Loading...
HomeMy WebLinkAboutFile Documents.507 E Main St.0053-2024-BRES (6) APPLICATION ACCEPTED DATE: 2024-05-28 PERMIT NUMBER: 0053-2024-BRES Field Plan Set Must Be Printed In Color 0 4040p;0 40 COMMUNITY DEVELOPMENT DEPARTMENT 01 /� CITY OF A g% ASPEN BUILDING PERMIT COVERSHEET 41 CITY OF ASPEN These plans mu's e�ept at the building site or inspection PROPERTY INFORMATION delays may occur.Construction shall conform to these plans.All changes shall be approved by ADDRESS: 507 W MAIN ST C201 UNIT: Aliging official. PARCEL ID: 273512449025 LEGAL DESCRIPTION: CHRISTIANA ASPEN CONDO OWNER: WELLES PETER S&SONDRA T General Electrical Requirements 100%of lamps in PERMIT CONTRACTOR: Berry Design Works Any areas affected by the renovation must be brought permanently installed light SEPARATE PERMITS ARE up to the current electrical code including: fixtures must be high efficacy REQUIRED FOR ELECTRICAL, tamperproof receptacles(NEC 406.12), ECC R404.1 PLUMBING, SPRINKLERNWORK R ground-fault circuit interrupter protection(NEC 210.8), arc-fault protection(NEC 210.12), SMOKE ALARMS AND DESCRIPTION OF WORK UPGRADE BEDROOM/BATHROOM IN KIND. receptacle spacing(NEC 210.52)etc. CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN 1.REMOVE DOOR/HEADER FOR CURRENT BEDROOM ENTRY MUNICIPAL CODE 8.15 FIRE 1 IT should be known that this review shall 2.REMOVE EXISTING CLOSET(PRESUMED NON LOAD BEARING WALL..see structural letter) not relieve the applicant of their responsibility to comply with the SPRINKLERS requirements of the City of Aspen Municipal Code.Pursuant to Sec.26.104.050,any permit or approval 3.SEAL CURRENT BATHROOM DOOR AND ADD NEW DOOR/DOORWAY IN BATHROOM issued in error or otherwise not in REQUIRED conformity with the requirements of this Title,shall be void.Similarly,any permit or approval issued in reliance upon or as a result of,a materially false 4.ADD ONE SINK IN BATHROOM statement or representation made in the process of obtaining the permit or development approval shall,likewise, be void.Any person having received a void or voidable permit or approval 5.ADD DOOR/DOORWAY TO BEDROOM shall not be relieved from having to comply with all applicable terms and conditions of this Title and the City shall not be estopped from fully enforcing same. 5.REPLACE CARPET WITH HARDWOOD FLOOR EV L� STRUCTURAL VEgIEVIBIS I 1040 MAIN STREET•CARBONDALE,C00061623•(9701 510-07 7 3 vw�v.evolvestruct.cam 04/16/24 I)) USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? Yes May 1,2024 FORCOOECOMPLANCE Chris Berry SMont PO Box 10544 Aspen,Colorado 81611 CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 R (415)999-1456 c berry@mac.com RE: 507 W Main BUILDINGREQUIRED SPECIAL TYPE(IRC) soy West Main Street Aspen,Colorado 81611 INSPECTIONS ESD Project#:24.035C Chris, CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table As requested,we have reviewed the potential structural impact of the proposed remodel at the location noted above.Our review is based upon April 23,2024 email showing existing architectural drawings with proposed modifications highlighted.The current proposed scope of work includes removal of an interior wall and an OCCUPANCY GROUP(IBC) R-2 WORK CHANGES BUILDING No interior door and its header. FOOTPRINT? Once demolition can begin,the wall and ceiling finishes in these areas,shall be at least partially removed in order to verify the potential effects to the existing structure.We shall be contacted to visually observe the conditions and will then work to define the structural impact of the proposed.This shall be done prior to CODE EDITIONS 2021 IEBC TOTAL SPA SQ.FT. proceeding with the removal or modification of any framing members,while also allowing sufficient time for the scope of structural engineering to be defined and completed.Please note,no interior partition walls nor ceiling framing shall be removed or modified prior to our observation.Furthermore,if any drywall or other finishes are showing signs of movement or moisture,such as cracking,bubbling,discoloration or spalling,we should be notified to observe conditions prior to the removal of any finishes. OTHER CODE EDITIONS 2021 IBC,2021 IMC,2021 IPC TOTAL SNOWMELT SQ.FT. The proposed structural modifications may require an analysis of both the gravity and lateral systems,tracing gravity and lateral load paths through the building,possibly affecting and requiring structural work in areas of the building outside of the proposed architectural scope. HISTORIC PROPERTY? Yes TOTAL POOL SQ.FT. Please note,that verifications and subsequent recommendations may have a significant impact on the project direction and schedule.Should you have any further questions regarding this matter,please feel free to contact our office.We look forward to working with you through the completion of your remodel. Sincerely, FIRE SPRINKLER EXISTING? Yes Evolve Structural Design LLC Reviewed By: 00,00 L/c;h,, 55448 riri i '1 ►L RECEIVED Jonathan Steurer,P.E. Dustin Wheatly,P.E. Project Engineer Principal-Senior P.M. 05/02/2024 05/28/2024 ASPEN BUILDING DEPARTMENT