HomeMy WebLinkAboutFile Documents.234 W Francis St.0118-2020-BRES (53) GComplianceenerated by REScheck-Web Software Certificate Project 234 West Francis [Addition] SEE NOTES #1 PLANS Energy Code: 2015 IECC D wiewei 0 Location: Aspen, Colorado Construction Type: Single-family 12/23/2022 Project Type: Addition Orientation: Bldg. faces 225 deg. from North FORCOIX UWE Climate Zone: 7 (9922 HDD) justinh Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 234 West Francis Steve Ells John Spencer Aspen, CO 81511 Selldorf Architects 860 Broadway New York, NY 10003 2122199571 amber@bairullc.com Compliance: Passes using UA trade-off Compliance: 24.7%Better Than Code Maximum UA: 574 Your UA: 432 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Assembly or R-Value R-Value U-Factor U-Factor UA UA Perimeter 09 - Basement Roof: Flat Ceiling or Scissor Truss 1,260 36.0 28.0 0.017 0.026 21 33 11 - Flat Roof: Flat Ceiling or Scissor Truss 780 49.0 18.0 0.018 0.026 14 20 12 -Sloped Metal Roof: Cathedral Ceiling 875 49.0 7.0 0.019 0.026 16 22 206: Wood Frame 6 0.550 0.550 3 3 204: Wood Frame 10 0.550 0.550 6 6 207: Wood Frame 10 0.550 0.550 6 6 205: Wood Frame 6 0.550 0.550 3 3 Exterior Wall at Addition Pocket: Wood Frame, 16" o.c. 405 39.0 19.0 0.021 0.045 5 11 Orientation: Front 102: Glass Door(over 50%glazing) 160 0.280 0.320 45 51 Orientation: Front Exterior Wall at Addition [South]: Wood Frame, 16" o.c. 85 19.0 10.0 0.036 0.045 2 3 Orientation: Front ED105: Solid Door(under 50%glazing) 22 0.280 "RECEIVED Orientation: Front 1 2 /1 9 /2n22 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: ASS RJ1 ofll BUILDING DEPARTMENT Gross Area Cavity Cont. Prop. Req. Prop. Req. Assembly or R-Value R-Value U-Factor U-Factor UA UA Perimeter Exterior Wall at Addition [West]: Wood Frame, 16" o.c. 625 19.0 10.0 0.036 0.045 19 23 Orientation: Left side ED106: Solid Door(under 50%glazing) 26 0.280 0.320 7 8 Orientation: Left side 105: Wood Frame 12 0.280 0.320 3 4 Orientation: Left side 202: Wood Frame Orientation: Left side 13 0.280 0.320 4 4 203: Wood Frame 13 0.280 0.320 4 4 Orientation: Left side 116: Wood Frame 45 0.280 0.320 13 14 Orientation: Left side Exterior Wall at Addition [North]: Wood Frame, 16" o.c. 650 19.0 10.0 0.036 0.045 19 23 Orientation: Back ED104: Solid Door(under 50%glazing) 134 0.400 0.320 54 43 Orientation: Back Exterior Wall at Addition [East]: Wood Frame, 16" o.c. 625 19.0 10.0 0.036 0.045 19 24 Orientation: Right side 101: Wood Frame 35 0.280 0.320 10 11 Orientation: Right side 201: Wood Frame 12 0.280 0.320 3 4 Orientation: Right side 103: Wood Frame 23 0.280 0.320 6 7 Orientation: Right side 104: Wood Frame 23 0.280 0.320 6 7 Orientation: Right side Basement Floor: Slab-On-Grade (Heated) 350 15.0 0.655 0.655 0 0 Insulation depth: 4.0' Exterior Foundation Wall -One Sided Pour: Solid Concrete or Masonry Orientation: Unspecified 1,800 13.0 21.0 0.026 0.050 46 89 Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 11.0' 005: Wood Frame 16 0.280 0.320 5 5 Orientation: Unspecified Exterior Foundation Wall -Two Sided Pour: Solid Concrete or Masonry Orientation: Unspecified 2,520 13.0 15.0 0.029 0.050 71 123 Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 11.0' 001: Wood Frame 16 0.280 0.320 5 5 Orientation: Unspecified 002: Wood Frame 16 0.280 0.320 5 5 Orientation: Unspecified 004: Wood Frame Orientation: Unspecified 14 0.280 0.320 4 4 003: Wood Frame 8 0.280 0.320 2 2 Orientation: Unspecified RECEIVED 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: ASFpgRi2 of11 BUILDING DEPARTMENT Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has be: designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory require -4 s listed in tj- REScheck Inspection Checklist. Air Callaghan Fenerty - Project Engineer 08/23/2022 Name-Title Signature / / Date Project Notes: 'Front' = Plan South. Numerals appearing in front of roof assemblies correspond to architectural envelope details. Wall assemblies are grouped by orientation and do not have corresponding numerals given the worst case assemblies were used through out. RECEIVED 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: AsFIDEN3 ofll BUILDING DEPARTMENT REScheck Software VersionChecklist: REScheck-Web Energy Code: 2015 IECC Requirements: 2.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, ;Construction drawings and Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ['Not Observable fil, Systems serving multiple ENot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 1 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ['Not Observable Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: RECEIVED 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: AsFM4 ofll BUILDING DEPARTMENT Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [FO1]1 ❑ Unheated ❑ Unheated ElDoes Not table for values. .o ❑ Heated ❑ Heated [Not Observable ENot Applicable 402.1.2 Slab edge insulation ft ft EComplies See the Envelope Assemblies [FO3]1 depth/length. ❑Does Not table for values. ['Not Observable 1 ❑Not Applicable 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values. • insulation is used, verification ['Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not O manufacturer's instructions. ['Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. �, distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ['Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO controls installed. ❑Does Not ['Not Observable ❑Not Applicable Additional Comments/Assumptions: RECEIVED 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: ASRF �'ti5 ofll BUILDING DEPARTMENT Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 [Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 [Not Observable [FR2]1 ❑Not Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or [Not Observable taken from the default table. ❑Not Applicable 402.1.1, Skylight U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.3, ❑Does Not table for values. 402.3.6, 402.5 ['Not Observable [FR5]1 ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. [Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built EComplies [FR20]1 is listed and labeled as meeting ❑Does Not 0 AAMA/WDMA/CSA 101/I.S.2/A440 ['Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4. IC-rated recessed lighting fixtures ❑Complies [FR16] sealed at housing/interior finish El Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ['Not Observable ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ElDoes Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ['Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not dJ ['Not Observable ❑Not Applicable 403.4 :HVAC piping conveying fluids R- R- ❑Complies [FR17]z above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to >_R 3 ['Not Observable ❑Not Applicable 403.4.1 :Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ['Not Observable ❑Not Applicable RECEIVED 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: AsR EEN6 ofli BUILDING DEPARTMENT Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 •R-3. ❑Does Not J [Not Observable ❑Not Applicable 403.6 ;Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. [Not Observable ❑Not Applicable Additional Comments/Assumptions: RECEIVED 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: jAsP-og 7 ofll BUILDING DEPARTMENT Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ;All installed insulation is labeled '❑Complies [IN13]2 or the installed R-values ❑Does Not 0 provided. lot Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [Not Observable [IN3]1 exterior,the exterior insulation 4 requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 :Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable j ❑Not Applicable Additional Comments/Assumptions: RECEIVED 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: AsR EEN8 ofll BUILDING DEPARTMENT Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID_ 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, j ❑ Steel ❑ Steel [Not Observable 402.2.6 [FI1]1 ENot Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. [Not Observable ENot Applicable 402.2.3 !Vented attics with air permeable EComplies Exception: Requirement is [F122]2 insulation include baffle adjacent ❑Does Not not applicable. to soffit and eave vents that ;extends over insulation. [Not Observable j ENot Applicable 402.2.4 Attic access hatch and door R- R- EComplies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. [Not Observable ENot Applicable 402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies [F117]1 ach in Climate Zones 1-2, and ❑Does Not I<=3 ach in Climate Zones 3-8. ENot Observable j ENot Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies [F14]1 cfm/100 ft2 across the system or ft2 ftz ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ['Not Observable tests,verification may need to ENot Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 EComplies [F127]1 determine air leakage with ft2 ft2 Does Not either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ENot Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated EComplies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ENot Applicable 403.1.1 :Programmable thermostats r EComplies [F19]2 installed for control of primary ❑Does Not ;heating and cooling systems and :initially set by manufacturer to ['Not Observable i code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F110]2 on heat pumps. ❑Does Not ENot Observable ❑Not Applicable 403.5. Circulating service hot water qElComPlies [F111]z systems have automatic or EDoes Not accessible manual controls. ['Not Observable ENot Applicable RECEIVE 0 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: AsP EEN9 ofll BUILDING DEPARTMENT Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 ;All mechanical ventilation system ' •Complies [F125]2 fans not part of tested and listed •Does Not HVAC equipment meet efficacy and air flow limits. •Not Observable 403.2 j Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not ailsystems have outdoor setback control to lower boiler water [Not Observable temperature based on outdoor ❑Not Applicable j temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply [Not Observable pipe. Gravity and thermos- ENot Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the 41'occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 'Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL El Does Not 515. Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the ;piping. 403.5.2 Water distribution systems that 1 ❑Complies [F130]2 have recirculation pumps that EDoes Not pump water from a heated water supply pipe back to the heated ['Not Observable water source through a cold ENot Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold :water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat [Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for ;individual units connected to :three or more showers. 403.10.2 ;Readily accessible switch on ❑Complies [F112]3 heaters for swimming pools or ❑Does Not :permanent in-ground spas. Switch operation does not ['Not Observable change heater thermostat ENot Applicable setting. Heater circuit breaker is installed independent of switch. :Gas-fired heaters equipped with ignition pilots that are notJ11 I continuously burning pilots. Jul 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: i.AFaigE.1ll0 ofll BUILDING DEPARTMENT Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.10.3 Timer switches or other '❑Complies [F119]3 1 automatic preset schedule 1L1Does Not control method are installed on heaters and pumps serving pools [Not Observable and permanent ❑Not Applicable 403.10.4 Outdoor heated pools and Complies [F120]3 outdoor permanent spas have a ElDoes Not vapor retardant cover. ['Not Observable '❑Not Applicable 404.1 75%of lamps in permanent EComplies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage [Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have EComplies [F123]3 no continuous pilot light. ❑Does Not d' ['Not Observable ❑Not Applicable 401.3 (Compliance certificate posted. EComplies [F17]2 EDoes Not ['Not Observable ❑Not Applicable 303.3 :Manufacturer manuals for EComplies [F118]3 mechanical and water heating ❑Does Not :systems have been provided. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: RECEIVED 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 12/19/2022 Project Title: 234 West Francis [Addition] Report date: 08/23/22 Data filename: Page`A1 ofll BUILDING DLPARTMENT 2015 IECC Energy Efficiency Certificate Insulation Rating Above-Grade Wall 29.00 Below-Grade Wall 28.00 Floor 15.00 Ceiling / Roof 64.00 Ductwork (unconditioned spaces): Glass & Door Rating U-Factor SHGC Window 0.28 Door 0.28 Skylight 0.55 Heating & Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments RECEIVED 12/19/2022 ASPEN BUILDING DEPARTMENT