HomeMy WebLinkAboutFile Documents.234 W Francis St.0118-2020-BRES (53) GComplianceenerated by REScheck-Web Software
Certificate
Project 234 West Francis [Addition] SEE NOTES #1 PLANS
Energy Code: 2015 IECC D wiewei
0
Location: Aspen, Colorado
Construction Type: Single-family 12/23/2022
Project Type: Addition
Orientation: Bldg. faces 225 deg. from North FORCOIX UWE
Climate Zone: 7 (9922 HDD) justinh
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
234 West Francis Steve Ells John Spencer
Aspen, CO 81511 Selldorf Architects
860 Broadway
New York, NY 10003
2122199571
amber@bairullc.com
Compliance: Passes using UA trade-off
Compliance: 24.7%Better Than Code Maximum UA: 574 Your UA: 432
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or R-Value R-Value U-Factor U-Factor UA UA
Perimeter
09 - Basement Roof: Flat Ceiling or Scissor Truss 1,260 36.0 28.0 0.017 0.026 21 33
11 - Flat Roof: Flat Ceiling or Scissor Truss 780 49.0 18.0 0.018 0.026 14 20
12 -Sloped Metal Roof: Cathedral Ceiling 875 49.0 7.0 0.019 0.026 16 22
206: Wood Frame 6 0.550 0.550 3 3
204: Wood Frame 10 0.550 0.550 6 6
207: Wood Frame 10 0.550 0.550 6 6
205: Wood Frame 6 0.550 0.550 3 3
Exterior Wall at Addition Pocket: Wood Frame, 16"
o.c. 405 39.0 19.0 0.021 0.045 5 11
Orientation: Front
102: Glass Door(over 50%glazing) 160 0.280 0.320 45 51
Orientation: Front
Exterior Wall at Addition [South]: Wood Frame, 16"
o.c. 85 19.0 10.0 0.036 0.045 2 3
Orientation: Front
ED105: Solid Door(under 50%glazing) 22 0.280 "RECEIVED
Orientation: Front
1 2 /1 9 /2n22
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: ASS RJ1 ofll
BUILDING DEPARTMENT
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or R-Value R-Value U-Factor U-Factor UA UA
Perimeter
Exterior Wall at Addition [West]: Wood Frame, 16"
o.c. 625 19.0 10.0 0.036 0.045 19 23
Orientation: Left side
ED106: Solid Door(under 50%glazing) 26 0.280 0.320 7 8
Orientation: Left side
105: Wood Frame 12 0.280 0.320 3 4
Orientation: Left side
202: Wood Frame
Orientation: Left side 13 0.280 0.320 4 4
203: Wood Frame 13 0.280 0.320 4 4
Orientation: Left side
116: Wood Frame 45 0.280 0.320 13 14
Orientation: Left side
Exterior Wall at Addition [North]: Wood Frame, 16"
o.c. 650 19.0 10.0 0.036 0.045 19 23
Orientation: Back
ED104: Solid Door(under 50%glazing) 134 0.400 0.320 54 43
Orientation: Back
Exterior Wall at Addition [East]: Wood Frame, 16"
o.c. 625 19.0 10.0 0.036 0.045 19 24
Orientation: Right side
101: Wood Frame 35 0.280 0.320 10 11
Orientation: Right side
201: Wood Frame 12 0.280 0.320 3 4
Orientation: Right side
103: Wood Frame 23 0.280 0.320 6 7
Orientation: Right side
104: Wood Frame 23 0.280 0.320 6 7
Orientation: Right side
Basement Floor: Slab-On-Grade (Heated) 350 15.0 0.655 0.655 0 0
Insulation depth: 4.0'
Exterior Foundation Wall -One Sided Pour: Solid
Concrete or Masonry
Orientation: Unspecified 1,800 13.0 21.0 0.026 0.050 46 89
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 11.0'
005: Wood Frame 16 0.280 0.320 5 5
Orientation: Unspecified
Exterior Foundation Wall -Two Sided Pour: Solid
Concrete or Masonry
Orientation: Unspecified 2,520 13.0 15.0 0.029 0.050 71 123
Wall height: 12.0'
Depth below grade: 12.0'
Insulation depth: 11.0'
001: Wood Frame 16 0.280 0.320 5 5
Orientation: Unspecified
002: Wood Frame 16 0.280 0.320 5 5
Orientation: Unspecified
004: Wood Frame
Orientation: Unspecified 14 0.280 0.320 4 4
003: Wood Frame 8 0.280 0.320 2 2
Orientation: Unspecified
RECEIVED
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: ASFpgRi2 of11
BUILDING DEPARTMENT
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has be: designed to meet the 2015 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory require -4 s listed in tj- REScheck Inspection Checklist.
Air
Callaghan Fenerty - Project Engineer 08/23/2022
Name-Title Signature / / Date
Project Notes:
'Front' = Plan South. Numerals appearing in front of roof assemblies correspond to architectural envelope details.
Wall assemblies are grouped by orientation and do not have corresponding numerals given the worst case
assemblies were used through out.
RECEIVED
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: AsFIDEN3 ofll
BUILDING DEPARTMENT
REScheck Software VersionChecklist: REScheck-Web
Energy Code: 2015 IECC
Requirements: 2.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, ;Construction drawings and Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ['Not Observable
fil, Systems serving multiple ENot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 1
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ['Not Observable
Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
RECEIVED
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: AsFM4 ofll
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[FO1]1 ❑ Unheated ❑ Unheated ElDoes Not table for values.
.o ❑ Heated ❑ Heated [Not Observable
ENot Applicable
402.1.2 Slab edge insulation ft ft EComplies See the Envelope Assemblies
[FO3]1 depth/length. ❑Does Not table for values.
['Not Observable
1 ❑Not Applicable
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values.
• insulation is used, verification ['Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
O manufacturer's instructions. ['Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
�, distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ['Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO controls installed. ❑Does Not
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
RECEIVED
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: ASRF �'ti5 ofll
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 [Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 [Not Observable
[FR2]1 ❑Not Applicable
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or [Not Observable
taken from the default table.
❑Not Applicable
402.1.1, Skylight U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.3, ❑Does Not table for values.
402.3.6,
402.5 ['Not Observable
[FR5]1 ❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. [Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built EComplies
[FR20]1 is listed and labeled as meeting ❑Does Not
0 AAMA/WDMA/CSA 101/I.S.2/A440 ['Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
402.4. IC-rated recessed lighting fixtures ❑Complies
[FR16] sealed at housing/interior finish El Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ['Not Observable
❑Not Applicable
403.3.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ElDoes Not
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and ['Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
dJ ['Not Observable
❑Not Applicable
403.4 :HVAC piping conveying fluids R- R- ❑Complies
[FR17]z above 105 °F or chilled fluids ❑Does Not
below 55 °F are insulated to >_R
3 ['Not Observable
❑Not Applicable
403.4.1 :Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
['Not Observable
❑Not Applicable
RECEIVED
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: AsR EEN6 ofli
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 •R-3. ❑Does Not
J [Not Observable
❑Not Applicable
403.6 ;Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
RECEIVED
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: jAsP-og 7 ofll
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 ;All installed insulation is labeled '❑Complies
[IN13]2 or the installed R-values ❑Does Not
0 provided. lot
Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [Not Observable
[IN3]1 exterior,the exterior insulation
4 requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 :Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
j ❑Not Applicable
Additional Comments/Assumptions:
RECEIVED
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: AsR EEN8 ofll
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID_
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, j ❑ Steel ❑ Steel [Not Observable
402.2.6
[FI1]1 ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. [Not Observable
ENot Applicable
402.2.3 !Vented attics with air permeable EComplies Exception: Requirement is
[F122]2 insulation include baffle adjacent ❑Does Not not applicable.
to soffit and eave vents that
;extends over insulation. [Not Observable
j ENot Applicable
402.2.4 Attic access hatch and door R- R- EComplies
[F13]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
[Not Observable
ENot Applicable
402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
I<=3 ach in Climate Zones 3-8.
ENot Observable
j ENot Applicable
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies
[F14]1 cfm/100 ft2 across the system or ft2 ftz ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ['Not Observable
tests,verification may need to ENot Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 EComplies
[F127]1 determine air leakage with ft2 ft2 Does Not
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ENot Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated EComplies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
ENot Applicable
403.1.1 :Programmable thermostats r EComplies
[F19]2 installed for control of primary ❑Does Not
;heating and cooling systems and
:initially set by manufacturer to ['Not Observable
i
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. ❑Does Not
ENot Observable
❑Not Applicable
403.5. Circulating service hot water qElComPlies
[F111]z systems have automatic or EDoes Not
accessible manual controls.
['Not Observable
ENot Applicable RECEIVE 0
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: AsP EEN9 ofll
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 ;All mechanical ventilation system ' •Complies
[F125]2 fans not part of tested and listed •Does Not
HVAC equipment meet efficacy
and air flow limits. •Not Observable
403.2 j Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
ailsystems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor ❑Not Applicable
j temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply [Not Observable
pipe. Gravity and thermos- ENot Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
41'occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 'Electric heat trace systems ❑Complies
[F129]2 comply with IEEE 515.1 or UL El Does Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
;piping.
403.5.2 Water distribution systems that 1 ❑Complies
[F130]2 have recirculation pumps that EDoes Not
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ENot Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
:water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat [Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
;individual units connected to
:three or more showers.
403.10.2 ;Readily accessible switch on ❑Complies
[F112]3 heaters for swimming pools or ❑Does Not
:permanent in-ground spas.
Switch operation does not ['Not Observable
change heater thermostat ENot Applicable
setting. Heater circuit breaker is
installed independent of switch.
:Gas-fired heaters equipped with
ignition pilots that are notJ11 I
continuously burning pilots. Jul
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: i.AFaigE.1ll0 ofll
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.10.3 Timer switches or other '❑Complies
[F119]3 1 automatic preset schedule 1L1Does Not
control method are installed on
heaters and pumps serving pools [Not Observable
and permanent ❑Not Applicable
403.10.4 Outdoor heated pools and Complies
[F120]3 outdoor permanent spas have a ElDoes Not
vapor retardant cover.
['Not Observable
'❑Not Applicable
404.1 75%of lamps in permanent EComplies
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage [Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have EComplies
[F123]3 no continuous pilot light. ❑Does Not
d' ['Not Observable
❑Not Applicable
401.3 (Compliance certificate posted. EComplies
[F17]2 EDoes Not
['Not Observable
❑Not Applicable
303.3 :Manufacturer manuals for EComplies
[F118]3 mechanical and water heating ❑Does Not
:systems have been provided.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
RECEIVED
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
12/19/2022
Project Title: 234 West Francis [Addition] Report date: 08/23/22
Data filename: Page`A1 ofll
BUILDING DLPARTMENT
2015 IECC Energy
Efficiency Certificate
Insulation Rating
Above-Grade Wall 29.00
Below-Grade Wall 28.00
Floor 15.00
Ceiling / Roof 64.00
Ductwork (unconditioned spaces):
Glass & Door Rating U-Factor SHGC
Window 0.28
Door 0.28
Skylight 0.55
Heating & Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
RECEIVED
12/19/2022
ASPEN
BUILDING DEPARTMENT