Loading...
HomeMy WebLinkAboutFile Documents.1010 E Hyman Ave.0025-2022-BCHO (31) ESICC EVALUATION SERVICE' ICC-ES Evaluation Report EG. ESR-2836 r Reissued August 2021 tr; Revised January 2022= � r = This report is subject to renewal August 2022. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council'' DIVISION: 04 00 00—MASONRY weight of the installed veneer units is less than 15 pounds Section: 04 73 00—Manufactured Stone Masonry per square foot (73.2 kg/m ). REPORT HOLDER: Evaluated veneer styles are as follows: • Cobble Stone SUNSET STONE. INC. • Field Stone EVALUATION SUBJECT: • Limestone • Castle Stone SUNSET MANUFACTURED PRECAST STONE VENEER • Moss Rock 1.0 EVALUATION SCOPE • River Rock 1.1 Compliance with the following codes: • Ledge Stone • 2021. 2018. 2015. 2012 and 2009 International Building • Stacked Stone Code' (IBC) • Regal Stone • 2021. 2018. 2015. 2012 and 2009 International • Western Ledge Residential Code'' (IRC) Properties evaluated: • Dry Stack Ledge Properties addressed in ASTM C1670 The attributes of the stone veneer have been verified as conforming to the provisions of (i) CALGreen Section 1.2 Evaluation to the following green code(s) and/or A4.405.1.3 for prefinished building materials and Section standards: A5.406.1.2 for reduced maintenance: (ii) ICC 700-2020. • 2019 California Green Building Standards Code ICC 700-2015 and ICC 700-2012 Sections 602.1.6 and (CALGreen). Title 24. Part 11 11.602.1.6 for termite-resistant materials: (iii) ICC 700- • 2020. 2015. 2012 and 2008 ICC 700 National Green 2020 Sections 601.7 and 11.601.7 and ICC 700 2015 and Building Standard-P.' (ICC 700-2020. ICC 700-2015. ICC ICC 700-2012 Sections 601.7. 11.601.7, and 12.1(A).601.7 700-2012 and ICC 700 2008) for site-applied finishing materials: and (iv) ICC 700-2008 Section 602.8 for termite-resistant materials and Section Attributes verified: 601.7 for site-applied finishing materials. Note that See Section 3.0 decisions on compliance for those areas rest with the user 2.0 USES of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific Sunset Manufactured Precast Stone Veneer is used as an conditions. and the verification of those conditions is adhered. nonload-bearing exterior veneer on exterior walls outside the scope of this report. These codes or standards of wood stud or light-gage steel stud construction. concrete often provide supplemental information as guidance. or masonry walls. 4.0 DESIGN AND INSTALLATION 3.0 DESCRIPTION 4.1 General: The veneer is an adhered manufactured stone masonry Installation of the veneer units must comply with this veneer(AMSMV) complying with ASTM C1670. referenced report. the manufacturer's published installation in 2021 and 2018 IBC Section 2103.1 and 2021 and 2018 IRC Section R606.2.6. The AMSMV is made to resemble instructions. and the applicable code. The manufacturer's natural stone in color and texture. The veneer is composed published installation instructions must be available at the of portland cement. aggregates. coloring pigments. jobsite at all times during installation. In accordance with admixtures. and water. The veneer units are molded and the code. the veneer can be applied over a lath and mortar cured at the manufacturing facility. scratch coat or applied directly to concrete or masonry. Under the 2012 and 2009 IBC and IRC. which do not The veneer units are of various thicknesses from 1 inch address installation requirements. the provisions of the to 2 inches (25.4 to 50.8 mm). The maximum saturated 2015 or later IBC and IRC should be followed. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or am other attributes not specificaiir addressed,nor are tier to be construed as an endorsement of the subject of the report or a recommendation for its use There is no»tin anti In ICC Evaluation Service,LLC,e.,pness or implied,as lq _Mi116 to ant_finding or other matter in this report,or as to ant product covered by the report !�! _ Copyright©2022 ICC Evaluation Service,LLC All rights reserved Page 1 of 2 ESR-2836 Most Widely Accepted and Trusted Page 2 of 2 4.2 Installation Over a Lath and Mortar Scratch Coat 5.2 Expansion or control joints. used to limit the effect of Over Framed Walls: differential movement of AMSMV supports on the The scratch coat must be installed over a water-resistive veneer system. are to be specified by the architect. barrier complying with IBC Section 1404.10.1.1 (2015 IBC designer or veneer manufacturer. in that order. Section 1405.10.1.1) or IRC Section R703.12.3. as Consideration must also be given to movement applicable. Also. flashing must be installed as required by caused by temperature change. shrinkage. creep and IBC Section 1404.10.1.2 (2015 IBC Section 1405.10.1.2) deflection. or IRC Sections R703.4 and R703.12.2. as applicable. 5.3 In jurisdictions adopting the IBC. the supporting wall including a foundation weep screed installed at the bottom must be designed to support the installed weight of of the stone veneer. The foundation weep screed must the veneer system. including veneer. setting bed and comply with. and be installed in accordance with. the scratch coat. as applicable. Horizontal framing requirements for flashing at foundation shown in IBC members. such as lintels and headers. which support Section 1404.10.1.2.1 (2015 IBC 1405.10.1.2.1) or IRC AMSMV must be designed to limit deflection to liecc of Section R703.12.2. as applicable. The veneer must be the span. installed with the clearances required by IBC Section 1404.10.1.3 (2015 IBC Section 1405.10.1.3) or IRC 5.4 In jurisdictions adopting the IRC. where the seismic Section R703.12.1. as applicable. provisions of IRC Section R301.2.2 apply. the Lathing must comply with IBC Section 2510 [referenced average weight of the wall supporting the AMSMV, from IBC Section 1404.10.1.4.1 (2015 IBC 1405.10.1.4.1)] including the weight of the veneer system. must be or IRC Section R703.7.1 (referenced from IRC Section determined. When this weight exceeds the applicable R703.12). The scratch coat must be applied in accordance limits of IRC Section R301.2.2.2.1 ust an engineered with IBC Section 1404.10.1.4.2 (2015 IBC Section design of the wall construction must be performed in 1405.10.1.4.2) and the veneer units must be adhered to accordance with IRC Section R301.1.3. the scratch coat in accordance with IBC Section 5.5 The AMSMV units are manufactured under a quality 1404.10.1.4.3 (2015 IBC Section 1405.10.1.4.3). The control system with inspection by ICC-ES. mortar used to adhere the veneer units to the scratch coat must comply with IBC Section 2103.2.4 or IRC Section 6.0 EVIDENCE SUBMITTED R606.2.11 (2015 IRC Section R606.2.10). Data in accordance with the ICC-ES Acceptance Criteria 4.3 Installation over Concrete and Masonry: for Adhered Manufactured Stone Masonry Veneer(AC51). Installation over concrete and masonry must comply with dated June 2018 (editorially revised January 2021). IBC Section 1404.10.1.5 (2015 IBC Section 1405.10.1.5). 7.0 IDENTIFICATION When adhering the veneer units directly to the concrete or masonry. the supporting surfaces must be prepared in 7.1 Boxes of the precast stone veneer units are accordance with IBC Section 2510.7: and the veneer units identified with the manufacturer's name (Sunset must be adhered to the supporting surface as described in Stone. Inc.). product name. style name. and the Section 4.2. When adhering the veneer units to a lath and evaluation report number(ESR-2836). mortar scratch coat. the lathing and scratch coat 7.2 The report holder's contact information is the preparation must comply with Section 4.2 of this report. following: 5.0 CONDITIONS OF USE SUNSET STONE, INC. The Sunset Manufactured Precast Stone Veneer described 702 PRAIRIE HAWK DRIVE in this report complies with. or is a suitable alternative to CASTLE ROCK, COLORADO 80109 what is specified in. those codes listed in Section 1.0 of (303) 791-1233 this report. subject to the following conditions: www.sunsetstone.net 5.1 Installation must comply with this report. the manufacturer's published installation instructions and the applicable code. In the event of a conflict between the manufacturer's published installation instructions and this report. this report governs.