Loading...
HomeMy WebLinkAboutFile Documents.301 E Hyman Ave.0027-2024-BCOM (4) SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ'S All snowmelt systems shall meet the following: - Any portions in the Right of Way must be on a separate zone. A ROW permit NOTES: and Permanent Encroachment License are required. - R10 insulation shall be installed under the area to be snowmelted or R5 insulation 1. EXISTING SIDEWALK TO REMAIN, shall be installed under the slab edges.(Ordinance 11 Series 2011) Automatic controls installed for system shut off when pavement temperature is above FIELD VERIFY AND COORD STAIR& 50°F and no precipitation is falling.(2015 IECC R403.9 and C403.2.4.5) SIDEWALK INTERFACE TO MINIMIZE - Automatic or manual controls installed for system shut off when outdoor temperature DIFFERENTIAL SETTLEMENT is above 40°F. (2015 IECC R403.9 and C403.2.3.5) POTENTIAL. - Inspection by testing hydrostatically at 1.5 times max system design pressure,but not 2. CONCRETE STAIRS ON GRADE, RISE& less than 100psi,for 15 minutes. (2015 IMC 1208.1) RUN PER ARCH. 3. #4 NOSING BARS. 4. #4 @ 12"o.c. EACH WAY. 5. 1/2" EXPANSION MATERIAL. 6. EXISTING SIDEWALK TO REMAIN. 7. SUITABLE COMPACTED SUB-GRADE. (1) (2) (3) • . • coo 41 C) • • III 111 11 (4) (5) =1I (6) I�- -(7) I o • v • v • =1 it _ORp DO L/CF‘ ;�J (Pi EVIEWIE I)) ''• ►l 35 0: °_ 10/21/2024 •o'. . 5 . . •� denism 1 . ••••••• ���s\ONAL EN� 05/21/2024 SSK- CONCRETE STAIRS ON GRADE 0006000 Project 24.037 MTCG Prospector Condos Entry Stair Date 5.21.2024 STRUCTURAL 301 E Hyman Avenue Drawn SL Mounlainlbwn Consulting Group, Aspen, Colorado 8 161 I Sheet E C E N sieve®PC Box o 0 g.00m 1621 nsa ,}� w pa a 1577.ea:an.co niszi N /V',~/`/3f/' Www.mounrainrowncg.com ' /2 0 2 4 ASPEN j BUILDING DEPARTMENT