HomeMy WebLinkAboutFile Documents.234 W Francis St.0118-2020-BRES (60) Fr"- R EG
R E S O U R C E
_Ai
E N G I N E E R I N G
GROUP
Korbinian Kainz
860 Broadway, 2nd floor
New York, NY 10003
T 212.219.9571
korbinian@selldorf.com November 30, 2021
Regarding: 234 W. Francis Special Inspections
Korbinian:
This letter is regarding the special inspection requirements at 234 W Francis Avenue, Aspen, CO.
The following special inspections must be performed in accordance with IRC Section 1705:
Special Inspections Program
Project Name: 234 W Francis
Building Jurisdiction: City of Aspen, CO
Job #: 2968
All inspections shall comply with the requirements of City of Aspen, IRC 2015, and the project
specifications. If in any case a conflict arises between governing documents the most stringent
requirements shall apply.
Reinforced Concrete:
1. Reference Specification 3300 for testing of placed concrete and verification of mix design
and rebar mill certifications.
2. Placement of rebar prior to pouring concrete shall be inspected per city regulations.
Structural Steel:
1. Periodic Inspections of:
a) Material verification of high strength bolts
b) Bolted bearing connections
c) Single pass fillet welds <=5/16"
d) Inspection of fabricator and fabrication facilities
Sincerely, r OPpDO L/OFF�1
i O�..•oODSp�...o'1,
Dodson Harper, PE ; ;(� 9 4,
•: 45610 Ti
i ml
CV •��i
, Fs•• . �
\IONAL&--` : RECEIVED
0
Consulting Engineers • Mechanical • Structural • Energy 1 2 8 2 2 2
Crested Butte&Golden Colorado • reginc.com ASPEN
BUILDING DEPARTMENT