HomeMy WebLinkAboutFile Documents.234 W Francis St.0118-2020-BRES (57) GComplianceenerated by REScheck-Web Software
Certificate
Project 234 West Francis [Historic]
Energy Code: 2015 IECC
Location: Aspen, Colorado
Construction Type: Single-family
Project Type: Alteration
Orientation: Bldg. faces 225 deg. from North
Climate Zone: 7 (9922 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
234 West Francis Steve Ells John Spencer
Aspen, CO 81511 Selldorf Architects
860 Broadway
New York, NY 10003
2122199571
amber@bairullc.com
Compliance: Average fenestration U-factor exceeds maximum
Maximum UA: 474 Your UA: 594
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or R-Value R-Value U-Factor U-Factor UA UA
Perimeter
14- Flat Roof at Historic Main House: Flat Ceiling or 71 52.0 5.0 0.022 0.026 2 2
Scissor Truss
15-Sloped Cedar Roof: Cathedral Ceiling (no attic) 2,217 58.0 7.0 0.016 0.026 35 58
Exterior Wall at Historic [South]: Wood Frame, 16"
o.c. 816 42.0 9.0 0.027 0.045 17 29
Orientation: Front
ED101: Glass Door(over 50%glazing) 24 0.500 0.320 12 8
Orientation: Front
208: Wood Frame
Orientation: Front 9 0.950 0.320 8 3
209: Wood Frame 24 0.950 0.320 23 8
Orientation: Front
301: Wood Frame 3 0.950 0.320 3 1
Orientation: Front
109: Wood Frame 30 0.950 0.320 29 10
Orientation: Front
112: Wood Frame 40 0.950 0.320 38 13
Orientation: Front
113: Wood Frame
Orientation: Front 40 RE A EIVED
0 0.320 38 13
Project Title: 234 West Francis [Historic] (4 - Report date: 02/08/22
Data filename: 02/09/2022 Page 1 ofll
ASPEN
BUILDING DEPARTMENT
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Assembly or R-Value R-Value U-Factor U-Factor UA UA
Perimeter
Exterior Wall at Historic [West]: Wood Frame, 16"
o.c. 827 42.0 9.0 0.027 0.045 19 32
Orientation: Left side
ED107: Solid Door(under 50%glazing) 18 0.500 0.320 9 6
Orientation: Left side
106: Wood Frame 16 0.950 0.320 15 5
Orientation: Left side
107: Wood Frame
Orientation: Left side 4 0.950 0.320 4 1
108: Wood Frame 30 0.950 0.320 29 10
Orientation: Left side
216: Wood Frame 12 0.950 0.320 12 4
Orientation: Left side
218: Wood Frame
Orientation: Left side 5 0.950 0.320 4 2
217: Wood Frame 25 0.950 0.320 24 8
Orientation: Left side
Exterior Wall at Historic [North]: Wood Frame, 16"
o.c. 532 42.0 9.0 0.027 0.045 12 20
Orientation: Back
114: Wood Frame 6 0.950 0.320 5 2
Orientation: Back
115: Wood Frame
Orientation: Back 40 0.950 0.320 38 13
213: Wood Frame
Orientation: Back 20 0.950 0.320 19 6
214: Wood Frame 10 0.950 0.320 10 3
Orientation: Back
215: Wood Frame
Orientation: Back 10 0.950 0.320 10 3
302: Wood Frame
Orientation: Back 7 0.950 0.320 6 2
Exterior Wall at Historic [East]: Wood Frame, 16" o.c. 795 42.0 9.0 0.027 0.045 19 32
Orientation: Right side
ED102: Solid Door(under 50%glazing) 24 0.500 0.320 12 8
Orientation: Right side
110: Wood Frame 15 0.950 0.320 14 5
Orientation: Right side
111: Wood Frame 15 0.950 0.320 14 5
Orientation: Right side
210: Wood Frame 11 0.950 0.320 11 4
Orientation: Right side
211: Wood Frame 11 0.950 0.320 11 4
Orientation: Right side
212: Wood Frame 11 0.950 0.320 11 4
Orientation: Right side
Basement Floor: Slab-On-Grade (Heated) 265 18.0 0.642 0.655 0 0
Insulation depth: 4.0'
06- Exterior Foundation Wall: Solid Concrete or
Masonry
Orientation: Unspecified
Wall height: 12.0' 3,000 R �� � .027 0.050 81 150
Depth below grade: 12.0'
Insulation depth: 11.0'
02/09/2022
ASPEN
BUILDING DEPARTMENT
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 2 ofll
Project Notes:
Numerals appearing in front of roof and foundation wall assemblies correspond to architectural envelope details.
Wall assemblies are grouped by orientation and do not have corresponding numerals given the worst case
assemblies were used through out.
RECEIVED
02/09/2022
ASPEN
BUILDING DEPARTMENT
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 3 ofll
REScheck Software VersionChecklist: REScheck-Web
Energy Code: 2015 IECC
Requirements: 2.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and '❑Complies
103.2 documentation demonstrate Does Not
[PR1]1 energy code compliance for the
,,: building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ['Not Observable
g, Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies I
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
H, Manual J or other methods ['Not Observable
Btu/hr Btu/hr
'approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 4 ofll
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[FO1]1 ❑ Unheated ❑ Unheated ElDoes Not table for values.
.0 ❑ Heated ❑ Heated [Not Observable
ENot Applicable
402.1.2 Slab edge insulation ft ft EComplies See the Envelope Assemblies
[FO3]1 depth/length. ❑Does Not table for values.
['Not Observable
1 ❑Not Applicable
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values.
• insulation is used, verification ['Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
O manufacturer's instructions. ['Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO6]1 insulation depth of burial or ❑Does Not table for values.
�, distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ['Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO controls installed. ❑Does Not
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 5 ofll
Section Plans Verified Field Verified
# Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ['Not Observable
41)
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 [Not Observable
[FR2]1 ❑Not Applicable
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or [Not Observable
taken from the default table.
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. [Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
0 AAMA/WDMA/CSA 101/I.S.2/A440 [Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
1181/1/747 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. [Not Observable
❑Not Applicable
403.3.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
qte
R-6 where < 3 inches. Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.5 :Building cavities are not used as EComplies
[FR15]3 ducts or plenums. ❑Does Not
J ['Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R R ❑Complies
[FR above 105 °F or chilled fluids ❑Does Not
below 55 °F are insulated to
3 ['Not Observable
❑Not Applicable
403.4.1 :Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
[Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
Ql ['Not Observable
❑Not Applicable
4. Automatic or gravity dampers are ❑Complies
]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
1.1 ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 6 ofll
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 7 ofll
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 ;All installed insulation is labeled '❑Complies
[IN13]2 or the installed R-values 1L1Does Not
provided. •
[Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [Not Observable
[IN3]1 exterior,the exterior insulation
4 requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 :Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
j ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 8 ofll
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID_
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood EDoes Not table for values.
402.2.2, j ❑ Steel ❑ Steel [Not Observable
402.2.6
[FI1]1 ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. [Not Observable
ENot Applicable
402.2.3 !Vented attics with air permeable EComplies Exception: Requirement is
[F122]2 insulation include baffle adjacent ❑Does Not not applicable.
to soffit and eave vents that
;extends over insulation. [Not Observable
j ENot Applicable
402.2.4 Attic access hatch and door R- R- EComplies
[F13]1 insulation >_R-value of the EDoes Not
adjacent assembly.
[Not Observable
ENot Applicable
402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
I<=3 ach in Climate Zones 3-8.
ENot Observable
j ENot Applicable
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 EComplies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 EDoes Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ['Not Observable
tests,verification may need to ENot Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 EComplies
[F127]1 determine air leakage with ft2 ft2 Does Not
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated EComplies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
ENot Applicable
403.1.1 :Programmable thermostats EComplies
[F19]2 installed for control of primary ❑Does Not
;heating and cooling systems and
:initially set by manufacturer to ['Not Observable
:code specifications. ❑Not Applicable
i
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. EDoes Not
ENot Observable
❑Not Applicable
403.5. Circulating service hot water qElComPlies
[F111]2 systems have automatic or EDoes Not
accessible manual controls.
['Not Observable
i ENot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 9 ofll
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 ;All mechanical ventilation system '❑Complies
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. [Not Observable
❑Not Applicable
403.2 j Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
ailsystems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply [Not Observable
pipe. Gravity and thermos- ENot Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
41'occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 'Electric heat trace systems ❑Complies
[F129]2 comply with IEEE 515.1 or UL El Does Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
;piping.
403.5.2 Water distribution systems that 1 ❑Complies
[F130]2 have recirculation pumps that EDoes Not
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
:water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies
mi
[F131]z tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat [Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
;individual units connected to
:three or more showers.
i .
403.10.2 ;Readily accessible switch on ❑Complies
[F112]3 heaters for swimming pools or ❑Does Not
:permanent in-ground spas.
Switch operation does not ['Not Observable
change heater thermostat ❑Not Applicable
setting. Heater circuit breaker is
installed independent of switch.
:Gas-fired heaters equipped with
ignition pilots that are not
.41 continuously burning pilots.
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 10 ofll
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.10.3 Timer switches or other '❑Complies
[F119]3 1 automatic preset schedule 1L1Does Not
control method are installed on
heaters and pumps serving pools [Not Observable
and permanent ❑Not Applicable
403.10.4 Outdoor heated pools and Complies
[F120]3 outdoor permanent spas have a ElDoes Not
vapor retardant cover.
['Not Observable
'❑Not Applicable
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage [Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have EComplies
[F123]3 no continuous pilot light. ❑Does Not
d' ['Not Observable
❑Not Applicable
401.3 (Compliance certificate posted. EComplies
[F17]2 EDoes Not
['Not Observable
❑Not Applicable
303.3 :Manufacturer manuals for ❑Complies
[F118]3 l mechanical and water heating ❑Does Not
:systems have been provided.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: 234 West Francis [Historic] Report date: 02/08/22
Data filename: Page 11 ofll
L2015 IECC Energy
i( Efficiency Certificate
Insulation Rating •
Above-Grade Wall 51.00
Below-Grade Wall 33.00
Floor 18.00
Ceiling / Roof 65.00
Ductwork (unconditioned spaces):
Glass & Door Rating U-Factor SHGC
Window 0.95
Door 0.50
Heating & Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments