Loading...
HomeMy WebLinkAboutFile Documents.901 E Hyman Ave.0011-2023-BROF (5) ICC ESEVALUATION SERVICE ICC-ES Evaluation Report ESR-2053 Reissued July 2020 This report is subject to renewal July 2022. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE both sides with a mineral-filled aqueous coating. The PROTECTION underlayment has a weight of 15 pounds per 100 square Section: 07 30 05—Roofing Felt and Underlayment feet(0.73 kg/m2), and is supplied in rolls. REPORT HOLDER: 4.0 INSTALLATION 4.1 General: GAF VersaShield° Fire-Resistant Roof Deck Protection is installed in accordance with the requirements of the EVALUATION SUBJECT: applicable code, the manufacturer's published installation instructions and this report. The manufacturer's published VERSASHIELD® FIRE-RESISTANT ROOF DECK installation instructions are to be available at the jobsite PROTECTION during the installation. 1.0 EVALUATION SCOPE VersaShield° Fire-Resistant Roof Deck Protection is limited to use over spaced or solid sheathing, or over Compliance with the following codes: existing asphalt shingles, wood shakes or wood shingles • 2021*, 2018, 2015, 2012, 2009 and 2006 International installed on spaced or solid sheathing. Prior to application Building Code°(IBC) of the underlayment, the deck surface is to be free of dust • 2021*, 2018, 2015, 2012, 2009 and 2006 International and dirt, loose nails and other protrusions. Damaged Residential Code°(IRC) sheathing is to be replaced.The underlayment is applied at right angles to the slope of the roof, beginning at the low • 2013 Abu Dhabi International Building Code(ADIBC)t point of the roof, and is laid with minimum 2-inch (51 mm) tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced horizontal and 6-inch (152 mm) vertical lapped joints. It is in this report are the same sections in the ADIBC. attached with a sufficient number of nails, having tin caps or 'For evaluation for compliance with the anticipated requirements of the 2021 1-inch-diameter (25.4 mm) plastic caps, to hold the IBC and IRC. underlayment in place until the roof covering is applied, Properties evaluated: except in areas subject to high winds where the underlayment fastening must comply with the high wind • Physical properties attachment requirements specified in IBC Section 1507 or • Fire classification IRC Section R905. The underlayment may be bent to a minimum 1/2-inch(12.7 mm)radius, but is not to be creased. 2.0 USES At junctions between the roof deck and vertical surfaces,the VersaShield° Fire-Resistant Roof Deck Protection is used underlayment is installed a minimum of 3 inches(76 mm)up as an alternative to ASTM D226, Type I or Type II, roofing the vertical surface. underlayment specified in Chapter 15 of the IBC and In areas of the roof required to have an ice barrier under Chapter 9 of the IRC. Chapter 15 of the IBC or Chapter 9 of the IRC, a self- When installed in accordance with Section 4.2.1 of this adhesive polymer bitumen sheet, complying with ASTM report, VersaShield° Fire-Resistant Roof Deck Protection D1970 or the ICC-ES Acceptance Criteria for Self-adhered can also be used over existing wood shakes or shingles as Underlayments for Use as Ice Barriers (AC48), is to be an alternative to the covering materials specified in 2021, applied. The underlayment is to be applied over the solid 2018 or 2015 IBC Section 1511 (2012, 2009 or 2006 IBC substrate in sufficient courses so that the underlayment Section 1510.4) or 2021, 2018 and 2015 IRC Section extends up the roof a distance equal to the distance inside R908.4(2012, 2009 and 2006 IRC Section R907.4). the exterior wall line of the building that is specified by the VersaShield° Fire-Resistant Roof Deck Protection is also applicable code. The underlayment, applied in the field of used as a component of classified roofing assemblies as the roof, is to completely overlap the ice barrier (severe described in Section 4.3,when installed in accordance with climate underlayment) protection a minimum of 2 inches this report. (51 mm). 3.0 DESCRIPTION Installation of the roof covering can proceed immediately following the underlayment application.The underlayment is VersaShield° Fire-Resistant Roof Deck Protection is to be covered by a roof covering within the time set forth in a resin-bound chopped-glass-fiber substrate, coated on the manufacturer's published installation instructions. - r r' "(11 i \4t1 Li) ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed ice as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,asql to any finding or other matter in this report,or as to any product covered by the report rtt �ooicounni Copyright©2020 ICC Evaluation Service,LLC.All rights reserved. PaA',REN BUILDING DEPARTMENT ESR-2053 I Most Widely Accepted and Trusted Page 2 of 4 4.2 Reroofing: must be recognized in a current ICC-ES evaluation report The existing roof must be inspected in accordance with as shown in Table 2. 2021, 2018 or 2015 IBC Section 1511 (2012, 2009 or 2006 5.0 CONDITIONS OF USE IBC Section 1510) or 2021, 2018 and 2015 IRC Section The VersaShield® Fire-Resistant Roof Deck Protection R908.4(2012, 2009 and 2006 IRC Section R907).The new described in this report, complies with, or is a suitable roof covering is installed over the VersaShield® Fire alternative to what isspecified in, those codes listed in Resistant Roof Deck Protection in accordance with the roof Section 1.0 of this report,subject to the following conditions: covering manufacturer's published installation instructions. The new roof covering must be recognized in a current ICC- 5.1 Installation must comply with this report; the ES evaluation report, and, when applicable, the evaluation manufacturer's published installation instructions and report must address installation over wood shake, wood the applicable code. In the event of a conflict between shingle or asphalt shingle roofs. the manufacturer's published installation instructions 4.2.1 Existing Wood Shakes or Shingles: Where the and this report, this report governs. application of a new roof covering over wood shingle or 5.2 Installation is limited to roofs with a minimum slope of shake roofs creates a combustible concealed space, 2:12 (16.67 percent slope) or to the minimum slope VersaShield® Fire-Resistant Roof Deck Protection can be required for the roof covering in accordance with the used as an alternative to the covering materials specified in applicable code,whichever is greater. 2021,2018 or 2015 IBC Section 1511.4(2012,2009 or 2006 5.3 Installation is limited to use with roof coverings that do IBC Section 1510.4) or 2021, 2018 and 2015 IRC Section not involve hot asphalt or coal-tar pitch. R908.4 (2012, 2009 and 2006 IRC Section R907.4). The underlayment covers the entire existing wood roof. Battens 5.4 Installation is limited to use with approved roof used for the new roof covering system are installed over the coverings that are mechanically fastened through the underlayment. The underlayment may be placed under or underlayment to the sheathing or rafters. over counterbattens, spaced a maximum of 24 inches 5.5 Installation is limited to roofs with ventilated attic (610 mm) on center. The underlayment is fastened to the spaces in accordance with the requirements of the counterbattens with a sufficient number of nails, having tin applicable code. caps or 1-inch-diameter(25.4 mm) plastic caps,to hold the underlayment in place until the horizontal battens and roof 5.6 VersaShield® Fire-Resistant Roof Deck Protection is covering are applied. When counterbattens are installed produced in Conover, North Carolina, under a quality over the underlayment or when counterbattens are not control program with inspections by ICC-ES. used, the underlayment is fastened directly to the existing 6.0 EVIDENCE SUBMITTED roof covering in the same manner. Data in accordance with the ICC-ES Acceptance Criteria for 4.2.2 Existing Asphalt Shingles: When installed over Nonasphaltic Fiberglass-based Roof Underlayment existing asphalt shingles, the underlayment is applied over (AC160), dated January 2000 (editorially revised April the existing roof covering and fastened through the shingles 2020). to the sheathing with a sufficient number of nails, having tin caps or 1-inch-diameter(25.4 mm) plastic caps,to hold the 7.0 IDENTIFICATION underlayment in place until the roof covering is applied. 7.1 Each roll of underlayment bears a label indicating the 4.3 Roof Classification: GAF name and address, the plant identification, the product name, the roll number, and the evaluation When installed in accordance with this report,VersaShield® report number(ESR-2053). Fire-Resistant Roof Deck Protection can be used as an alternative to Exception 2 to IBC Section 1505.2 (Exception 7.2 The report holder's contact information is the following: to 2006 IBC Sections 1505.2 and 1505.3), and IRC Section GAF R902.1; or any roofing assembly having a Class A, B or C 1 CAMPUS DRIVE roof classification, without reducing the roof classification. PARSIPPANY, NEW JERSEY 07054 When installed in accordance with Section 4.1 and Table 1 (800)766-3411 of this report, roofing assemblies incorporating www.gaf.corn VersaShield®Fire-Resistant Roof Deck Protection have the roof classification specified in Table 1. The roof coverings RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESR-2053 I Most Widely Accepted and Trusted Page 3 of 4 TABLE 1—ROOF CLASSIFICATION OF ASSEMBLIES INCORPORATING VERSASHIELD°FIRE-RESISTANT ROOF DECK PROTECTION ROOF COVERING2 SUBSTRATE UNDERLAYMENT' ROOF MAXIMUM CLASSIFICATION SLOPE Class A asphalt glass fiber shingle 15/32-inch plywood One layer VersaShield® A Unlimited Stone coated,steel,direct to deck, 5/32_inch plywood or 0.013-inch thickness(0.330 mm), spaced sheathing One layer VersaShield® A Unlimited shingles or panels One layer VersaShield®, 15/32-inch plywood or and one layer Type 30 A Unlimited Steel direct to deck,0.013-inch spaced sheathing asphalt saturated organic thickness(0.330 mm),shingles or felt panels 15/32-inch plywood or One layer VersaShield® B Unlimited spaced sheathing 15/32-inch plywood or One layer VersaShield® A Unlimited spaced sheathing Steel over battens,0.013-inch Existing wood shakes or thickness(0.330 mm),shingles or shingles installed over Two layers VersaShield® A Unlimited panels spaced or solid sheathing Existing wood shakes or shingles installed over One layer VersaShield® B Unlimited spaced or solid sheathing Steel,0.016-inch thickness(0.406 15/32-inch plywood or mm),panels or standing seam spaced sheathing One layer VersaShield® A Unlimited system One layer VersaShield®, 15/32-inch plywood or and one layer Type 30 A Unlimited spaced sheathing asphalt saturated organic felt Existing wood shakes or shingles installed over Two layers of VersaShield® A Unlimited Copper,0.016-inch thickness(0.406 spaced or solid sheathing mm),shingles or panels 15/32 inch plywood or One layer VersaShield® B Unlimited spaced sheathing Existing wood shakes or shingles installed over One layer of VersaShield® B Unlimited spaced or solid sheathing 15/32-inch plywood or Two layers VersaShield® A Unlimited spaced sheathing Aluminum,0.018-inch(0.457 mm), 15/32-inch plywood or One layer VersaShield® B Unlimited shingles,panels,or standing seam spaced sheathing system Existing wood shakes or shingles installed over One layer VersaShield® B Unlimited spaced or solid sheathing 15/32-inch plywood Two layers VersaShield® A 11/2:12 TPO,CSM,CPA, EPDM,cap sheet, 15/32-inch plywood, or modified bitumen single-ply insulation Two layers VersaShield® A 11/2:12 membranes 15/32-inch plywood One layer VersaShield® B 11/2:12 15/32-inch plywood Two layers VersaShield® A 2:12 PVC single-ply membrane 15/32 inch plywood, Two layers VersaShield® A 11/2:12 insulation 15/32-inch plywood One layer VersaShield® B 11/2:12 For SI: 1 inch=25.4 mm. 1Underlayment must be installed in accordance with Section 4.0 of this report. 2Roof coverings must be recognized in a current ICC-ES evaluation report.The roof covering must comply with the Class A or B(lam,-§pr ad requirements of UL790(ASTM E108),as applicable to the systems defined in this table. RE IVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESR-2053 I Most Widely Accepted and Trusted Page 4 of 4 TABLE 2—EVALUATION REPORT CROSS-REFERENCE COMPANY ICC-ES EVALUATION RECOGNIZED PRODUCT REPORT NUMBER Carlisle Syntec ESR-1463 EPDM, PVC and TPO Single-Ply Membranes Delta Building Products, Ltd. ESR-1790 Delta Roof Panels:Shake,Tile and Hidden Fastener Tile; Delta Roof Shingles:Shingle,Slate and Diamond Steel Roofing Panels:Tile Profile:Decra Villa Tile;Shake Decra Roofing Systems, Inc. ESR-1754 Profile: Decra Shake XDTM;Shingle Profile: Decra Shingle XDTM; Panel Profile:Decra Shingle Plus TM Decra Roofing Systems, Inc. ESR-2901 Steel Roofing Panels:Tile Profile:DECRA Tile Shake Profile: DECRA Shake Shingle Profile: DECRA Shingle Plus Gerard Roofing Technologies ESR-1188 GRANITE-RIDGE SHINGLE STEEL ROOFING PANELS Ideal Roofing Company Ltd. ESR-3101 Wakefield Bridge(26 gage)Steel Panels and Wakefield Bridge(29 gage)Steel Panels Ideal Roofing Company Ltd. ESR-3100 HF-16 and HF-20.25 Roof Panels DaVinci Roofscapes,LLC ESR-2119 DaVinci Slate,DaVinci Shake,Bellaforte Shake and Bellaforte Slate Roof Shingles Feroof Co., Ltd. ESR-3331 Steel Roofing Panels:Veneto I, Veneto II, Rio,Rio EZ, Diva,Wood,Zissen and Slate Ensoltis Green Hybrid Roofing LLC ESR-2904 Ensoltis Savanna S Roof Tile Custom-Bilt Metals ESR-2048 Custom-Bilt Standing Seam Metal Roof:CB-150 and SL-1750 Roser Co.,Ltd ESR-1763 Roser Steel and Copper Roofing Panels Berridge Manufacturing Company ESR-3486 Berridge Cee-Lock and Zee-Lock Standing Seam Roof Panels 'The aluminum panels are limited to Class B roof covering assemblies. RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESICC EVALUATION � SERVICE' ES Compliance to International Codes E • Compliance to State/Regional Codes www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® ICC-ES Evaluation Report Reissued October 2021 ESR-1463 Revised March 2022 This report is subject to renewal October 2022. DIVISION: 07 00 00—THERMAL AND MOISTURE • Wind uplift resistance PROTECTION • Impact resistance Section: 07 53 23—Ethylene-Propylene-Diene-Monomer 2.0 USES Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Carlisle ethylene propylene diene monomer (EPDM), Section: 07 54 23—Thermoplastic-Polyolefin Roofing polyvinyl chloride(PVC)and thermoplastic polyolefin (TPO) single-ply roofing membranes are used as roof coverings in REPORT HOLDER: adhered and mechanically fastened membrane roofing systems. CARLISLE SYNTEC SYSTEMS, A DIVISION OF 3.0 DESCRIPTION CARLISLE CONSTRUCTION MATERIALS, LLC 3.1 General: EVALUATION SUBJECT: The EPDM, PVC and TPO Membrane Roofing Systems CARLISLE EPDM, PVC AND TPO SINGLE-PLY described in this report consist of single-ply roofing ROOFING MEMBRANES membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and ADDITIONAL LISTEES: adhesives that are installed on a combustible or noncombustible deck.See Table 1 for Carlisle product trade MULE-HIDE PRODUCTS COMPANY, INC. names and corresponding product names for Mule-Hide Products Company, Inc., WeatherBond, Versico, and VERSICO, A DIVISION OF CARLISLE CONSTRUCTION Roofing Products International, Inc.,the additional listees. MATERIALS, LLC 3.2 EPDM Membranes: WEATHERBOND, A DIVISION OF CARLISLE 3.2.1 Sure-Seal EPDM Membrane: Sure-Seal EPDM CONSTRUCTION MATERIALS, LLC Membrane is a black, nonreinforced EPDM membrane, 45 mils thick[0.045 inch (1.14 mm)]. ROOFING PRODUCTS INTERNATIONAL, INC. 3.2.2 Sure-Seal FR EPDM Membrane: Sure-Seal FR 1.0 EVALUATION SCOPE EPDM Membrane is a black, nonreinforced EPDM membrane with fire retardants.Available thicknesses range Compliance with the following codes: from 45 mils (0.045 inch [1.14 mm]) to 90 mils (0.090 inch • 2021, 2018, 2015, 2012 and 2009 International Building [2.29 mm]). Code°(IBC) 3.2.3 Sure-White EPDM Membrane: Sure-White EPDM • 2021, 2018, 2015, 2012 and 2009 International Membrane is a white, nonreinforced EPDM membrane. It is Residential Code°(IRC) available in thicknesses of 60 mils [0.060 inch (1.52 mm)] and 90 mils [0.090 inch (2.29 mm)]. • 2013 Abu Dhabi International Building Code(ADIBC)t tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced 3.2.4 Sure-Tough EPDM Membrane: Sure-Tough EPDM in this report are the same sections in the ADIBC. Membrane is a black, reinforced membrane consisting of a For evaluation for compliance with codes adopted by the polyester reinforcement encapsulated between two EPDM Los Angeles Department of Building and Safety (LADBS), membrane plies. It is available in thicknesses ranging from see ESR-1463 LABC and LARC Supplement. 45 mils [0.045 inch (1.14 mm)] to 75 mils [0.075 inch (1.90 mm)]. Properties evaluated: 3.2.5 Sure-Seal FleeceBACK EPDM Membrane: Sure- • Weather resistance Seal FleeceBACK EPDM Membrane is a 45-mil to 90-mil • Roof covering fire classification [0.045 inch to 0.090 inch (1.1 V .r D ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed ICC as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i to any finding or other matter in this report,or as to any product covered by the report. MCA Copyright©2022 ICC Evaluation Service,LLC. All rights reserved. PageAEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 2 of 14 2.29 mm)] non-reinforced EPDM bonded to a polyester Weld TPO Membrane specified in Section 3.4.1 for fleece. Available product thicknesses range from 100 mils increased strength and weatherability. The membrane is [0.100 inch (2.55 mm)]to 145 mils [0.145 inch (3.68 mm)]. available in white, gray, tan and custom colors.Available in 3.2.6 Sure-White FleeceBACK EPDM Membrane: Sure- a thickness of 80 mils(0.080 inch [2.03 mm]). White FleeceBACK EPDM Membrane is a 45-, 60-or 90-mil 3.4.3 Sure-Weld HS TPO Membrane:Sure-Weld HS TPO [0.045, 0.060 or 0.090 inch (1.14, 1.52 or 2.29 mm)] Membrane is the Sure-Weld membrane formulated with an nonreinforced white EPDM bonded to a polyester fleece. additional flame retardant for fire resistance at higher Available product thicknesses are 100, 115 and 145 mils slopes. The membrane is available in white, gray, tan and [0.100, 0.115 or 0.145 inch (2.54, 2.92 or 3.68 mm)]. custom colors.Available thicknesses are 45 mils(0.045 inch 3.2.7 Sure-Seal AFX EPDM Membrane: Sure-Seal AFX [1.14 mm])and 60 mils(0.060 inch [1.52 mm]). EPDM Membrane is a 45-mil [0.045 inch (1.14 mm) or 60- 3.4.4 Sure-Weld SAT-TPO Membrane: Sure-Weld SAT- mil [0.060 inch (1.52 mm)] non-reinforced EPDM bonded to TPO Membrane is a self-adhered version of the Sure-Weld a polyester fleece.Available thicknesses are 90 mils [0.090 HS membrane with adhesive. inch (2.29 mm)] and 105 mils [0.105 inch (2.67 mm)]. 3.4.5 Sure-Weld FleeceBACK TPO Membrane: Sure- 3.3 PVC Membranes: Weld FleeceBACK TPO Membrane is the Sure-Weld HS 3.3.1 Sure-Flex PVC Membrane: Sure Flex PVC TPO Membrane, 45 mils [0.045 inch Membrane is a heat-weldable PVC thermoplastic (1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils [0.60 inch (2.03 mm)] thick, with a laminated polyester membrane consisting of a weft-inserted polyester fabric that fleece backing. Available thicknesses are 100 mils is encapsulated by PVC based top and bottom plies. [0.100 inch(2.54 mm)], 115 mils[0.115 inch(2.92 mm)]and Available thicknesses range from 50 mils [0.050 inch (1.27 135 mils [0.135 inch (3.43 mm)]. mm)]to 80 mils [0.080 inch (203 mm)]. 3.4.6 Sure-Weld AFX TPO Membrane: Sure-Weld AFX 3.3.2 Sure-Flex KEE HP Membrane: Sure-Flex KEE HP TPO Memnbrane is the Sure-Weld HS TPO Membrane with Membrane is a heat-weldable theromoplastic membrane a laminated polyester fleece backing.Available thicknesses that consists of a polyester fabric that is encapsulated by range from 120 mils [0.120 inch (3.05 mm)] to 155 mils KEE HP based top and bottom plies. Available thicknesses [0.155 inch (3.94 mm)]. range from 50 mils [0.50 inch (1.27 mm)] to 80 mils [0.80 inch (2.03 mm)]. 3.4.7 Spectro-Weld TPO Membrane: Spectro-Weld TPO Membrane is the Sure-Weld membrane, described in 3.3.3 Sure-Flex PVC FRS Membrane: Sure-Flex PVC Section 3.4.1, formulated with a brighter white color. FRS Membrane is a heat-weldable thermoplastic Available thicknesses are 60 mils [0.060 inch (1.52 mm)] membrane that consists of a fiberglass reinforcement and 80 mils [0.080 inch (2.03 mm)]. encapsulated with PVC based top and bottom plies. Available thicknesses range from 60 mils [0.60 inch (1.52 3.4.8 Spectro-Weld FleeceBACK TPO Membrane: mm)]to 80 mils [0.80 inch (2.03 mm)]. Spectro-Weld FleeceBACK TPO Membrane is the Spectro- Weld membrane with a laminated 5.5-ounce-per-square- 3.3.4 Sure-Flex PVC FleeceBACK Membrane:Sure-Flex yard (0.18 kg/m2) polyester fleece backing. It is 115 mils PVC FleeceBACK Membrane consists of polyester [0.115 inch (2.92 mm)]thick. reinforcing scrim and polyester fleece backing. Available thicknesses range from 115 mils [0.115 inch (2.92 mm)] to 3.5 Insulation: 135 mils[0.135 inch (3.43 mm)]. See Tables 2 through 5 for insulations for use with specific 3.3.5 Sure-Flex KEE HP FleeceBACK Membrane: Sure- roofing systems. Foam plastic insulation,where used, must Flex KEE HP FleeceBACK Membrane consists of a have a flame-spread index of not more than 75 when tested polyester reinforcing scrim, polyester fleece backing, and at the maximum thickness intended for use in accordance DuPont° Elvaloy° KEE HP copolymer. Available with ASTM E84 or UL 723. thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 3.6 Barrier Board: 135 mils[0.135 inch (3.43 mm)]. Barrier board, where used, must be either minimum 3.3.6 Sure-Flex PVC FRS FleeceBACK Membrane: 1/4-inch-thick (6.4 mm) Georgia-Pacific Gypsum LLC Sure-Flex PVC FRS FleeceBACK Membrane consists of a "DensDeck°Roofboard" or"DensDeck Prime°Roofboard," high-strength fiberglass scrim and polyester fleece backing. minimum 1/4-inch-thick (6.4 mm) Owens Corning Available thicknesses range from 115 mils[0.115 inch (2.92 "StrataGuard," minimum 1/4-inch-thick (6.4 mm) USG mm)]to 135 mils [0.135 inch (3.43 mm)]. Corporation "SECUROCK° Gypsum-Fiber Roof Board" 3.3.7 Sure-Flex KEE HP FRS FleeceBACK Membrane: or "SECUROCK° Glass-Mat Roof Board," or minimum Sure-Flex KEE HP FRS FleeceBACK Membrane consists 1/2-inch-thick (12.7 mm) gypsum board. Barrier board must of a fiberglass reinforcing scrim, polyester fleece backing, be UL classified for roofing applications or UL classified and DuPont° Elvaloy° KEE HP copolymer. Available gypsum board. thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 3.7 Slip Sheet: 135 mils[0.135 inch (3.43 mm)]. The slip sheet,where used, must include Carlisle"FR Base 3.4 TPO Membranes: Sheet 1 S or 2S," GAF "VersaShield° Fire-Resistant Roof 3.4.1 Sure-Weld TPO Membrane: Sure-Weld TPO Deck Protection(ESR-2053)"or Atlas"FR 10 or FR 50."Slip Membrane consists of a polyester reinforcement sheets must be UL-classified for roofing applications. encapsulated between two plies of TPO. The membrane is 3.8 Flashing: I•"` available in white, gray, tan and custom colors. Available Flashing must be provided in accordance with IBC Section j - thicknesses range from 45 mils[0.045 inch(1.14 mm)]to 60 mils[0.060 inch (1.52 mm)]. 1503.2 or IRC Section R903.2, as applicaklhre. 2023 flashing is of metal, the metal must be corrosidil i 3.4.2 Sure-Weld EXTRA TPO Membrane: Sure-Weld minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized EXTRA TPO Membrane is a thicker version of the Sure- steel. ASPEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 3 of 14 3.9 Fasteners: penetrate through the steel deck a minimum of 3/4 inch Fasteners, used to mechanically attach insulation and (19.1 mm), and into the wood deck a minimum of 1 inch membranes to the roof deck, must be corrosion-resistant, (25.4 mm). and must be Carlisle fasteners, plates or fastening bars, 3.9.11 Piranha Fastening Plate: This is a 23/8-inch- unless otherwise noted in this report. Refer to Table 4 and diameter galvalume-coated steel plate designed to be used 5 for spacing of fasteners. with HP-X fasteners to mechanically attach PVC and TPO 3.9.1 HP Fastener: This is an epoxy-coated steel screw membranes to the roof deck. used in combination with Carlisle's fastening plates or bars 3.9.12 HP-XTRA Fastener:This is an epoxy-coated carbon to mechanically attach roofing insulation and membranes to steel screw used in combination with the Piranha XTRA steel or wood substrate. Fastener length must be selected Fastening Plate to mechanically attach PVC and TPO to penetrate through the steel deck a minimum of 3/4 inch membranes to steel or wood substrate. Fastener length (19.1 mm), and into the wood deck a minimum of must be selected to penetrate through the steel deck a 1 inch (25.4 mm). minimum of 3/4 inch (19.1 mm) and into the wood deck a 3.9.2 InsulFast Insulation Fastener: This is an epoxy- minimum of 1 inch (25.4 mm). coated steel screw used in combination with Carlisle's 3.9.13 Piranha XTRA Fastening Plate: This is a 23/s-inch- insulation plates to mechanically attach roofing insulation to diameter galvalume-coated steel plate designed to be used steel or wood substrates. Fastener length must be selected with HP-XTRA fasteners to mechanically attach PVC and to penetrate through the steel deck a minimum of 3/4 inch TPO membranes to the roof deck. (19.1 mm), or into the wood deck a minimum of 1 inch (25.4 mm). 3.9.14 PVC Oval Barbed Plate: This is a 11/2-inch-by- 23/4-inch(35 mm by 69.85 mm)Oval Barbed Plate designed 3.9.3 HP Purlin Fastener: This is an epoxy-coated steel to be used with HP-X Fasteners to mechanically attach PVC screw used in combination with Carlisle's fastening plates or membranes to the roof deck. bars to mechanically attach roofing insulation and membranes to structural steel members. Fastener length 3.9.15 OMG Roofing Products RhinoBond Plate: The must be selected to penetrate through the steel member a RhinoBond Plate is a 3-inch-diameter (76.2 mm), minimum of 3/4 inch (19.1 mm.) 0.028-inch-thick (0.7 mm) galvalume-coated steel plate, coated with a proprietary adhesive and used with the HP-X 3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy- fastener to mechanically attach PVC and TPO membranes coated steel screw used in combination with Carlisle's to the roof deck. The adhesive bonds the plate to the fastening plates or bars to mechanically attach roofing underside of the membrane. insulation and membranes to concrete roof deck. Fastener length must be selected to penetrate into the concrete deck 3.10 Carlisle SynTec Adhesives: See Tables 2 and 5 for a minimum of 1 inch (25.4 mm). adhered roofing systems. 3.9.5 CD-10 Fastener: The CD-10 is an epoxy-coated, 3.10.1 90-8-30A Bonding Adhesive: 90-8-30A Bonding hammer-driven, nonthreaded fastener specifically designed Adhesive is a high-strength, solvent-based contact to be used with insulation and seam fastening plates to adhesive used to adhere EPDM membranes to the secure membrane and insulation to structural concrete. insulation or substrate. It has a coverage rate of Fastener length must be selected to penetrate into the approximately 60 square feet per gallon (1.5 m2/L) when concrete deck a minimum of 1 inch (25.4 mm). applied to the finished surface area. The adhesive is supplied in 5-gallon (18.9 L)containers and has a shelf life 3.9.6 Lite-Deck Fastener:The Lite-Deck Fastener is used of one year. in conjunction with a specially designed 3-inch (76.2 mm) Lite-Deck Metal Plate for insulation attachment 3.10.2 Aqua Base 120 Bonding Adhesive:Aqua Base 120 to gypsum, cementitious wood fiber (Tectum [ESR-1112]), Bonding Adhesive is a high-strength, water-based contact and lightweight concrete decks. Fastener length must be adhesive used to adhere EPDM and TPO membranes to the selected to penetrate into the deck a minimum of 2 inches insulation or substrate. It has a coverage rate of (50.8 mm). approximately 120 square feet per gallon (3 m2/L) when applied to the finished surface area. The adhesive is 3.9.7 GypTec Fastener:The GypTec Fastener is a glass- supplied in 5-gallon (18.9 L)containers and has a shelf life filled nylon auger fastener designed for securing of one year. mechanically attached membranes and insulation to gypsum and cementitious wood fiber(Tectum [ESR-1112]) 3.10.3 Low-VOC PVC Bonding Adhesives: Low VOC decks. Fastener length must be selected to penetrate into PVC Bonding Adhesives is high-strength, solvent-based the deck a minimum of 1.5 inches(38.1 mm). contact adhesives used to adhere PVC membranes to an insulation or substrate. They have a coverage rate of 3.9.8 HP Polymer Seam Plate: This is a 2-inch-diameter approximately 60 square feet per gallon (1.5 m2/L) when (50 mm)polymer plate designed to be used with HP and HD applied to the finished surface area. The adhesive is 14-10 fasteners to mechanically attach roofing membranes supplied in 5-gallon (18.9 L) containers with a shelf life of to the roof deck. one year. 3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is 3.10.4 Sure-Weld TPO Bonding Adhesive: Sure-Weld a heavy-duty, epoxy-coated steel screw and bar used to TPO Bonding Adhesive is a high-strength, solvent-based secure reinforced EPDM membranes to steel or wood deck. contact adhesive used to adhere TPO membranes to an The bar is 1-inch-wide-by-0.040-inch-thick-by-10-foot-long insulation or substrate. It has a coverage rate of (25.4 mm by 1.1 mm by 3.1 m)galvalume-coated steel with approximately 60 square feet per gallon (1.5 rp2/L) wkier41 J pre-punched holes 6 inches(150 mm)on center. applied to the finished surface area. The 'adhesive is +d LA') 3.9.10 HP-X Fastener: This is an epoxy-coated carbon supplied in 5-gallon (18.9 L) containers with a shelf life of steel screw used in combination with the Piranha Fastening one year. 0 3/0 9/2 0 2 3 Plate to mechanically attach TPO membranes to steel or 3.10.5 Low VOC Bonding Adhesive: Low VOC onding wood substrate. Fastener length must be selected to Adhesive is a high-strength, solvent-based cg� IV BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 4 of 14 adhesive used to adhere EPDM and TPO membranes to an 4.0 INSTALLATION insulation or substrate. It has a coverage rate of 4.1 General: approximately 60 square feet per gallon (1.5 m2/ L) when applied to the finished surface area. The adhesive is Installation of the EPDM, PVC, and TPO roofing supplied in 5-gallon (18.9 L) containers with a shelf life of membranes described in this report must comply with the one year. applicable code, the manufacturer's published installation instructions and this report. The manufacturer's published 3.10.6 HydroBond Water-Based Bonding Adhesive: installation instructions must be available at all times on the HydroBond Water-Based Bonding Adhesive is a water- jobsite during installation. based,wet lay-in, one-sided adhesive to be used to adhere The substrate to which the membrane is to be applied Sure-Flex PVC, Sure-Flex PVC FRS and FleeceBACK must be clean, dry, and free of frost, loose fasteners, and membranes to an insulation or substrate. It has a coverage other protrusions or contaminates that will interfere with the rate of 100 square feet per gallon (2.5 m2/L). The adhesive adhesion or attachment of the membrane or that will is supplied in 5-gallon (918.9 L) containers with a shelf life puncture the membrane. All materials must be protected of one year. against contact with incompatible materials.Where gypsum 3.10.7 Low VOC Bonding Adhesive 1168: Low VOC board is used as barrier board in the roofing assembly, Bonding Adhesive 1168 is high-strength, solvent-based weather protection must be provided to prevent damage to contact adhesive used to adhere EPDM and TPO the gypsum board prior to application of the roofing membranes to an insulation or substrate. It has a coverage membrane. rate of approximately 60 square feet per gallon (1.58 m2/L) The slope of the roof on which the single-ply membranes when applied to the finished surface area. The adhesive is are installed must not be more than the maximum slope supplied in 5-gallon (18.9 L) containers with a shelf life of indicated for the particular assembly as listed in Tables 2 one year. and 3. 3.10.8 Cold Applied Adhesive: Cold Applied Adhesive is a Penetrations and terminations of the roof covering must solvent-free, asphalt-modified polyether adhesive. This be flashed and made weather tight in accordance with the adhesive can be used with all Sure-Seal or Sure-Weld AFX requirements of the membrane manufacturer and the membranes as a one-sided, wet lay-in adhesive. It has a applicable code. coverage rate of 67 square feet per gallon (1.6 m2/L). The 4.2 Fire Classification: adhesive is supplied in 5-gallon (18.9 L) containers with a 4.2.1 New Construction: The adhered and mechanically shelf life of one year. fastened EPDM, PVC, and TPO single-ply membrane 3.10.9 Flexible FAST Adhesives: Flexible FAST roofing systems, when installed in accordance with this Adhesives are two-component polyurethane adhesives report, are Class A, B or C roof covering systems in used to adhere FleeceBACK membranes and insulations to accordance with ASTM E108 or UL 790, as noted in Tables various substrates. The adhesives have a coverage rate of 2 and 3. approximately 100 square feet per gallon (2.5 m2/L). The 4.2.2 Reroofing: The existing deck must be inspected to adhesives are supplied in 5-gallon (18.9 L)jugs, 15-gallon verify that the structure to be reroofed is structurally sound (56.7 L) and 50-gallon (189 L) drums, box sets, cartridge and adequate to support and secure the roofing membrane. tubes, dual tanks, and/or cylinders, and have a shelf life of Prior to installation of new roof coverings, inspection by and one year. written approval from the code official having jurisdiction 3.10.10 OlyBond 500 Adhesive: OMG Roofing Products must be required. OlyBond 500 Spot Shot and OlyBond 500 BA are Class A, B or C roof covering systems may be installed two-component polyurethane adhesives used to adhere over existing classified roof covering systems under the insulations to various substrates. The adhesives have a following conditions without additional roof classification coverage rate of approximately 100 square feet per gallon tests, provided the resulting classification is the lower of the (2.5 m2/L). The adhesives are supplied in cartridge tubes new or existing roofing classification: and box sets, and have a shelf life of one year. • New uninsulated systems installed only over existing 3.10.11 EPDM X-23 Low-VOC Bonding Adhesive: uninsulated assemblies. EPDM X-23 Low-VOC Bonding Adhesive is a high strength, • New insulated systems installed over existing solvent-based contact adhesive used to adhere EPDM uninsulated systems only. membranes to an insulation or substrate. It has a coverage 4.3 Wind Resistance: rate of approximately 60 square feet per gallon (1.5 m2/L) 4.3.1 New Construction: The allowable wind uplift when applied to the finished surface area. The adhesive is pressures for the EPDM,PVC,and TPO roofing membranes supplied in 5-gallon (18.9 L) containers with a shelf life of as parts of roof assemblies are noted in Tables 4 and 5. one year. Metal edge securement systems must be listed in 3.10.12 CAV-GRIP III Low-VOC Adhesive/Primer: CAV- accordance with the 2011 edition of ANSI/SPRI/FM4435 GRIP III Low-VOC Adhesive/Primer is a contact adhesive ES-1 and designed and installed for wind loads in used to adhere EPDM and TPO membranes to various accordance with IBC Section 1504.5 and IBC Chapter 16. substrates. It has a coverage rate of 1000 ft2 per cylinder 4.3.2 Reroofing: Mechanically anchored systems may be when applied to the finished surface area. The adhesive is accepted based on the adequacy of anchors penetrating supplied in No. 40 cylinders with a shelf life of one year through existing roof coverings into structural substrates. (unopened). Since the composition and/or condition of any particular, 3.11 Impact Resistance: existing underlying material may vary widely, reroofing With±` ;- adhered systems is outside the scope of this report. The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in IBC 5.0 CONDITIONS OF USE n /f1912023 Section 1504.7,based on testing in accordance with Section The single-ply EPDM, PVC, and TPO roofing tfi�ii'fbres 4.6 of FM 4470. described in this report comply with, or are skit bl�SPEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 5 of 14 alternatives to what is specified in, those codes listed in 6.0 EVIDENCE SUBMITTED Section 1.0 of this report,subject to the following conditions: Data in accordance with ICC-ES Acceptance Criteria for 5.1 Installation must comply with the applicable code, the Membrane Roof-covering Systems (AC75), dated manufacturer's published installation instructions and July 2010(editorially revised April 2021). this report. The instructions within this report must 7.0 IDENTIFICATION govern if there are any conflicts between the manufacturer's installation instructions and this report. 7.1 Each roll of the roofing membrane must bear a label 5.2 The adhered and mechanically fastened single-ply noting the product name, the manufacturer's name membrane roofing systems must be installed by (Carlisle SynTec Systems) or the name of the professional roofing contractors who are trained and additional listee, the manufacturer's address or plant approved by the manufacturer. code and the ICC-ES evaluation report number (ESR-1463). 5.3 Foam plastic insulation must be separated from the 7.2 The report holder's contact information is the following: interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5 or IRC CARLISLE SYNTEC SYSTEMS, A DIVISION OF Section R316.4, as applicable. CARLISLE CONSTRUCTION MATERIALS, LLC 5.4 Foam plastic insulation, where used, must bear the POST OFFICE BOX 7000 label of an approved agency indicating that the foam CARLISLE, PENNSYLVANIA 17013 plastic has a flame-spread index of not more than 75 (717)245-7000 when tested at the maximum thickness intended for www•carlislesyntec.com use in accordance with ASTM E84 or UL 723, subject 7.3 The Additional Listees' contact information is the to the approval of the code official. following: 5.5 Design wind uplift pressure on any roof area, including MULE-HIDE PRODUCTS COMPANY, INC. edge and corner zones, must not exceed the allowable 1195 PRINCE HALL DRIVE wind uplift pressure for the system installed in that BELOIT,WISCONSIN 53511 particular area. Refer to allowable wind uplift pressures (800)786-1492 for systems as listed in Tables 4 and 5. 5.6 The allowable wind uplift pressures listed in Tables 4 VERSICO, A DIVISION OF CARLISLE and 5 are for the roof covering system only. The deck CONSTRUCTION MATERIALS, LLC and framing to which the system is attached must be POST OFFICE BOX 1289 designed for the applicable components and cladding CARLISLE, PA 17013 wind loads in accordance with the applicable code. (800)992-7663 5.7 When application is over existing roofs,documentation WEATHERBOND, A DIVISION OF CARLISLE of the wind-uplift resistance of the composite roof CONSTRUCTION MATERIALS, LLC construction must be submitted to the code official for POST OFFICE BOX 251 approval at the time of permit application. PLAINFIELD, PENNSYLVANIA 17081 5.8 For buildings under the IBC, above deck thermal (866)471-5125 insulation board must comply with the applicable ROOFING PRODUCTS INTERNATIONAL, INC. standards listed in IBC Table 1508.2 or IRC Table 57460 DEWITT STREET R906.2, as applicable. ELKHART, INDIANA 46517 5.9 The roofing membranes are manufactured at Carlisle, (800)628-2957 Pennsylvania; Greenville, Illinois; Tooele, Utah; and Senatobia, Mississippi,under a quality control program with inspections by ICC-ES. RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 6 of 14 TABLE 1—PRODUCT NAMES CARLISLE MULE-HIDE PRODUCT VERSICO PRODUCT WEATHERBOND PRODUCT ROOFING PRODUCTS PRODUCT NAME NAME NAME NAME INTERNATIONAL PRODUCT NAME Sure-Seal EPDM Mule-Hide Standard VersiGard Non-reinforced WeatherBond EPDM Non- Royal Edge Non- Black EPDM EPDM Reinforced Membrane Reinforced EPDM Sure-Seal FR EPDM Mule-Hide FR EPDM VersiGard FR Non- WeatherBond EPDM FR Royal Edge Non- Reinforced EPDM Non-Reinforced Membrane Reinforced FR EPDM Sure-Seal FleeceBACK WeatherBond Fleece EPDM Royal Edge EPDM EPDM - VersiFleece EPDM Membrane FleeceBACK Sure-Seal AFX EPDM - VersiFleece AC EPDM WeatherBond EPDM AC - Fleece Membrane Sure-Tough EPDM Mule-Hide Standard VersiGard Reinforced WeatherBond EPDM Royal Edge Reinforced Reinforced EPDM EPDM Reinforced Membrane EPDM Sure-White Mule-Hide White-on- VersiGard—White WeatherBond EPDM White Re-Flex White EPDM Black EPDM Standard Membrane Sure-White Re-Flex White EPDM FleeceBACK FleeceBACK Sure-Weld TPO Mule-Hide TPO-c VersiWeld Reinforced WeatherBond TPO Re-Flex TPO TPO Membrane Membrane Sure-Weld HS TPO Mule-Hide TPO-c(FR) VersiWeld HS WeatherBond TPO High Re-Flex TPO HS Slope Membrane Sure-Weld SAT-TPO Mule-Hide SA-TPO VersiWeld QA TPO WeatherBond TPO PAS Re-Flex TPO SAT Membrane Membrane Sure-Weld TPO Mule-Hide TPO-c WeatherBond FleeceTPO Re-Flex TPO FleeceBACK Fleece Back VersiFleece TPO Membrane FleeceBACK Sure-Weld TPO AFX Mule-Hide TPO-c VersiFleece AC TPO WeatherBond TPO AC Fleece Back Plus Fleece Membrane Spectra-Weld TPO - - - - Spectro-Weld - FleeceBACK TPO Mule-Hide PVC WeatherBond PVC Re-Flex PVC Sure-Flex PVC Membrane VersiFlex PVC Membrane Mule-Hide PVC KEE HP WeatherBond KEE HP Re-Flex KEE HP Sure-Flex KEE HP Membrane VersiFlex KEE HP Membrane Sure-Flex PVC FRS Mule-Hide PVC FRS VersiFlex FRS PVC WeatherBond PVC FRS Re-Flex FRS PVC Membrane Membrane Sure-Flex PVC Mule-Hide PVC VersiFleece PVC WeatherBond PVC Fleece - FleeceBACK FleeceBack Membrane Membrane Sure-Flex KEE HP Mule-Hide PVC KEE HP VersiFleece KEE HP WeatherBond KEE HP - FleeceBACK Fleece Back Membrane Fleece Membrane Sure-Flex PVC FRS VersiFleece FRS PVC WeatherBond PVC FRS Re-Flex FRS PVC FleeceBACK Fleece Membrane FleeceBACK Sure-Flex KEE HP FRS VersiFleece FRS KEE HP WeatherBond KEE HP FRS - - FleeceBACK Fleece Membrane 90-8-30A Bonding Mule-Hide Bonding I G200SA Yellow LC-60 Bonding Adhesive Royal Edge Bonding Adhesive Adhesive Substrate Adhesive Adhesive EPDM X-23 Low-VOC EPDM X-23 Low VOC EPDM X-23 Low VOC EPDM X-23 Low VOC - Bonding Adhesive Bonding Adhesive Bonding Adhesive Bonding Adhesive Aqua Base 120 Bonding Aqua Base 120 Bonding Aqua Base 120 Bonding Aqua Base 120 Bonding Royal Edge Water Based Adhesive Adhesive Adhesive Adhesive Bonding Adhesive Sure-Weld TPO Mule-Hide TPO-c VersiWeld TPO Bonding TPO Bonding Adhesive Royal Edge EPDM/TPO Bonding Adhesive Bonding Adhesive Adhesive Bonding Adhesive Low VOC Bonding Low VOC Bonding LOW VOC Bonding Low VOC Bonding Adhesive Royal Edge Low VOC Adhesive Adhesive Adhesive Bonding Adhesive Low VOC Bonding Low VOC Bonding Low VOC Bonding Low VOC Bonding Adhesive -- Adhesive 1168 Adhesive 1168 Adhesive 1168 1168 Low VOC PVC Bonding Low-VOC PVC Bonding Low-VOC PVC Bonding Low-VOC PVC Bonding Re-Flex PVC Low VOC Adhesive Adhesive Adhesive Adhesive Bonding Adhesive HydroBond Water- HydroBond Water- HydroBond Water-Based HydroBond Water-Based Based Bonding Based Bonding Bonding Adhesive Bonding Adhesive Adhesive Adhesive- CAV-GRIP III Low VOC Cav-Grip 3V Low VOC Cav-Grip III Low VOC - Adhesive/Primer AeroWeb Adhesive Adhesive/Primer Adhesive/Primer RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 7 of 14 TABLE 1—PRODUCT NAMES(continued) CARLISLE MULE-HIDE PRODUCT VERSICO PRODUCT WEATHERBOND ROOFING PRODUCTS PRODUCT NAME NAME NAME PRODUCT NAME INTERNATIONAL PRODUCT NAME Cold Applied Adhesive Cold Applied Adhesive Cold Applied Adhesive Cold Applied Adhesive RPI Cold Applied Adhesive Flexible FAST Adhesive Helix®Max Low-Rise Flexible DASH Adhesive Flexible DASH Adhesive FastBond Flex Adhesive Adhesive OlyBond 500 Adhesive - OlyBond 500 Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2,5 SYSTEM ROOF DECK MAX BARRIER BOARD INSULATION' MEMBRANE NO. CLASS SLOPE OR SLIP SHEET 1 1/4:12 Sure-Weld,Spectro-Weld Sure-Seal FR,Sure-Tough, Sure-White,Sure-Seal FleeceBACK, 2 /2:12 Any of the following Sure-Weld HS,Sure-Weld SAT-TPO, insulations, 1-inch min. Sure-Weld FleeceBACK, Spectro-Weld FleeceBACK, thickness:Carlisle A Noncombustible — "SecurShield Polyiso", Sure-White FleeceBACK "InsulBase", Hunter Sure-Flex PVC FleeceBACK, Panels"H-Shield"or"H- Sure-Flex KEE HP FleeceBACK, 3 3/4:12 Shield-CG" Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 4 1'/z:12 Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP 5 3/4:12 Sure-White FleeceBACK 6 I 1:12 Sure-Seal FR,Sure-Tough 1/2-inch-thick fiberboard4, Sure-White,Sure-Seal FleeceBACK, 1/2-inch-thick fiberboard4 Sure-Weld,Spectro-Weld,Sure-Weld or barrier board HS,Sure-Weld SAT-TPO, (see Section 3.6)over Sure-Weld FleeceBACK, A Noncombustible — 5-inch max Insulfoam EPS3, 1/2 inch-thick Spectro-Weld FleeceBACK, 7 11/2:12 fiberboard or barrier board Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP, (see Section 3.6)over System No. 1 insulations Sure-Flex PVC FleeceBACK, Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBACK 8 3/4:12 Sure-White FleeceBACK 9 11/2:12 Sure-White,Sure-Seal FleeceBACK Sure-Tough,Sure-Weld,Spectro-Weld, 10 I Noncombustible 3:12 1/4-inch thick Sure-Weld FleeceBACK, or Combustible "DensDeck Prime" Spectro-Weld FleeceBACK 11 A -min.15/32-inch- 4:12 or 1/4-inch thick _ Sure-Weld HS,Sure-Weld SAT-TPO thick plywood or "SECUROCK 12 min.7/16-inch- Unlimited Gypsum Fiber Roof Sure-Seal FR,Sure-Flex PVC, thick OSB. Board" Sure-Flex PVC FRS,Sure-Flex KEE HP Sure-Flex PVC FleeceBACK, 13 3:12 Sure-Flex KEE HP FleeceBACK, Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE HP FRS FleeceBack RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 8 of 14 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS2'5(continued) SYSTEM ROOF DECK MAX BARRIER BOARD INSULATION' MEMBRANE NO. CLASS SLOPE OR SLIP SHEET 14 1/4:12 Sure-Weld,Spectro-Weld Sure-Seal FR,Sure-Tough,Sure-White, Sure-Seal FleeceBACK,Sure-Weld HS, 15 1/2:12 Any of the following Sure-Weld SAT-TPO,Sure-Weld Combustible insulations, 1-inch min. FleeceBACK,Sp ectro Weld min.15/32-inch- Barrier board thickness:Carlisle A thick plywood or (see Section 3.6)or "SecurShield Polyiso", FleeceBACK,Sure-White FleeceBACK Slip sheet:2 layers Sure-Flex PVC FleeceBACK, min.7/16-inch- "InsulBase", Hunter Panels 16 thick OSB. 3/4:12 (see Section 3.7) "H-Shield"or"H-Shield- Sure-Flex KEE HP FleeceBACK, CG" Sure-Flex PVC FRS FleeceBACK, Sure-Flex KEE FRS FleeceBACK 17 2:12 Sure-Flex PVC,Sure-Flex PVC FRS, Sure-Flex KEE HP Noncombustible or Any of the following Combustible insulations, min. 1-inch. Any EPDM,PVC or TPO Membrane 18 C min.15/32-inch- Unlimited — thickness:Carlisle specified in this report thick plywood or "InsulBase"or Hunter min.7/16-inch- Panels"H-Shield" thick OSB. Single layer of minimum 3.0"or double layer of 19 A Combustible /z:12 — minimum 1.5"Carlisle Any EPDM,PVC or TPO Membrane "SecurShield Polyiso"or specified in this report Hunter Panels "H-Shield-CG" Single layer of minimum 20 A Combustible /z;12 — 1.9"Carlisle"SecurShield Any EPDM,PVC or TPO Membrane Polyiso"or Hunter Panels specified in this report "H-Shield-CG" For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2See Section 3.10 for adhesive application rate. 3UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to max.1/2:12. 'When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2021 IBC Section 1512,2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 9 of 14 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS4 SYSTEM ROOF DECK MAX. BARRIER BOARD INSULATION' MEMBRANE/MAX.ROOF SLOPE NO. CLASS SLOPE OR SLIP SHEET 1 /z:12 Any of the following Sure-Tough,Sure-Weld, insulations, 1-inch min. Spectro-Weld 2 A Noncombustible 11/2:12 — thickness:Carlisle Sure-Weld HS "SecurShield Polyiso"or 3 21/2:12 "InsulBase", Hunter Panels Sure-Flex PVC,Sure-Flex KEE HP "H-Shield"or"H-Shield-CG" 4 1:12 1/2-inch-thick fiberboard3, Sure-Tough,Sure-Flex /2-inch-thick fiberboard or barrier board (see Section 3.6)over 5-inch A Noncombustible — max Insulfoam EPS2, 5 11/2:12 1/2-inch-thick fiberboard or Sure Weld,Spectro-Weld, barrier board Sure-Weld HS (see Section 3.6)over System No. 1 insulations Insulfoam SP,5-inch max Sure-Weld,Spectro-Weld, 6 A Noncombustible 1/2:12 — thickness Sure-Weld HS,Sure-Flex, Sure-Flex KEE HP "Insulfoam SP"or min.1/2- Sure-Weld,Spectro-Weld, 7 A Noncombustible 1:12 — inch-thick Insulfoam EPS Sure-Weld HS,Sure-Tough covered with"Insulfoam SP" 8 Noncombustible 3:12 Sure-Tough,Sure-Weld,Spectro-Weld or Combustible 9 A min.15/32-inch- 31/2:12 Barrier board — Sure-Tough FR thick plywood or (see Section 3.6) min.7/16-inch- Sure-Weld HS,Sure-Flex, 10 thick OSB. Unlimited Sure-Flex KEE HP 11 1/2:12 Any of the following Sure-Tough,Sure-Weld,Spectro-Weld Combustible insulations, 1-inch min.to min. 15/32-inch- 1 Barrier board 6-inch max.thickness: 12 1 /z:12 (see Section 3.6)or Sure-Weld HS A thick plywood or Carlisle"SecurShield — 13 min.'/1s inch- 3/4:12 Slip sheet:2 layers, Polyiso"or"InsulBase", Sure-Tough FR thick OSB. (see Section 3.7) Hunter Panels"H-Shield"or 14 21/2:12 "H-Shield-CG" Sure-Flex PVC,Sure-Flex KEE HP 15 Combustible 1:12 Sure-Tough min.15/32 inch- Slip sheet,2 layers A thick plywood or — Sure-Tough FR,Sure Weld, (see Section 3.7) 16 min.7/16-inch- 11/2:12 Spectro-Weld,Sure-Weld HS, thick OSB Sure-Flex,Sure-Flex KEE HP Combustible min.15/32-inch- Slip sheet, Sure-Tough,Sure-Tough FR, 17 B thick plywood or 11/2:12 1 layer — Sure-Weld,Spectro-Weld,Sure-Weld min.7/16-inch- (see Section 3.7) HS,Sure-Flex,Sure-Flex KEE HP thick OSB. Combustible Any of the following min 15/32 inch- insulations, 1-inch min. 18 C thick plywood or Unlimited — thickness:Carlisle Any EPDM,PVC or TPO Membrane min.'/1s inch- "SecurShield Polyiso"or specified in this report thick OSB. "InsulBase",Hunter Panels "H-Shield"or H-Shield CG" Single layer or double layer of 19 A Combustible /z:12 — minimum 1-inch Carlisle Any EPDM,PVC or TPO Membrane "SecurShield Polyiso"or specified in this report Hunter Panels"H-Shield-CG" Minimum 1/2-inch Carlisle"SecurShield HD","SecurShield HD Plus", Any EPDM,PVC or TPO Membrane 20 A Combustible 1:12 — "SecurShield HD NH", "SecurShield HD Plus NH", specified in this report "SecurShield HD Plus",or "SecurShield HD RL" For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with)Section of this report or the maximum thickness in accordance with this table,whichever is less. _' I 4(J 2UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.''/z-Jrch-tIiick . �' ' ; Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 3Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these ty�p.k�o b ge/2 0 2 3 used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. V 3/ G 'When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicabh1le PEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 10 of 14 TABLE 4—WIND RESISTANCE—MECHANICALLY FASTENED ASSEMBLIES4'7 MAXIMUM MAXIMUM MAXIMUM SYSTEM ALLOWABLE MEMBRANE MEMBRANE FASTENER FASTENER NO. WIND UPLIFT DECK3 INSULATION 5 FASTENING SPACING ROW (psf) (inches) SPACING' Foam plastic insulation12' 1 45 Noncombustible 1/2-inch-thick fiberboards or Sure-Tough HP-X Fastener& 12 6 ft 6 inches barrier board Metal Fastening Bar (See Sect.3.6) 2 75 Noncombustible Same as System No. 1 Sure-Tough HP-X Fastener& 6 6 ft 6 inches Metal Fastening Bar 3 52 Noncombustible Same as System No. 1 Sure-Tough HP Fastener& 6 9 ft 6 inches Polymer Seam Plate 4 45 Noncombustible Same as System No. 1 Sure-Tough Sure-Tite Fastener& 12 9 ft 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 12 9 ft 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 6 9 ft 6 inches (75 mil) Polymer Seam Plate Sure-Weld or HP-X or HP-Xtra 7 45 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 7 ft 6 inches or Piranha Xtra Plates 8 45 Noncombustible Same as System No. 1 Sure-Weld or HP-Xtra Fasteners with 12 9 ft 6 inches Spectro-Weld Piranha Xtra Plates HP-X or HP-Xtra 9 60 Noncombustible Same as System No. 1 Sure-Weld or Fasteners with 6 9 ft 6 inches Spectro-Weld Piranha or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 10 67 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 7 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 11 30 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 11 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 12 60 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 11 ft 6 inches or Piranha Xtra Plates 13 53 Noncombustible Same as System No.1 Sure-Flex PVC or HP-X Fasteners with 6 6 ft 4 inches Sure-Flex KEE HP Piranha Plates 14 83 Noncombustible Same as System No.1 Sure-Flex PVC or HP-X Fasteners with 6 2 ft 11 inches Sure-Flex KEE HP Piranha Plates Sure-Flex PVC or HP-X or HP-Xtra 15 30 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 18 6 ft 4 inches or Piranha Xtra Plates Sure-Flex PVC or HP-X or HP-Xtra 16 45 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No.1 Sure-Flex PVC or HP-X Fasteners with 12 2 ft 11 inches Sure-Flex KEE HP Piranha Plates Sure-Flex PVC or HP-X or HP-Xtra 18 60 Noncombustible Same as System No.1 Sure-Flex KEE HP Fasteners with Piranha 6 9 ft 7 inches Plates 19 45 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 5.3 ft2 N/A OMG RhinoBond Plates 20 60 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 4 ft2 N/A OMG RhinoBond Plates For SI: 1 inch=25.4 mm; 1 ft=0.305 m;1 psf=47.88 Pa. 1Foam plastic insulation must be any of the following(1-inch min.to 6-inch max.thickness):Carlisle"SecurShield Polyiso","InsulBase"Hunter Panels"H-Shield"or Hunter Panels"H-Shield-CG". 2All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 'Steel deck must be minimum No.22 gage galvanized steel[base-metal thickness 0.030 inch(0.76 mm)].Concrete must have a minimum compressive strength(ft) of 2500 psi.See Section 5.6 of this report. 4For existing metal roofing,the assemblies listed must be installed by fastening through the roofing and into structural members(purlins,angle iron,beams,etc.) capable of resisting all expected loads.The maximum allowable wind uplift(field)pressures are shown in Column 2. 5UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. �VE D 7When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and 2021T 2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907,a' lir 2a le. 'Fastener row spaces shown are for field of roof only.See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies.Distance between the edge of the roof and the first row of fasteners must be determined accordingly. 0 3/0 9/2 0 2 3 ASPEN BUILDING DEPARTMENT ESR-1463 I Most Widely Accepted and Trusted Page 11 of 14 TABLE 5—WIND RESISTANCE—ADHERED ASSEMBLIES5,6 ALLOWABLE INSULATION SYSTEM WIND UPLIFT DECK2 INSULATION/MIN.THICKNESS''' FASTENING MEMBRANE NO. (FIELD) RATE TYPE (psf) 1/2 inch fiberboard4,15/32 inch OSB,or'/4-inch thick 1 45 Combustible or "DensDeck Prime"or 1/4-inch thick"SECUROCK 1 er 2 ft2 EPDM, PVC and TPO Noncombustible Gypsum Fiber Roof Board" p Membranes Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 2 45 Combustible or Panels"H-Shield"or"H-Shield-CG"/1.4 inch 1 per 3.2 ft2 EPDM, PVC and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 3 45 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 4 ft2 EPDM, PVC and TPO Noncombustible with 5/8-inch SECUROCK coverboard(optional) Membranes 4 68 Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter FAST Adhesive FleeceBACK Membranes Noncombustible Panels"H-Shield"or"H-Shield-CG"/1.0 inch Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 5 75 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1.6 ft2 EPDM, PVC and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes 6 113 Combustible or Carlisle"SecurShield"or"H-Shield CG"/2.0 inch 1 per 1ft2 PVC Membranes Noncombustible TPO Membranes; 7 120 Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 1per 1 ft2 EPDM membranes Noncombustible Panels"H-Shield"or"H-Shield-CG"/2.0 inch p (with noncombustible deck only) Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 8 128 Combustible or Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft2 EPDM and TPO Noncombustible with 1/2-inch SECUROCK coverboard(optional) Membranes Combustible or Carlisle"InsulBase"or"SecurShield Polyiso"; Hunter 9 135 Noncombustible Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft2 FleeceBACK Membranes with 1/2-inch SECUROCK coverboard(optional) 10 143 Combustible or 1/2 inch DensDeck Prime 1 per 1 ft2 FleeceBACK Membranes Noncombustible For SI: 1 inch=25.4 mm; 1 ft=0.305 m;1 psf=47.88 Pa 1A11 foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2Steel deck must be minimum No.22 gage galvanized steel[base-metal thickness 0.030 inch(0.76 mm)].Concrete must have a minimum compressive strength (f'c)of 2500 psi.See Section 5.6 of this report. 3UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.1/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 'When application is over existing roofs,documentation of the wind-uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application.For reroofing or recovering,installation must be in accordance with 2021 IBC Section 1512,2018 and 2015 IBC Section 1511 [2012 and 2009 IBC Section 1510],2021,2018 and 2015 IRC Section R908[2012 and 2009 IRC Section R907],as applicable. 'See Section 3.10 for adhesive application rate. RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESICC EVALUATION SERVICE' ICC-ES Evaluation Report ESR-1463 LABC and LARC Supplement Reissued October 2021 Revised March 2022 This report is subject to renewal October 2022. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS,A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes,described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety(LADBS). Applicable code editions: • 2020 City of Los Angeles Building Code(LABC) • 2020 City of Los Angeles Residential Code(LARC) 2.0 CONCLUSIONS The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463,comply with the LABC Chapters 7A and 15,the LARC Section R337 and LARC Chapter 9,and are subjected to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes, described in this evaluation report must comply with all of the following conditions: • All applicable sections in the evaluation report ESR-1463. • The design, installation, conditions of use and identification are in accordance with the 2018 International Building Code® (IBC) and 2018 International Residential Code® (I RC) provisions noted in the evaluation report ESR-1463. • The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, or LARC Chapter 3, as applicable. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must not be installed over existing wood shakes or wood shingles in accordance with LABC Section 1511. • The installation of the Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes must comply with City of Los Angeles Information Bulletin P/BC 2020-16, "Dwellings in High Wind Velocity Areas(HWA)". • Reroofing applications must comply with Sections 4.2.2,4.3.2 and 5.7 of the evaluation report ESR-1463 and LABC Section 1511 or LARC Section R908, as applicable. Where spaced sheathing exists, a minimum of 15/32-inch-thick (11.9 mm)plywood shall be installed prior to roofing installations. I, 11 ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed icc as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. oE�taZ Copyright©2022 ICC Evaluation Service,LLC. All rights reserved. Page tSiREN BUILDING DEPARTMENT ESR-1463 LABC and LARC Supplement I Most Widely Accepted and Trusted Page 13 of 14 • Where moderate or heavy foot traffic occurs for maintenance of equipment,the roof covering shall be adequately protected. • The Building Inspector shall be notified 24 hours in advance prior to installation of the roof membranes. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Building Code®(IBC)provisions noted in the evaluation report and the additional requirements of Sections 701A.3 and 705A of the LABC. • The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of Sections R337.3.1 and R337.5 of the LARC. This supplement expires concurrently with the evaluation report, reissued October 2021 and revised March 2022. RECEIVED 03/09/2023 ASPEN BUILDING DEPARTMENT ESICC EVALUATION SERVICE' ICC-ES Evaluation Report ESR-1463 CBC and CRC Supplement Reissued October 2021 Revised March 2022 This report is subject to renewal October 2022. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC SYSTEMS,A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, LLC EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE-PLY ROOFING MEMBRANES 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Carlisle EPDM, PVC and TPO single-ply roofing membranes,described in ICC-ES evaluation report ESR-1463, have also been evaluated for compliance with the codes noted below. Applicable code editions: • 2019 California Building Code(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD)and Division of State Architect(DSA), see Sections 2.1.1 and 2.1.2 below. • 2019 California Residential Code(CRC) 2.0 CONCLUSIONS 2.1 CBC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CBC Chapter 15, provided the design and installation are in accordance with the 2018 International Building Code°(IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapter 15, as applicable. The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Building Code°(IBC)provisions noted in the evaluation report and the additional requirements of Sections 701A.3 and 705A of the CBC. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The Carlisle EPDM, PVC and TPO single-ply roofing membranes, described in Sections 2.0 through 7.0 of the evaluation report ESR-1463, comply with CRC Chapter 95, provided the design and installation are in accordance with the 2018 International Residential Code°(IRC)provisions noted in the evaluation report and the additional requirements of CRC Chapter 9, as applicable. The Carlisle EPDM, PVC and TPO Single-ply Roofing Membranes may be used in the construction of new buildings located in any Fire Hazard Severity Zone within a State Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the 2018 International Residential Code°(IRC)provisions noted in the evaluation report and the additional requirements of Sections R337.3.1 and R337.5 of the CRC. This supplement expires concurrently with the evaluation report, reissued October 2021 and revised March 2022. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed it as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as i f A. to any finding or other matter in this report,or as to any product covered by the report. Copyright©2022 ICC Evaluation Service,LLC. All rights reserved. Page ASHEN BUILDING DEPARTMENT DMC 450SL Profile DrexelVietals -" Roofing Systems+Custom Fabrication Installation ease with , Ali impeccable results makes r our DMC 450SL roof system a standout choice. The 1-1/2" Snap Lock profile and DMC 450SL Clip create a continuous interlocking system that installs quickly, reducing \ labor costs. The concealed fastener and clip application also allow thermal expansion and contraction movement to help keep the beautiful finish straight and true. Ideal Application: : ' ' \\ "NA Commercial P Residential lb ! ilk 1 s i fa ..•,. — '1%.41% .,. 4.007:\• 11%, . . •. ....„ -IN.. , ...:, .. ._ a ,1 ,orN 1 ..,_ 11 Li . 4. - _ , g , k L '111.1164 raktva[ . r- Lfr4:: /Pi" s L _ - 1.--i ;ILEMMY r — _"_03/09/2023 i __ - _'S.'.pi �r ___ _ DM0 450SL Profile Available widths: " -7 16"* ,�� 12 *Drexel Metals design pressures,wind uplifts and test .f X reports are for specific deck attachments,material gauges, clip spacing and panel widths.A complete specification and listing is available online at www.drexelmetals.com 16"COVERAGE .- Substrates available: • • ■ • • • • • •Galvalume®-24ga • Drexlume®-24ga • • • • • • • • • • • • . . . . . . . . . Finishes and product warranty: Galvalume®Substrate: Drexlume®Substrate: Available in a variety of coatings High-performance Mill finished and colors by AkzoNobel. See the painted metal roofing Galvalume®with a Drexel Metals color card for product, carefully two-sided, clear standard colors and paint itir, tensioned leveled for acrylic finish. s ecifications. superior flatness. p AkzoNobel 25 YEAR WARRANTY romor.owsAnswersbel 35YEAR WARRANTY 25-Year Non Pro-rated 35-Year Non Pro-rated Drexlume Warranty PVDF Paint Warranty (Acrylic Coated Galvalume) Production options: Factory made or field rolled to exact lengths Optional: striation, beads, pencil ribs Installation: Can be installed over plywood MetShield decking and Drexel Metals U n d e r l a y m e n t MetShield®underlayment. Slope: Minimum slope 3:12 Minimum Roof Pitch: 3:12-low roof pitch Testing: G\pss'F,e •• UL 580 Wind Uplift(Class 90) In accordance with: ® • UL 2218 Class 4 Hail Impact • UL 263 Fire Certification • UL 790 Class A Fire Rating • UL Environmental-SRI Third-Party Verified DrexelVietals \ 1234 Gardiner Lane, Louisville, KY 40213 - - F YL3 r Roofing Systems+Custom Fabrication ���� 888-321-9630 toll free • 502 690 6174 fax ",,,:7IFrARI VED www . drexelmetals . com 03/09/2023 ©2013 Drexel Metals,Inc.All rights reserved.Galvalume°is a registered trademark of BEIC International,Inc.Drexlume"is a trademark of Drexel Metals,Inc.ENERGY STAR name and logo are registered U.S.marks and are owned by the U.S.government.Colors shown represent the actual color as closely as possible.To ensure exact color for final approval,a metal color chip is available.Warranty statements mentioned are outlines:complete Limited Warranty information is available on request.No other warranty expressed or implied is applicable. ASPEN Titanium® PSU30 is a secondary water barrier for use on TITANIUM PSU30 ROLL SPECS steep slope roofs under asphalt shingles, composite shingles, metal, concrete and clay tile, slate, and wood LENGTH PER ROLL: 72'/22 m psu Inv. shakes. Titanium° PSU30 is a flexible, high temperature WIDTH PER ROLL: 36"/0.914 cm premium self adhered underlayment designed with the WEIGHTPERROLL: 48Ibs/21.8kgTITANIUM® patented Sure-Foot® nodular walking surface technology GROSS ROLL SIZE: 216 sq ft/20 m2 30 that allows for easier steep slope walkability,even in wet NET OF OVERLAP: 2sq/18.58m2 or dusty conditions. ROLLS PER PALLET: 25 SELF-ADHERED ROOFING UNDERLAYMENT simi PALLET WEIGHT: 1,300 Ibs/590 kg It's tough, durable, coated woven synthetic facer and PREMIUM HIGH TEMPERATURE SELF-ADHERED rubberized asphalt formulation is engineered to lay flat •Split release liner UNDERLAYMENT FOR PROTECTION FROM SHINGLE and not buckle or wrinkle when exposed to temperature BLOW-OFF,WIND-DRIVEN RAIN AND ICE DAMMING and moisture fluctuations on the roof. •Watertight asphalt to asphalt horizontal lap system PSU30 is designed full roof deck waterproof protection •Up to 180 days UV exposure rating FOR USE UNDER: with 180 day UV exposure rating.Titanium PSU30 used in •Meets or exceeds ASTM D1970 conjunction with Titanium UDL30 synthetic roofing •ASTM E108 Class A Fire Resistance when installed under ASPHALT, METAL, TILE, SLATE, underlayment provides complete roof deck protection asphalt shingles from the brand contractors know and trust. SHAKE & COMPOSITE SHINGLES •PSU30 is approved for use with ICP AH-160 and PSU30 provides a surface that will help protect the RTA-1,and Dow TileBond foam adhesives underside of the metal from natural movement without causing damage to the underneath of metal roofing Florida• Product Approval systems, compared to other underlayments that could •All temperature performance-20°F to 240°F cause damage to metal roofing systems including making - - • Installation temperature 40°F and above them susceptible to premature corrosion. ,.. e., 110°P... •Synthetic construction inert to mold growth r M d — d f� A. -- - '' �+` — ._ PREMIUM PROTECTION �.... ,, <, y ;, j'% ► SECONDARY WATER BARRIER no"...",:`...` � �` • y t� TITANIUM PSU30 TECHNICAL DATA ,1�ti•..` 4t _iv. TEST&STANDARD° TITANIUM PSU30 TYPICAL VALUE �`� VP- p I1HIGH TEMPERATURE RATED COLOR Gray -_il SURFACE Synthetic Polymer-Patented Sure-Foot"'slip resistant nodular Designed and engineered to withstand high temperatures RELEASE LINER Silicone treated,poly split release ' * /a� (240°F/115°C)in metal applications WEIGHT PER SQUARE 241bs/(10.8kg) k '44 * NAIL SEALABILITY ASTM 01910 Pass g S' 4 ill STRONG DECK ADHESION PERMEABILITY ASTME96 0.0336 Obi" TITANIUM® The modified rubberized asphalt provides a superior NOMINAL THICKNESS ASTMD5147 45 Mil(1.1mm) combination of low temperature deck adhesion and high TENSILE ASTM D1970 MD100Ihs/in/(11.51M/m)CD80IbsM(14kN/m) LIFETIME temperature flow resistance THERMAL STABILITY ASTM01910 240°F(115°C)Pass LOW TEMP FLEXIBILITY ICC AC 48 Pass TEAR RESISTANCE ASTM D1970 MD 140/CD 100 Ibf(622/445 N) LIMITED WATERTIGHT LAP SYSTEM ADHESION TO PLYWOOD ASTM D903 4 lb/in(100 N/m) PSU30 provides a self-sealing lap seal system which WARRANTY forms an impervious asphalt to asphalt bond at overlapping seams, delivering superior waterproofing TITANIUM'Synthetic Roofing Underlayment protection. Charleston,SC•Mission,BC•Montreal,QC Email:answers@owenscorning.com SUPERIOR WALKABILITY! SAFER SLIP RESISTANCE Toll Free:800.567.9727 eavetopeak.com Our patented Sure-Foot' nodular surface provides , II _ irtyconditions.excellent ility and slip resistance even in wet or SigliVititir NM ■ dirty rty C tIOt1 'Titanium brand products are manufactured in accordance with national standards which allow for noncritical variances in weights and measurements.Test data is based on an average taken over several production runs and should not be considered or interpreted as maximum or A� minimum values.Values are typical data and not limiting specifications.All values±10%. ©2021 Owens Coming.All Rights Reserved. Patented Sure-Foot nodular walking surface Pub No.10021442-E April 2021 PSU30 INSTALLATION INSTRUCTIONS 6. After installation of each piece, remove the release lining from the selvage and, if necessary, secure with nails installed in the selvage spaced 6 inches on center.This fastening is required when Titanium® A CAUTION PSU30 is installed on slopes of 3:12 or greater.Consult local building - Read and understand all instructions and precautions before applying codes for fastener requirements. , Titanium® PSU30 underlayment. Check local building codes prior to 7. The entire roof surface should be rolled after installation of the ' application of this product. Follow the recommendations of the roof Titanium®PSU30 using a minimum 40 lb.roller.Hand rolling over the covering manufacturer, Asphalt Roofing Manufacturer'sAssociation selvage and directly above the selvage using a minimum 4 inches (for asphalt shingles),Tile Roof Institute(for clay orconcrete roof tiles), wide,minimum 10 lb.roller is recommended. and the Metal Roofing Alliance(for metal roof panels). 8. Overlap at least 6 inches where the ends of two rolls meet. Apply heavy hand pressure or use a roller along the seam overlapping the DECK PREPARATION next roll. 9. End laps should be offset a minimum of 6 feet on adjacent courses. The deck must be clean, smooth and dry before applying Titanium® PSU30 underlayment. Remove all old roofing down to the deck or, in 10. Along a valley,Titanium®PSU30 underlayment can be cut lengthwise new construction,apply over the new deck.Sweep the deck surface to for easier handling. For maximum protection, the roll width should • -— remove dirt and debris.Replace any damaged or rotted deck boards. remain ® side Remove the intact releaseand backer and press Titanium®Pr SU30 undofetherlayment ' into place,working from theextend center inches of the valleyeith or ridge outwardvalley.in A ALLOWABLE SUBSTRATES each direction.Always apply valleys starting at the low point and work --7---'-- PSU30 self-adhered underlayment can be installed over Plywood,OSB, upward. If an overlap is needed,be sure to overlap the previous piece FRT Plywood, Polyisocyanurate foam insulation board, metal by minimum 4 inches. Titanium® PSU30 underlayment should be (galvalume steel),301b felt,PSU30,pre-wrapped sheathing,DensDeck® applied in valleys before installing eave applications with membranes. and USG Securock®Primer is not required on clean,dry deck surfaces, except for gypsum boards (DensDeck® and USG Securock® roof For further detail on various installation methods, please call boards)for which appropriate primer or adhesive is recommended at 1-800-ROOFING(1-800-766-3464). temperatures s 40F. PRECAUTIONS - .DECK EDGE PREPARATION 1. Cover Titanium® PSU30 underlayment with finish roof covering. Do Along eaves, install metal drip edge under the Titanium® PSU30 not allow Titanium® PSU30 underlayment to remain uncovered. underlayment unless otherwise directed by local building codes.Along Exposure to sun and weather for more than 180 days may adversely rakes,apply Titanium®PSU30 underlayment first,and put drip edge on top. affect this product's performance. 2. Titanium®PSU30 underlayment should be installed by a professional TILE ROOF roofing contractor. Ili - INSTALLATION TILE LOADING TABLE 3. Titanium®PSU30 underlayment is a moisture and vapor barrier.The spaces under the covered deck area and the attic space must be Please see the table for Tiles in Stacking Tile Maximum ventilated in accordance with local building codes. tile loading limitations. `Stack Pattern Type Roof Pitch 4. Titanium® PSU30 underlayment is intended for exterior roof Loading of tile outside 10 10 Linear Flat 5:12 the parameters of this application only and is not intended for use on vertical surfaces. - table requires installation 10 10 Linear Profiled 6:12 5. Apply PSU30 directly to the roof deck.Allowable roof deck materials of loading battens prior are shown in Section 1 of these instructions. Do not apply Titanium® to tile loading. PSU30 over another layer of underlayment unless required by local codes. *' ' le. *. When installing Titanium® PSU30 underlayment over the entire roof deck,proper ventilation is required.Consult a design professional 6. Roof coverings should not be installed over wrinkled or buckled Titanium®PSU30 underlayment. O I j and local building codes for ventilation requirements. 7. Use extreme caution when installing Titanium®PSU30 underlayment. l TEMPThe Titanium® PSU30 underlayment surface may be slippery even when dry. Use of fall protection is highly recommended. Consult PRO ECT 0 METAL ROOF INSTALLATION OSHA for guidelines on fall protection(29 CFR 1926.500). Slopes 2:12 and greater 8. For best results,apply Titanium®PSU30 underlayment when the air -, Follow standard installation instructions below. temperature is over 40°F (5°C) and rising, but below 100°F (38°C). Slopes 1/2:12-less than 2:12 When temperatures are under 40°F (5°C), Titanium® PSU30 `=+ _ For standing seam metal roof panels follow standard installation underlayment will not fully adhere.Store at room temperature prior to -_ ® ., ' instructions below with the following modifications: End Laps must be installing product in cold weather. If applied in temperatures above '� min.6 feet apart in adjacent courses.All end laps must be minimum 6 100°F(38°C), or exposed to direct sunlight,the release backing may '9 �'''' inches wide.Apply min.6 inch wide bed of ASTM D4586 compliant roof become difficult to remove. If this situation should occur, move the ment is 4i l cement at end of underlying piece and set overlying piece into roof product into a shaded area until the Titanium®PSU30 underlayment ry k; cement,applying firm pressure on entire end lap. cool.Once cooled,the release backing can be easily removed. 9. Store Titanium® PSU30 underlayment in a dry, well ventilated area. _: STANDARD INSTALLATION Stand Titanium® PSU30 underlayment upright. Do not store at 1. Ensure that decking substrate is acceptable to roof covering 90°F (32°C) or warmer for extended periods of time. Do not store �_ - manufacturer. in direct sunlight. 2. Unroll Titanium® PSU30 underlayment and cut into manageable 10. When applying Titanium® PSU30 underlayment, always follow 444 , , _____. lengths no more than 15 20 feet. local building codes and the roof covering manufacturer's 1.�i� a 3. Allow it to relax for 3 5 minutes before installing. instructions for installation of this product. 4. Reroll each section. 11. When working on the roof, use all necessary safety precautions 5. Start at the eaves,laying the Titanium®PSU30 parallel to the eaves � , elli edge,with the lower edge of the Titanium® PSU30 flush with the vi aICI outside of the primed drip edge.The lower edge of the and guidelines in accordance with proper rocfin�tad=r�r-act,ces underlayment is the edge that does not have a selvage edge. - PRODUCT INFORMATION Technical Data Applicable Standards & Approvals • Titanium®PSU30 Roll Specs ASTM D1970 • ASTM E108/UL 790,Class A Fire Resistance Length per roll: 72'/22 m • Florida Product Approval • Texas Department of Insurance Width per roll: 36"/91.4 cm • PRI ER 1378E02 Weight per roll: 51 lbs/23.1 kg Gross roll size: 216 sq ft/20m2 Net of overlap 2 sq/18.582 Rolls per pallet: 25 Pallet weight: 1356 lbs/615 kg Test Standard Titanium®PSU30 Typical Value Color Gray Surface Synthetic Polymer-Patented Sure-Foot®slip resistant nodular Release Liner Silicone Treated,Crinkled Poly Split Release Weight per square 24 lbs/(10.8 kg) Nail Sealability ASTM D1970 Pass Permeability ASTM E96 0.0336 Nominal Thickness ASTM D5147 45 Mil(1.1 mm) Tensile ASTM D1970 MD 100 lbs/in/(17.5 kN/m)I CD 80 lbs/in(14 kN/m) Thermal Stability ASTM D1970 240°F(115°C)Pass Low Temp Flexibility ICC AC 48 Pass Tear Resistance ASTM D1970 MD 140/CD 100 lbf(622/445 N) Adhesion to Plywood ASTM D903 4 lb/in(700 N/m) rt. Titanium'brand products are manufactured in accordance with national standards which allow for non-critical variances in weights and measurements. RE R,i E I /E i6 Test data is based on an average taken over several production runs and should not be considered or interpreted as maximum or minimum values.Values are typical data and not limiting specifications.All values±10%. 0 3/0 9/A 0 A 3 UL Class A Fire Resistance applies when installed under asphalt shingles 1 1 ASPEN BUILDING DEPARTMENT