HomeMy WebLinkAboutFile Documents.315 Dean St.0024-2024-BCOM (7) Field Plan Set Must Be Printed In Color �►0
APPLICATION ACCEPTED DATE: 1 2024-05-09 PERMIT NUMBER: 0024-2024-BCOM 4140
0 Construction Mitigation: No occupation of the City Right r
COMMUNITY DEVELOPMENT DEPARTMENT #0 CITY OF ASPEN CITY OF
��►�►'� of Way will be permitted without a Temporary ASPEN
BUILDING PERMIT COVERSHEET CITY��� Encroachment License, on street parking shall be PERMIT N0.0024-2024-BOOM
reserved by the Contractor through the Parking OWNER ASPEN OWNER LLC These plans muus e.M ptatthe
PROPERTY INFORMATION Department. ADDRESS. building site or inspectionConstr
315E DEAN ST delays mayoccur.Construction
ADDRESS: 315 E DEAN ST UNIT PARCEL ID shall conform to these plans.All
PARCEL ID: 273718285032 LEGAL DESCRIPTION: ASPEN RESIDENCE CLUB&HOTEL 273718285032 changes shall be approved by
OWNER: ASPEN OWNER LLC Aiking official.
PERMIT CONTRACTOR:
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
DESCRIPTION OF WORK Verizon Wireless,Remove and replace existing telecom antennas,replace existing radios in exterior cabinets, PLUMBING,MECHANICAL,OR
replace backup batteries. FIRE SPRINKLER WORK
SMOKE ALARMS AND
CARBON MONOXIDE
I DETECTORS REQUIRED
THROUGHOUT DWELLING
USE OF BUILDING Commercial FIRE SPRINKLER REQUIRED? Yes UNIT PER CITY OF ASPEN
2021 I MC MUNICIPAL CODE 8.15
CLASS OF WORK Commercial FIRE SPRINKLER TYPE
311(1,5 Equipment and appliances on roofs or elevated point of ladder access to the bottom of the roof hatch.
REQUIRED SPECIAL structures.Where equipment rc&uinng access or appliances A minimum clear width of 15 inches (381 mm) shall 1 It should be known that this review shall
BUILDING TYPE(IRE) INSPECTIONS beprovided on both sides of the ladder measured not relieve the applicant of their
are located on an elevated structure or the roof of a building responsibility to comply with the
from the midpoint of andparallel with the rungs requirements of the City of Aspen
such that personnel will have to climb higher than 16 feet p g Municipal Code.Pursuant to
CONSTRUCTION TYPE IA ENERGY CODE COMPLIANCE except where cages or wells are installed. Sec.26.104.050,any permit or approval
(4877 min) above grade to access such eyutpnrent or apple- issued in error or otherwise not in
Wren an interior or exterior means of access shall be 8. Landing required. The ladder shall be provided with conformity with the requirements of this
WORRCHANGESBUILDING r Title,shall be void.Similarly,any permit
OCCUPANCY GROUP(IBC) R-1 NO
FOOTPRINT? provided, Such access shall not require climbing over a clear andunobstructed bottom landing area having or approval issued in reliance upon or
a minimum dimension of 30 inches (762 mm)by30 as a result of,a materially false
obstructions greater than 30 inches (762 mm) in height or statement or representation made in
CODE EDMONS 2021 IBC TOTAL SPASQ.FT. inches(762 mm)centered in front of the ladder. the process of obtaining the permit or
walking on roofs having a slope greater than 4 units vertical development approval shall,likewise,
i9. Ladders shall be protected against corrosion by be void.Any person having received a
In l units horlZoantal (3 3-pel'L eltt slope). Such aCceXS shall void or voidable permit or approval
OTHER CODE EDITIONS 2021 IEBC TOTALSNOWMELTSQ.FT. approved means. shall not be relieved from having to
not require the use of portable ladders. where' access comply with all applicable terms and
involves climbing over parapet walls, the height shall be 10. Access to ladders shall be provided at all times. conditions of this Title and the City shll
HISTORIC PROPERTY? I No TOTAL POOL SQ.FT. not be estopped from fully enforcing
measured to the top of the parapet wall. Catwalks installed to provide the required access shall be same.
Permanent ladders installed to provide the required acmes not less than 24 inches (610 mm) wide and shall have rail
FIRE SPRINKLER EXISTING? Yes ings as required for service platforms.
shall comply with the following minimum design criteria:
I. The side railing shall extend above the parapet orException: This section shall not apply to Group R 3 r �Yoccupancies. 5/2024
2021 IBC roof edge not less than 30 inches(762 mm). ,p
2. Ladders shall have rung spacing not to exceed 14 ' CUIMPLIANCE
linzhid
1015.6 Mechanical equipment, systems and devices. inches(356 nun)on center. The uppermost rung shall
Guards shall be provided where various components that be not greater than 24 inches (610 mm) below the
require service are located within 10 feet (3048 mm) of a upper edge of the roof hatch, roof or parapet, as
roof edge or open side of a walking surface and such edge or applicable.
open side is located more than 30 inches(762 mm)above the 3. Ladders shall have a toe spacing not less than 6
floor, roof or grade below. The guard shall extend not less
than 30 inches (762 mm) beyond each end of such compo- inches (152 mm)deep.
nents. The guard shall be constructed so as to prevent the 4. There shall be not less than 18 inches (457 mm i
passage of a sphere 21 inches(533 mm)in diameter. between rails_
Exception: Guards are not required where personal fall 5. Rungs shall have a diameter not less than 0.75-inch
arrest anchorage connector devices that comply with (19.1 nun) and be capable of withstanding a 300-
ANSI/ASSE Z 359.1 are installed. pound(136 kg)load.
6. [.adders over 30 feet 1.9144 mm) in height shall he
1015.7 Roof access. Guards shall be provided where the provided with onset sections and landings capable of
roof hatch opening is located within 10 feet(3048 mm)of a withstanding I[K) pounds per square foot (48lt
roof edge or open side of a walking surface and such edge or kin-). I.anding dimensions shall he not less than 18
open side is located more than 30 inches(762 mm)above the
floor, roof or grade below. The guard shall extend not less inches (457 mnt) and not lea than the width of the
than 30 inches(762 mm)beyond each end of the hatch paral- ladder served. A guard rail shall be provided on all
lel to the roof edge. The guard shall be constructed so as to open sides of the landing_
prevent the passage of a sphere 21 inches (533 mm) in 7. Climbing clearance. The distance from the centerline — o 0 0 -
diameter. of the rungs to the nearest permanent object on the D
Exception: Guards are not required where personal fall climbing side of the ladder shall he not less than 30 _IL 0 1pin74
arrest anchorage connector devices that comply withjeffreyb
g p y inches (762 mm) measured perpendicular to the ZONING
ANSUASSE Z 359.1 are installed. rungs. This distance shall be maintained from the