HomeMy WebLinkAboutFile Documents.234 W Francis St.0118-2020-BRES (66) Eng i neeri ng3_234 W Francis_0118-2020-B RES 40.DrainageReport.234WFrancis.2021.10.04.pdf(4) Page: 52 Author: pjm There is a discrepancy in areas There ePe eyinareas here. How is PR1 = .158 acres sr here.58ecrHow lbPR1= File Name: 40.DrainageReport.234WFrancis.2021.10.04.pdf but the area used to calculate .158 acres but the area used to calculate The area shown in the drywell detention the drywell detention volume be / the drywell decent on °�a=A. res?AI of PR, volume is the tributary impervious area for o96 ages. An of PR1 drains to °P°�'� ren drains to the drywell. rn� .,m Please address. the volume calc. This line has been the drywell. Please address. - removed per detention analysis below. . Page: 55 71 __ ;I i Drywell detention volume 80 _I'll IL' Author: pjm calculations need to follow IllEE File Name: 40.DrainageReport.234WFrancis.2021.10.04.pdf Chapter 5 of the URMP for the ... .. .. , Detention volume has been revised and FAA method of historic calculated per URMP section 5.6.1. detention. Follow the process �Wa, Detention volume calculations have been outlined in section 5.m1 of the URMP. Note the example added to the hydrologic calculations following section 5.6.1 uses the appendix. incorrect coefficients to calculate I in equation 5-1, however the process is correct.These calculations needs to be provided in the report. Using MHFD detention spreadsheets, I calculated detention as 162c which can be accommodated in the drywell, the controlled outlet needs to be designed. Provide calcs on how the runoff will be controlled to historic rate of 0.23cfs. �. mmmm Page: 55 mm®mmm Author: pjm The runoff volume equation Immo File Name: 40.DrainageReport.234WFrancis.2021.10.04.pdf Bete tion volume for either full bove does not calculate TeOae1P°�kill Detention volume has been revised and detention or detention to historic calculated per URMP section 5.6.1. release rate, it calculates the inflow volume for detention. Ba"°° Detention volume calculations have been a°„�,,,,,aapo,.4 added to the hydrologic calculations It looks like I and P were mixed appendix. up in the calculations above for drywell volume.The result of this equation should be 0.9 of full detention (based on the runoff coefficient)which is roughly 380cf. P= 1.23", I =6.33"per equation 2-1 and the table above. .) =7484.51 Velocity(ft/s) Page: 66 =2.00 Wetted Perim This doesn't match page 9 for =0.030 Crit Depth,Ye Author: pjm Top ii;th(ft) File Name: 40.DrainageReport.234WFrancis.2021.10.04.pdf onsite basin runoff. Total runoff KnownO is .74 or PR1 is .65 ;) =0.65 This swale carries overflow from basin This doesn't match PR-1 0.65 cfs. page 9 for onsite f basin runoff.Total RECEIVED �� /E runoff is.74 or PR1 is ■ ) 65 Section I L 01/28/2022 ASPEN BUILDING DEPARTMENT 90.PERMIT.CIVIL.234WFrancis.2021.10.04.pdf(4) >n°" I . t / Page: [2] C200 GRADING& EROSION CONTROL PLAN 'rr 7 I a,e 3 Author: m Label CB-1 swale on the civil 1 File Name: 90.PERMIT.CIVIL.234WFrancis.2021.10.04.pdf sheets. atiEVAwawa imi ta ,4'lass, < pj ,�,��li ,, PROPOSED CB-1 swale callout has been added. Ecs.+>mmegoorii CABIN Fir MAIN FF:7885.69 Ili /�, i of 4„,„. ,1 A '' 1 "1rillil % •,.v�1 ® I Age 1 Page: [2] C200 GRADING& EROSION CONTROL PLAN I ] Since full detention cannot be a. \ .� w ; , Author: pjm. accommodated in the drywell, t ,, > „\i File Name: 90.PERMIT.CIVIL.234WFrancis.2021.10.04.pdf this outlet needs to be controlled The 100-yr FAA detention volume is to contain the 100 yr FAA calculated to be 232-cf. The drywell detention volume and release at --- „. the historic, undeveloped rate provides 373-cf volume and releases at per the FAA method. IM_ or below the historic rate. A Hydrocad .� 1 m analysis of the drywell is included in the Drainage cannot be directed to a neighboring property unless at appendices. The 100-yr release is the historic rate. If above the 0.08cfs, which is below the historic rate historic rate, conveyance to the of 0.23cfs. City's system needs to be shown via grading/necessary calculations, etc. I Page: [4] C301 STORM PLAN &PROFILE Call out rim elevations of all WE EN .11.1 A:44+1: 88 '880 Author: pjm T.eIS� �E File Name: 90.PERMIT.CIVIL.234WFrancis.2021.10.04.pdf inlets to confirm CB-1 is the low 8840 point for overflow discharge and NV � 787 8 787E The storm structure table on sheet C300 lists to verify design is installed per Call out rim elevations __ of all inlets tocpoint plan during the asbuilt reivew. for overflow low point rim elevations for all storm structures. CB-1 for overflow discharge T872 nstaledperplaaig"'s rim elevation is confirmed as the lowest. == during the mive T&68 Downspout riser rim elevations have been I added to sheet C301. Page: [7] C401 MISCELLANEOUS DETAILS AE ESSE P Remove the overflow pipe that --atehillignia7CeTTMAuthor: pjm File Name: 90.PERMIT.CIVIL.234WFrancis.2021.10.04.pdf originally connected to the storm ° °�®� A main in Francis St.This �47l ilillnlww` �� Overflow pipe has been removed. connection is no longer '�: proposed. s I Remove the overflow ■ pipe that originally VT*. u. Sconnected to the SECTION'SITU RUST El storm main in Francis RECFANT Ads i St.This connection is �xATcx vnTx umLE HANDLE � no longer proposed. SE__ 4S"MIN PRECAST '12' 4,GRAVEL e ---PERFORATED PCC RING R ORATION RECEIVED 01/28/2022 ASPEN BUILDING DEPARTMENT