF ASPEN VERSION 11.3 UPDATED DECEMEER 13, 2017 Project Address: Parcel ID#: Permit Number: All Ground Source Heat Pump systems must be certified prior to installation; please provide all the required information as part of your application. I. Please list the following information BTUs per hour of installed GSHP: $ Mitigation Credit: $ - Agency Designer Certification: AEE CGD Number: Installer Accreditation: IGSHPA Number: Division of Water Resources Permit: II. GSHP System Design Specifications Number of Loops: Depth of Loops: ft. Total Loop Length: ft. Total System Capacity @ 32 °F EWT: tons ARI 330 or ISO 13256-1System Performance: COP Coefficient of Performance of the system must be at least 3 as per American Research Institute Standard performance method (ARI 330)or ISO 13256-1 for closed loop earth- coupled heat pump systems (for hydronic systems use an output temperature of 115 degrees F)or equivalent procedure. III. Attach the following information with application. A. GSHP unit performance sheets certified by ARI 330 or ISO 13256-1. B. Designer Certification Sheets C. Installer Certification Sheets D. Division of Water Resource Permit NOTE: A GSHP is an energy-efficient option that significantly reduces energy use and minimizes REMP payments. The REMP payment associated with a GSHP is used to offset the coal powered electricity over 20 years. This option is calculated on REMP summary sheet. IV. PREPARED BY: Date: Print Name: Signature: Phone&EMail: REVIEWED: Date: Collector Tilt,Degrees From Horizontal 0 10 20 30 40 50 60 I 70 80 I 90 0 87.00% 93.20% 97.60% 99.90% 100% 98.00% 93.90% 87.80% 80.00% 70.70% 10 87.00% 93.10% 97.40% 99.70% 99.80% 97.70% 93.60% 87.60% 79.90% 70.70% Collector 20 87.00% 92.80% 96.90% 99.00% 99.10% 97.10% 93.00% 87.10% 79.60% 70.70% Aspect 30 87.00% 92.40% 96.10% 98.00% 97.90% 95.90% 92.00% 86.20% 79.00% 70.50% Degrees 40 87.00% 91.80% 95.00% 96.60% 96.40% 94.30% 90.50% 85.00% 78.10% 70.00% From 50 87.00% 91.00% 93.70% 94.80% 94.30% 92.20% 88.50% 83.20% 76.70% 69.10% TRUE 60 87.00% 90.00% 92.00% 92.70% 91.90% 89.60% 86.00% 80.90% 74.70% 67.60% South 70 87.00% 89.00% 90.10% 90.20% 89.00% 86.60% 82.90% 78.10% 72.20% 65.50% 80 87.00% 87.90% 88.10% 87.40% 85.70% 83.00% 79.30% 74.60% 69.10% 62.80% 90 87.00% 86.70% 85.80% 84.30% 82.10% 79.10% 75.20% 70.60% 65.30% 59.50% 100 87.00% 85.16% 83.08% 80.70% 77.88% 74.62% 70.74% 66.45% 61.63% 56.43%_ 110 87.00% 83.57% 80.18% 76.79% 73.30% 69.69% 65.70% 61.65% 57.23% 52.60%_ 120 87.00% 81.83% 77.01% 72.52% 68.29% 64.29% 60.18% 56.36% 52.35% 48.32% 130 87.00% 79.95% 73.58% 67.90% 62.85% 58.42% 54.15% 50.58% 47.00% 43.60%_ 140 87.00% 77.93% 69.89% 62.91% 56.99% 52.08% 47.63% 44.31% 41.19% 38.44%_ 150 87.00% 75.77% 65.93% 57.57% 50.69% 45.27% 40.62% 37.56% 34.89% 32.83%_ 160 87.00% 73.46% 61.71% 51.86% 43.96% 37.98% 33.10% 30.31% 28.13% 26.78% 170 87.00% 71.02% 57.23% 45.80% 36.80% 30.23% 25.10% 22.58% 20.90% 20.28%_ 180 87.00% 68.43% 52.49% 39.37% 29.22% 22.00% 16.59% 14.36% 13.19% 13.34% Efficiency°bioased on aspect and tilt 100.00% ••••••-•-• •.... ..... - 20 I • ,,..,, • '""•.., - ! t r • • ; ; �' ' '••J=: • • • • • • • • I •... 90.00% ''+.. ., sa .• 80.00% •. ♦ •.............• •.... ••''••.,+• j6' •., • • ' + •.••••.., •............. ..... • Roly.(0) •., • •.... :•.,:: Poly.( )., •, ••+•., ... •... o •.............* •............. •,•Poly, 0) •• '••• . • • 70.00 ....... ':/... •. Poly.(30) • • • • .• IF Poly.(,) •, • S. •. +.., Poly.(SO) •. 60.00% Po1v:.421 ••, • • •. ▪'lbPoly.(70) ,•• Poly.(80) Poly.(90) ''••. •.•• "0. 50.00% • • •` R . V. *. •� 40.00% ~'• • • • - ▪ • 30.00% •• •: ••. 20.00% i:•.' 10.00% 0 20 40 60 80 100 120 140 160 180