HomeMy WebLinkAboutFile Documents.301 E Hyman Ave.0027-2024-BCOM (6) Field Plan Set Must Be Printed In Color 1►�►1
APPLICATION ACCEPTED DATE: 2024-06-04 PERMIT NUMBER: 0027-2024-BCOM ;;';;0
COMMUNITY DEVELOPMENT DEPARTMENT �.y�r4 I
BUILDING PERMIT COVERSHEET
Si�::e CITY OF
CITY OFASPEN ASPEN
PROPERTY INFORMATION
ADDRESS: 301 E HYMAN AVE 301 UNIT: These plans muus eKeeptatthe
PARCEL ID: 273718209018 LEGAL DESCRIPTION: PROSPECTOR building site or inspection
OWNER: PROSPECTOR FRACTIONAL OWNERS ASSOC
delays may occur.Construction
PERMIT CONTRACTOR:
shall conform to these plans.All
changes shall be approved by
DESCRIPTION OF WORK -Demo existing stairs Ifilig
ing official.
-Reconnect existing snowmelt
-Rebuild stairs to code SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING,MECHANICAL,OR
FIRE SPRINKLER WORK
USE OF BUILDING Mixed-Use FIRE SPRINKLER REQUIRED? Yes
SMOKE ALARMS AND
CARBON MONOXIDE
CLASS OF WORK Commercial FIRE SPRINKLER TYPE NFPA 13R DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT
ASPEN
BUILDING TYPE(IRC( REQUIRED SPECIAL MUNICIPAL CODE 8.15
INSPECTIONS
CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE
WORK CHANGES BUILDING It should be known that this review shall
OCCUPANCY GROUP(IBC) R-2 FOOTPRINT? No not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
CODE EDITIONS 2021 IEBC TOTAL SPA SQ.FT.
Municipal Code.Pursuant to
Sec.26.104.050,any permit or approval
issued in error or otherwise not in
OTHER CODE EDITIONS TOTAL SNOWMELT SQ.FT.
conformity with the requirements of this
Title,shall be void.Similarly,any permit
HISTORIC PROPERTY? No TOTAL POOL SOFT. or approval issued in reliance upon or
as a result of,a materially false
statement or representation made in
FIRE SPRINKLER EXISTING? vas the process of obtaining the permit or
development approval shall,likewise,
be void.Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
External Energy Use Approved not be estopped from fully enforcing
same.
❑ RREMP ❑X CREMP
PERMIT#:0027-2024-BREP DATE: 10/21/24
SNOWMELT: 56
POOL:
SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ'S
All anowmelt systems shall meal me following: SPA:
-Any portions In the Right of Way must be on a separate zone.A ROW permit
NOTES: and Permanent Encroachment License are required. REMP SHEET:
-1110 insulation shall be installed under the area to be snowmeued or R5 insulation MINIMUM BOILER AFUE:
shall be installed under the slab edges.(ordinance 11 Series 2011)
1. EXISTING SIDEWALK TO REMAIN, -Automatic controls metalled for system shut off when pavement temperature is above OFFSET: PAVEaPLIT r1PrinM
FIELD VERIFY AND COORD STAIR& 50°F and no precipitation is facing.(20151ECC R403.9 and C403.2.4.5)
SIDEWALK INTERFACE TO MINIMIZE -Automatic or manual controls installed for system shut on when outdoor temperature
DIFFERENTIAL SETTLEMENT is abave40°F.(20151EC014403gan0 C403.2.3.5) REVIEWED BY: n
POTENTIAL. - by testing hydrostatically at is DO times max system design pressure.but not
2.CONCRETE STAIRS ON GRADE,RISE& i,for 15 minutes.12015 IMC 1208.1 I SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REDS.
RUN PER ARCH. All snowmelt systems shall meet the following:
3.#4 NOSING BARS. -Any portions In the Right of Way must be on a separate zone.A ROW
permit and Permanent Encroachment License are required.
4.64 @ 12"0.c.EACH WAY. -R10 insulation shall be Installed under the area to be snow melted or R5
5.1/2"EXPANSION MATERIAL. insulation shall be installed under and at the slab edges.(Ordinance 11
6.EXISTING SIDEWALK TO REMAIN. Series 2011)
7.SUITABLE COMPACTED SUB-GRADE. (1) -Automatic controls installed for system shut off when pavement
temperature is above 50°F and no precipitation is falling.(20091 ECG
Sec.403.8&503.2.4.5)
(2) -Automatic or manual controls installed for system shut off when outdoor
(3) temperature is above 40°F.(20091ECC Sea 403.8&503.2.4.5)
-Inspection by testing hydrostatically at 1%gmes max system design
pressure, not less than 100psi.for 15minutes.(20091MC Sec.
1208.1)
7 •ILA
(4)
��`P� -' —III=1
(5) ' II'
(6)
11-1 '
o•c aNDO LICFtiS
II
fps".".eo IIr
1 0" 16VQC/l'ItS� .W� �" Ti
� r1a35 �
10/21/2029.0
POPCOUEO(BWUANOE /rII p,� ^ ��
aenism
05/2112024
SSK O1 CONCRETE STAIRS ON GRADE
0006000
Project 24.037
M G Prospector Condos Entry Stair Date 5.21.2024
STRUCTURAL 301 E Hyman Avenue Drawn s
Aspen,Colorado 81611 Sheet r ���
ASPEN
BUILDING DEPARTMENT