HomeMy WebLinkAboutFile Documents.617 E Cooper Ave.0008-2023-BRES (10) APPLICATION ACCEPTED DATE: ?CP3-i11-:li PERMIT NUMBER: 0008-2023-BRES Field Plan Set Must Be Printed In Color ,�1�;
CITY•OF ASPEN ;I4A4
COMMUNITY DEVELOPMENT DEPARTMENT 1 • '►,. PERMIT NO 0008-2023-BRES
CITY OF
BUILDING PERMIT COVERSHEET ����� OWNER DPG INVESTMENT PROPERTIES LI ASPEN
CITY OFASPEN/ ADDRESS 617 E COOPER AVE 208
..
PROPERTY INFORMATION PARCEL ID 273718243103 These plans must De Kept at the
building site or inspection
ADDRESS: 617E COOPER AVE 208 UNIT delays may occur.Construction
PARCEL ID: 273718243103 LEGAL DESCRIPTION: ASPEN SQUARE REFERENCES FROM 2015 IBC shall conform to these plans.All
OWNER! DPG INVESTMENT PROPERTIES LLC CEILING RADIATION DAMPERS REQUIRED CV/CS=crawl space ventilation sec.1203.4. 18"x 24"access required changes shall be approved by
Ducts and air transfer openings penetrating the ceiling of 1209.1 Ifiliging official.
PERMIT CONTRACTOR: JANCKILA CONSTRUCTION INC a Ore rated ceiling assembly must be protected with a EE=emergency escape required sec 1030
listed ceiling radiation damper.This includes bathroom EU=enclosed usable space under stairs shall be 1-hr construction or stair
exhaust fans.(IBC 717.6.2) enclosure rating.No access from stair enclosure.'."gypsum permitted for
stairs inside a single dwelling unit.1011.7.3. SEPARATE PERMITS ARE
RV=roof and rafter ventilation required 1203.2
FIRE RATED HATS REQUIRED A=Attic Access 20"x 30"1209.2 REQUIRED FOR ELECTRICAL,
DESCRIPTION OF WORK Full interior remodel.Replacing all appliances and plumbing fixtures.Adjusting the layout of the bathroom and Where floor/ceiling or roof/ceiling SA=smoke alarm(NFPA 72)required sec 907.2.11 PLUMBING,MECHANICAL,OR
assemblies are required to have a CO=carbon monoxide detector req.per Aspen Municipal Code 8.15 FIRE SPRINKLER WORK
closet area.All new finishes.Infill door between units and restore separation. fire-resistive rating,recessed fixtures shall SG=safety glazing required sec 2406
be installed such that the required fire V=mechanical ventilation required sec 1203.1&IMC 403(bath fans and
resistance will not be reduced(IBC 714.4.2) whole house ventilation) SMOKE ALARMS AND
GR=guards,42"min ht,4"max opening.Guards within dwelling unit 36"miq CARBON MONOXIDE
ht sec 1015 7 DETECTORS REQUIRED
HR=handrails 34"-38"ht sec 1014 THROUGHOUT DWELLING
DS=Draft stopping/fire blocking 718 UNIT PER CITY OF ASPEN
USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? Yes RD=Roof drainage 1503.4
STC=Sound transmission class not less than 50 at dwelling separations,sec MUNICIPAL CODE 8.15
1207
SI=Stairway Illumination 1205.4
PD=protect against decay,sec 2304.12
CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 REFERENCES FROM 2015 IMC
DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM
_ AS=access and service space for maintenance req'd,sec 306 It should be known that this review shall
MA=make up air required if hood exhausts greater than 400 CFM,sec 505.2 not relieve the applicant of their
REQUIRED SPECIAL ET=exhausts terminate 3'from prop line and openings,10'from intakes, responsibility to comply with the
BUILDING TYPE IRC) 50T=1 intake openings 10'from lot line&contaminant sources(vents,streets), Municipal Code.Pursuant to
INSPECTIONS requirements of the City of Aspen
, 401.4
D=fasten and seal all ductwork per 603.9 Sec.26.104.050,any permit or approval
REFERENCES FROM 2015IFGC issued in error or otherwise not in
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE DV=direct vent req'd,sec 303.3 conformity with the requirements of this
CA=combustion air not taken from bedrooms,bathrooms or Title,shall be void.Similarly,any permit
storage sec 303.3 or approval issued in reliance upon or
OD=outdoor appliances must be listed for outdoor use,sec 303.6 as a result of,a materiallyfalse
WORK CHANGES BUILDING REFERENCES FROM 20151ECC
OCCUPANCY GROUP(IBC) R-2 FOOTPRINT? No F=new or replacement fenestration shall not exceed 0.28 U-factor,NFRC statement or representation made in
label required,Ordinance 40,2016 the process of obtaining the permit or
L=75%of lamps in permanently installed lights must be high efficacy,sec development approval shall,likewise,
R404.1 be void.Any person having received a
CODE EDITIONS 2015 IBC TOTAL SPA SQ.FT. SE=Continuous air barrier required;all exterior joints,cracks,and holes to be or void or voidablepermit approval
caulked,gasketed,sealed,table R402.4.1.1
REFERENCES FROM 2014 NEC shall not be relieved from having to
EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26 comply with all applicable terms and
conditions of this Title and the City shall
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT, not be estopped from fully enforcing
same.
HISTORIC PROPERTY? No TOTAL POOL SO.FT. i��������
NEVsophie V 0
tt sophiev
01/20/2023
FIRE SPRINKLER EXISTING? Yes ZONING
r,._ 5, c�TC i GA FILE NO.WP 3380 GENERIC 1 HOUR 40 to 44 STC FIRE
GA FILE NO. FC 5120 I GENERIC 1 HOUR w cv�sic
WOOD JOISTS,GYPSUM WALLBOARD,RESILIENT CHANNELS, FIRE -SOUND- , SOUND SPRINKLERS
-
GYPSUM WALLBOARD,WOOD STUDS FIRE ,
GLASS FIBER INSULATION One layer 5/i type X gypsum wallboard or gypsum veneer base applied parallel or at right .• . t , . . ' -, REQUIRED
One layer Vs"type X Yp drywall - angles to each side of 2 x 4 wood studs 16"O.C.staggered 8"O.C.on 2 x 6 wood plates + T
ygypsum wallboard or gypsum veneer base applied at right angles to with 6d coated nails,17/a"long,0.0915"shank,1/i heads,7'o.c.
resilient furringchannels 24"o.c.with 1"Type S d wall screws 8"o.c.at ends and 12"
o.c.at intermediate furring channels.Gypsum board end joints located midway between r ? I Joints staggered 24"on opposite sties.Horizontal bracing required at mid height.(LOAD- / 11 1\/I [� jEWEt'�i continuous channels and attached to additional pieces of channel 64"long with screws J1x\\ I IICC/X\VII L(1�t1`)!02/16/2023
8"o.c.Resilient furring channels applied at right angles to 2 x 10 wood joists 16"o.c. . - 4 1(
IV
with 6d coated nails, VA"long,0.085"shank, 1/4"heads, two per joist.Wood joists FORC0 tC0ilitiN ICE
supporting 5/a'interior plywood with exterior glue subttoor and a/a"particle board,1.5 psf. linzhid
31/2"glass fiber insulation batts,0.7 pcf,friction fit in joist cavities supported alternately Approx.Ceiling Thickness: 75/4"
every 12"by wire rods and resilient furring channels. Weight: 2 psf Approx.Weight: 8 psf
with insulation stapled to joists. Fire Test: FM FC-181,8-31-72 Fire Test: See WP 3605
Ce.ft'id Test: G&l I OC 3MT,10 13-71 (UL R1319-4,-6,6;17.52;
UL R2717-39,1-20-66;
IIC 6 Tv-A. (73 C&fy UL R3501-52,3-15.66,
UL Design U305;
ULC Design W301);
UL R4024,10-31-68
;California Office of Noise Control t Sound Test: NRCC TL-93.254,
seas reumoes NUmyer IRC-IR-761,3/98
Sketch Brief Description Year
Frequencies Tested California Office of Noise Control 50 19
Source of Data STC -
. ,.. Laboratory STC Section
1, 2. 4. 5. 6. 1. min 2x10 joists, 16"o.c. ... Geiger and Hamme 51 2.1.1.2.1.2 Test Number Nurnbe
2. 19/32"tongue and groove plywood. APA-tST Sketch Brief Description Year
1971 Frequencies Tested
16f Source of Data
4. resilient channels,24"o.c. American Plywood _ _ -, rs= - -___-_ -
5. 5/8'gypsum board screwed 12-o.c. Assn. 1. 2. 3. I. 2x4 Studs spaced 16"o.c.and staggered Geiger and Hamme Sl 1.2.3.1.4
6. min I"thick sound attenuation blanket. 8"o.c.on 2x6 plates. OC.SFC
2. 1/2'gypsum board screwed 12'o.c. 1972
- 3. 3 1/2'thick sound attenuation blankets 16f
1l �. ���T '�. rwizIn both stud cavities. Owens/Corning
7 i Whis}aT Ta Ice Me!oa! IMt If f (JI.jlj "� Fiberglas