Project 234 West Francis [Historic] SEE NOTES #1 PLANS
11")Energy Code: 2015 IECC ili y
Location: Aspen, Colorado
Construction Type: Single-family 12/23/2022 .0,,,
Project Type: Alteration
Orientation: Bldg. faces 225 deg. from North FORCOIXaMiliNICE
Climate Zone: 7 (9922 HDD) justinh
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
234 West Francis Steve Ells John Spencer
Aspen, CO 81511 Selldorf Architects
860 Broadway
New York, NY 10003
2122199571
amber@bairullc.com
Compliance: Passes using prescriptive requirements for alteration projects
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or R-Value R-Value U-Factor U-Factor UA UA
Perimeter
13 - Low Slope Roof at Historic Main House: Flat
Ceiling or Scissor Truss --- --- --- --- --- --- ---
Exemption: Framing cavity filled with insulation
14-Sloped Cedar Roof: Cathedral Ceiling
--- --- --- --- --- --- ---
Exemption: Framing cavity filled with insulation
Exterior Wall at Historic [South]: Wood Frame, 16"
o.c.
--- --- --- --- --- --- ---
Orientation: Front
Exemption: Framing cavity filled with insulation
ED101: Solid Door(under 50%glazing) 18 0.320 0.320 6 6
Orientation: Front
ED108: Solid Door(under 50%glazing) 18 0.320 0.320 6 6
Orientation: Front
208: Wood Frame
Orientation: Front
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
209: Wood Frame
Orientation: Front
--- --- --- --- --- - -
Exemption: Glazing replacement in existing sash or
frame. RE/�►C- EIVED
C�
Project Title: 234 West Francis [Historic] Report clA/z1 /r-22
Data filename: Page 1 of11
ASPEN
BUILDING DEPARTMENT
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or R-Value R-Value U-Factor U-Factor UA UA
Perimeter
301: Wood Frame
Orientation: Front
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
109: Wood Frame
Orientation: Front
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
112: Wood Frame
Orientation: Front
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
113: Wood Frame
Orientation: Front
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
Exterior Wall at Historic [West]: Wood Frame, 16"
o.c.
--- --- --- --- --- --- ---
Orientation: Left side
Exemption: Framing cavity filled with insulation
ED107: Solid Door(under 50%glazing) 18 0.320 0.320 6 6
Orientation: Left side
106: Wood Frame
Orientation: Left side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
107: Wood Frame
Orientation: Left side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
108: Wood Frame
Orientation: Left side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
216: Wood Frame
Orientation: Left side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
218: Wood Frame
Orientation: Left side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
217: Wood Frame
Orientation: Left side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
Exterior Wall at Historic [North]: Wood Frame, 16"
o.c.
--- --- --- --- --- --- ---
Orientation: Back
Exemption: Framing cavity filled with insulation
114: Wood Frame
Orientation: Back
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
115: Wood Frame
Orientation: Back
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
213: Wood Frame
Orientation: Back
--- --- --- ---Exemption: Glazing replacement in existing sash or RErEivE
frame. 1 C�
Project Title: 234 West Francis [Historic] Report c lA/z /r-22
Data filename: Page 2 of11
ASPEN
BUILDING DEPARTMENT
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or R-Value R-Value U-Factor U-Factor UA UA
Perimeter
214: Wood Frame
Orientation: Back
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
215: Wood Frame
Orientation: Back
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
302: Wood Frame
Orientation: Back
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
Exterior Wall at Historic [East]: Wood Frame, 16" o.c.
Orientation: Right side
Exemption: Framing cavity filled with insulation
ED102: Solid Door(under 50%glazing) 25 0.320 0.320 8 8
Orientation: Right side
110: Wood Frame
Orientation: Right side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
111: Wood Frame
Orientation: Right side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
210: Wood Frame
Orientation: Right side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
211: Wood Frame
Orientation: Right side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
212: Wood Frame
Orientation: Right side
--- --- --- --- --- --- ---
Exemption: Glazing replacement in existing sash or
frame.
Underpinned Exterior Foundation Wall @ Historic
House: Solid Concrete or Masonry
Orientation: Unspecified 312 15.0 0.0 0.047 0.050 15 16
Wall height: 10.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
Underpinned Exterior Foundation Wall @ Historic
Cabin: Solid Concrete or Masonry
Orientation: Unspecified 238 15.0 10.0 0.032 0.050 8 12
Wall height: 9.0'
Depth below grade: 9.0'
Insulation depth: 9.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has bee signed to meet the 2015 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirem sted in the EScheck Inspection Checklist.
Callaghan Fenerty - Project Engineer 08/23/2022
Name-Title Signature Date
Project Notes:
Numerals appearing in front of roof and foundation wall assemblies correspond to architectural envelope details.
Wall assemblies are grouped by orientation and do not have corresponding numerals given the worst case
assemblies were used through out.
RECEIVED
Project Title: 234 West Francis [Historic] Report c lA/z /r-22
Data filename: Page 3 of11
ASPEN
BUILDING DEPARTMENT
REScheck Software VersionChecklist: REScheck-Web
Energy Code: 2015 IECC
Requirements: 2.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, 'Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
g building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
,construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ['Not Observable
d, Systems serving multiple ENot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions. i
302.1, Heating and cooling equipment is Heating: Heating: EComplies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr Does Not
[PR2]z on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ❑Not Observable
Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED
Project Title: 234 West Francis [Historic] Report Jae/lAfz /9g2
Data filename: Page 4 ofll
ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value. Where interior R- R- ❑Does Not table for values.
insulation is used, verification
may need to occur during [Not Observable
Insulation Inspection. Not ENot Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
6 manufacturer's instructions. [Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
t distance from top of wall.
[Not Observable
❑Not Applicable
303.2.1 ;A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO12] controls installed. ❑Does Not
.44 ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) !RECEIVED
Project Title: 234 West Francis [Historic] Report Jae/lAfzi9g2
Data filename: Page 5 ofll
ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ['Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 [Not Observable
[FR2]1 ❑Not Applicable
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or [Not Observable
taken from the default table.
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. [Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
0 AAMA/WDMA/CSA 101/I.S.2/A440 [Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
1181/1/747 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. [Not Observable
❑Not Applicable
403.3.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
qte
R-6 where < 3 inches. Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.5 :Building cavities are not used as EComplies
[FR15]3 ducts or plenums. ❑Does Not
J ['Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R R ❑Complies
[FR above 105 °F or chilled fluids ❑Does Not
below 55 °F are insulated to
3 ['Not Observable
❑Not Applicable
403.4.1 :Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
[Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
Ql ['Not Observable
❑Not Applicable
4. Automatic or gravity dampers are ❑Complies
]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
1.1 ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) RECEIVED
Project Title: 234 West Francis [Historic] Report Jae/lAfzi9g2
Data filename: Page 6 ofll
ASPEN
BUILDING DEPARTMENT
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) ECEI\/ED
Project Title: 234 West Francis [Historic] Report Jae/lAfz /9g2
Data filename: Page 7 of11
ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 ;All installed insulation is labeled '❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided. • lot
Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/z of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [Not Observable
[IN3]1 exterior,the exterior insulation
4 requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 :Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
j ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) ECEI\/Et
Project Title: 234 West Francis [Historic] Report Jae/lAfzi9g2
Data filename: Page 8 ofll
ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID_
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, j ❑ Steel ❑ Steel [Not Observable
402.2.6
[FI1]1 ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. [Not Observable
ENot Applicable
402.2.3 !Vented attics with air permeable EComplies Exception: Requirement is
[F122]2 insulation include baffle adjacent ❑Does Not not applicable.
to soffit and eave vents that
;extends over insulation. [Not Observable
, ENot Applicable
402.2.4 Attic access hatch and door R- R- EComplies
[F13]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
[Not Observable
ENot Applicable
402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
,<=3 ach in Climate Zones 3-8.
ENot Observable
, ENot Applicable
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ['Not Observable
tests,verification may need to ENot Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 EComplies
[F127]1 determine air leakage with ft2 ft2 Does Not
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ENot Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated EComplies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
ENot Applicable
403.1.1 :Programmable thermostats EComplies
[F19]2 installed for control of primary ❑Does Not
j heating and cooling systems and
:initially set by manufacturer to ['Not Observable
:code specifications. ❑Not Applicable
i
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5. Circulating service hot water qElComPlies
[F111]z systems have automatic or EDoes Not
accessible manual controls.
['Not Observable
ENot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
IR' ECEIVEb
Project Title: 234 West Francis [Historic] Report Jae/lAfzi9g2
Data filename: Page 9 ofll
ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 ;All mechanical ventilation system '❑Complies
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. [Not Observable
❑Not Applicable
403.2 j Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
ailsystems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply [Not Observable
pipe. Gravity and thermos- ENot Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
41'occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 'Electric heat trace systems ❑Complies
[F129]2 comply with IEEE 515.1 or UL El Does Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
;piping.
403.5.2 Water distribution systems that 1 ❑Complies
[F130]2 have recirculation pumps that EDoes Not
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
:water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies
mi
[F131]z tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat [Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
;individual units connected to
:three or more showers.
i .
403.10.2 ;Readily accessible switch on ❑Complies
[F112]3 heaters for swimming pools or ❑Does Not
:permanent in-ground spas.
Switch operation does not ['Not Observable
change heater thermostat ❑Not Applicable
setting. Heater circuit breaker is
installed independent of switch.
:Gas-fired heaters equipped with
ignition pilots that are not
idicontinuously burning pilots.
,' .
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 �L�
Project Title: 234 West Francis [Historic] Report c /1 /9-22
Data filename: Page 10 of11
ASPEN
BUILDING DEPARTMENT
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.10.3 Timer switches or other '❑Complies
[F119)3,1 automatic preset schedule 1L1Does Not
control method are installed on
heaters and pumps serving pools [Not Observable
and permanent ❑Not Applicable
403.10.4 Outdoor heated pools and Complies
[F120]3 outdoor permanent spas have a ❑Does Not
vapor retardant cover.
['Not Observable
'❑Not Applicable
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage [Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have EComplies
[F123]3 no continuous pilot light. ❑Does Not
d' ['Not Observable
❑Not Applicable
401.3 (Compliance certificate posted. EComplies
[F17]2 ❑Does Not
['Not Observable
❑Not Applicable
303.3 :Manufacturer manuals for ❑Complies
[F118]3 l mechanical and water heating ❑Does Not
:systems have been provided.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) ECEI\/Et
Project Title: 234 West Francis [Historic] Report c /1 /9-22
Data filename: Page 11 of11
ASPEN
BUILDING DEPARTMENT
C20y
IAEfficiency15IECC Energ Certificate
Insulation Rating •
Above-Grade Wall 0.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 0.00
Ductwork (unconditioned spaces):
Glass & Door Rating U-Factor SHGC
Window
Door 0.32
Heating & Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
RECEIVED
12/19/2022
ASPEN
BUILDING DEPARTMENT