HomeMy WebLinkAboutFile Documents.617 E Cooper Ave.0007-2023-BRES (8) APPLICATION ACCEPTED DATE 2023-01-18 PERMIT NUMBER: 0007-2023-BRES Field Plan Set Must Be Printed In Color ,l 1
CITY OF ASPEN \ 'I0I 1
COMMUNITY DEVELOPMENT DEPARTMENT PERMIT NO.0007-2023-BRES
CITY OF
BUILDING PERMIT COVERSHEET dig Ili OWNER DPG INVESTMENT PROPERTIES LI ASPEN
CITY OFASPEN
ADDRESS 617 E COOPER AVE 207
These plans muus ekeept at the
PROPERTY INFORMATION
PARCEL ID 273718243104 building site or inspection
ADDRESS 617 E COOPER AVE 207 UNIT delays may occur.Construction
PARCEL ID: 273718243104 LEGAL DESCRIPTION: ASPEN SQUARE IAL REFERENCES FROM 2015 IBC shall conform to these plans.All
CEILING RADIATION DAMPERS REQUIRED CV/CS=crawl space ventilation sec.1203.4. 18"x 24"access required changes shall be approved by
OWNER DPG INVESTMENT PROPERTIES LLC Ducts and air transfer openings penetrating the ceiling of 1209.1
a fire rated ceiling assembly must be protected with a ing official.
PERMIT CONTRACTOR: JANCKILA CONSTRUCTION INC listed ceiling radiation damper.This includes bathroom EE=emergency escape required sec 1030
exhaust fans.(IBC 717.6.2) EU=enclosed usable space under stairs shall 1-hr construction or stair
enclosure rating.No access from stair enclosure.W gypsum permitted for
stairs inside a single dwelling unit.1011.7.3. SEPARATE PERMITS ARE
FIRE RATED HATS REQUIRED RV=roof and rafter ventilation required 1203.2 REQUIRED FOR ELECTRICAL,
Where floor/ceiling or roof/ceiling A=Attic Access 20"x 30"1209.2
DESCRIPTION OF WORK Partial interior remodel.Removing a soffit and removing the door to the adjacent room.Restore separation assemblies are required to have a SA=smoke alarm(NFPA 72)required sec 907.2.11 PLUMBING,MECHANICAL,OR
between units. fire-resistive rating,recessed fixtures shall CO=carbon monoxide detector req.per Aspen Municipal Code 8.15 FIRE SPRINKLER WORK
be installed such that the required fire SG=safety glazing required sec 2406
resistance will not be reduced(IBC 714.4.2) V=mechanical ventilation required sec 1203.1&IMC 403(bath fans and
whole house ventilation) SMOKE ALARMS AND
GR=guards,42"min ht,4"max opening.Guards within dwelling unit 36"min CARBON MONOXIDE
ht sec 1015 DETECTORS REQUIRED
HR=handrails 34"-38"ht sec 1014 THROUGHOUT DWELLING
USE OF BUILDING Multi-FamilyFIRE SPRINKLER REQUIRED? Yes DS=Draft stopping/fre blocking 718 UNIT PER CITY OF ASPEN
RD=Roof drainage 1503.4
STC=Sound transmission class not less than 50 at dwelling separations,sec MUNICIPAL CODE 8.15
1207
SI=Stairway Illumination 1205.4
CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 PD=protect against decay,sec 2304.12
REFERENCES FROM 2015 IMC
DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM It should be known that this review shall
AS=access and service space for maintenance req'd,sec 306
REQUIRED SPECIAL MA=make up air required if hood exhausts greater than 400 CFM,sec 505.2 not relieve the applicant of their
BUILDING TYPE(IRC) ET=exhausts terminate 3'from prop line and openings,10'from intakes, responsibility to comply with the
INSPECTIONS 501.3.1 requirements of the City of Aspen
IT=intake openings 10'from lot line&contaminant sources(vents,streets), Municipal Code.Pursuant to
401.4
D=fasten and seal all ductwork per 603.9 Sec.26.104.050,any permit or approval
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE REFERENCES FROM 2015 IFGC issued in error or otherwise not in
DV=direct vent req'd,sec 303.3 conformity with the requirements of this
CA=combustion air not taken from bedrooms,bathrooms or Title,shall be void.Similarly,any permit
storage sec 303.3 or approval issued in reliance upon or
OCCUPANCY GROUP(IBC) R-2 WORK CHANGES BUILDING No OD=outdoor appliances must be listed for outdoor use,sec 303.E as a result of,a materiallyfalse
FOOTPRINT? REFERENCES FROM 2015 IECC
F=new or replacement fenestration shall not exceed 0.28 U-factor,NFRC statement or representation made in
label required,Ordinance 40,2016 the process of obtaining the permit or
L=75%of lamps in permanently installed lights must be high efficacy,sec development approval shall,likewise,
CODE EDITIONS 2015 IBC TOTAL SPA SCUT. R404.1 be void.Any person having received a
SE=Continuous air barrier required;all exterior joints,cracks,and holes to b void or voidable permit or approval
caulked,gasketed,sealed,table R402.4.1.1
REFERENCES FROM 2014 NEC shall not be relieved from having to
EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26 comply with all applicable terms and
OTHER CODE EDITIONS TOTAL SNOWMFLT SQ.FT. conditions of this Title and the City shall
not be estopped from fully enforcing
• - same.
HISTORIC PROPERTY? No TOTAL POOL SQ.FT.
EVENS--b)
sophiev
FIRE SPRINKLER EXISTING? Yes
01/20/2023
i ZONING
GA FILE NO. FC 5120 I GENERIC 1 HOUR 39-to-54-STC GA FILE NO.WP 3380 GENERIC 1 HOUR 40 to 44 STC FIRE
WOOD JOISTS,GYPSUM WALLBOARD,RESILIENT CHANNELS, FIRE SOUND WALLBOARD,WOOD STUDS FIRE f, SOUND SPRINKLERS
GLASS FIBER INSULATION One layer 5/i type X gypsum wallboard or gypsum veneer base applied parallel or at right l 1 I I
, .. . REQUIRED
One layer 1/2"type X gypsum wallboard or gypsum veneer base applied at right angles to angles to each side of 2 x 4 wood studs 16'o.c.staggered 8"o.c.on 2 x 6 wood plates
I
resilient furring channels 24"o.c.with 1"Type S drywall screws 8"o.c.at ends and 12" with 6d coated nails,VW long,0.0915"shank,+!i heads,T o.c. Il Il x rr Il I J l
o.c.at intermediate furring channels.Gypsum board end joints located midway between Joints staggered 24'on opposite sides.Horizontal bracing required at mid height.(LOAD-
continuous channels and attached to additional pieces of channel 64"long with screws ' BEARING) REVIEWE 1
8"o.c.Resilient furring channels applied at right angles to 2 x 10 wood joists 16"o.c. , 02/16/2023with 6d coated nails, 17/a"long, 0.085"shank, 1/4"heads, two per joist.Wood joists
supporting s/e"interior plywood with exterior glue subfloor and 3/a"particle board,1.5 psf. PORCOIkCUMHJNIGE
31/2"glass fiber insulation batts,0.7 pcf,friction fit in joist cavities supported alternately Approx.Ceiling Thickness: 73/4" linzhid
every 12"by wire rods and resilient furring channels. Weight: 2 psf Approx.Weight 8 psf
with insulation stapled to joists. Fire Test: FM FC-181,8-31-72 Fire Test: See WP 3605
(UL R1319-4,-8,6-17-52;
UL R2717-39,1-20-66;
IIC 6 T....4. (73 C&P) UL R3501-52,3-15.66,
UL Design U305;
ULC Design W301);
UL R4024,10-31-68
alifornia Office of Noise Control
Sound Test: NRCC TL-93-254.
IRC-IR-761,3/98
lest INamR'r IV anther
Sketch Brief Description Year
Frequencies Tested California Office of Noise Control 50 - 19
Source of Data STC - -
. ,.. Laboratory STC Section
I. 2, 4. 5. 6. 1. min 2x10 joists, 16"o.c. ... Geiger and Hamme 51 2.1.1.2.1.2 Test Number Numbe
2. 19/32"tongue and groove plywood. APA-1ST Sketch • Brief Description Year
1971 • Frequencies Tested
16f Source of Data
4. resilient channels,24"o.c. American Plywood -- -_
----- - --- 5. 5/8"gypsum board screwed 12"o.c. Assn.
1. 2. 3. I. 2x4 Studs spaced 16'o.c.and staggered ... Geiger and Hamme 51 1.2.3.1.4
6. min 1'thick sound attenuation blanket. 8"o.c.on 2x6 plates. OC-SFC
2. 1/2'gypsum board screwed I2'o.c. 1972
- 3. 3 I/1'thick sound attenuation blankets 16f
Ir a�t�� "�i 1. '� I■S1' in both stud cavities. Owens/Corning
.T MT MR ate I NI.JY ! i1:f1L� 1A, ,� !f Fiberglas