Loading...
HomeMy WebLinkAboutFile Documents.1010 E Hyman Ave.0056-2020-BRES (19) 4k =Ur Ali THE CITY OF ASPEN - City of Aspen and Pitkin County di '- 4.... FIREPLACE & WOODSTOVE REGISTRATION *Parcel Id number: 273718147002 -- -- -- Street Address: 1010 East Hyman,Aspen CO 81611 Owners Name: MARILEE SUSI *RequiredContact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note:If the number, type and location on this registration form do not match what is show on your plans or what is actually installed,your permit or Certificate of Occupancy will be denied. Type of Building (circle one): Reside ntial Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert: model number: Gas log fireplace (select one) ?Site-built masonry LIVING ROOM 1 1 ?Factory built insert: model number: SEE ATTACHED Certified woodstove Gas fireplace appliance FAMILY ROOM 3 2 SEE ATTACHED (attach spec sheet) MASTER BEDROOM BEDROOM TWO (EXISTING&WILL REMAIN) If any devices are being removed, please describe here, i.e. "old woodstove removed from living room" • THERE ARE 3 EXISTING DEVICES. (1)LIVING ROOM GAS LOG SET • THAT WILL BE REMOVED AND (2)APPLIANCES AT THE MASTER BEDROOM,FAMILY ROOM • REPLACED WITH SAME. 4-14/ ENE 8,2020 RECEIVED Signature of applicant 'MrDate 0 7/2 0/2 0 2 0 G:\city\buildmg_dept\Aspen 2004 Checklsts\fireplace registration .doc ASPEN over BUILDING DEPARTMENT MONTIGO -------------- - - - - LIVING ROOM 13.17.20 I PAGE 1 OF 2 H SERIES HW38DF .,a► W/ TRADITIONAL LOGSET / gi. I a I I I . A i , , r ' d • a ♦ q • . 4 // --'' '.‘, .. . . fp . -AI In •• r� • :4 +i: gyp.. �" { s I rO Ci oC . MEDIA: PLATINUM FIREGLASS `L GLACILR f. . At . . . , . . . .• • •. . • _ 4 i H W 1219 B — -- m s , '\ HW1157 1,1v1H-e - -oot\el- 14 - F_IA6-', .!x-pk. )/ 1 . . .' • � ' FIREBOX INTERIOR: BLACK PORCELAIN i d0 , 4. COPPER �� HW1143 .1 1 U) '�� V PLATINUM HW1144 ~ " ' •+1IVS It* RECEIVED 07/20/2020 ASPEN BUILDING DEPARTMENT MONTIGO LIVING ROOM 13.17.20 I PAGE 2 OF 2 H SERIES HW38DF https://www.montigo.com/product/hw38df/ https://www.montigo.com/drive/uploads/2019/05/XB2212-Montigo-Fireplaces- H-Series-SingleSided-Brochure.pdf https://www.montigo.com/drive/uploads/2018/06/montigo-traditional-si ngle- sided-residential-fireplace-H38-spec-sheet.pdf - i 1 1 1 . 170, /, , LIA 1 L 1 K P Q o Q r Q 4. a A . _ __ C [ { 1 : I { -1' "...'. 1.... c, M E F R I- N -; B - --t s H I---"-- .--...„ T A © i_, D E F G H I J is, _ M N 0 1.0 f a T H34 313 33% 51 5% 331 31%• 17'. 11'4h. 25'S%• 33 35% 7%i 35% 11'%• 40 33% 56'/. 39 20 33'h RECEIVED H38 35%• 373< 4 %. 5/ 371S. 37'/i 18% 10% 281 35'h 394i• 6%• 38' . 114'i. 43% 37% 62 42 21% 37% 07/20/2020 H42 39%6 42 4KM. 5% 41%. 40'/: 19t3►i• 12'i. 33% 40'h 43% 7% 42'/a 11% 48Vs 42 68 46' 2 21% 42 ASPEN BUILDING DEPARTMENT LUXURIATM 50 DIRECT VENT LINEAR GAS APPLIANCE NAPOLEON Specifications Model BTU Width Height Depth Viewing Area Actual Framing Actual Framing Actual Framing LVX5ON 38,000 65 5/16 65 13/16 41 3/16 73 17 11/16 18 54 1/8 X 18 5/8 LVX5ON2 38,000 65 5/16 65 13/16 41 3/16 73 16 3/16 16 3/16 54 1/8 X 18 5/8 Glass Guard Assembly ± 0.047 0 t 51.594 Is 0 e,11 If 1 r 0.047 i 0.750 Framing Dimensions single-sided see-thru note: -� Before framing the appliance,ensure to install the .,\ firestop first. Before framing the appliance,ensure to install the firestop first as it will not note: fit between the studs if installed after \, The LVX series requires a minimum framing. I�"` enclosure height of 73"measured from the bottom of the appliance.For note: temperature requirements,this area The LVX series requires a minimum must be left unobstructed.Some enclosure height of 73"measured venting configurations that require from the bottom of the appliance.For more vertical rise will require a larger temperature requirements,this area enclosure to provide minimum vertical must be left unobstructed.Some clearance between vent pipes and venting configurations that require combustibles. more vertical rise will require a larger 1111* Illiciolo. enclosure to provide minimum vertical J combustibles.tween vent pipes and `I!I,I ► J minimum framing minimum framing IRef I LVX50 Ref _ LVX50 E I 18"(45.7cm) E 16 3/16"(41.1cm) F I 65 13/16"(167.2cm) F 65 13/16"(167.27cm) I J I Optional-Appliance does not need to be elevated above floor J Optional-Appliance does not need to be elevated above floor I *L 73"(185.4cm) *L 73"(185.4cm) *Minimum enclosure height maybe higher depending on venting configuration(see minimum distance to combustibles). r� ff Product information provided is not complete and is subject to change without notice. Please consult the instaIIRFnC Lfb fl the most up to date installation information. ((�� �?((T1�� � wd157187 .10.3 0 2 0 24 Napoleon Road,Barrie,Ontario,Canada L4M 0G8•214 Bayview Drive,Barrie,Ontario,Canada L4N 4Y8 Fireplaces,Heating and Cooling:705-721-1212•Grills:705 726-4278•napoleonproducts.com ASPEN BUILDING DEPARTMENT LUXURIATM 50 DIRECT VENT LINEAR GAS APPLIANCE NAPOLEON Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information. Dimensions single—sided see—thru Base of sir collar ' — . Base of air collar [,..mini AiiL 6 ® I . • [1samm] 0 0 911/16. [a3 mini[aoammfi [teeamm] [ream.] I GLASS GUARD I 32 3/re • U. [...`i GLASS GUARD [e32mm7 B>'smm] - -® - ®- ®- - - [zo:mini ees o.I t I' -• e,nc. 1 - vtc d,ns" [zesmm] es, A Demm] l[nsmm] - 'Iwo oao' nz7mml — W4amm1 1 _ A 31re" [411m16""] [eomm] [2oa III,. r* 2". dnimi Idosmm] ins [,”mini [103m] LVX50 m m C m m - LVX50 A 54 1/8" i— AI% A 5A 54 1/8" J: �,�.� (Finishing Flange) (1375mm) e,ne' I— `7f (Finishing Flange) (1375mm) a,h4• • B 65 5/16" [2eamm] i m -m m i i' m i B 65 5/16" [2Pamm, I� � r i m •im m m-- m i (1659mm) f B (1659mm) i B C 69 5/16" C 69 5/16" (1761 mm) C (1761 min) — C *Finishing flange depth.(The finishing flange defines the perimeter of the fireplace opening.Framing or finishing materials *Finishing flange depth.(The finishing flange defines the perimeter of the fireplace opening.Framing or finishing materials must NEVER encroach inside the finishing flange.) must NEVER encroach inside the finishing flange.) Wall Penetration 1°125mm]minimum all sides for See-thrG 3•[76mm1(minimum all sires for sections of sections of vertical renting. 6"152mm minimum 1'125mm] horizontal renting) tote. 9 [ I minimum all outside M enclosure. (Inside enclosure) 6'[152mm1 Shaded c0mporems(finisM1 hemirg)mus[be When passing through a calling, sides for _ se&estop spacer W500-00213 , redone of minimum non combustible materiels. trio supplied) Weida of op vertical ' (inside endgsgre) j �� loumde of enclosure) n., 3°76mml to top . (outside of endow.) 11�=1 2..[stmmlm sides/ When passing through \ �- ■��-III bottom wiling.use leestoo spacer . 1,(36.0,19 2"[51mm1 to sides/ ot )INII • finish- ml umII1! m1ufi pas b(W010L17e)plm giro ® 0"to backstandotts M.11 III standoffs The LVX series requires a minimum enclosure height of 73"(165.4cm)maa- .,to side standoffs12"finishing flange sued from the bottom of the appliance. (4 sides) For temperature requirements,this area must be left unobstructed.some venting The MI series requires a minimum enclosure height 73' a54crm !hIiUFuui ge ® g (1 )measuredor temperature requirements,this area most be I� appliance rise minimum vertical clearance between ten unonstmdetl.some veining wnfiguratlons mat require more vedlcel rise will I vent pipes and combustibles. e e •.I require a larger enclosure to provide minimum vertical clearance between vent pipes ��II Iry two•m anti combustibles. 0"to bottom of the .'-. „—Wi• ppliance Horizontalventsections:A minimum clearance of 3"(76mm)on the top outside of the enclosure and 2"(51mm)wine sides and bottom outside of the enclosure Horizontal vent sections:A minimum clearance of 3°(76mm)on the top outside of the enclosure and 2°(51mm)on the sides and bottom outside of the all around the vent pipe on all horizontal runs to combustibles is required.Horizontal vent sections within enclosures require a minimum clearance of 6"(152mm)at the enclosure all around the vent pipe on all horizontal runs to combustibles Is required.Horizontal vent sections within enclosures require a minimum clearance of top of the vent pipe. 6"(152mm)at the top of the vent pipe. Vertical vent sections:A minimum of1"(25mm)an around the vent pipe on sll vertical tons to combustibles is required except for clearances in appliances enclo- Vertical vent sections:Aminimum of 1"(25mm)all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliances sures.Vertical vent sections within enclosures require a minimum clearance of 1'(25mm)around the vent pipe. enclosures.Vertical vent sections within enclosures require a minimum clearance of re(25mm)around the vent pipe. Combustible Mantel Clearances Appliance Location G MANTEL DEpTF1 +1'(2.54cm)min. la - !6"(16.2cm)min. `r X 22Nommosnoso 1_ F F LVX50 minimum framing 2DMMPMiEMMEN. — �0 ........... MH 16••••••••.•• MANTEL HEIGHT Y T G 18........... v 1 1 1 F 65 13/16"(167.2cm) L 7 6••••••••••• n or \\\\�, / G 72 1/4"(183.5cm) . 4........... finishing _E_ H 18 3/16"(46.2cm) 2..........■ flange ........... I 102 3/16"(259.5cm) 0 1 2 3 4 5 6 7 8 9 1011 2511/16"(65.2cm) Bottom of Do not put objects In front finishing of the appliance(minimum MANTEL DEPTH mange distance of 4 feet) depth restriction) RECEIVED extension(no " I depth restrkiion) tlan of the �• • r .pq.noe I IP®., *Single-sided model illustrated. W41'5-1801919.3020 24 Napoleon Road,Barrie,Ontario,Canada L4M 0G8•214 Bayview Drive,Barrie,Ontario,Canada L4N 4Y8 Fireplaces,Heating and Cooling:705-721-1212•Grills:705 726-4278•napoleonproducts.com ASPEN BUILDING DEPARTMENT SPEC SHEET monTioo® H Series HL42 LINEAR GAS FIREPLACE DIMENSIONS [203] [126] PART ACTUAL FRAMING 08" 04 16" [187] 78 FRONT WIDTH 439n6" 42" BACK WIDTH 281/2"1111 42" [577] 224" HEIGHT 414n6" 461/2" DEPTH 20W' 21%" VIEWING AREA 39h"X28'/4" N/A ~2333] [1067] 1284], 8 92, Oir i " _ 1002 —.—_ _- `.- "I"- 3916] _ [123] 19516]. 1' [1059] [773] It8140 [ ] 3011089 1 — � ��� �_ [288] [91] —51 [310] 11 8" 2" [1106] 4 12 6' 4316" FEATURES 0"clearance to corners only •Snap-lock door for access I „or to firebox I �° 2‘ 46'h" 48'/a" •Clean face design _.� 42" Y •Snap-lock door for access A I A, to the firebox / 68" 42" •Hi/lo control to adjust \' / 21%">' flame level •Convertible to top or rear TECHNICAL SPECIFICATIONS flue vent HL42 standard with: HL42 options: •Linear contemporary burner + white/opal/ •Tempered glass •Remote control opaque firestones •Door screen •Fireplace surround in satin •Hi/lo control to adjust flame black or stainless steel level •Fan kit • •34,000 BTU Linear burner with firestones z 4 • 4 • _ . RECEIVED ..... .... .g." • iiJ.J ` •.. . 07/20/2020 t . r - •S • I• 4 ASPEN ilsop , • 4. BUILDING DEPARTMENT